displaying 1000 best results Help
Search results for: SOFC, CORROSION, COATING
-
Sulfate‐reducing bacteria‐assisted hydrogen‐induced stress cracking of 2205 duplex stainless steels
PublicationThe paper presents the results of a laboratory investigation of the microbiologically assisted hydrogen‐induced stress cracking (HISC) of 2,205 duplex stainless steel (DSS). The testing of susceptibility toward HISC was performed with two different methods. Precharged in sulfate‐reducing bacteria (SRB), inoculated medium samples were subjected to slow strain‐rate testing in artificial seawater. In situ constant load tests were...
-
Metal dusting in CCR platforming unit
PublicationPrzedstawiono mechanizm pylenia metalu w stali 9Cr-1Mo w instalacji platformingu CCR, na postawie badań rury podgrzewacza wsadu po 10 latach pracy, przy temperaturze metalu koło 600C. W badaniach wykorzystano techniki elektronowej mikroskopii skaningowej, dyfrakcji rentgenowskiej i mikroanalizy rentgenowskiej. Wykazano, że dyfuzji wegla w głąb stali toarzyszy odrdzeniowa dyfuzja pierwiastków węglikotwórczych - chromu i molibdenu....
-
Dynamic electrochemical impedance spectroscopy and polarization studies to evaluate the inhibition effect of benzotriazole on copper-manganese-aluminium alloy in artificial seawater
PublicationPrzeprowadzono badania wpływu benzotriazolu (BTA) na korozję nowego typ mosiądzu (CMA) w środowisku syntetycznej wody morskiej przy użyciu dynamicznej elektrochemicznej spektroskopii impedancyjnej (DEIS), techniki polaryzacji rezystancyjnej i ekstrapolacji krzywych Tafela. Wyniki pomiarowe otrzymane przy użyciu tych metod wskazują spadek szybkości korozji wraz ze wzrostem stężenia BTA. Wskazuje to na inhibicyjne własności BTA w...
-
Metal dusting in CCR platforming unit
PublicationPrzedstawiono mechanizm pylenia metalu w stali 9Cr-1Mo w instalacji platformingu CCR, na postawie badań rury podgrzewacza wsadu po 10 latach pracy, przy temperaturze metalu koło 600C. W badaniach wykorzystano techniki elektronowej mikroskopii skaningowej, dyfrakcji rentgenowskiej i mikroanalizy rentgenowskiej. Wykazano, że dyfuzji wegla w głąb stali toarzyszy odrdzeniowa dyfuzja pierwiastków węglikotwórczych - chromu i molibdenu....
-
Hydrogen degradation of structural steels in technical hydrocarbon liquids
PublicationDla stali stopowych przeprowadzono badania absorpcji wodoru, mechaniczno-korozyjne przy stałej małej prędkości odkształcania, przy stałym obciążeniu i przy obciążeniu cyklicznie-zmiennym. Środowiskiem było paliwo kotłowe, przepracowany olej mineralny oraz gliceryna. Stwierdzono, iż pochłonięty wodór nie powoduje przedwczesnego zniszczenia stali poddanych działaniu stałego obciążenia ponizej granicy plastyczności oraz, że zaabsorbowany...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 100 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 60 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 40 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 85 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 55 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 130 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 110 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 120 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 75 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 65 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 90 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 80 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 45 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 35 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 50 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 70 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapasitor with the use of ZnO coated microsphere-based fiber-optic sensor - 30 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
COMPARISON OF TWO MODELS OF CONDENSATION
PublicationIn the low-pressure part of steam turbine, the state path usually crosses the saturation line in penultimate stages. At least last two stages of this part of turbines operate in two –phase region. The liquid phase in this region in mainly created in the process of homogeneous and heterogeneous condensation. Several observations confirm however, that condensation often occurs earlier than it is predicted by theory i.e. before the...
-
The impact of material degradation on the resistance and reliability of truss structures
PublicationThe paper analyses limit load-carrying capacity and buckling load of truss towers used to support high voltage power lines. The analysed typical structure was subjected to characteristic loads and their combinations. The results were applied to assess structural resistance with regard to steel corrosion in the long-term operation. The extent of structural deterioration was assessed due to Young's modulus decrement in the course...
-
A Simple Replica Method as the Way to Obtain a Morphologically and Mechanically Bone-like Iron-Based Biodegradable Material
PublicationPorous iron-based scaffolds were prepared by the simple replica method using polyurethane foam as a template and applying the sintering process in a tube furnace. Their surface morphology was characterized using scanning electron microscopy (SEM) and phase homogeneity was confirmed using X-ray diffraction (XRD). Corrosion behavior was determined using immersion and potentiodynamic polarization methods in phosphate buffered saline...
-
Structural Reliability Assessment Of Corroded Tanker Ship Based On Experimentally Estimated Ultimate Strength
PublicationThis work deals with the reliability assessment of a tanker ship hull structure subjected to a vertical bending moment and corrosion degradation. The progressive collapse and ultimate load carrying capacity are estimated based on experimentally tested scaled box-shaped-specimens. The translation of the strength estimate of the scaled specimen to the real tanker ship hull structure is performed based on the dimensional theory developing...
-
Effect of Storage Conditions of Rutile Flux Cored Welding Wires on Properties of Welds
PublicationThe influence of storage locations of two grades of rutile flux cored welding wires on their surface condition and the strength of the welds made with them were studied. Wires were stored in real urban conditions (Gdańsk and Katowice) for 1 month, simultaneously recording changes in conditions: temperature and relative humidity of the environment. Visual tests of wires in the delivered and stored condition as well as visual and...
-
Random field modelling of mechanical behaviour of corroded thin steel plate specimens
PublicationThe objective of this work is to explore the possibility of corrosion degradation modelling of thin steel plate specimens with the use of random field approach. The mechanical properties are obtained via the nonlinear Finite Element Analysis with the use of an explicit dynamic solver. The fully nonlinear material model is adopted to obtain the proper stress-strain response. Sensitivity analysis considering the main statistical...
-
Balanand Santhosh Ph.D.
PeopleDr. Balanand Santhosh, obtained his Ph.D. (cum laude) in Materials, Mechatronics and Systems engineering from the Department of Industrial Engineering, University of Trento, Italy. He is currently working as Research Assistant Professor at Gdansk Univerity of Technology, Poland. Formerly he was working as a post-doctoral researcher at University of Trento, Italy. His research expertise is mainly in the area of ceramic processing...
-
Evaluating and predicting the performance of organic coatings using impedance spectroscopy
PublicationPrzedstawiono wyniki badań cyklicznych, sinusoidalnych zmian temperatury na powłokowe systemy ochronne o skrajnie różnych właściwościach antykorozyjnych. Porównano zachowanie nowej powłoki poliestrowej typu "coil-coating" na ocynkowanej stali uprzednio eksponowanej w warunkach atmosferycznych alkidowej powłoki malarskiej na podłożu stalowym. Badania przeprowadzono przy zastosowaniu techniki spektroskopii impedancyjnej. Stwierdzono...
-
Nanotubular oxide layers and hydroxyapatite coatings on ‘Ti–13Zr–13Nb’ alloy
PublicationThe presented research was aimed to determine the mechanical properties of the nanotubular oxide layer covered with hydroxyapatite coating. The Ti–13Zr–13Nb alloy was oxidised in 1M phosphoric acid with an addition of 0?5% HF for HF solution at 20 V voltage. The electrochemically assisted deposition of hydroxyapatite was performed at cyclic polarisation in NH4H2PO4 and CaCl2 solution at 80uC. The mechanical properties were determined...
-
Transparent thin films of Cu-TiO2 with visible light photocatalytic acitivity
PublicationThin films of Cu–TiO2 with a high level of transparency were prepared by a dip-coating procedure on the glass surface. CuCl2 was used as a copper precursor added during sol – gel synthesis of TiO2. The extension of optical absorption into the visible region of as-prepared thin films was indicated by UV/Vis spectroscopy. Only the anatase phase was detected by X-ray di ffraction analysis (XRD). The presence of copper in the structure...
-
Preparation and characterisation of iron substituted Mn1.7Cu1.3-xFexO4 spinel oxides (x = 0, 0.1, 0.3, 0.5)
PublicationSpinel oxides with the general formula Mn1.7Cu1.3-xFexO4 (x= 0, 0.1, 0.3, 0.5) were prepared and evaluated in this work for their properties at high temperatures. The effect of partially substituting Cu by Fe has not been studied so far for this group of materials and is thus evaluated in this work. Mn1.7Cu1.3-xFexO4 powders were synthesised by a soft chemistry process and studied in terms of crystallographic phase analysis, electrical...
-
Biological properties of chitosan/Eudragit E 100 and chitosan/poly(4-vinylpyridine) coatings electrophoretically deposited on AgNPs-decorated titanium substrate
PublicationThe objective of the study was the determination of the response, in contact with human osteoblast-like MG-63 cells, of electrophoretically deposited coatings composed of chitosan (CS), Eudragit E 100 (EE100), or poly(4- vinylpyridine) (P4VP) on a silver nanoparticle (AgNPs)-decorated titanium substrate. Before deposition, the substrate was coated with silver by electro-reduction of silver nitrate. The coatings deposition was carried...
-
API 5L X65 steel - tensile properties in room temperature -10°C, along rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - CMOD-force record in -10°C, along rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - tensile properties in room temperature +20°C, across rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - tensile properties in room temperature -10°C, across rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - CMOD-force record in -10°C, across rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - tensile properties in room temperature +20°C, along rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - fracture documentation of CMOD-force test in -10°C, along rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - fracture documentation of CMOD-force test in -10°C, across rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
Badania stanu technicznego ścianek szczelnych strony południowej i północnej komory południowej śluzy Dzierżno
PublicationPrace dotyczyły badań nieniszczących łączników (zamków) Paine`a oraz ścianek szczelnych. Ściany boczne komory południowej śluzy Dzierżno zbudowane są ze stalowych pasów blachy o grubości około 16mm i długości 22m połączonych ze sobą wzdłuż dłuższej krawędzi za pomocą zamków Peine`a. System ten umożliwia uzyskanie szczelnego połączenia na całej długości ścianki. Zaawansowany proces korozji spowodował rozszczelnienie połączenia...
-
Types of wear and tear of biomaterials used in orthopaedic surgery
PublicationPurpose of this paper is presentation of observations on different kinds of wear and tear of biomaterials used in contemporary orthopaedic surgery. Types of prosthesis damage, encountered in medical practice, and their causes have been described. Results of many clinical studies were analysed to review prosthesis damage from the stage of implanting (such as intrusion of a foreign object between its components) to their natural...
-
Measurements of flicker noise in supercapacitor cells
PublicationFlicker noise (1/f-like noise) is often used to assess the quality of various materials and devices. This phenomenon has been observed in different electrochemical devices or reactions (e.g., smart windows, pitting corrosion events). In our exploratory studies we consider how to measure and utilize 1/f noise for the quality assessment of supercapacitors. This task requires special attention because of enormous capacitance of the...
-
Condition of Reinforced Concrete Structures and Their Degradation Mechanism at the Former Auschwitz Concentration and Extermination Camp
PublicationThis paper presents the results of investigations on reinforced concrete structures present in the former Auschwitz I and Auschwitz II-Birkenau concentration and extermination camp. Field inspection employing the non-destructive method of reinforcement potential measurement according to the ASTM-C 876–15 standard, followed by laboratory investigations performed on genuine historic reinforced concrete samples collected from the...
-
Degradacja powłokowych systemów ochronnych w zmiennych temperaturach
PublicationPrzedstawiono wyniki badań wpływu cyklicznych sinusoidalnych zmian temperatury na powłokowe systemy ochronne o skrajnie różnych właściwościach antykorozyjnych. Porównano zachowanie nowej powłoki poliestrowej typu "coil-coating" na ocynkowanej stali i uprzednio eksponowanej w warunkach atmosferycznych alkidowej powłoki malarskiej na podłożu stalowym. Badania przeprowadzono przy zastosowaniu techniki spektroskopii impedancyjnej....
-
Diamond protection for reusable ZnO coated fiber-optic measurement head in optoelectrochemical investigation of bisphenol A
PublicationDue to the global problem with plastic contaminating the environment, with bisphenol A (BPA) being one of the highest demand, effective monitoring and purification of the pollutants are required. The electrochemical methods constitute a good solution but, due to polymerization of electrochemical oxidation bisphenol A products and their adsorption to the surfaces, measurement head elements are clogged by the formed film. In this...
-
CLEANING METHODS FOR DUST DEPOSITED ON THE FRONT COVER OF PHOTOVOLTAIC MODULE
PublicationPhotovoltaic modules are one of the renewable energy sources with great potential for application in various regions of the world as well as for different terrain. They are, however, sensitive to external factors, affecting the overall amount of energy generated, such as solar irradiance, shading effects and any form of soil build-up on the front glass cover of solar device. The latter issue happens over a course of weeks, months...
-
The Effect of Welding Conditions on Diffusible Hydrogen Content in Deposited Metal
PublicationThe article presents the results of a literature survey and preliminary tests which set out effects of welding conditions on the amount of diffusible hydrogen in deposited metal. Experiments were conducted by using rutile coated electrodes which generate high contents of diffusible hydrogen in deposited metal. The amount of diffusible hydrogen was determined by a glycerin test.Eleven factors were considered: the electrode angle,...