displaying 1000 best results Help
Search results for: capacitor voltage balancing
-
Low voltage photovoltaic power system
PublicationThe use of photovoltaics is growing rapidly in the industry as well as households. Therefore, educating the public will help them understand solar cell technology, which is becoming more common in everyday life. This paper proposes a demonstrational set-up of photovoltaic panel for the purpose of science education. It was used in numerous outreach activities such as science fairs. Moreover, it proved to be a great tool for education...
-
High - voltage thin - layer fuses
PublicationZaprezentowano nową technologię i konstrukcję bezpieczników wysokonapięciowych wykorzystując technologie stosowane w mikroelektronice. Cienką warstwę topika naniesiono na quasiceramiczne podłoże. Wykonane modele bezpieczników charakteryzują się wysoką pewnością działania oraz małymi stratami I2t.
-
The influence of SVC on the progress of voltage collapse
PublicationThe article presents the simulation concerning the cooperation of SVC circuit with a generative set in time, when of power system reaches low values which may lead to the fall-out of generator from the synchronous operation.
-
Modern Arrangement for Reduction of Voltage Perturbations
PublicationThe contents of this chapter encompass general problems and the most important issues of power-supply-quality improvement in AC systems. In the context of the above, consideration is given to evaluation of bilateral interactions of receivers with an electrical power-distribution system and methods of their reduction. Also are discussed the basis of operation of the most important compensation-filtration devices and their applications...
-
Response of high voltage disconnector under seismic excitation - experimental and numerical study
PublicationThe efficiency of the energetic infrastructure system is a very import safety issue in the region experienced by the ground motion. The aim of the present paper is to show the results of the experimental and numerical study focused on the earthquake-induced response of the high voltage disconnector, which is an important element of energetic network. First, the impact tests as well as the sweep-sine shaking table tests were conducted....
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Analytical comparison between capacitor assisted and diode assisted cascaded quasi-z-source inverters
PublicationQuasi-Z falownik z prostym obwodem impedancyjnym jest bardzo interesującym rozwiązaniem topologicznym ze względu na unikalną możliwość jednostopniowego przekształcanie DC/AC w połączeniu z funkcjami obniżania i podwyższania napięcia. W niektórych aplikacjach jego właściwości podwyższające są jednak niewystarczające. Wyższe napięcie wejściowe można uzyskać w wyniku zastosowania w quasi-Z-falownikach kaskadowych obwodów impedancyjnych....
-
Hybrid stepless distribution transformer with four-quadrant AC/DC/AC converter at low voltage side - simulation tests
PublicationThe article presents the work of the stepless hybrid distribution transformer (HT), as an alternative to the so far applied Automatic Voltage Regulator (AVR) solutions, used to control the voltage in the power system in terms of the fundamental harmonic. The HT is a combination of a conventional distribution transformer and an AC/DC/AC converter connected in series with the transformers secondary winding. In the work the basic...
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublicationA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
A DFT+U study of carbon nanotubes under influence of a gate voltage
PublicationA possibility of appearance of antiferromagnetic ordering in armchair carbon nanotubes and graphene is studied using density functional theory within a DFT+U approach. It is shown that the Coulomb repulsion between electrons in the -orbitals of graphene would need to reach a threshold value of ,...
-
Integrated algorithm for selecting the location and control of energy storage units to improve the voltage level in distribution grids
PublicationThis paper refers to the issue that mainly appears in distribution grids, where renewable energy sources (RES) are widely installed. In such grids, one of the main problems is the coordination of energy production time with demand time, especially if photovoltaic energy sources are present. To face this problem, battery energy storage units (ESU) can be installed. In recent years, more and more attention has been paid to optimizing...
-
Analysis of Ferroresonance Mitigation Effectiveness in Auxiliary Power Systems of High-Voltage Substations
PublicationFerroresonance in power networks is a dangerous phenomenon, which may result in overcurrents and overvoltages, causing damage to power equipment and the faulty operation of protection systems. For this reason, the possibility of the occurrence of ferroresonance has to be identified, and adequate methods need to be incorporated to eliminate or reduce its effects. The aim of this paper is to evaluate the effectiveness of ferroresonance...
-
Numbers, Please: Power- and Voltage-Related Indices in Control of a Turbine-Generator Set
PublicationThis paper discusses the proper selection and interpretation of aggregated control performance indices values mirroring the quality of electrical energy generation by a turbine-generator set cooperating with a power system. Typically, a set of basic/classical and individual indices is used in energy engineering to ensure the mirroring feature and is related to voltage, frequency and active or reactive power deviations from their...
-
Adaptive Algorithm of a Tap-Changer Controller of the Power Transformer Supplying the Radial Network Reducing the Risk of Voltage Collapse
Publicationhe development of renewable energy, including wind farms, photovoltaic farms as well as prosumer installations, and the development of electromobility pose new challenges for network operators. The results of these changes are, among others, the change of network load profiles and load flows determining greater volatility of voltages. Most of the proposed solutions do not assume a change of the transformer regulator algorithm....
-
Frequency measurement research with weight averaging of pulse output signal of voltage-to-frequency converter
PublicationThe paper presents the essence and investigation of the efficiency of weight averaging of a pulse output signal of voltage-to-frequency converter. The effect of counting and the influence of interference on the result of weight averaging of frequency modulated pulses are analyzed. It is shown that from the point of view of counting error reduction, the best are polynomial weight functions. In the case of high interferences whose...
-
Efficient Analysis of Noise Induced in Low-Voltage Installations Placed Inside Buildings with Lightning Protection Systems
PublicationThis paper describes an efficient approach to the broadband analysis of lightning protection systems (LPSs) using the method of moments (MoM) implemented in the frequency domain. The adaptive frequency sampling (AFS) algorithm, based on a rational interpolation of the relevant observable (e.g., voltage, current, electric or magnetic field) which describes the properties of the LPS, is employed to reduce the number of samples computed...
-
Modeling of a Quasi-Resonant DC Link Inverter Dedicated to Common-Mode Voltage and Ground Current Reduction
PublicationIn this paper, the modeling methodology of the AC drive system with a Parallel Quasi-Resonant DC Link Inverter (PQRDCLI) is described. A presented modeling approach is an attractive tool used for the effective evaluation of a common-mode (CM) voltage and grounds current reduction methods. Designed models of inverter, induction machine (IM), and cable are simple, thus the methods for parameter extraction are not complicated. Verification...
-
The Method of Multi-criteria Analysis to Support the Decision on Load or Micro-generation Connection to a Low- or Medium-voltage Power Grid
PublicationThis paper presents a method that supports the decision in terms on selecting the best option of a load connection to a low- or medium-voltage power distribution grid, and of a micro-generation source connection to a low-voltage grid. The method is based on the search for the option with the lowest aggregate assessment measure, which is the weighted average of partial assessment measures determined for each of eight considered...
-
Core/shell structured Ti/Si/C composite for high-performance zinc-ion hybrid capacitor
Publication -
Laboratory tests of medium voltage switchgear isolators
Publication -
Increase of Diagnostic Capabilities of Voltage Fluctuation Indicies
Publication -
The Phenomena of Bursts by Opening Low-Voltage Relay
Publication -
Diagnostics of high-voltage varistors by acoustic emission
PublicationWarystory, szeroko stosowane w ogranicznikach przepięć, powinny być testowane na końcowym etapie ich wytwarzania. Stosowane metody testowania wymagają użycia wysokich napięć i prądów o dużych natężeniach, co jest nidogodne, destrukcyjne i wymaga poboru relatywnie dużych pocy. W artykule zaproponowano zastosowanie analizy sygnału emisji akustycznej do predykcji jakości struktury warystora. Opisano system przygotowany do tej aplikacji,...
-
An improved adaptive neural voltage controller for turbogenerator
PublicationOpracowano model adaptacyjnego neuronowego regulatora napięcia z nastrojonym współczynnikiem wzmocnienia funkcji przynależności i z nastrojonym współczynnikiem uczenia sieci neuronowej w zależnosci od stanu obciążenia turbogeneratora. Przedstawiono wyniki symulacji mające na celu badania efektywności proponowanego regulatora. Te wyniki porównano z wynikami uzyskanymi z regulatorem o stałym współczynnikiem wzmocnienia funkcji przynależności...
-
Predictive Current Control of Voltage-Source Inverter.
PublicationW artykule przedstawiono regulator prądu stojana silnika asynchronicznego z predykcją napiecia wyjściowego. Rozważono aspekty praktycznej realizacji algorytmu w układzie z procesorem sygnałowym związane z opóźnieniami pomiaru prądu przy zastosowaniu przetwornika A/C. Układ zrealizowano praktycznie przy wykorzystaniu układu FPGA. W pracy zamieszczono wyniki badań symulacyjnychi eksperymentalnych.
-
Problems of exact generation ofinverter output voltage
PublicationW pracy przedstawiono nową modyfikację modulatora szerokości impulsów. Rozważono problemy generacji dokładnej wartości napięcia wyjściowego falownika. Zaproponowano dwie metody generacji małej wartości napięcia.
-
Electrical safety in low-voltage DC microgrids with B-type residual current devices
PublicationResidual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...
-
Unidirectional DC/DC Converter with Voltage Inverter for Fast Charging of Electric Vehicle Batteries
PublicationThe paper proposes the adaptation of the industrial plant’s power network to supply electric vehicle (EV) fast-charging converters (above 300 kW) using renewable energy sources (RESs). A 600 V DC microgrid was used to supply energy from RESs for the needs of variable speed motor drives and charging of EV batteries. It has been shown that it is possible to support the supply of drive voltage frequency converters (VFCs) and charging...
-
Comparative Study of Balancing SRT by Using Modified ASM2d in Control and Operation Strategy at Full-Scale WWTP
PublicationDetailed knowledge on the composition of the influent going into the wastewater treatment system is essential for the development of a reliable computer model. In the context of WWTPs (wastewater treatment plants), the wastewater characteristics are not only important for activated sludge system modelling, but also have an impact on the appropriate control of single unit operations. The aim of this study was to evaluate the concepts...
-
Magnetic and capacitive couplings influence on power and energy measurement in double circuit high voltage overhead transmission line
PublicationThe paper discusses influence of magnetic and capacitive couplings on power and energy measurement in case of double circuit high voltage overhead transmission line. There are presented and discussed various factors influencing the power flow among the line‟s circuits. Mathematical model based calculations results are compared to the real transmission line measurements.
-
High Voltage
Journals -
The harmonic distortion of voltage waveforms in the ship's electrical power system
Open Research DataThe dataset is a part of the research results on the quality of supply voltage on bus bars of the ship's electrical power system's main switchboard in different states of ship exploitation. The attached dataset contains the results of a harmonic distortion analysis expressed by the total harmonic distortion (THD) coefficient of voltage waveforms recorded...
-
Closed-Loop Control System Design for Wireless Charging of Low-Voltage EV Batteries with Time-Delay Constraints
PublicationThis paper presents an inductive power transfer system on the basis of a double single- phase three-level T-type inverter and two split transmitting coils for constant current and constant voltage wireless charging of low-voltage light electric vehicle batteries with closed-loop control, considering time-delay communication constraints. An optimal control structure and a modified control strategy were chosen and implemented to...
-
On performance limits of switched-capacitor multi-phase charge pump circuits. Remarks on papers of Starzyk et al.
PublicationW pracy zweryfikowano hipotezę Starzyka nt. maksymalnego, osiągalnego wzmocnienia napięciowego w wielotaktowym konwerterze napięcia stałego typu C-przełączane (w tzw. pompie ładunkowej). W konwerterze zbudowanym z k kondensatorów maksymalne wzmocnienie określone jest przez odpowiednią potęgę liczby 2 tj. 2^(k-1) przy czym warunek podany przez Starzyka jest konieczny lecz nie jest dostateczny. Podano warunki konieczne i dostateczne...
-
Controllable Carbonization of Plastic Waste into Three-Dimensional Porous Carbon Nanosheets by Combined Catalyst for High Performance Capacitor
Publication -
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Structure and the space vector modulation for a medium-voltage power-electronic-transformer based on two seven-level cascade H-bridge inverters
PublicationThis study presents the structure and the space vector pulse-width modulation (SVPWM) for power electronic transformer (PET) based on two seven-level cascade H-bridge (CHB) inverters. The DC links of CHB inverters are coupled with nine dual-active bridge (DAB) converters with medium-frequency transformers. The DC-link voltages are equalised with two methods – through the control of DAB voltages...
-
Optimization of Division and Reconfiguration Locations of the Medium-Voltage Power Grid Based on Forecasting the Level of Load and Generation from Renewable Energy Sources
PublicationThe article addresses challenges in optimizing the operation of medium voltage networks, emphasizing optimizing network division points and selecting the best network configuration for minimizing power and energy losses. It critically reviews recent research on the issue of network configuration optimization. The optimization of the medium voltage power grid reconfiguration process was carried out using known optimization tools....
-
Estimation of Parameters Associated With Individual Sources of Voltage Fluctuations
Publication -
Adaptive neural voltage controller with tunable activation gain
PublicationW artykule przedstawiono model adaptacyjnego neuronowego regulatora napięcia dla turbogeneratora z nastrojonym współczynnikiem wzmocnienia funkcji przynależności. Ten model jest kombinacją klasycznego neuronowego modelu i neuronowego modelu z współczynnikiem wzmocnienia funkcji przynależności zależnym od warunków pracy obiektu.Przedstawiono, także wyniki symulacji mające na celu badania efektywności proponowanego regulatora dla...
-
Results of electrical voltage measurements in reactors - part 1
Open Research DataResults of electric voltage measurements in six reactors using various plantings. These are the results of the project: Integrated approach 3M (Macrophytes-Microbiome-Modelling) to elucidate mechanisms of bioenergy production and micropollutants transformation in Floating Treatment Wetlands combined with Microbial Fuel Cells.
-
Increasing the Utilization of dc-link Voltage of a Five-Leg VSI Based on Rotor Angle Control of Dual Induction Motors
PublicationThis paper introduces an increased utilization of the dc-link voltage of a five-leg voltage source inverter (VSI) based on the rotor flux angle control technique for dual induction motors, IM. The main purpose is to utilize additional abilities provided by a multi-motor drive system in limited operating conditions. Generally, a multi-motor drive system is widely used in electric vehicles (EVs), traction systems and in several industrial...
-
Low-Voltage Low-Power Filters with Independent ω0 and Q Tuning for Electronic Cochlea Applications
PublicationAn acoustic second-order low-pass filter is proposed for filter banks emulating the operation of a human cochlea. By using a special filter structure and an innovative quality (Q)-factor tuning technique, an independent change of the cutoff frequency (ω0) and the Q-factor with unchanged gain at low frequencies is achieved in this filter. The techniques applied result in a simple filter design with low Q-factor sensitivity to component...
-
The statistic properties of rms voltage and frequency in the ship's electrical power system
Open Research DataThe dataset is a part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the results of a statistical analysis of rms voltage and frequency in the ship's electrical power system. The following statistical...
-
A new concept of PWM duty cycle computation using the Barycentric Coordinates in a Three-Dimensional voltage vectors arrangement
PublicationThe paper presents a novel approach to the Pulse Width Modulation (PWM) duty cycle computing for complex or irregular voltage vector arrangements in the two (2D) and three–dimensional (3D) Cartesian coordinate systems. The given vectors arrangement can be built using at least three vectors or collections with variable number of involved vectors (i.e. virtual vectors). Graphically, these vectors form a convex figure, in particular,...
-
Calculation Program Supporting Switched Capacitor DC-DC Charge Pump Design (CP Design Calculator) - PartI: Preface
PublicationPrzedmiot badań i motywy podjęcia pracy. Metoda badawcza. Nota historyczna nt. konwertera Fibonacciego (Fibonacci multiplier) i pompy ładunkowej Makowskiego ("Makowski charge pump"). Przewidywane cele pracy. Podziękowania
-
Evaluation of foil capacitor nonlinearities and flucuations during manufacturingoszacowanie nieliniowości i fluktuacji kondensatorów foliowych w procesie produkcyjnym.
PublicationPrzedstawiono dwa podejścia do problemów niezawodności elementów elektronicznych. Opisano mierzone przeciwzakłóceniowe kondensatory foliowe produkowane przez MIFLEX (Kutno), zasadę i układ do pomiaru wskaźnika trzeciej harmonicznej sygnału pobudzającego oraz jego zależność od parametrów mierzonego elementu. Przedstawiono wyniki statystyczne pomiaru parametrów funkcjonalnych oraz trzeciej harmonicznej próbek tych kondensatorów przed...
-
Evaluation of foil capacitor nonlinearities and fluctuations during manufacturingOszacowanie nieliniowości i fluktuacji kondensatorów foliowych w procesie produkcyjnym
PublicationPrzeanalizowano nieliniowości i właściwości szumowe kondensatorów w celu ustalenie kryteriów testowania nieniszczącego i selekcji kondensatorów przeciwzakłóceniowych do różnych klas trwałości i niezawodności. Przedstawiono wybrane wyniki eksperymentalne pomiaru kondensatorów produkowanych przez ZR MIFLEX w Kutnie oraz koncepcję systemu pomiarowego przeznaczonego do implementacji tych pomiarów w procesie produkcyjnym.
-
Reducing of energy consumption in public transport - results of experimental exploitation of super capacitor energy bank in Gdynia trolleybus system
PublicationPaper presents the result of test exploitation supercapacitor energy bank in Gdynia trolleybus system. In the first part of the article the basics of the regenerative breaking are presented and the construction and control strategy of the supercapacitor bank are described. The area of research and method of measurement are explained. In the second part of paper the results of tests and measurements are described. Emphasis was placed...
-
Balancing energy consumption in limited power grid with active front-end and three phase dual active bridge system
PublicationPaper deals with simulation analysis of bidirectional power converters system for charging station of electric vehicle in condition of limited power source in city infrastructure. In case of incapability to provide additional power supply through the grid by virtue of historical, architectural and economic reasons it is possible to solve this issue by implementation of mobile battery-powered supply source. The proposed bidirectional...