displaying 1000 best results Help
Search results for: allergy to implant components
-
IN VIVO DEGRADATION OF BIOMATERIALS
PublicationThe material designed to be introduced into the human tissue should be biocompatible and biofunctional. Unless it is so, the body may respond to the implant in different ways. An inflammation reaction may appear such as: parting of items of the implant surface resulting from fraction or pressure. The condition of the surface has an important influence on the usefulness of the implant. The required values depend on the implant function...
-
Biomateriały ETI 2023/24
e-Learning CoursesMateriały na implanty, powłoki, reakcje na granicy implant-tkanka, nanocząstki, degradacja.
-
Can matrix solid phase dispersion (MSPD) be more simplified? Application of solventless MSPD sample preparation method for GC–MS and GC–FID analysis of plant essential oil components
Publication -
Modeling the debonding process of osseointegrated implants due to coupled adhesion and friction
PublicationCementless implants have become widely used for total hip replacement surgery. The long-term stability of these implants is achieved by bone growing around and into the rough surface of the implant, a process called osseointegration. However, debonding of the bone–implant interface can still occur due to aseptic implant loosening and insufficient osseointegration, which may have dramatic consequences. The aim of this work is to...
-
Debonding of coin-shaped osseointegrated implants: Coupling of experimental and numerical approaches
PublicationWhile cementless implants are now widely used clinically, implant debonding still occur and is difficult to anticipate. Assessing the biomechanical strength of the bone–implant interface can help improving the understanding of osseointegration phenomena and thus preventing surgical failures. A dedicated and standardized implant model was considered. The samples were tested using a mode III cleavage device to assess the mechanical...
-
Biomateriały IBM
e-Learning CoursesMateriały biomedyczne i biomimetyczne. Materiały metalowe, ceramiczne, polimerowe. Reakcje na granicy tkanka-implant.
-
Two-criteria optimisation problem for ventral hernia repair
PublicationTwo-criteria optimisation problem related to laparoscopic ventral hernia repair is formulated in this paper. An optimal implant from a given set and its orientation is sought. The implant is subjected to kinematic extortions due to a patient’s body movement and intra-abdominal pressure. The first criterion of the optimisation problem deals with the reaction force in the implant fastener, while the deflection of the implant constitutes...
-
Journal of Allergy and Clinical Immunology-In Practice
Journals -
SIMULATION OF PROCEED® SURGICAL MESH APPLIED TO VENTRAL HERNIA REPAIR
PublicationIn the present research, Proceed® implant is considered. The system is subjected to short-time dynamic pressure load, similar to post-operative cough naturally occurring in human abdomen. The model refers to a clinical case of 5cm of hernia operated by Proceed implant fixed by 15 joints every 3cm around the orifice. The simulations of the implanted mesh are performed by means of the Finite Element Method. The implant is modelled...
-
The problem of infections associated with implants – an overview
PublicationImplant-associated infections are serious and relatively common complication that leads to implant loss. The purpose of this paper is to gather knowledge about this issue. A literature review of the epidemiology, risk factors and pathogenesis of infections related to implants was carried out. This position collects data on commonly used implants and infections associated with them from various fields of medicine and contains classifications...
-
Determinants of the primary stability of cementless acetabular cup implants: A 3D finite element study
PublicationPrimary stability of cementless implants is crucial for the surgical success and long–term stability. However, primary stability is difficult to quantify in vivo and the biomechanical phenomena occurring during the press–fit insertion of an acetabular cup (AC) implant are still poorly understood. The aim of this study is to investigate the influence of the cortical and trabecular bone Young's moduli Ec and Et, the interference...
-
Zero-Pole Electromagnetic Optimization
PublicationA fast technique for the full-wave optimization of transmission or reflection properties of general linear timeinvariant high-frequency components is proposed. The method is based on the zeros and poles of the rational function representing the scattering parameters of the device being designed and it is the generalization of the technique developed for the design by optimization of microwave filters. The performance of the proposed...
-
Towards Understanding of Mechanics of Hernia Managed by Synthetic Mesh in Laparoscopic Operation: A Single Case Study
PublicationIn this paper a research towards understanding of mechanics of ventral hernia operated with the use of Physiomesh Open image in new window implant and SecureStrap Open image in new window staples is described. Experimental and numerical studies are conducted for that purpose. Experimental works cover uni-axial tension tests of the implant samples and of the implant-staples-tissue system. Also experiments on implant-staples-tissue...
-
Biological and mechanical properties of bone cement with nanoparticles - in vivo and in vitro research
PublicationDespite antibiotics preventive treatment, before and after an implant implementation, risk of infection are real. These infections at the implant surface develop in a few months after applying them into the body. To prevent the development of bacteria and to reduce the risk of infection, implants coated with nanoparticles come into use. The Mechanical Department of the Technical University of Gdańsk carried out a research with...
-
Electrophoretic Deposition of Chitosan/Eudragit E 100/AgNPs Coatings for Controlled Release of Antibacterial Substance
PublicationThe development of bacterial infection of the tissues surrounding an implant is one of the leading causes of implant surgery failure. In order to prevent the deposition of bacteria on the implant surface and the formation of biofilm, coatings that exhibit antibacterial properties are manufactured. However, the problem is the controlled release of the therapeutic substance from the coating over the extended life of the implant [1],...
-
Underwater welded joint properties investigation
PublicationPrzeprowadzono badania mikro- i makroskopowe złączy spawanych typu implant wykonanych pod wodą metodą lokalnej komory suchej. Wyniki badań świadczą o tym, że w SWC badanych złączy tworzą się kruche struktury hartownicze, które są odpowiedzialne za zwiększoną skłonność stali o podwyższonej wytrzymałości do tworzenia pęknieć zimnych. Analiza rozkładów twardości złączy implant również potwierdza istnienie szkodliwego wpływu środowiska...
-
Biological and mechanical properties of bone cement with nanoarticles - in vitro and in vivo research
PublicationDespite antibiotic preventive treatment both before and after implant implementation, the risks of infection are real. These infections develop at the implant surface a few months after inserting them into the body. To prevent the development of bacteria and reduce the risk of infection, implants coated with nanoparticles are used. The Mechanical Department of the Technical University of Gdansk carries out research into using bone...
-
Nanotubular oxide layer formed on helix surfaces of dental screw implants - SEM examination
Open Research DataThe samples used for the research had the shape of a helix with a metric thread, with their geometry imitating a dental implant. The oxide layer was produced by a standard electrochemical method in an environment of 1M H3PO4 + 0.3 % HF for 20 min, at a constant voltage of 30 V. The oxidized samples were analyzed with a scanning electron microscope.
-
Metal implants in ostheosynthesis - construction solutions, materials and applications
PublicationThe aim of the article is to present two case studies on intramedullary nails. The research included the evaluation of the type of fracture and the analysis of microstructure, chemical composition and hardness of the implant material.
-
Infection with SARS‐CoV‐2 among children with asthma: evidence from Global Asthma Network
Publication -
Allergic diseases and respiratory symptoms in urban and rural children in Grodno Region (Belarus)
Publication -
Recurrent assessment of lymphocyte subsets in 32 patients with multisystem inflammatory syndrome in children (MIS‐C)
Publication -
Mechanical compatibility of implants used in hernia repair with abdominal wall
PublicationThe paper deals with a membrane model of a synthetic surgical mesh for treatment of abdominal hernia. The authors analyse the compatibility of two implant types with the human wall: Dualmesh Gore and Proceed. The finite element method is applied to simulate tjhe behavior of the proposed model. Due fact that recurrences are usually caused by connection failure, this study is focused on reaction forces in supports representing the...
-
The degradation of metal implants
PublicationThe presence of metal implants in the human body causes some dangers, which result from introducing another object into organism. There may occur a biocorrosion, which causes different modifications of implant surface.
-
Piotr Krajewski dr
PeoplePiotr Krajewski is a librarian at the Library of Gdańsk University of Technology (GUT) and a PhD student at the Medical University of Gdańsk. His research interests focus on the standardization of the e-resources usage data and Open Access publishing, especially the role of institutional repositories in the development of the OA initiative and the phenomenon of “predatory publishers”. He works at Scientific and Technical Information...
-
Electrophoretically Deposited Chitosan/Eudragit E 100/AgNPs Composite Coatings on Titanium Substrate as a Silver Release System
PublicationDue to the possibility of bacterial infections occurring around peri-implant tissues, it is necessary to provide implant coatings that release antibacterial substances. The scientific goal of this paper was to produce by electrophoretic deposition (EPD) a smart, chitosan/Eudragit E 100/silver nanoparticles (chit/EE100/AgNPs) composite coating on the surface of titanium grade 2 using different deposition parameters, such as the...
-
Operational Research - Queuing Systems 2022
e-Learning CoursesComponents, characteristics, classification, analysis, and applications of queuing systems.
-
Fundamentals of Electrotechnics and Electronics II - project China [EE][2024/25]
e-Learning CoursesIntroduction and analysis of fundamental electronic components, circuits and applications.
-
Fundamentals of Electrical Engineering and Electronics 2 [EE][2024/25]
e-Learning CoursesIntroduction and analysis of fundamental electronic components, circuits and applications.
-
Fundamentals of Electrotechnics and Electronics II - project China [2023/24]
e-Learning CoursesIntroduction and analysis of fundamental electronic components, circuits and applications.
-
Determination of heavy metals in eyeshadows from China
PublicationPersonal care products and cosmetics are used daily by many people, causing local exposure to certain chemical substances through the application directly inside the oral cavity, on the skin, lips, eyes, and mucosa. Eyeshadows are among the most commonly used types of cosmetics. According to scientifc reports, they may contain heavy metals, especially in non-original products. The exposure to said heavy metals may cause local skin...
-
Antibacterial Activity and Cytocompatibility of Bone Cement Enriched with Antibiotic, Nanosilver, and Nanocopper for Bone Regeneration
PublicationBacterial infections due to bone replacement surgeries require modifications of bone cement with antibacterial components. This study aimed to investigate whether the incorporation of gentamicin or nanometals into bone cement may reduce and to what extent bacterial growth without the loss of overall cytocompatibility and adverse effects in vitro. The bone cement Cemex was used as the base material, modified either with gentamicin...
-
Operational Research - Queuing Systems 2024
e-Learning CoursesCourse discusses components, characteristics, classification, analysis, and applications of queuing systems.
-
Operational Research - Queuing Systems 2024
e-Learning CoursesCourse discusses components, characteristics, classification, analysis, and applications of queuing systems.
-
Operational Research 2024
e-Learning CoursesCourse discusses components, characteristics, classification, analysis, and applications of queuing systems.
-
Janusz Smulko prof. dr hab. inż.
PeopleHe was born on April 25, 1964 in Kolno. He graduated in 1989 with honors from the Faculty of Electronics at Gdańsk University of Technology, specialising in measuring instruments. In 1989 he took second place in the Red Rose competition for the best student in the Pomerania Region. Since the beginning of his career ha has been associated with Gdańsk University of Technology: research assistant (1989-1996), Assistant Professor (1996-2012),...
-
Hip endhoprothesis development using rapid prototyping methods
PublicationIntegrated product development based on Rapid Prototyping methods, connected with computer aided 3D design and computer aided engineering enables fast and full new product verification and validation. A case study derived from clinical and technological practice using hip implant construction is also included.
-
Forming of the gap in tendon sutures with the Kessler suture
Open Research DataThe main objective of the all study was to assess the load capacity of a new implant device for knotless tendon anastomosis. During this series of experiments the gap formation process between the fronts of the connected tendons was observed. Tendons from fresh swine legs (commercially available) served as the biological material. The tendon juncture...
-
Skłonność złączy wykonanych pod wodą do tworzenia pęknięć zimnych
PublicationPrzedmiotem pracy jest analiza stanu wiedzy dotyczącej skłonności do tworzenia peknięć zimnych złączy wykonanych pod wodą. Omówiono wpływ warunków spawania na czynniki będące przyczyną pękania. Przedstawiono wyniki badań złączy ze stali o podwyższonej wytrzymałości metodą implant.
-
Nanotubular oxide layers and hydroxyapatite coatings on porous titanium alloy Ti13Nb13Zr
PublicationThe surface condition of an implant has a significant impact on response occurring at the implant-biosystem border. The knowledge of physical-chemical and biological processes allows for targeted modification of biomaterials to induce a specified response of a tissue. The present research was aimed at development of technology composing of obtaining the nanotube oxide layers on a porous titanium alloy Ti13Nb13Zr, followed by the...
-
Structural changes of bacterial cellulose due to incubation in conditions simulating human plasma in the presence of selected pathogens
PublicationBacterial nanocellulose (BNC) is a natural biomaterial with a wide range of medical applications. However, it cannot be used as a biological implant of the circulatory system without checking whether it is biodegradable under human plasma conditions. This work aimed to investigate the BNC biodegradation by selected pathogens under conditions simulating human plasma. The BNC was incubated in simulated biological fluids with or...
-
Janusz Datta prof. dr hab. inż.
PeopleIn 1988, Janusz Datta finished his studies at the Gdańsk University of Technology (GUT), Faculty of Chemistry. Since then he has been employed at the Faculty of Chemistry in the Department of Polymer Technology. During the first six years of employement he was worked as a scientist. In this period, he travelled extensively to ZACHEM company located in Bydgoszcz to gain practical experience related to chemical processing. In 1994,...
-
Effect of welding conditions on susceptibility to cold cracking of underwater welded joints
PublicationPrzedstawiono wybrane aspekty spawalności stali przy spawaniu pod wodą metodą lokalnej komory suchej. Zwrócono szczególną uwagę na skłonność do tworzenia peknięć zimnych w SWC. Przy pomocy planowania doświadczeń określono ilościowy wpływ parametrów spawania na naprężenia krytyczne z próby implant.
-
Experimental database of 3D lattice structure scaffolds testing
Open Research DataDataset contains results of validation (experimental testing) of 3D lattice scaffolds proposed in the paper "Mathematical approach to design 3D scaffolds for the 3D printable bone implant". There are presented three series of experimental testing for each of seven tested scaffolds:
-
Forming of the gap in tendon sutures with an anchor without a pin
Open Research DataThe main objective of the all study was to assess the load capacity of a new implant device for knotless tendon anastomosis. During this series of experiments the gap formation process between the fronts of the connected tendons was observed. Tendons from fresh swine legs (commercially available) served as the biological material. The tendon juncture...
-
Forming of the gap in tendon sutures with an anchor with a pin
Open Research DataThe main objective of the all study was to assess the load capacity of a new implant device for knotless tendon anastomosis. During this series of experiments the gap formation process between the fronts of the connected tendons was observed. Tendons from fresh swine legs (commercially available) served as the biological material. The tendon juncture...
-
Maximum forces in tendon connections for an anchor with a pin in the full sample experiment
Open Research DataThe main objective of the all study was to assess the load capacity of a new implant device for knotless tendon anastomosis. During this series of experiments the load capacity of the anchoring element with a pin (see figure 1) was examined. Tendons from fresh swine legs (commercially available) served as the biological material. All samples were subjected...
-
HLA Status in Patients with Chronic Spontaneous Urticaria
Publication -
Does the Aberrant Expression of CD2 and CD25 by Skin Mast Cells Truly Correlate with Systemic Involvement in Patients Presenting with Mastocytosis in the Skin?
Publication -
BJS-03 DO WE NEED FIXATION OF THE MESH IN LAPAROENDOSCOPIC TECHNIQUES FOR M3 INGUINAL DEFECTS? AN EXPERIMENTAL STUDY
PublicationThe authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials. The results showed that mesh fixation is not the only alternative to preventing recurrence in complex defects and that the type of implant seems to be a key factor from the point of view of mechanics and biophysics.