Search results for: NONLINEAR CONTROL WASTEWATER TREATMENT PLANT
-
Supervised model predictive control of wastewater treatment plant
PublicationAn optimizing control of a wastewater treatment plant (WWTP), allowing for cost savings over long time period and fulfilling effluent discharge limits at the same time, requires application of advanced control techniques. Model Predictive Control (MPC) is a very suitable control technology for a synthesis of such a truly multivariable controller that can handle constraints and accommodate model-based knowledge combined with hard...
-
Model of aeration system at biological wastewater treatment plant for control design purposes
PublicationThe wastewater treatment plant (WWTP) is a dynamic, very complex system, in which the most important control parameter is the dissolved oxygen (DO) con-centration. The air is supplied to biological WWTP by the aeration system. Aera-tion is an important and expensive activity in WWTP. The aeration of sewage ful-fils a twofold role. Firstly, oxygen is provided as the main component for biolog-ical processes. Secondly, it supports...
-
Application of fuzzy neural network for supporting measurements and control in a wastewater treatment plant
PublicationOczyszczanie ścieków jest jednym z ważniejszych aspektów ochrony środowiska. Nowoczesne systemy kontroli w oczyszczalniach ścieków pozwalają na poprawę jakości procesu oczyszczania redukując jednocześnie koszty. Systemy kontroli i optymalizacji jakie odkilku lat opracowuje się dla oczyszczalni ścieków, bazują zazwyczaj na skomplikowanych modelach matematycznych. Kluczowym problemem w zastosowaniu tych systemów jest duża liczba...
-
Modelling of wastewater treatment plant for monitoring and control purposes by state - space wavelet networks
PublicationMost of industrial processes are nonlinear, not stationary, and dynamical with at least few different time scales in their internal dynamics and hardly measured states. A biological wastewater treatment plant falls into this category. The paper considers modelling such processes for monitorning and control purposes by using State - Space Wavelet Neural Networks (SSWN). The modelling method is illustrated based on bioreactors of...
-
Multiregional PI control strategy for dissolved oxygen and aeration system control at biological wastewater treatment plant
PublicationThe dissolved oxygen is a key parameter for biological processes at wastewater treatment plant. The dissolved oxygen tracking problem is one of the most complex and fundamental issue of biological processes. The paper proposes a new multiregional control strategy for dissolved oxygen tracking problem. The aeration system is included in overall control structure. The control mechanism within the operating point area is based on...
-
Respiration rate estimation for model predictive control of dissolved oxygen in wastewater treatment plant
PublicationRespiration rate is very important parameter for biological processes in wastewater treatment plant (WWTP). The sequential algorithm for estimate the respiration rate is proposed and investigated. The Kalman filter (KF) is used. Simulation tests for the benchmark WWTP are presented.Respiracja jest bardzo ważnym parametrem dla prawidłowego przebiegu procesów biologicznych w oczyszczalni ścieków. W artykule przedstawiono i zbadano...
-
Stochastic optimisation algorithm for optimisation of controller parameters for control of dissolved oxygen in wastewater treatment plant
PublicationWastewater treatment plants (WWTPs) are very important facilities for mankind. They enable the removal and neutralisation of man-made pollutants. Therefore, it is important for wastewater treatment plants to operate as efficiently as possible so that the level of pollutants in the treated wastewater meets specific requirements. This paper concerns the design of a hierarchical nonlinear adaptive control system for dissolved oxygen...
-
Supervisory Control System for Adaptive Phase and Work Cycle Management of Sequencing Wastewater Treatment Plant
PublicationThe paper presents the design of the integrated control system applied to Sequencing Batch Reactor (SBR) in a biological Wastewater Treatment Plant (WWTP) in Swarzewo, which operates under activated sludge technology. Based on the real data records, ASM2d biological processes model and aeration system model, hierarchical control system for dissolved oxygen tracking and cycle management is designed. Internal Model Controller (IMC)...
-
The hybrid estimation algorithm for wastewater treatment plant robust model predictive control purposes at medium time scale
PublicationThe paper proposes an approach to designing the hybrid estimation algorithm/module (HEA) with moving measurements window for Wastewater Treatment Plant (WWTP) Robust Model Predictive Control (RMPC) purposes at medium time scale. The RMPC uses a dedicated grey-box model of biological reactor for the system outputs prediction purposes. The grey-box model parameters are dependant on the plant operating point. Hence, these parameters...
-
Estimation of wastewater treatment plant state for model predictive control of N-P remowal at medium time scale.
PublicationPrzy ograniczonych możliwościach pomiarowych estymaty stanu są potrzebne w sterowaniu optymalizującym, opartym na sterowaniu predykcyjnym, sterującym usuwaniem azotu i fosforu, w biologicznej oczyszczalni ścieków. Optymalizator MPC do implementacji sprzężenia zwrotnego z obiektu potrzebuje tych estymat. Dodatkowo aktualizowane muszą być parametry modelu Gray-Box wykorzystywanego w module MPC. Wtedy estymaty stanu są używane przez...
-
Optimizing Control of Wastewater Treatment Plant With Reinforcement Learning: Technical Evaluation of Twin-Delayed Deep Deterministic Policy Gradient Agent
PublicationControl of the wastewater treatment processes presents significant challenges due to the fluctuating nature of inflow and wastewater composition, alongside the system’s non-linear dynamics. Traditional control methods struggle to adapt to these variations, leading to an economically suboptimal operation of the process and a violation of norms imposed on the quality of wastewater discharged to the catchment area. This study proposes...
-
Set-Bounded joined parameter and state estimation for model predictive control of integrated wastewater treatment plant systems at medium time scale.
PublicationW artykule opisano moduł łącznej estymacji w postaci zbiorów ograniczonych (ang. set-bounded) parametrów i stanu systemu dla potrzeb sterowania predykcyjnego zintegrowanym systemem ściekowym w średniej skali czasu. Jest to jeden ze składowych elementów Inteligentnej Hierarchicznej Struktury Sterowania opracowanej w celu pokonania następujących problemów, które występują w kontrolowanym systemie: różne skale czasowe procesów, silnie...
-
Novel hierarchical nonlinear control algorithm to improve dissolved oxygen control in biological WWTP
PublicationWastewater treatment is a problem known to humankind for centuries. The quality of treated sewage determines the condition of reservoirs around the world. Control of such a complex and nonlinear system as a wastewater treatment plant requires thorough knowledge of the process. The paper presents a hierarchical control system of a Sequencing Batch Reactor (SBR) in Wastewater Treatment Plant (WWTP) taking into account a model based...
-
Mixed integer nonlinear optimization of biological processes in wastewater sequencing batch reactor
PublicationWastewater treatment plays a key role for humanity. The waste entering lakes, rivers, and seas deteriorates daily quality of life. Therefore, it is very important to improve the efficiency of wastewater treatment. From a control point of view, a biological wastewater treatment plant is a complex, non-linear, multidimensional, hybrid control system. The paper presents the design of the optimizing hierarchical control system applied...
-
Comparison of Two Nonlinear Predictive Control Algorithms for Dissolved Oxygen Tracking Problem at WWTP
PublicationThe wastewater treatment plant is classified as a complex system, due to its nonlinear dynamics, large uncertainty of disturbance inputs, multiple time scales in the internal process dynamics, and multivariable structure. The aeration process, in turn, is an important and expensive part of wastewater treatment plant operation. All operating parameters of the aeration in biological processes are to be precisely controlled to provide...
-
Employment of a Nonlinear Adaptive Control System for Improved Control of Dissolved Oxygen in Sequencing Batch Reactor
PublicationA proper control in a complex system, such as Wastewater Treatment Plant (WWTP) with each year is becoming increasingly important. High quality control can minimize an environmental impact as well as reduce operational costs of the WWTP. One of the core issues is providing adequate dissolved oxygen (DO) concetration for microorganisms used in a treatment process. An aeration process of the wastewater realised by an system consisting...
-
Nonlinear fuzzy control of the dissolved oxygen in activated sludge processes
PublicationWastewater treatment plant is generally a complex, multivariable, time varying and nonlinear large scale industrial system. Moreover, interactions between the components are very strong. The dissolved oxygen tracking problem is one of the most complex and fundamental issues of biological processes. Air for the aerated tanks is supplied by aeration system (blowers, pipes, diffusers). It is a complex dynamic system. The new control...
-
Anaerobic bacteria in wastewater treatment plant
Publication -
Model based evaluation of plant improvement at a large wastewater treatment plant (WWTP)
PublicationIn this work, the effect of the improvement carried out at a large-scale wastewater treatment plant (WWTP) was evaluated, by means of modelling works, with the aim to determine the influence of the modernization over the process performance. After modernization, the energy consumption due to the aeration decreased about a 20% maintaining the effluent quality. In order to double-check the good effluent quality, modelling works were...
-
Nonlinear Fuzzy Control System for Dissolved Oxygen with Aeration System in Sequencing Batch Reactor
PublicationBiological processes at a wastewater treatment plant are complex, multivariable, time varying and nonlinear. Moreover, interactions between the components are very strong. Control of dissolved oxygen is one of most important task at the plant. The level of dissolved oxygen in aerobic tanks has significant influence on behaviour and activity of microorganisms at the plant. Air for aerated tanks is supplied by the aeration system...
-
Assessment of wastewater quality indicators for wastewater treatment influent using an advanced logistic regression model
PublicationInfluent quality indicators play a significant role in wastewater treatment plant performance due to their correlation with reactor operations and effluent quality. However, selecting a specific/best parameter indicator for predicting influent wastewater quality is one of the challenges in wastewa- ter treatment. This study, therefore, focused on determining suitable variables as influent quality indicators. For this purpose, a...
-
Microorganisms in the air over wastewater treatment plant.
PublicationCelem pracy było aktywności źródeł emisji mikroorganizmów do powietrza na terenie oczyszczalni ścieków. Stwierdzono iż najwyższe liczebności bakterii występowały w rejonie piaskowników i komór recyrkulacji osadu czynnego. Natomiast liczba bakterii w rejonie komór napowietrzania była zbliżona do tła.
-
Mathematical Modelling in Diagnosis of Wastewater Treatment Plant
PublicationThe paper reports development of mathematical modeling in diagnosis of the WWTP. The algorithm is based on a comparition of data from the mathematical modeling and measurments of real datefrom WWTP, until it will detect any malfunction of the sensors in th case of study.
-
Antimicrobial resistance of fecal indicators in muncipal wastewater treatment plant
PublicationAntimicrobial resistance of fecal coliforms (n = 153) and enterococci (n = 199) isolates was investigated in municipal wastewater treatment plant (WWTP) based on activated sludge system. The number of fecal indicators (in influent and effluent as well as in the aeration chamber and in return activated sludge mixture) was determined using selective media. Susceptibility of selected strains was tested against 19 (aminoglycosides,...
-
Prediction of Wastewater Quality at a Wastewater Treatment Plant Inlet Using a System Based on Machine Learning Methods
PublicationOne of the important factors determining the biochemical processes in bioreactors is the quality of the wastewater inflow to the wastewater treatment plant (WWTP). Information on the quality of wastewater, sufficiently in advance, makes it possible to properly select bioreactor settings to obtain optimal process conditions. This paper presents the use of classification models to predict the variability of wastewater quality at...
-
A Model-Based Improved Control of Dissolved Oxygen Concentration in Sequencing Wastewater Batch Reactor
PublicationBiochemical processes at wastewater treatment plant are complex, nonlinear, time varying and multivariable. Moreover, relationships between processes are very strong. One of the most important issues is exerting proper control over dissolved oxygen levels during nitrification phase. This parameter has a very large impact on activity of microorganisms in activated sludge and on quality of pollution removal processes. Oxygen is supplied...
-
Influence of landfill leachate on municipal wastewater treatment - model plant(WWTP-MP)
PublicationAbstract In the current study, wastewater treatment model plant (WWTP-MP) was used to investigate the possibilities of landfill leachate co-treatment together with municipal wastewater. The WWT-MP, designed as an A2O multiphase system, was fed with the raw municipal wastewater (from the WWTP Gdańsk "Wschód'', Qav.=82x103 m3/d) with increasing, from 1 to 5 % (vol.), quantity of landfill leachate (collected from Gdańsk landfill ''Szadółki")....
-
Behavior of lipids in biological wastewater treatment plant processes
PublicationLipidy (oleje, smary, tłuszcze oraz długołańcuchowe kwasy tłuszczowe) są istotnym składnikiem ścieków. Ich ilość np. w ściekach komunalnych stanowi około 30-40% ogólnej wartości ChZT. Przemiany lipidów w procesach biologicznego oczyszczania są obiektem wielu badań, mimo to nie są do końca poznane i zrozumiane. W pracy przedstawiono przegląd literatury dotyczący przemian lipidów w trakcie tlenowego i beztlenowego oczyszczania ścieków...
-
Analysis of energy consumption at the Rzeszów Wastewater Treatment Plant
Publication -
Environmental risk assessment of Polish wastewater treatment plant activity
PublicationWastewater treatment plants (WWTPs) play an extremely important role in shaping modern society's environmental wellbeing and awareness, however only well operated and supervised systems can be considered as environmentally sustainable. For this reason, an attempt was undertaken to assess the environmental burden posed by WWTPs in major Polish cities by collecting water samples prior to and just after wastewater release points....
-
Spatial distribution of pharmaceuticals in conventional wastewater treatment plant with Sludge Treatment Reed Beds technology
PublicationPharmaceutical residues are an emerging environmental problem. It is strongly confirmed that pharmaceuticals are present in soils and environmental waters (surface, marine and even groundwater), and that wastewater treatment plant (WWTP) effluents are the main source of pharmaceuticals in the watershed. The aim of this studywas to recognize the spatial distribution and seasonal changes of selected pharmaceuticals in conventional WWTP...
-
Diversity of fecal coliforms and their antimicrobial resistance patterns in wastewater treatment model plant.
PublicationThe occurrence of resistance patterns among wastewater fecal coliforms was determined in the study. Susceptibility of the isolates was tested against 19 antimicrobial agents: aminoglycosides, aztreonam, carbapenems, cephalosporines, b-lactam/b-lactamase inhibitors, penicillines, tetracycline, trimethoprim/sulfamethoxazole, and fluoroquinolones. Additionally the removal of resistant isolates was evaluated in the laboratory-scale...
-
Application of subsurface vertical flow constructed wetlands to reject water treatment in dairy wastewater treatment plant
PublicationThe paper presents the effects of applying subsurface vertical flow constructed wetlands (SS VF) for the treatment of reject water generated in the process of aerobic sewage sludge stabilization in the biggest dairy wastewater treatment plant (WWTP) in Poland. Two SS VF beds were built: bed (A) with 0.65 m depth and bed (B) with 1.0 m depth, planted with reeds. Beds were fed with reject water with hydraulic load of 0.1 m d-1 in...
-
Respiration rate estimation using non-linear observers in application to wastewater treatment plant
PublicationA problem of respiration rate estimation using two new non-linear observers for a wastewater treatment plant is addressed in this paper. In particular, a non-linear adaptive Luenberger-like observer and a super twisting sliding mode observer have been derived to produce stable and bounded estimates of the respiration rate. During the synthesis of the particular observer, an appropriate mathematical utility model was used. The observability...
-
Task Scheduling – Review of Algorithms and Analysis of Potential Use in a Biological Wastewater Treatment Plant
PublicationThe idea of task scheduling is to increase the efficiency of a system by minimising wasted time, evenly loading machines, or maximising the throughput of machines. Moreover, the use of appropriate scheduling algorithms often leads to a reduction in the energy costs of the process. Task scheduling problems are found in a variety of industrial areas, and their scale changes significantly depending on the problem. This review shows...
-
Odour nuisance assessment of the food industry wastewater treatment plant
Publication -
Antimicrobial resistance of fecal indicators in municipal wastewater treatment plant
Publication -
Characteristics of odors emitted from municipal wastewater treatment plant and methods for their identification and deodorization techniques
PublicationOdors emitted from municipal wastewater treatment plants belong to a group of pollutants, which is the main cause of people complaining about atmospheric air quality. The limitation of emissions of unpleasant odors generated by wastewater treatment plants by using appropriate deodorization methods is omitted on numerous occasions. This can have a negative inflence on public trust and the quality of atmospheric air. The article...
-
Two-Step Model Based Adaptive Controller for Dissolved Oxygen Control in Sequencing Wastewater Batch Reactor
PublicationDissolved Oxygen (DO) concentration is a crucial parameter for efficient operation of biological processes taking place in the activated sludge Wastewater Treatment Plant (WWTP). High-quality DO control is difficult to achieve because of complex nonlinear behavior of the plant and substantial influent disturbances. A method to improve the Direct Model Reference Adaptive Control (DMRAC) technology in application to DO tracking for...
-
Chlorinated solvents in a petrochemical wastewater treatment plant: Anassessment of their removal using self-organising maps
PublicationThe self-organising map approach was used to assess the efficiency of chlorinated solvent removal frompetrochemical wastewater in a refinery wastewater treatment plant. Chlorinated solvents and inorganicanions (11 variables) were determined in 72 wastewater samples, collected from three different purificationstreams. The classification of variables identified technical solvents, brine from oil desalting andrunoff sulphates as pollution...
-
Analysis the Parameters of the Adaptive Controller for Quality Control of Dissolved Oxygen Concentration
PublicationThe wastewater treatment plant can be considered a dynamic large scale complex system, in which the most important control parameter is the dissolved oxygen concentration in the aerobic zone. The air is supplied to this zone by the aeration system. In the paper, both the sequencing batch reactor and the aeration system are modelled and used as plant of control performed by the cascade nonlinear adaptive control system extended...
-
Aeration Process in Bioreactors as the Main Energy Consumer in a Wastewater Treatment Plant. Review of Solutions and Methods of Process Optimization
PublicationDue to the key role of the biological decomposition process of organic compounds in wastewater treatment, a very important thing is appropriate aeration of activated sludge, because microorganisms have to be supplied with an appropriate amount of oxygen. Aeration is one of the most energy-consuming processes in the conventional activated sludge systems of wastewater treatment technology (may consume from 50% to 90% of electricity...
-
Differences between selected volatile aromatic compound concentrations in sludge samples in various steps of wastewater treatment plant operations
PublicationSewage sludge, one of the main wastes generated during wastewater treatment, constitutes an important source of emissions of volatile chemical compounds such as volatile aromatic compounds These substances may undergo various changes as a result of operations and unit processes, which affects their concentrations in sewage sludge. An important factor determining the potential hazardousness of volatile organic compounds is the quality...
-
Assessment of the Effects of Wastewater Treatment Plant Modernization by Means of the Field Olfactometry Method
Publication -
Diversity of fecal coliforms and their antimicrobial resistance patterns in wastewater treatment model plant
Publication -
The Effects of Wastewater Treatment Plant Failure on the Gulf of Gdansk (Southern Baltic Sea)
Publication -
The Problem of Wastewater in Shale Gas Exploitation The Influence of Fracturing Flowback Water on Activated Sludge at a Wastewater Treatment Plant
Publication -
A new approach to designing control of dissolved oxygen and aeration system in sequencing batch reactor by applied backstepping control algorithm
PublicationThe Wastewater Treatment Plant (WWTP) is a very complex system, due to its nonlinearity, time-variance, and multiple time scales in its dynamics among others. The most important control parameter in a WWTP is the Dissolved Oxygen (DO) concentration. The tracking problem of the DO concentration is one of the most fundamental issues in biological wastewater treatment. Proper DO concentration control is necessary to achieve adequate...
-
Improving SBR Performance Alongside with Cost Reduction through Optimizing Biological Processes and Dissolved Oxygen Concentration Trajectory
PublicationAuthors of this paper take under investigation the optimization of biological processes during the wastewater treatment in sequencing batch reactor (SBR) plant. A designed optimizing supervisory controller generates the dissolved oxygen (DO) trajectory for the lower level parts of the hierarchical control system. Proper adjustment of this element has an essential impact on the efficiency of the wastewater treatment process as well...
-
Nitrogen speciation in wastewater treatment plant influents and effluents - the US and Polish case studies
PublicationW pracy przedstawiono wyniki pomiarów różnych frakcji azotu w dopływachi odpływach z trzech konwencjonalnych oczyszczalni ścieków w stanie Illinois (USA) i czterech wysokoefektywnych oczyszczalni w północnej Polsce. Azot organiczny rozpuszczony był dominującą frakcją (56-95%) azotu ogólnego w odpływach z oczyszczalni amerykańskich, podczas gdy w odpływach z oczyszczalni polskich stanowił mniej istotną frakcję (19-62%). W jednym...