Filters
total: 455
Search results for: THERMAL CAMERA
-
Style Transfer for Detecting Vehicles with Thermal Camera
PublicationIn this work we focus on nighttime vehicle detection for intelligent traffic monitoring from the thermal camera. To train a Convolutional Neural Network (CNN) detector we create a stylized version of COCO (Common Objects in Context) dataset using Style Transfer technique that imitates images obtained from thermal cameras. This new dataset is further used for fine-tuning of the model and as a result detection accuracy on images...
-
Style Transfer for Detecting Vehicles with Thermal Camera
Publication -
Face detection in image sequences using a portable thermal camera
PublicationFace detection is often a first step in quantitative analysis of face images. It is an important research area for visible images and recently also for thermography. Due to technological developments thermal cameras may be embedded into wearable devices to provide remote healthcare. In this paper, we compared three algorithms for face detection in thermal images by testing execution time, accuracy, symmetry ratio and false-positives....
-
Evaluation of respiration rate and pattern using a portable thermal camera
PublicationThe goal of this paper was to analyze the accuracy of the proposed method for the evaluation of respiration rate and respiration rhythm patterns (e.g. inspiration slope) using the portable and mobile thermal camera module that could be a part of smart glasses. Parameters were analyzed for 12 volunteers in two experiments, when subjects speak and do not speak. The pressure, chest belt was used as a reference measurement method....
-
Estimation of respiration rate using an accelerometer and thermal camera in eGlasses
PublicationRespiration rate is a very important vital sign. Different methods of respiration rate measurement or estimation have been developed. However, especially interesting are those that enable remote and unobtrusive monitoring. In this study, we investigated the use of smart glasses for the estimation of respiration rate especially useful for indoors applications. Two methods were analyzed. The first one is based on measurements of...
-
Deterioration of masonry structure investigated by a thermal camera with a qualitative assessment of thermal image processing
PublicationThermal imaging is contemporary remote sensing measurement technique, which provides an image of the temperature distribution in the measured object. The method is widely used, due to its mobility as well as the non-destructive character of the measurement. Infrared thermography is especially relevant in the inspection of insulation, what is more, it is a suitable device for detecting thermal bridges and structural changes, which...
-
Intelligent thermal imaging camera with network interface
Publication -
ATTEMPTS OF THERMAL IMAGING CAMERA USAGE IN ESTIMATIONS OF THE CONVECTIVE HEAT LOSS FROM A VERTICAL PLATE
PublicationIn this paper a new method for determining heat transfer coefficients using a gradient method has been developed. To verify accuracy of the proposed method vertical isothermal heating plate with natural convection mechanism has been examined. This configuration was deliberately chosen, because of the fact that such case is historically the earliest and most thoroughly studied and its rich scientific documentation - the most reliable....
-
The use of thermal imaging camera to estimate velocity profiles based on temperature distribution in a free convection boundary layer
PublicationThis work describes an attempt to assess whether the temperature field from a thermal imaging camera can be converted into a velocity field with an accuracy sufficient for qualitative conducting or describing the phenomenon, i.e. when the Navier-Stokes, Fourier-Kirchhoff and continuity equations are mutually coupled. The consequence of this link between temperature fields and velocity is the possibility to formulate the hypothesis...
-
Method of reconstructing two-dimensional velocity fields on the basis of temperature field values measured with a thermal imaging camera
PublicationThis paper describes a novel numerical reconstruction procedure (NRP) of the velocity field during natural convective heat transfer from a two-sided, isothermal, heated vertical plate based only on the known temperature field obtained, e.g. with a thermal imaging camera. It has been demonstrated that with a knowledge of temperature distributions, the NRP enables the reconstruction of velocity fields by solving the Navier-Stokes...
-
Wykorzystanie kamery termowizyjnej nowej generacji do oceny wpływu sił ortodontycznych na dziąsło = The application of a new-generation thermal imaging camera for the assessment of hemodynamic changes in gingiva during orthodontic treatment
PublicationIntroduction. One ot the most interesting modern methods of assessing microcirculation is thermovisiual examination. Thermovision cameras are commonly used in general medicine. As the periodontium is one of the most vascularized tissues in the human body, the application of high-sensitivity thermovision cameras may allow tor noninvasive asses- sment and early detection ot pathological changes in the gingiva by giving a complete...
-
Detection of moving objects in images combined from video and thermal cameras
PublicationAn algorithm for detection of moving objects in video streams from the monitoring cameras is presented. A system composed of a standard video camera and a thermal camera, mounted in close proximity to each other, is used for object detection. First, a background subtraction is performed in both video streams separately, using the popular Gaussian Mixture Models method. For the next processing stage, the authors propose an algorithm...
-
Analysis of the parameters of respiration patterns extracted from thermal image sequences
PublicationRemote estimation of vital signs is an important and active area of research. The goal of this work was to analyze the feasibility of estimating respiration parameters from video sequences of faces recorded using a mobile thermal camera. Different estimators were analyzed and experimentally verified. It was demonstrated that the respiration rate, periodicity of respiration, and presence and length of apnea periods could be reliably...
-
Deep Features Class Activation Map for Thermal Face Detection and Tracking
PublicationRecently, capabilities of many computer vision tasks have significantly improved due to advances in Convolutional Neural Networks. In our research, we demonstrate that it can be also used for face detection from low resolution thermal images, acquired with a portable camera. The physical size of the camera used in our research allows for embedding it in a wearable device or indoor remote monitoring solution for elderly and disabled...
-
An Approach to the Detection of Bank Robbery Acts Employing Thermal Image Analysis
PublicationA novel approach to the detection of selected security-related events in bank monitoring systems is presented. Thermal camera images are used for the detection of people in difficult lighting conditions. Next, the algorithm analyses movement of objects detected in thermal or standard monitoring cameras using a method evolved from the motion history images algorithm. At the same time, thermal images are analyzed in order to detect...
-
Evaluation of Respiration Rate Using Thermal Imaging in Mobile Conditions
PublicationRespiratory rate is very important vital sign that should be measured and documented in many medical situations. The remote measurement of respiration rate can be especially valuable for medical screening purposes (e.g. severe acute respiratory syndrome (SARS), pandemic influenza, etc.). In this chapter we present a review of many different studies focused on the measurements and estimation of respiration rate using thermal imaging...
-
AITP - AI Thermal Pedestrians Dataset
Open Research DataAITP is a pedestrian detection dataset consisting of 9178 annotated thermal images. The training set contains 7801 images on which15448 pedestrians were labeled. The test set has 1377 images on which 2731 objects were marked. All images are in PNG file format (120x160) captured with FLIR Lepton Thermal Camera on the streets of Gdańsk, Poland. All pedestrians...
-
Influence of Additional Loads on Chosen Gait Parameters and Muscles Activity
PublicationThis paper is devoted to human motion analysis and comparison of chosen kinematics parameters during normal gait with and without additional load in a form of backpack. A stability in both cases were compared in both frontal and sagittal planes, by applying a video tracking system. Experimental tests performed on treadmill, passive markers, placed on volunteers bare skin were used. Additionally, an infra-red camera was employed...
-
Pose-Invariant Face Detection by Replacing Deep Neurons with Capsules for Thermal Imagery in Telemedicine
PublicationAbstract— The aim of this work was to examine the potential of thermal imaging as a cost-effective tool for convenient, non- intrusive remote monitoring of elderly people in different possible head orientations, without imposing specific behavior on users, e.g. looking toward the camera. Illumination and pose invariant head tracking is important for many medical applications as it can provide information, e.g. about vital signs, sensory...
-
FFT spectrum based matching algorithm for activedynamic thermography
PublicationIn Active Dynamic thermography (ADT) sequences of consecutive temperature distributions are analyzed. In biomedical applications of ADT, the problems of a patient's movements in front of a thermal camera should be eliminated before data analysis. Complete mechanical stabilization of the patients is impossible due to natural voluntary and involuntary moves caused by pulse breathing, etc. This paper presents a simple and efficient...
-
Measurement of the temperature change of PVCP tissue phantom illuminated by dermatological laser 1.series
Open Research DataApplication of laboratory set-up for characterization of thermal properties of optical tissue phantoms during laser irradiation is presented. The produced system utilizes a thermographic camera VIGOcam v50 and a dermatological laser system with a 975 nm diode laser module. The set-up was used to perform measurements of the temporal and spatial temperature...
-
Possibility of thermal imaging use in studies of natural convection heat transfer on the example of an isothermal vertical plate.
PublicationA new method of infrared (IR) camera use in convective heat transfer studies has been presented. Until now, IR cameras were utilized for temperature field visualizations of flat heated surfaces of solid objects only. Because liquids and gasses do not emit radiation in the infrared range of wave lengths, detection of temperature field in the air was conducted with the use of plastic mesh, which, after heating by hot air, emits infrared...
-
Measurement of the temporal and spatial temperature distribution on the surface of PVCP tissue phantom illuminated by laser.
Open Research DataApplication of laboratory set-up for characterisation of thermal properties of optical tissue phantoms during laser irradiation is presented. The produced system utilizes thermographic camera VIGOcam v50 and dermatological laser system with a 975 nm diode laser module. The set-up was used to perform measurements of the temporal and spatial temperature...
-
Multimodal Surveillance Based Personal Protection System
PublicationA novel, multimodal approach for automatic detection of abduction of a protected individual, employing dedicated personal protection device and a city monitoring system is proposed and overviewed. The solution is based on combining four modalities (signals coming from: Bluetooth, fixed and PTZ cameras, thermal camera, acoustic sensors). The Bluetooth signal is used continuously to monitor the protected person presence, and in case...
-
Quantitative study of free convective heat losses from thermodynamic partitions using Thermal Imaging
PublicationThe following paper presents a simple method of determining the presence, distribution and values of heat losses from external building walls as thermodynamic partitions using a Thermal Imaging Camera (TIC). According to Fourier's equation, the value of heat loss is proportional to the temperature gradient ∂t/∂y|y=0 in air in the y direction perpendicular to the heated surface. Unfortunately, air temperature cannot be measured...
-
Respiratory Rate Estimation Based on Detected Mask Area in Thermal Images
PublicationThe popularity of non-contact methods of measuring vital signs, particularly respiratory rate, has increased during the SARS-COV-2 pandemic. Breathing parameters can be estimated by analysis of temperature changes observed in thermal images of nostrils or mouth regions. However, wearing virus-protection face masks prevents direct detection of such face regions. In this work, we propose to use an automatic mask detection approach...
-
Synergistic Effects of Bitumen Plasticization and Microwave Treatment on Short-Term Devulcanization of Ground Tire Rubber
PublicationGround tire rubber (GTR) was mechano-chemically modified with road bitumen 160/220 and subsequently treated using a microwave radiation. The combined impact of bitumen 160/220 content and microwave treatment on short-term devulcanization of GTR was studied by thermal camera, wavelength dispersive X-ray fluorescence spectrometry (WD-XRF), static headspace, and gas chromatography-mass spectrometry (SHS-GC-MS), thermogravimetric analysis...
-
Verification of the method of reconstructing convective velocity fields on the basis of temperature fields in vertical, differential and equally heated, open and closed channels
PublicationThis paper describes a method of reconstructing velocity fields, i.e. a numerical reconstruction procedure (NRP) that involves the numerical processing of experimentally measured temperature distributions in free convection heat transfer. The NRP consists in solving only the continuity and Navier–Stokes equations with an additional source term. This term is proportional to a known temperature (e.g. from a thermal imaging camera)...
-
Thermographic images during testing measuring instrument boards
Open Research DataThe dataset presents thermografic images acquired during testing the prototype of measuring instrument for resistiometric corrosion monitoring. The testing was performed in the room temperature. VIGOcam v50 thermal imaging camera (VIGO System S.A., Ozarow Mazowiecki, Poland) was used for taking the pictures. These pictures were used as preliminary tests...
-
TiO2-C nanocomposite synthesized via facile surfactant-assisted method as a part of less energy-consuming LED-based photocatalytic system for environmental applications
PublicationA novel facile method was used to incorporate carbon into the titania structure. An alternative synthesis method of carbon-doped TiO2 has been proposed by using a widely used and cheap surfactant. During the process, cetyltrimethylammonium bromide plays a dual role, as a morphology modifier and as a carbon source. The presented approach allows obtained TiO2-C nanostructures to be anatase nanocrystals with carbon being deposited...
-
The Proposition of an Automated Honing Cell with Advanced Monitoring
PublicationHoning of holes allows for small shape deviation and a low value of a roughness profile parameter, e.g., Ra parameter. The honing process heats the workpiece and raises its temperature. The increase in temperature causes thermal deformations of the honed holes. The article proposes the construction of a honing cell, containing in addition to CNC honing machine: thermographic camera, sound intensity meter, and software for collecting...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 33 mA. Sample 51.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 33 mA.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 561 mA. Sample 71, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 561 mA. Sample 71, experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 560 mA. Sample 42, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 560 mA. Sample 42. Experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 336 mA. Sample 71.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 336 mA. Sample 71.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 54 mA. Sample 61.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 54 mA. Sample 61.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 306 mA. Sample 51, run #3.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 306 mA. Experiment run #3. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 306 mA. Sample 51, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 306 mA. Experiment run #1. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #8.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #8. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 560 mA. Sample 42, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 560 mA. Sample 42. Experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 400 mA. Sample 42.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 400 mA. Sample 42.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 162 mA. Sample 61.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 162 mA. Sample 61.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 51 mA. Sample 51.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 51 mA.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,1 V at 561 mA. Sample 71, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,1 V and discharged to 10 mV by constant current 561 mA. Sample 71, experiment run #2The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 480 mA. Sample 42.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 480 mA. Sample 42.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 561 mA. Sample 71.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 561 mA. Sample 71. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 102 mA. Sample 51, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 102 mA. Experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 27 mA. Sample 61.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 27 mA. Sample 61.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 306 mA. Sample 51, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 306 mA. Experiment run #2. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...