Filters
total: 40566
-
Catalog
- Publications 17077 available results
- Journals 289 available results
- Conferences 17 available results
- Publishing Houses 1 available results
- People 277 available results
- Inventions 24 available results
- Projects 71 available results
- Laboratories 4 available results
- Research Teams 2 available results
- Research Equipment 8 available results
- e-Learning Courses 499 available results
- Events 109 available results
- Open Research Data 22188 available results
displaying 1000 best results Help
Search results for: WATER DISTRIBUTION SYSTEM, ACID RAIN, CORROSION MONITORING, ONLINE, LINEAR POLARIZATION METHOD
-
DETERMINATION OF THE EFFECT OF ENVIRONMENTAL FACTORS ON THE CORROSION OF WATER DISTRIBUTION SYSTEM BASED ON ANALYSIS OF ON-LINE CORROSION MONITORING RESULTS
PublicationCorrosion of water distribution system is a significant issue causing problems with quality, safety and continuity of distribution. The changes of corrosion rates of the water distribution systems in Cracow made of carbon steel were investigated by analysis of online corrosion monitoring system results. Corrosion rates were determined using the linear polarization method. The impact of rain, temperatures, conductivity, dissolved...
-
Kazimierz Darowicki prof. dr hab. inż.
PeopleStudia wyższe ukończyłem w czerwcu 1981 roku po zdaniu egzaminu dyplomowego i obronie pracy magisterskiej. Opiekunem pracy magisterskiej był dr hab. inż. Tadeusz Szauer. W roku 1991, 27 listopada uzyskałem stopień naukowy broniąc pracę doktorską zatytułowaną „Symulacyjna i korelacyjna analiza widm immitancyjnych inhibitowanej reakcji elektrodowej”. Promotorem pracy był prof. dr hab. inż. Józef Kubicki (Wydział Chemiczny...
-
Complex Corrosion Monitoring System for Crude Distillation Unit in Form of Neutral Network
PublicationComplex and successful corrosion monitoring of refinery processes can significantly reduce material losses and failure risk. The developed corrosion monitoring system is based on online ultrasonic sensors, ER (electrical resistance) probes, gravimetric method and multipoint analytical analysis of chemical composition of the fluids. Additional online LPR (linear polarization resistance) sensors controlling corrosiveness of sour...
-
Cathodic Protection System of the Spiral Classifier at the KGHM Polska Miedź S.A. Ore Concentration Plant—Case Study of Commissioning and Control of Operating Parameters
PublicationThe project involved designing, constructing and commissioning a cathodic protection system for a selected spiral classifier operating at the KGHM Polska Miedź S.A. Ore Concentration Plant (O/ZWR). The authors developed a concept and assumptions regarding the corrosion protection of a large industrial device using a cathodic protection system with an external power source. Pre-project studies included conducting a trial polarization...
-
Investigation of corrosion behavior of 6060 and 6082 aluminum alloys under simulated acid rain conditions
PublicationInstantaneous impedance changes of 6060 and 6082 type aluminum alloys in pure water, and simulated acid rain poured into the pure water was investigated by dynamic electrochemical impedance spectroscopy (DEIS). In this way, the influence of aluminum content on the corrosion behavior of 6060 and 6082 type aluminum alloys immersed in simulated acid rain was determined. The corrosion rate of the alloy decreased with increasing Al...
-
Multi-sensor monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in utility water installations
PublicationThis paper presents an implementation of the monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in a utility water installation using an automated corrosion monitoring system. Due to the fact that the corrosion inhibitor was added to water intended for human consumption, it was necessary to build a multi-sensor monitoring system. In order to implement corrosion monitoring using a linear...
-
The protection and monitoring of a distribution piping network for potable water supply
PublicationPurpose – The purpose of this paper is to implement the corrosion protection method for steel pipes used in a municipal water-pipe network. Results of an inhibitor protection system installed on the system are presented. Inhibitor protection was required due to the high corrosivity of the water collected by a surface intake, which had resulted in a large number of failures and low water quality, due to the presence of corrosion...
-
Research on causes of corrosion in the municipal water supply system
PublicationThis paper presents results of failure analysis study to characterize the corrosion damage that occurred in the water supply system in Krakow. This analysis includes: electrochemical noise, linear polarization and resistometric measurements. Water aggressiveness of four water intakes was defined using Langelier and Ryznar indices. Results from this indices did not reveal the causes of considerable corrosion losses in water systems....
-
Critical analysis of laboratory measurements and monitoring system of water-pipe network corrosion-case study.
PublicationCase study of corrosion failure of urban water supply system caused by environmental factors was presented. Nowadays corrosion monitoring of water distribution systems is an object of major concern. There is possibility of application broad range of techniques like gravimetric and electrochemical. Both kinds of techniques can be applied in laboratory and field conditions. In many cases researches limit the case analysis to measurements...
-
Novel fast non-linear electrochemical impedance method for corrosion investigations
PublicationThe paper presents a novel approach to corrosion rate monitoring using non-linear electrochemical impedance spectroscopy. The authors propose a new variant of non-linear impedance measurement using amplitude-modulated multi-frequency ac perturbation signal. It allows shortening of measurement duration so it is possible to monitor corrosion rate of the systems experiencing rapid changes. In this way a limitation resulting from lack...
-
Robust Monitoring of Water Quality in Drinking Water Distribution System
PublicationThe paper develops a novel open loop set bounded observer for robust estimation of water quality in DWDS based on the advanced nonlinear quality dynamics model including disinfections by-products (DBPs). The observer utilises a cooperativeness of the quality dynamics model and is computationally efficient, hence applicable to on-line quality monitoring. The simulation results illustrate its good and sustainable performance.
-
A comprehensive evaluation of mimosa extract as a corrosion inhibitor on AA6060 alloy in acid rain solution: part I. Electrochemical AC methods
PublicationThe inhibition effect of mimosa extract on the corrosion of AA6060 aluminum alloy in acid rain solution was investigated by electrochemical impedance spectroscopy and dynamic electrochemical impedance spectroscopy (DEIS). All the studied electrochemical parameters showed good corrosion inhibitive characteristics with respect to the aluminum alloy in the tested solution. Inhibitor efficiency increased with the concentration and...
-
Online urban acoustic noise monitoring system
PublicationConcepts and implementation of the Online Urban Noise Monitoring System are presented. Principles of proposed solution used for dynamic acoustical maps creating are discussed. The architecture of the system and the data acquisition scheme are described. The concept of noise mapping, based on noise source model and propagation simulations, was developed and employed in the system. Dynamic estimation of noise source parameters utilized...
-
Measurement Automation Monitoring
Journals -
Monitoring of underdeck corrosion by using acoustic emission method
PublicationThis paper presents first short characteristics of underdeck corrosion process as well as a problem of its monitoring. Next is described an acoustic emission (AE) method elaborated by Department of Ship Technology , Quality Systems and Material Engineering, Gdańsk University of Technology in cooperation with partners of CORFAT project realized within 7th EU Frame Program . Further are presented short characteristics of the emission...
-
Application of an online judge & contester system in academic tuition
PublicationPraca zawiera opis systemu typu ''Online judge & contester'' o nazwie SPOJ, wykorzystywanego do zdalnej nauki programowania. Został on pomyślnie wdrożony w nauczaniu informatyki na Politechnice Gdańskiej. Omówiono zasadę działania i mechanizmy bezpieczeństwa systemu SPOJ. Przedstawiono wnioski z doświadczeń przy stosowaniu tego typu systemów w nauczaniu na etapie studiów 1. i 2. stopnia w ciągu ostatnich czterech lat.
-
Application of an online judge & contester system in academic tuition
PublicationPraca zawiera opis systemu typu ''Online judge & contester'' o nazwie SPOJ, wykorzystywanego do zdalnej nauki programowania. Został on pomyślnie wdrożony w nauczaniu informatyki na Politechnice Gdańskiej. Omówiono zasadę działania i mechanizmy bezpieczeństwa systemu SPOJ. Przedstawiono wnioski z doświadczeń przy stosowaniu tego typu systemów w nauczaniu na etapie studiów 1. i 2. stopnia w ciągu ostatnich czterech lat.
-
Corrosion monitoring as a factor increasing the safety of hydrotechnical infrastructure
PublicationWater distribution systems at KGHM S.A. are of great importance for the efficient production of copper and environmental protection. For failures leading to perforation and leakage, the corrosion processes are responsible. This paper aims to assess corrosion on the basis of the analysis of the exposure of the Hydrotechnical Plant pipelines. To this end, the system of transfer and deposition of post-flotation waste as well as the...
-
Corrosion monitoring by harmonic analysis in aqueous environments
PublicationThis paper presents tests concerning the rate of corrosion in non-alloy steel (type S235JR) in an aqueous environment, with an additive of sodium chloride by means of polarization resistance measurements and harmonic analysis. The tests have been carried out for steel samples exposed to the testing environment for six weeks, in order to obtain a constant rate of corrosion in the function of time. The measurements have aimed at...
-
Piotr Szczuko dr hab. inż.
PeoplePiotr Szczuko received his M.Sc. degree in 2002. His thesis was dedicated to examination of correlation phenomena between perception of sound and vision for surround sound and digital image. He finished Ph.D. studies in 2007 and one year later completed a dissertation "Application of Fuzzy Rules in Computer Character Animation" that received award of Prime Minister of Poland. His interests include: processing of audio and video, computer...
-
Container monitoring system
PublicationW pracy przedstawiono koncepcję systemu monitorowania kontenerów przewożonych drogą morską. Scharakteryzowano główne cechy oraz przedstawiono modułowo-warstwowy schemat funkcjonalny. Ponadto opisano założenia funkcjonalno-użytkowe dotyczące Inteligentnego Modułu Kontenerowego (SCM), będącego podstawowym elementem składowym systemu. Przedstawiono również główne zadania projektowe związane z realizacją projektu
-
An interval estimator for chlorine monitoring in drinking water distribution systems under uncertain system dynamics, inputs and chlorine concentration measurement errors
PublicationThe design of an interval observer for estimation of unmeasured state variables with application to drinking water distribution systems is described. In particular, the design process of such an observer is considered for estimation of the water quality described by the concentration of free chlorine. The interval observer is derived to produce the robust interval bounds on the estimated water quality state variables. The stability...
-
Simultaneous impedance and volumetric studies and additionally potentiodynamic polarization measurements of molasses as a carbon steel corrosion inhibitor in 1M hydrochloric acid solution
PublicationThe inhibition effect of molasses on the corrosion of low carbon steel in 1M hydrochloric acid solution was investigated by volumetric and electrochemical measurements. Potentiodynamic polarization and dynamic electrochemical impedance spectroscopy (DEIS) results were obtained and compared with to those, obtained with the hydrogen evolution technique. All results indicate that molasses functioned as a good inhibitor in 1M hydrochloric...
-
Rain Water: Atmospheric Deposition
PublicationWater is transferred from the atmosphere to the land surface mainly via various forms of atmospheric precipitation; however, the contribution of surface condensation/deposition (e.g., dew, hoar frost, occult precipitation) should not be neglected. Rainwater and liquid deposits (dew, hoar frost, rime) are components of the physical and geographical environment that are easily assimilated and transported. Thus, they are generally...
-
A measurement system for nonlinear surface spectroscopy with an atomic force microscope during corrosion process monitoring
PublicationIn addition to traditional imaging the surface, atomic force microscopy (AFM) enables wide variety of additional measurements. One of them is higher harmonic imaging. In tapping mode the nonlinear contact between tip and specimen results in higher frequency vibrations. More information available from the higher harmonics analysis proves to be helpful for more detailed imaging. Such visualization is espe-cially useful for heterogeneous...
-
Water
Journals -
An optimised placement of the hard quality sensors for a robust monitoring of the chlorine concentration in drinking water distribution systems
PublicationThe problem of an optimised placement of the hard quality sensors in drinking water distribution systemsunder several water demand scenarios for a robust monitoring of the chlorine concentration is formulatedin this paper. The optimality is understood as achieving a desired trade off between the sensors and theirmaintenance costs and the accuracy of estimation of the chlorine concentration. The contribution of thiswork is a comprehensive...
-
Multisine impedimetric monitoring with an in-depth distribution of relaxation times analysis of WE43 and AZ31 magnesium alloys corrosion
PublicationThis research aims to develop and utilize an impedance-based tool for monitoring non-stationary electrochemical processes, coupling the multisinusoidal perturbation signal approach and distribution of relaxation times (DRT) analysis for the first time. The approach was used to distinguish independent processes occurring at the surface of AZ31 and WE43 Mg alloys undergoing corrosion in Hank’s Balanced Salt Solution at 37 °C. We...
-
Quality Model for Integrated Security Monitoring and Control in Water Distribution Systems
PublicationThis article addresses the problem of drinking water distribution system (DWDS) security in the terms of water quality which in the era of terrorist threat is of high importance to the public. The contribution of this paper is the development of the so called security module to extend a multi-species water quality model. This gives an insight to the situation in DWDS not only under normal operational conditions but also in case...
-
Development Of Dynamic Method For Evaluation Of Corrosion Rate On The Example Of Organic Corrosion İnhibitor
PublicationMeasurements of the corrosion rate belong to the most important aspects of materials science. In order to reduce material loss corrosion inhibitors are used. However selection of proper inhibitor should be based on evaluation of its mechanism and effective concentrations. Mechanism of inhibition usually has dynamic character so physicochemical parameters are changing in time. Most of actually used methods...
-
Polarization sensitive optical coherence tomography system
PublicationW pracy pokazano system OCT czuły na stan polaryzacji do pomiaru właściwości dwójłomnych wybranych ośrodków rozpraszających światło. W systemie zastosowano detekcję zrównoważoną. Pokazano wstępne wyniki pomiarowe.
-
Data-driven models for fault detection using kernel pca:a water distribution system case study
PublicationKernel Principal Component Analysis (KPCA), an example of machine learning, can be considered a non-linear extension of the PCA method. While various applications of KPCA are known, this paper explores the possibility to use it for building a data-driven model of a non-linear system-the water distribution system of the Chojnice town (Poland). This model is utilised for fault detection with the emphasis on water leakage detection....
-
Optimised Robust Placement of Hard Quality Sensors for Robust Monitoring of Quality in Drinking Water Distribution Systems
PublicationA problem of optimised robust placement of the hard quality sensors in Drinking Water Distribution Systems under several water demand scenarios for robust quality monitoring is formulated. Numerical algorithms to solve the problem are derived. The optimality is meant as achieving at the same time a desired trade off between the sensor capital and maintenance costs and resulting robust estimation accuracy of the monitoring algorithm...
-
Instantaneous impedance monitoring of AA 7075 aluminum alloy corrosion in borate buffer with admixed chloride ions
PublicationThe study presents a research capabilities of Dynamic Electrochemical Impedance Spectroscopy (DEIS) as a tool used for instantaneous on-line monitoring of corrosion processes on the example of AA 7075 aluminum alloy. A borate buffer with admixed chloride ions in a quantity ranging from 0.05 to 25 mM was used to represent different types of corrosion attack. The surface of samples specimens was evaluated before and after the tests...
-
Monitoring of Chlorine Concentration in Drinking Water Distribution Systems Using an Interval Estimator
PublicationThis paper describes the design of an interval observer for the estimation of unmeasured quality state variables in drinking water distribution systems. The estimator utilizes a set bounded model of uncertainty to produce robust interval bounds on the estimated state variables of the water quality. The bounds are generated by solving two differential equations. Hence the numerical efficiency is sufficient for on-line monitoring...
-
Wet H2S corrosion and degradation of pipeline in amine regeneration system
PublicationThe paper presents the results of NDT examinations, metallographic tests and risk assessment of degradation related to corrosion of amine regeneration unit in a desulphurisation system. Intensive corrosion resulting from acid gases environment upon water condensation causes perforation of the pipeline. Detailed analysis reveals cracking related to the mechanism of wet H2S. Hydrogen penetration, resulting from the wet H2S process,...
-
Influence of water salinity on corrosion risk - the case of the southern Baltic Sea coast.
PublicationWater corrosivity in Gdansk Bay, Poland, the southern part of the Baltic Sea, was investigated. The analysed region is heavily industrialized, and the coastline is very diverse. Twenty-seven test points along the coastline were selected. Water parameters such as salinity, total dissolved solids content, resistivity, conductivity, oxygenation, pH and corrosion rate were determined. The results of the investigation are presented....
-
Measurement system for nonlinear surface spectroscopy by atomic force microscopy for corrosion processes monitoring
PublicationIn addition to traditional imaging the surface, atomic force microscopy (AFM) enables wide variety of additional measurements. One of them is higher harmonic imaging. In tapping mode the nonlinear contact between tip and specimen results in higher frequency vibrations. More information available from the higher harmonics analysis proves to be helpful for more detailed imaging. Such visualization is especially useful for heterogeneous...
-
Optimised Allocation of Hard Quality Sensors for Robust Monitoring of Quality in Drinking Water Distribution Systems
PublicationA problem of optimised placement of the hard quality sensors in Drinking Water Distribution Systems for robust quality monitoring is formulated. Two numerical algorithms to solve the problem are derived. The optimality is meant as achieving a desired trade off between the sensor capital and maintenance costs and resulting robust estimation accuracy of the monitoring algorithm. The robust estimation algorithm recently developed...
-
The corrosion studies of 3,4,5-trihydroxybenzoic acid as an effective corrosion inhibitor of low alloy steel
Open Research DataThe dataset contains the electrochemical studies evaluating if gallic acid is a corrosion inhibitor for low alloy steel. Three measurements were carried out each case; corrosion potential (label ecorr), electrochemical impedance spectroscopy (label eis) and cyclic polarization (label cp). The measurements were carried out in sodium chloride, acidified...
-
Kernel PCA in Application to Leakage Detection in Drinking Water Distribution System
PublicationMonitoring plays an important role in advanced control of complex dynamic systems. Precise information about system's behaviour, including faults detection, enables efficient control. Proposed method- Kernel Principal Component Analysis (KPCA), a representative of machine learning, skilfully takes full advantage of the well known PCA method and extends its application to nonlinear case. The paper explains the general idea of KPCA...
-
Corrosion hazards and inhibitor protection in the seawater injection system on the Baltic sea rig
PublicationOil extraction efficiency in LOTOS Petrobaltic Company is increased by means of injection of seawater into an oilfield aquifer, which is implemented on the Baltic Beta rig, operating on the Baltic Sea. Operational experience has shown a significant degree of corrosion aggressiveness in the injected water, which necessitates frequent repairs of the seawater injection installation. Evaluation of the corrosion phenomena is crucial...
-
Multimedia noise monitoring system
PublicationW artykule przedstawiono Multimedialny System Monitorowania Hałasu. Projekt jest sieciocentrycznym systemem dedykowanym monitorowaniu zagrożeń hałasem. Jego nadrzędnym celem jest zwiększenie skuteczności w zakresie profilaktyki chorób słuchu. Umożliwia pobieranie, gromadzenie, analizę i wizualizację danych dotyczących hałasu, pobieranych ze zdalnych urządzeń pomiarowych oraz elektronicznych ankiet dostępnych przez Internet. Ponadto...
-
Implementation of integrated control In drinking water distribution systems - IT system proposal
PublicationImplementation of integrated control algorithms requires suitable hardware and software platforms. Proposed solution must allow realizing control and monitoring tasks, while ensuring high reliability and security of processed data. Additionally, the software and hardware solutions must be immune to outside influence. This paper presents an approach to implementation of control systems in drinking water distribution system. Presented...
-
Interval estimator for chlorine monitoring in drinking water distribution systems under uncertain system dynamics, inputs and state measurement errors
PublicationThe design of interval observer for estimation of unmeasured state variables for application to drinking water distribution systems is described in this paper. In particular, it considers the design of such observer for estimation of water quality described by free chlorine concentration. An interval observer is derived to produce robust interval bounds on the estimated water quality state variables. The stability and robustness...
-
Ellipsometric monitoring during the polarization studies of Mg corrosion in alkaline environment
Open Research DataThe dataset contains the ellipsometric results from the Mg polarization studies aiming at understanding the Mg(OH)2 passive layer formation mechanism and conditions. The single-wavelength ellipsometer ELX-02C from Dr Riss GmbH was utilized, operating He-Ne laser at 632.8 nm. The polarization conditions for the experiment are depicted in the related...
-
Evaluation of citric acid corrosion inhibition efficiency and passivation kinetics for aluminium alloys in alkaline media by means of dynamic impedance monitoring
PublicationA novel approach is proposed for constructing the adsorption isotherm in corrosion studies, based on a well-known interaction between citric acid and aluminium in alkaline electrolytes. Our approach utilizes the instantaneous impedance measurements via Dynamic Electrochemical Impedance Spectroscopy in galvanostatic mode (g-DEIS). Unlike other common tools, g-DEIS delivers exact information about the concentration required for full...
-
Corrosion Monitoring in Petroleum Installations—Practical Analysis of the Methods
PublicationThis paper presents the most typical corrosion mechanisms occurring in the petroleum industry. The methods of corrosion monitoring are described for particular corrosion mechanisms. The field and scope of the application of given corrosion-monitoring methods are provided in detail. The main advantages and disadvantages of particular methods are highlighted. Measurement difficulties and obstacles are identified and widely discussed...
-
Identification of the Contamination Source Location in the Drinking Water Distribution System Based on the Neural Network Classifier
PublicationThe contamination ingression to the Water Distribution System (WDS) may have a major impact on the drinking water consumers health. In the case of the WDS contamination the data from the water quality sensors may be efficiently used for the appropriate disaster management. In this paper the methodology based on the Learning Vector Quantization (LVQ) neural network classifier for the identification of the contamination source location...
-
Simplified method of water cooled exhaust system design.
PublicationThe water cooled exhaust systems are not often used onboard ships. Prime goal is to lower temperature of exhaust gas from main propulsion and auxiliary engines to the defined limit. The design of such systems require detailed analysis of propulsion system operational parameters to meet designer expectations. The paper outlines the cooled exhaust system design problems in specific application. The simplified method of evaluation...