Filters
total: 1393
filtered: 1217
-
Catalog
Chosen catalog filters
displaying 1000 best results Help
Search results for: INDIRECT CALIBRATION
-
Peculiarities of measurement uncertainty evaluation at calibrating a ring gauge
PublicationExample S13 from EA-4/02 M:2013 “Calibration of a ring gauge with a nominal diameter of 90 mm” is analyzed. The report uses the kurtosis method and the law of propagation of expanded uncertainty developed by the authors to the expanded uncertainty evaluation. It is shown that the introduction of a coaxiality correction for the ring gauge and the measuring axis of the comparator leads to the need to estimate its standard measurement...
-
Static renewal and continuous-flow calibration of two types of passive samplers for the monitoring of pharmaceuticals in wastewater
Publication -
Monitoring of n-butanol vapors biofiltration process using an electronic nose combined with calibration models
PublicationMalodours, by definition, are generally unpleasant, nuisance smells that are a mixture of volatile chemical compounds which can be perceptible even at low concentrations. Due to the more frequent occurrence of odour nuisance associated with the odour sensations, and thus the need to remove them from the air, deodorization techniques are commonly used. Biofiltration is one of the methods of reducing odorants in the air stream. In...
-
Efficient RSS-Based DoA Estimation for ESPAR Antennas Using Multiplane SDR Calibration Approach
PublicationIn this paper, we have introduced a new method to improve overall efficiency of direction-of-arrival (DoA) estimation scheme relying on received signal strength (RSS) values measured at the output port of electronically steerable parasitic array radiator (ESPAR) antenna. The proposed approach uses software-defined radio (SDR) setup and power pattern cross-correlation (PPCC) estimator involving multiple calibration planes. By placing...
-
Multianalyte Calibration Methods for Potentiometric Integrated Sensors System for Determination of Ions Concentration in a Body Fluids
PublicationIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in a small sample volume. One of the key problems related to the preparation of integrated sensors systems (ISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim of the research...
-
Calibration of precipitation estimation algorithm with particular emphasis on the Pomeranian region using high performance computing
PublicationFast and accurate precipitation estimation is an important element of remote atmosphere monitoring, as it allows, for example, to correct short-term weather forecasts and the prediction of several types of meteorological threats. The paper presents methodology for calibrating precipitation estimation algorithm based on MSG SEVIRI sensor data, and Optimal Cloud Analysis product available via EumetCast transmission. Calibration is...
-
Application of the chromatographic retention index system for theestimation of the calibration constants of permeation passivesamplers with polydimethylsiloxane membranes
PublicationW pracy przedstawiono wyniki badań z zastosowaniem pasywnych dozymetrów typu permeacyjnego, wyposażonych w membrany wykonane z PDMS. Badania dotyczyły oszacowania wartości stałych kalibracyjnych dozymetrów przy wykorzystaniu systemu indeksów retencji, wyznaczanych chromatograficznie, w warunkach liniowego narostu temperatury pracy kolumny (LTPRI). Znaleziono korelację pomiędzy wartościami stałych kalibracyjnych próbników typu pasywnego,...
-
T1 RELAXATION TIME CALLIBRATION IN MAGNETIC RESONANCE IMAGING USING NANODIAMOND PHANTOMS
PublicationMRI is increasingly used in radiation treatment planning because of the excellent soft tissue contrast in the obtained images. It allows more precise definition of the boundaries between healthy tissues and those affected by cancerous lesions. To obtain good image quality, the difference in signal between two types of tissue must be significant despite the noise so it must be properly calibrated. This calibration includes...
-
Indirect Methods of Fish Target Strenght Estimation in Absolute and Logarithmic Domain
PublicationW artykule przedstawiono wyniki estymacji zasobów ryb realizowane w dziedzinie absolutnej (jako estymacja rozproszenia wstecznego) oraz w dziedzinie logarytmicznej (estymacja siły celu).
-
Application of the chromatographic retention index system for the estimation of the calibration constants of permeation passive samplers with polydimethylsiloxane membranes
PublicationThe paper presents the results of research on the calibration of permeation passive samplers equipped with polydimethylsiloxane (PDMS) membranes using the physico-chemical properties of the analytes. Strong correlations were found between the calibration constants of the samplers and the linear temperature-programmed retention indices of the analytes determined on columns coated with pure PDMS (r2 = 0.914). These correlations...
-
Utilization of thermal decomposition of immobilized compounds for the generation of gaseous standard mixtures used in the calibration of gas analysers
Publication -
Physical modeling in sands in a wide range of stress level: Application to the calibration of CPTU i DMT tests.
PublicationPraca dotyczy badań modelowych w gruntach niespoistych ze szczególnym uwzględnieniem wpływu wysokiego poziomu naprężenia na zachowanie się podłoża gruntowego. Praca składa się z siedmiu rozdziałów. W pierwszym z nich opisano zachowanie się piasku w szerokim zakresie naprężeń z uwzględnieniem ściśliwości, kruszenia się ziaren, nieliniowości obwiedni zniszczenia oraz nieliniowości modułu odkształcenia związanych z poziomem naprężenia...
-
Efficient Calibration of Cost-Efficient Particulate Matter Sensors Using Machine Learning and Time-Series Alignment
PublicationAtmospheric particulate matter (PM) poses a significant threat to human health, infiltrating the lungs and brain and leading to severe issues such as heart and lung diseases, cancer, and premature death. The main sources of PM pollution are vehicular and industrial emissions, construction and agricultural activities, and natural phenomena such as wildfires. Research underscores the absence of a safe threshold for particulate exposure,...
-
Cost-Efficient Measurement Platform and Machine-Learning-Based Sensor Calibration for Precise NO2 Pollution Monitoring
PublicationAir quality significantly impacts human health, the environment, and the economy. Precise real-time monitoring of air pollution is crucial for managing associated risks and developing appropriate short- and long-term measures. Nitrogen dioxide (NO2) stands as a common pollutant, with elevated levels posing risks to the human respiratory tract, exacerbating respiratory infections and asthma, and potentially leading to chronic lung...
-
Filter-Hilbert Method for Automatic Correction of Non-Anechoic Antenna Measurements with Embedded Self-Calibration Mechanism
PublicationOne of the most important steps in the process of antenna development involves measurements of its prototype. Far-field performance of radiators is normally characterized in strictly controlled environments such as anechoic chambers which can ensure certification-grade accuracy. Unfortunately, they are also characterized by high construction costs which might not be justified for low-budget research and/or teaching-related activities....
-
A Method of Fast and Simultaneous Calibration of Many Mobile FMCW Radars Operating in a Network Anti-Drone System
PublicationA market for small drones is developing very fast. They are used for leisure activities and exploited in commercial applications. However, there is a growing concern for accidental or even criminal misuses of these platforms. Dangerous incidents with drones are appearing more often, and have caused many institutions to start thinking about anti-drone solutions. There are many cases when building stationary systems seems to be aimless...
-
Nanodiamond phantoms mimicking human liver: perspective to calibration of T1 relaxation time in magnetic resonance imaging
PublicationPhantoms of biological tissues are materials that mimic the properties of real tissues. This study shows the development of phantoms with nanodiamond particles for calibration of T1 relaxation time in magnetic resonance imaging. Magnetic resonance imaging (MRI) is a commonly used and non-invasive method of detecting pathological changes inside the human body. Nevertheless, before a new MRI device is approved for use, it is necessary...
-
Reply to Comment on ‘Nanodiamond incorporated human liver mimicking phantoms: prospective calibration medium of magnetic resonance imaging’
PublicationDependence of the spin–lattice (T1) relaxation times on the nanodiamond concentration in human liver phantoms is discussed. Factors affecting stability and and reproducibility of these phantoms are presented. The need for comparative measurements on multiple MRI scanners for better understanding of potential variations in the obtained imaging data is emphasised.
-
Field Calibration of Low-Cost Particulate Matter Sensors Using Artificial Neural Networks and Affine Response Correction
PublicationDue to detrimental effects of atmospheric particulate matter (PM), its accurate monitoring is of paramount importance, especially in densely populated urban areas. However, precise measurement of PM levels requires expensive and sophisticated equipment. Although low-cost alternatives are gaining popularity, their reliability is questionable, attributed to sensitivity to environmental conditions, inherent instability, and manufacturing...
-
Fast Calibration-Free Single-Anchor Indoor Localization Based on Limited Number of ESPAR Antenna Radiation Patterns
Publication— In this article, we investigate how the calibrationfree single-anchor indoor localization algorithm developed for base stations equipped with electronically steerable parasitic array radiator (ESPAR) antennas can further be improved. By reducing the total number of ESPAR antenna radiation patterns used in localization process, one can significantly reduce the time needed for an object localization. Performed localization measurements...
-
On Memory-Based Precise Calibration of Cost-Efficient NO2 Sensor Using Artificial Intelligence and Global Response Correction
PublicationNitrogen dioxide (NO2) is a prevalent air pollutant, particularly abundant in densely populated urban regions. Given its harmful impact on health and the environment, precise real-time monitoring of NO2 concentration is crucial, particularly for devising and executing risk mitigation strategies. However, achieving precise measurements of NO2 is challenging due to the need for expensive and cumbersome equipment. This has spurred...
-
Accurate PPCC-Based DoA Estimation Using Multiple Calibration Planes for WSN Nodes Equipped with ESPAR Antennas
PublicationIn this paper, we have introduced a new direction-of-arrival (DoA) estimation method, which relies on received signal strength (RSS) values measured at the output port of electronically steerable parasitic array radiator (ESPAR) antenna and uses the power pattern cross-correlation (PPCC) estimator. In the method, we have successfully incorporated measurements of ESPAR antenna's radiation patterns performed at multiple calibration...
-
Kalibracja przyrządów analitycznych, wykorzystanie gazowych mieszanin wzorcowych. Calibration of analitycal instruments, utilization of gaseous standard mixtures
PublicationScharakteryzowano techniki kalibracji jakościowej i ilościowej. Przedstawiono również rolę gazowych mieszanin wzorcowych w procesie kalibracji przyrządów analitycznych oraz wpływ wyboru techniki sporządzania gazowych standardów na spójność pomiarową.
-
Jubileusz Profesor Janiny Bartoszewskiej [Anniversary celebration for Professor Janina Bartoszewska]
Publication -
Stable indirect adaptive control based on discrete-time T-S fuzzy model
PublicationThis paper presents an indirect adaptive fuzzy control scheme for uncertain nonlinear asymptotically stable plants.A discrete-time T-S fuzzy input-output model is employed to approximate the unknown plant dynamics. The T-S fuzzy model is fed with its own states, which are indeed its past outputs, rather than the measurements from the plants. Entirely based on this model, a feedback linearization control law is designed by using...
-
Stable indirect adaptive control based on discrete-time T-S fuzzy model
PublicationThis paper presents an indirect adaptive fuzzy control scheme for uncertain nonlinear asymptotically stable plants.A discrete-time T-S fuzzy input-output model is employed to approximate the unknown plant dynamics. The T-S fuzzy model is fed with its own states, which are indeed its past outputs, rather than the measurements from the plants. Entirely based on this model, a feedback linearization control law is designed by using...
-
Indirect adaptive controller based on a self-structuring fuzzy system for nonlinear modeling and control
PublicationIn this paper, a unified nonlinear modeling and control scheme is presented. A self-structuring Takagi-Sugeno (T-S) fuzzymodel is used to approximate the unknown nonlinear plant based on I/O data collected on-line. Both the structure and theparameters of the T-S fuzzy model are updated by an on-line clustering method and a recursive least squares estimation(RLSE) algorithm. The rules of the fuzzy model can be added, replaced or...
-
THE USE OF FEM FOR DETERMINATION OF RESONANT FREQUENCIES OF CIRCULAR SAW BLADES WITH INDIRECT TEETH IN GULLETS
PublicationUnderstanding the dynamical properties of the circular saw blade is necessary, since, there is a really need for a stable work at working rotational speeds, which are determined by frequencies at which the circular saw blade tends to vibrate. It was observed that the resonant frequency depend on the circular saw blade shape, a collar diameter and on saw’s teeth shape. In the presented work an attention was paid to the effect of...
-
On Rapid Design Optimization and Calibration of Microwave Sensors Based on Equivalent Complementary Resonators for High Sensitivity and Low Fabrication Tolerance
PublicationThis paper presents the design, optimization, and calibration of multivariable resonators for mi-crowave dielectric sensors. An optimization technique for circular complementary split ring reso-nator (CC-SRR) and square complementary split ring resonator (SC-SRR) is presented to achieve the required transmission response in a precise manner. The optimized resonators are manufac-tured using a standard photolithographic technique...
-
Time-Gating method with automatic calibration for accurate measurements of electrically small antenna radiation patterns in Non-Anechoic environments
PublicationNon-anechoic sites represent a cheap alternative to measurements of antennas in dedicated facilities. However, due to a high noise—from the external EM signal sources and multipath interferences—the quality of radiation patterns obtained in non-anechoic conditions is poor. The characteristics can be corrected using a time-gating method (TGM), which involves filtering of the noise based on temporal analysis of the measured signals....
-
The current amplifier in low frequency noise measurements; Absolute calibration and rigorous 1/f noise extraction for MOSFET´s
PublicationPrzedstawiono budowę wzmacniacza prądowego i sposób obliczania szumów wyjściowych przy dołączonym do wejścia rezystorze wzorcowym. Przedstawiono wyniki eksperymentów potwierdzających prawidłowość przyjętego sposobu postępowania. Zaproponowano metodę wyznaczania składowej 1/f szumów drenu tranzystora MOSFET.
-
The Indirect Relationship Between Spiritual Experiences and Subjective Wellbeing Through Hope? A Sample of Chilean Students
Publication -
CALIBRATION OF LOW ENERGY X-RAY EXPERIMENTAL SETUP WITH STRONGLY FILTERED BEAM USING DATA FROM A SEMICONDUCTOR AND A THERMOLUMINESCENT DETECTORS
Publication -
Utilization of standards generated in the process of thermal decomposition chemically modified silica gel for a single point calibration of a GC/FID system
Publication -
Thermal decomposition of surface compounds for the generation of small quantities of acetaldehyde. Calibration of a thermal desorption gas chromatography flame ionization detection.
PublicationW pracy opisano sposób wytwarzania niewielkich ilości acetaldehydu w procesie termicznego rozkładu związku powierzchniowego uzyskanego w wyniku chemicznej modyfikacji żelu krzemionkowego.Proces rozkładu prowadzony jest w temperaturze 130-190 stopni Celsjusza.Przedstawiono również sposób syntezy prowadzący do uzyskania odpowiedniego związku powierzchniowego.
-
Accounting for the distributions of input quantities in the procedure for the measurement uncertainty evaluation when calibrating the goniometer
PublicationThe discords concerning the measurement uncertainty evaluation in the Guide to the Expressing of Uncertainty in Measurement (GUM) and its Supplement 1 are considered. To overcome these discords, the authors of the paper propose to use the kurtosis method and the law of the propagation of the expanded uncertainty. Using the example of the goniometer calibration, the features of accounting for the distribution laws of input quantities...
-
Machine-learning-based precise cost-efficient NO2 sensor calibration by means of time series matching and global data pre-processing
PublicationAir pollution remains a considerable contemporary challenge affecting life quality, the environment, and economic well-being. It encompasses an array of pollutants—gases, particulate matter, biological molecules—emanating from sources such as vehicle emissions, industrial activities, agriculture, and natural occurrences. Nitrogen dioxide (NO2), a harmful gas, is particularly abundant in densely populated urban areas. Given its...
-
Statistical Data Pre-Processing and Time Series Incorporation for High-Efficacy Calibration of Low-Cost NO2 Sensor Using Machine Learning
PublicationAir pollution stands as a significant modern-day challenge impacting life quality, the environment, and the economy. It comprises various pollutants like gases, particulate matter, biological molecules, and more, stemming from sources such as vehicle emissions, industrial operations, agriculture, and natural events. Nitrogen dioxide (NO2), among these harmful gases, is notably prevalent in densely populated urban regions. Given...
-
Increasing Energy Efficiency and Productivity of the Comminution Process in Tumbling Mills by Indirect Measurements of Internal Dynamics—An Overview
Publication -
Indirect Relationship between Alcoholics Anonymous Spirituality and Their Hopelessness: The Role of Meaning in Life, Hope, and Abstinence Duration
Publication -
Selfishness Detection in Mobile Ad Hoc Networks: How Dissemination of Indirect Information Turns into Strategic Issue
PublicationDla środowiska sieci mobilnej ad hoc przedyskutowano wymienność pomiędzy wydatkiem energetycznym węzła egoistycznego a obniżaniem jego metryki reputacyjnej. Badania symulacyjne wskazują, że atakom polegającym na selektywnym usuwaniu pakietów można przeciwdziałać poprzez datacentryczny system reputacyjny bazujący na potwierdzeniach końcowych, który nakazuje jednakowo uaktualniać metryki reputacyjne dla wszystkich węzłów na źle zachowującej...
-
The development of an indirect ELISA for the detection of goose parvovirus antibodies using specific VP3 subunits as the coating antigen
PublicationIn Poland, the leader in goose production in Europe, goose parovirus infection, or Derzsy’s disease (DD), must be reported to the veterinary administration due to the serious economic and epizootic threat to waterfowl production. Prophylactic treatment for DD includes attenuated live or inactivated vaccines. Moreover, the control of DD includes the monitoring of maternal derived antibody (MDA) levels in the offspring and antibody...
-
Indect input to image processing
Publication -
Direct detection of quantum entanglement
PublicationBasing on positive maps separability criterion we propose the experimentally viable, direct detection of quantum entanglement. It is efficient and does not require any a priori knowledge about the state. For two qubits it provides a sharp (i.e., “if and only if”) separability test and estimation of amount of entanglement. We view this method as a new form of quantum computation, namely, as a decision problem with quantum data structure.
-
Direct detection of quantum entanglement
PublicationPoddano dyskusji teorię splątania w kontekście historycznym. Omówiono detekcję splątania przy użyciu sieci złożonej z bramek kwantowych.
-
Calibration of the thermal desorption-gas chromatography-mass spectrometry system using standards generated in the process of thermal decomposition of chemically modified silica gel
Publication -
Applicability of glass fiber as a support material for generation of gase ous standard mixtures using thermal decomposition of the surface compound. Calibration of analytical equipment.
PublicationW pracy przedstawiono technikę sporządzania gazowych mieszanin wzorcowych(składnikiem mierzonym był eten) w oparciu o termiczny rozkład związków powierzchniowych. Jako nośnik dla związku powierzchniowego zastosowano włókno szklane. W temperaturze 245 stopni Celsjusza związek powierzchniowy ulega rozkładowi bądź przegrupowaniu uwalniając znaną ilość analitu (etenu). Technika ta umożliwia sporządzanie gazowych mieszanin...
-
Development of advanced machine learning for prognostic analysis of drying parameters for banana slices using indirect solar dryer
PublicationIn this study, eXtreme Gradient Boosting (XGBoost) and Light Gradient Boosting (LightGBM) algorithms were used to model-predict the drying characteristics of banana slices with an indirect solar drier. The relationships between independent variables (temperature, moisture, product type, water flow rate, and mass of product) and dependent variables (energy consumption and size reduction) were established. For energy consumption,...
-
IMPACT OF DIRECT CURRENT ON NITRIFYING BIOMASS
PublicationEffects of short term exposure of nitrifying biomass to direct current were studied. DC was applied to mixed liquor from municipal BNR plant using graphite electrodes in no substrate limiting conditions. Both, ammonia oxidizing bacteria (AOB) and nitrite oxidizing bacteria (NOB) populations were affected by the current, however in opposite ways. The AOB population activity was inhibited by applied voltage. Activity decrease was...
-
State of Deliverable D1.1 of INDECT Project
Publication