Filters
total: 883
-
Catalog
- Publications 627 available results
- Journals 3 available results
- People 31 available results
- Inventions 8 available results
- Projects 6 available results
- Laboratories 1 available results
- Research Teams 3 available results
- Research Equipment 9 available results
- e-Learning Courses 60 available results
- Open Research Data 135 available results
Search results for: KOROZJA AC
-
Resonant DC link inverters for AC motor drive systems – critical evaluation
PublicationIn this survey paper, resonant and quasiresonant DC link inverters are reexamined for AC motor drive applications. Critical evaluation of representative topologies is based on simulation and waveform analysis to characterize current/voltage stress of components, control timing constraints and feasibility. A special concern over inverter common-mode voltage and voltage gradient du/dt limitation capacity is discussed for motor bearing...
-
High Frequency Harmonics Emission of Modern Power Electronic AC-DC Converters
PublicationModern AC/DC converters with bidirectional power flow employing PWM boost topology generate harmonic distortions of input current in relatively high frequency range tightly related to modulation carrier frequency. These frequencies and its multiples in typical applications are usually located in frequency range from single up to several of kHz. Increased harmonic emission in this frequency range can easily and harmfully influence...
-
The influence of frequency controlled ac drives on vibration and audible noise level on ships
PublicationOkreślono korelacje między zakłóceniami elektrycznymi a wibracjami i hałasem w okrętowych układach napędowych z przemiennikami częstotliwości. Wskazano na destrukcyjny wpływ tych czynników na jakość życia załóg pływających.
-
Korozja chlorkowa kompozytów popiołowo-cementowych modyfikowanych dodatkiem włókien szklanych i stalowych.
PublicationCelem pracy jest zbadanie wpływu modyfikacji drobnoziarnistych kompozytów popiołowo-cementowych dodatkiem niewielkich ilości włókienszklanych i stalowych na ich właściwości techniczne i odpornoiść na korozję chlorkową. Ograniczenie ilości cementu oraz zastąpienie znacznej części kruszywa popiołem lotnym i dodatek włókien losowo roproszonych stanowi próbe uzyskania ochrony materiałowo-strukturalnej przed korozją.
-
Odporność korozyjna staliwa wysokochromowego
PublicationBadano odporność korozyjną staliwa wysokochromowego w dwóch stanach: lanym i po obróbce cieplnej - hartowaniu i odpuszczaniu. Stwierdzono korzystny wpływ obróbki cieplnej na odporność korozyjną, ocenianą metodą badania polaryzacji i impedancji.
-
Badania przyczyn korozji rury preizolowanej z instalacji CO
PublicationWykonano mikroanalizę nalotów i produktów korozji występujących na powierzchni rury na podstawie badań na skaningowym mikroskopie elektronowym oraz badań metalograficznych makroskopowych powierzchni z osadami i przekrojów rury. Sformułowano wnioski.
-
Impedancyjne badanie korozji wżerowej. Impedance measurements of pitting corrosion
PublicationKryteria zachodzenia korozji wżerowej związane są z badaniami tego zjawiska metodą cyklicznej polaryzacji i opierają się na wartości gęstości prądu lub bezwzględnej wartości prądu płynącego w układzie. Na podstawie przeglądu literaturowego wybrano cztery kryteria stosowane przy badaniu stali stopowych metodą cyklicznej polaryzacji. Dla warunków prądowych odpowiadających kryteriom zachodzenia korozji wżerowej przedstawiono widma...
-
Badania przyczyn korozji grzejnika wykonanego ze stali nierdzewnej
PublicationWykonano badania mające na celu ustalenie przyczyn korozji elementów grzejnika. Sformułowano wnioski.
-
Współczesne sposoby monitorowania korozji podpokładowej metodą emisji akustycznej
PublicationNa wstępie opracowania przedstawiono krótką charakterystykę procesu korozji podpokładowej oraz problemy związane z jej monitorowaniem. W dalszej części opisano metodę emisji akustycznej, opracowaną przez Katedrę Technologii Okrętu, Systemów Jakości i Materiałoznawstwa we współpracy z partnerami w VII Programie Ramowym Unii Europejskiej w projekcie o akronimie CORFAT. W dalszej części przedstawiono krótką charakterystykę samego...
-
Właściwości mechaniczne złączy różnoimiennych stali odpornych na korozję
PublicationArtykuł przedstawia właściwości mechaniczne złączy różnoimiennych stali typu duplex oraz austenitycznej typu 316L otrzymanych za pomocą spawania automatycznego łukiem krytym (SAW). Wykazano możliwość wykorzystania wysokowydajnej metody spawania automatycznego łukiem krytym do łączenia blach zbiorników statków do przewozu chemikaliów. Uzyskano złącza o zadawalających właściwościach mechanicznych spełniających wymagania towarzystwa...
-
Podatność złączy spawanych stopów aluminium na korozję warstwową.
PublicationPrzedstawiono wyniki badań trzech stopów grup Al-Mg i Al-Zn-Mg na korozję warstwową. Wykazano, że mimo zróżnicowanego składu odporność stopów jest podobna, zaś największa korozja występuje w spoinie.
-
Ochrona betonu przed korozją olejową przez impregnację polimerami.
PublicationDługoletnie odziaływanie oleju na beton w konstrukcjach budynkow jest zjawiskiem stosunkowo częstym. Badania takiego betonu poprzez wykonanie odwiertów lub metodami nieniszczącymi wykazywały obniżenie wytrzymałości na ściskanie. Przeprowadzono badania betonu zabezpieczonego przed wnikaniem oleju poprzez impregnację kompozytami żywicznymi oraz poprzez uszczelnienie struktury przez zastosowanie mikrokrzemionki.
-
Analysis of AC/DC/DC Converter Modules for Direct Current Fast-Charging Applications
PublicationThe paper is a comprehensive laboratory comparison study of two galvanic isolated solution off-board battery chargers: (1) Si-based cost-effective case, and (2) SiC-bidirectional ready for vehicle to grid concept case. All circuits are modular, and in both cases the DC/DC converter can be replaced according to the end user requirements (the coupled transformer remains the same and is constructed based on 12xC100 cores to avoid...
-
Electrical Tree Growth Behavior Under AC and DC High Voltage in Power Cables
PublicationThis work investigates the impact of an applied AC and DC high voltage on the electrical tree behavior in extruded cross-linked polyethylene (XLPE) insulation based on simulation and experimental validation. Extensive partial discharge (PD) testing methods are being implemented for high voltage cables under AC voltage for monitoring their condition. However, these PD testing methods cannot be utilized for power cables under DC...
-
Badanie wpływu wyższych harmonicznych na czułość wyłączników różnicowoprądowych typu AC i A
PublicationW ostatnich latach coraz szerzej stosuje się pośrednie przemienniki częstotliwości i inne przekształtniki. Prądy przy zwarciach doziemnych w takich obwodach mogą być silnie odkształcone. Wyższe harmoniczne w prądzie różnicowym znacząco wpływają na działanie wyłączników różnicowoprądowych. W referacie przedstawiono wyniki badań wpływu wyższych harmonicznych prądu różnicowego na rzeczywisty prąd zadziałania wyłączników różnicowoprądowych....
-
Badanie wpływu wyższych harmonicznych na czułość wyłączników różnicowoprądowych typu AC i A
PublicationW ostatnich latach coraz szerzej stosuje się pośrednie przemienniki częstotliwości i inne przekształtniki. Prądy przy zwarciach doziemnych w takich obwodach mogą być silnie odkształcone. Wyższe harmoniczne w prądzie różnicowym znacząco wpływają na działanie wyłączników różnicowoprądowych. W artykule przedstawiono wyniki badań wpływu wyższych harmonicznych prądu różnicowego na rzeczywisty prąd zadziałania wyłączników różnicowoprądowych....
-
Jarosław Guziński prof. dr hab. inż.
PeopleJaroslaw Guzinski received M.Sc., Ph.D. and D.Sc. degrees from the Electrical Engineering Department at Technical University of Gdansk, Poland in 1994, 2000 and 2011 respectively. Since 2016 he is Associate Professor at Gdansk University of Technology. Currently he is the head of the Department of Electric Drives and Energy Conversion. From 2006 to 2009 he was involved in European Commission Project PREMAID Marie Curie, ‘Predictive...
-
Microbiological corossion of metallic products as a result of biofilm
PublicationWarunkiem do pojawienia się korozji mikrobiologicznej jest utworzenie na powierzchni metalu biofilmu. Zawiera on biologicznie czynne mikroorganizmy wraz z produktami ich przemian metabolicznych. Biofilm ogranicza dyfuzję produktów metabolizmu wytwarzanych przez poszczególne komórki mikrokolonii. Powoduje to, że produkty uboczne tych przemian gromadzą się w bezpośrednim sąsiedztwie metalu. Gdy powierzchnia metalu nie jest odporna...
-
High temperature corrosion of evaporator tubes in low-emission steam boilers
PublicationW artykule opisano zjawisko korozji wysokotemperaturowej rur ekranowych kotłów parowych niskoemisyjnych. Przeprowadzono badania rur po eksploatacji. Wykonano badania składu chemicznego zgorzelin. Stwierdzono, że główną przyczyną pocienienia rur na wyższych poziomach jest korozja siarkowa, natomiast na poziomach niższych oddziaływanie stopionych soli.
-
Nowa oferta dydaktyczna ''Inżynieria Korozyjna''
PublicationPrzedstawiono nową ofertę dydaktyczną realizowaną przez Katedrę Elektrochemii, Korozji i Inżynierii Materiałowej o profilu korozyjnym. Opisano program studiów na nowo utworzonym międzywydziałowym kierunku studiów Inżynieria Materiałowa, który dotyczy kierunku dyplomowania Inżynieria Korozyjna.
-
Wpływ zawartości jonów chlorkowych w brzeczce i piwie na korozję wżerową instalacji browarniczych
PublicationPrzedstawiono wyniki badań wpływu zawartości jonów chlorkowych w piwie na zagrożenie korozja wżerową stali stopowej. Badania wskazują, że wzrost stężenia jonów chlorkowych zwiększa zagrożenie korozją wżerową, występuje brak prostej korelacji pomiędzy zawartością jonów chlorkowych a podatnością stali na korozję.
-
Ekspertyza dotycząca przyczyn powstawania korozji ram aluminiowych okien uchylnych
PublicationDokonano analizy spektroskopowej i mikroskopowej produktów korozji na dostarczonym stopie aluminium, oceniono podatność materiału na korozję w aplikowanym środku myjącym oraz oznaczono wytrzymałość powłoki organicznej na stopie aluminium
-
Emisja akustyczna podczas korozji stopów na bazie metali lekkich
PublicationPrzedstawiono wyniki badań elektrochemicznych metodą polaryzacji cyklicznej oraz emisji akustycznej technicznie czystego aluminium(stop1050) oraz magnezu. W przypadku aluminium aktywność akustyczna jest związana z inicjacją i wzrostem wżerów. Aktywność akustyczna magnezu występuje w obszarze inicjacji i wzrostu wżerów oraz w czasie repasywacji wżerów.
-
Ocena zagrożenia rurociągów podziemnych korozją wywoływaną przez prąd przemienny
PublicationScharakteryzowano interferencje prądu przemiennego na rurociągach podziemnych. Przedstawiono przyjętą w normie PKN-CEN/TS 15280 hipotezę mechanizmu korozji wywoływanej przez prąd przemienny w defektach powłoki rurociągów chronionych katodowo. Omówiono kryteria oceny zagrożenia korozyjnego rurociągów wraz z wynikami badań terenowych, które wykorzystywano przy opracowaniu normy.
-
Zastosowanie transformacji STFT w monitorowaniu korozji techniką intermodulacji częstotliwościowej
PublicationProcesy korozji są zjawiskiem o charakterze nieliniowym. Z tego względu sygnał pobudzający o kształcie sinusoidalnym generuje odpowiedź, będącą złożeniem wielu składników harmonicznych o różnych częstotliwościach harmonicznych i intermodulacyjnych. Od wielu lat trwają zastosowania analizy harmonicznej w monitorowaniu korozji. Praca prezentuje zastosowanie techniki analizy harmonicznej do monitorowania korozji w środowiskach wodnych....
-
Metoda diagnozowania korozji metali na podstawie pomiarów szumów elektrochemicznych
PublicationPrzedstawiono metodę diagnozowania korozji metali przy wykorzystaniu wyników obserwacji fluktuacji prądu i napięcia (szumów elektrochemicznych), powodowanych reakcjami chemicznymi występującymi na powierzchni metali. Przedstawiono sposób pomiaru szumów elektrochemicznych za pomocą przygotowanych systemów pomiarowych. Podano wybrane metody analizy obserwowanych szumów, stosowane do oceny szybkości oraz rodzaju procesów korozji.
-
Modeling of Common Mode Currents Induced by Motor Cable in Converter Fed AC Motor Drives
PublicationInvestigation of conducted EMI generation in AC motor fed by pulse width modulated frequency converters requires to consider parasitic capacitances in converters, motor windings and feeding cables to be taken into account. Motor voltage transients and related common mode currents are significantly correlated with resonance effects occurring in load circuits. An analysis of frequency converter load impedance-frequency characteristics...
-
Feasibility Study of Three-Phase Modular Converter for Dual-Purpose Application in DC and AC Microgrids
PublicationThe modern concept of a universal converter is intended as a power converter (PC) suitable for application in both dc or ac grids using the same external connectors. This novel family was recently proposed to allow easier integration of renewable energy sources and energy storage systems (ESSs), interfacing with dc/ac grids and/or loads with a minimum redundancy of power switches and passive elements. This kind of solution and...
-
DC and AC Conductivity, Biosolubility and Thermal Properties of Mg-Doped Na2O–CaO–P2O5 Glasses
PublicationBioactive glasses have recently been extensively used to replace, regenerate, and repair hard tissues in the human body because of their ability to bond with living tissue. In this work, the effects of replacing Na2O with MgO on the electrical, biosolubility, and thermal properties of the target glass 10Na2O–60P2O5–30CaO (in mol%) were investigated. The electrical properties of the glasses were studied with the impedance spectroscopy...
-
The new SDMT-family of servo-drives for CNC systems with AC permanent magnet synchronous motors
PublicationW artykule przedstawiono strategię sterowania podstawowe parametry oraz wyniki badań nowej rodziny serwonapędów typu SDMT. Układ sterowania serwonapędu zbudowano na procesorze sygnałowym TMS320F2812 firmy Texas Instruments. W serwonapędzie zastosowano metodę sterowania tupu FOC (ang. Field Oriented Control). Regulatory położenia, prędkości i momentu zreali-zowano na bazie klasycznego regulatora PID z układem ograniczenie sygnału...
-
RCDs Tripping in the Range from DC to AC 50 kHz for Slowly Rising Residual Current
PublicationThe wide use of power electronic converters means that in many low-voltage systems earth fault currents containing components from DC to AC of various frequencies have to be taken into account. Due to the tendency to increase the modulation frequency in converters, components of higher frequencies may be in the order of several tens of kilohertz. Therefore, it is very important to verify the behavior of devices for protection against...
-
Feasibility Study of Three-Phase Modular Converter for Dual-Purpose Application in DC and AC Microgrids
PublicationThe modern concept of a universal converter is intended as a power converter suitable for application in both dc or ac grids using the same external connectors. This novel family was recently proposed to allow an easier integration of renewable energy sources and energy storage systems, interfacing with dc/ac grids and/or loads with a minimum redundancy of power switches and passive elements. This kind of solution and applications...
-
Stress corossion cracking susceptibility of dissimilar stainless steels welded joints
PublicationW artykule przedstawiono wyniki badań odporności na naprężeniowe pękanie korozyjne złączy różnoimiennych stali odpornych na korozję; austenitycznej 316L oraz typu duplex 2205. Badania próbek przeprowadzono techniką odkształcania z małą prędkością w agresywnym środowisku roztworu chlorku magnezowego. Wyniki badań korozyjnych uzupełniono analizą metalograficzną z obszarów przełomów.
-
The conducted immunity test of an AC adaptor in accordance with EMC standards
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the ac adaptor PHILIPS DC power supply SBC 6654. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz...
-
High temperature corrosion of the cobalt base clad layers
PublicationNapawane warstwy wykonane ze stopu kobaltu poddano utlenianiu w temperaturach 650 stopni C i 750 stopni C oraz korozji w spalinach. Proces utleniania był prowadzony 2 sposobami, izotermicznie przez 100 godzin i cyklicznie pzez 200 godzin. Korozja w spalinach przebiegała cyklicznie przez 200 godzin w temperaturze 650stopni C. Warstwy napawano metodą laserową i plazmową (PTA). Badano stabilność termiczną procesu utleniania warstw...
-
Corrosion of titanium biomaterials, mechanisms, effects and modelisation
PublicationBadania in vivo oraz in vitro wskazują na bardzo małą szybkość korozji biostopów tytanu.Najczęstsza przycyną jest korozja ogólna i lokalna oraz korozja frettingowa. Trzy możliwe mechanizmy to: rozpuszczanie warstwy tlenku tytanu, dyfuzja pierwiastków przez warstwę tlenkową oraz reakcje elektrochemiczna w środowisku korozyjnym odsłoniętego metalu. Procesy korozyjne prowadzą do obluzowania implantów i poważnych schorzeń. Standardowe...
-
Speed sensorless ac drive with inverter output filter and fault detection using load torque signal
PublicationIn this paper, a sensorless induction motor (IM) drive using speed observer system is presented. The system includes load torque computation for gear fault detection. Nonlinear control method is adopted for controlling the motor over a wide speed range. An LC filter for smoothing current and voltage waveforms is used at the output of the voltage inverter. The use of filter imposes more building of the used observer to avoid using...
-
Motor Cable Influence on the Conducted EMI Emission of the Converter Fed AC Motor Drive. - Vol. 1
PublicationInvestigation of conducted electromagnetic interference in AC motor drives fed by pulse width modulated voltage converters requires considering parasitic capacitances in converters, motor windings and feeding cables to be taken into account. Motor voltage transients and related conducted electromagnetic emission are significantly correlated with resonance effects occurring in load circuits. The levels of intensity of these phenomena...
-
High Frequency Conducted Emission in AC Motor Drives Fed By Frequency Converters: Sources and Propagation Paths
PublicationProvides a concise and thorough reference for designing electrical and electronic systems that employ adjustable speed drives Electrical and electronic systems that employ adjustable speed drives are being increasingly used in present-day automation applications. They are considered by many application engineers as one of the most interfering components, especially in a contemporarily faced industrial environment. This book fills...
-
Speed Sensorless AC Drive with Inverter LC Filter and Fault Detection Using Load Torque Signal
PublicationThe industrial development in recent years has seen a major increase in the use of induction motors, whereby the cost has to be as low as possible and the lifetime as long as possible. To follow up this desire, investigations in this area have become very intense. For that reason, this paper presents a solution for driving an induction motor and simultaneous fault detection with no need for additional sensors. In order to achieve...
-
Korozja naprężeniowa stali 14hnmbcu w środowisku wody morskiej.Stress corrosion cracking of 14hnmbcu steel in sea-water.
PublicationW pracy przedstawiono zagadnienia niszczenia środowiskowego stali o wysokiej wytrzymałości na konstrukcje morskie. Podatność stali 14HNMBCu i jej złącza spawanego na naprężeniowe pękanie korozyjne badano w oparciu o próbę powolnego rozciągania. Próby wykonano w środowisku powietrza oraz wody morskiej przy polaryzacji katodowej.
-
Charakterystyka korozji typu pylenie metalu w rafineryjnej instalacji platformingu CCR
PublicationW artykule przedstawiono charakterystykę procesu pylenia metalu w stali 9Cr-1Mo eksploatowanej w piecach instalacji platformingu CCR. Wykazano, że mechanizm niszczenia stali nie zależy od czasu eksploatacji i od stopnia konwersji wsadu, a krótkotrwały wzrost stężenia związków siarki we wsadzie może zwiększyć szybkość tworzenia pyłu.
-
Wpływ zmiany parametrów materiałowych na zagrożenie korozją biologiczną w budynkach.
PublicationPrzedstawiono analizę zjawiska cieplno-wilgotnościowego dla przegród, w których wystąpiła korozja biologiczna. Budynki, w których wystąpiło zagrzybienie zostały wykonane zgodnie z normami budowlanymi. Artykuł wyjaśnia mechanizm powstawania korozji biologicznej w przegrodach budowlanych
-
Zastosowanie techniki emisji akustycznej w badaniach korozji wżerowej stali austenitycznej
PublicationPrzedstawiono przegląd różnych zastosowań emisji akustycznej (AE) w badaniach korozji wżerowej stali austenitycznej. Wykorzystanie emisji akustycznej w przypadku tego rodzaju korozji nie jest przypadkowe, ponieważ korozja wżerowa jest najgroźniejszym typem korozji, atakującym różne materiały konstrukcyjne takie jak stal. Prezentowana praca przeglądowa dostarcza przydatnych informacji o naturze pomiarów akustycznych, które wykazują...
-
Monitorowanie szybkości korozji stali w Martwej Wiśle metodą syntezy harmonicznej
PublicationPrzedstawiono wybrane wyniki badań polowych nad przydatnością praktyczną opracowanej niedawno metody syntezy harmonicznej (SH) do monitorowania szybkości korozji metali. Badania dotyczyły stali węglowej korodującej w środowisku słonawym wody Martwej Wisły. Korozję stali monitorowano przez okres ok. 20 dni w odstępach dwudniowych za pomocą umieszczonych w wodzie sond trójelektrodowych korzystając z przenośnej aparatury Solartron...
-
Badania elektrochemiczne wpływu powłok zawierających grafit na korozję stali konstrukcyjnej
PublicationPrzeprowadzono badania elektrochemiczne powłok przewodzących zawierających grafit. W przypadku bezpośredniego kontaktu elektrycznego powłok zawierających grafit ze stalą konstrukcyjną w środowisku elektrolitycznym może powstawać ogniwo galwaniczne. Stal konstrukcyjna w tym przypadku pełni rolę anody, co stwarza duże zagrożenie korozyjne. Przeprowadzono badania szybkości korozji stali konstrukcyjnej w wyniku działania ogniwa galwanicznego...
-
System monitorowania korozji w instalacjach wodnych platformy wydobywczej Baltic Beta
PublicationRealizacja doktoratu rozwiązała problemy korozyjne w jednym ze strategicznych obszarów procesu eksploatacji ropy. Polegała na uruchomieniu monitoringu korozji w instalacji zatłaczającej wodę morską do złoża ropy, na platformie wydobywczej firmy LOTOS Petrobaltic. Wdrożono automatyczny system monitorowania korozji metodą polaryzacji liniowej, oszacowano korozyjność uzdatnionej wody, zidentyfikowano rodzaje korozji występujące w...
-
Wyjaśnienie przyczyn korozji rur kotła, wytwornicy pary technologicznej instalacji Olefiny
PublicationWykonano badania przyczyn korozji rurek wytwornicy pary instalacji Olefiny. Przeprowadzono badania metalograficzne oraz SEM i EDX produktów korozji
-
Mechanizm korozji stopu Al-Si nadtapianego laserowo w niskiej temperaturze.
PublicationBadano odporność na korozję elektrochemiczną stopu Al-Si metodami krzywych polaryzacji i impedancji. Ujawniono wyraźny wzrost odporności na korozję stopu nadtapianego laserowo po schłodzeniu do niskiej temperatury. Zaproponowano mechanizm korozji warstwy wierzchniej stopu.
-
System monitorowania szybkości korozji instalacji wodnych - to jakość wody. Cz.1
PublicationCelem monitorowania korozyjnego jest zastosowanie środków zaradczych, pozwalających na przedłużenie czasu eksploatacji instalacji i urządzeń, a także kontrola i ochrona środowiska oraz bezpieczeństwo ludzi. Pomiary szybkości korozji pozwalają przewidzieć powstanie perforacji i innych uszkodzeń korozyjnych. Monitorowanie pozwala także określić rozległość zagrożeń korozyjnych. Bardzo ważnym aspektem monitorowania korozyjnego jest...