Filters
total: 1086
-
Catalog
displaying 1000 best results Help
Search results for: IMPEDANCE CARDIOGRAPHY
-
Impedance analysis of Portevin-Le Chatelier effect on aluminium alloy
Publication -
Electrochemical impedance studies of AB5-type hydrogen storage alloy
Publication -
Evaluation of pitting corrosion by means of dynamic electrochemical impedance spectroscopy
Publication -
Ionophores in polymeric membranes for selective ion recognition; impedance studies
PublicationBadania impedancyjne membran zawierających jonofory selektywne na kation Na+ (L1) i Cs+(L2) wykazały, ze stala dielektryczna materiału membrany zależy od typu uzytego plastyfikatora i zmienia się w zakresie od 28 do 60. Rezystancja membran zawierających ligand L1 i L2 wynosi 0.15 -1.4 Mohm w zależności od stężenia elektrolitu zewnnetrznego. Testowona dwa typy elektrod jonoselektywnych: elektrody typu ASS z polimerem przewodzącym...
-
The influence of parameters of input probe on the error of high impedance measurement
PublicationW artykule przedstawiono sondę do pomiaru wysokich impedancji w zakresie 1kohm<|Zx|<100Gohm przeznaczoną do dołączenia do analizatorów typu gain-phase. Przeanalizowano wpływ parametrów sondy (pojemności pasożytnicze, toleranca rezystorów określających wzmocnienie wzmacniacza) na dokładność wyznaczenia modułu i argumentu zespolonego stosunku sygnałów wydzielonych w sondzie. Zamieszczono wyniki symulacji i pomiarów, pozwalające na...
-
The contribution of blood-flow-induced conductivity changes to measured impedance
PublicationW pracy rozwazane sa zmiany przewodnosci zachodzace w anizotropowym osrodku i ich wplyw na mierzona rezystancje. Uzyskano to za pomoca rozszerzenia wzoru Geselowizta na przypadki anizotropowe. Wykazano, ze tylko te skladowe zmian przewodnosci wplywaja na mierzona rezystancje, dla ktorych odpowiadajacy im skladnik pola eklektrycznego byl niezerowy.Wyniki te zastosowanu do zmian rezystywnosci wywolanych zmiananmi przewodnosci plynacej...
-
Evaluation of pitting corrosion by means of dynamic electrochemical impedance spectroscopy.
PublicationPrzeprowadzono badania stali stopowej 304L metodą dynamicznej elektrochemicznej spektroskopii impedancyjnej w warunkach liniowo zmieniającego się potencjału. Określono ogólny schemat układu elektrycznego dla elektrody ulegającej korozji. Przeprowadzone badania pozwalają na jednoczesne badanie zachowania się stali stopowej w stanie pasywnym, podczas stanu przejściowego (metastabilne tworzenie się i repasywacja wżerów) oraz w stanie...
-
The Goertzel filter-bank usage in the non-stationary impedance measurement.
PublicationArtykuł prezentuje metodę pomiaru parametrów impedancyjnych w warunkach niestacjonarnych bazującą na próbkowaniu sygnałów pomiarowych i przetwarzaniu cyfrowym. Zaproponowano i przeanalizowano zastosowanie banku filtrów Goertzela. Porównano zaproponowane podejście z tradycyjnie stosowaną metodą STDFT. Przedstawiono wynik symulacji i pomiarów.
-
Dynamic electrochemical impedance spectroscopy of the first order electrode reaction
PublicationCiągłe transformaty STFT sinusoidalnego sygnału pobudzenia i odpowiedzi prądowej zostały wyznaczone dla reakcji elektrodowej pierwszego rzędu. Wyznaczono impedancję elektrody w łącznej dziedzinie czasu i częstotliwości. Wykonano pomiary dla reakcji redukcji Cd(II) na rtęciowej elektrodzie kroplowej w funkcji potencjału. Przedstawiono możliwość wyznaczenia chwilowych widm impedancyjnych. Opisano zależność rezystancji przeniesienia...
-
Microsystem for measurement of impedance sensors parameters.Optoelectronic and electronic sensors V.
PublicationW artykule przedstawiono mikrosystem do pomiaru parametrów impedancyjnych czujników o module impedancji z przedziału 100ohm-1Gohm. Zastosowana w mikrosystemie technika cyfrowego przetwarzania sygnałów, pozwoliła na uzyskanie szerokiego zakresu częstotliwości pomiarowych, zwłaszcza bardzo niskich od 100uHz do 1MHz, przy zachowaniu prostej konstrukcji zapewniającej jego niską cenę. Mikrosystem zrealizowano w formie przyrządu...
-
Impedancyjne badanie korozji wżerowej. Impedance measurements of pitting corrosion
PublicationKryteria zachodzenia korozji wżerowej związane są z badaniami tego zjawiska metodą cyklicznej polaryzacji i opierają się na wartości gęstości prądu lub bezwzględnej wartości prądu płynącego w układzie. Na podstawie przeglądu literaturowego wybrano cztery kryteria stosowane przy badaniu stali stopowych metodą cyklicznej polaryzacji. Dla warunków prądowych odpowiadających kryteriom zachodzenia korozji wżerowej przedstawiono widma...
-
Evaluating and predicting the performance of organic coatings using impedance spectroscopy
PublicationPrzedstawiono wyniki badań cyklicznych, sinusoidalnych zmian temperatury na powłokowe systemy ochronne o skrajnie różnych właściwościach antykorozyjnych. Porównano zachowanie nowej powłoki poliestrowej typu "coil-coating" na ocynkowanej stali uprzednio eksponowanej w warunkach atmosferycznych alkidowej powłoki malarskiej na podłożu stalowym. Badania przeprowadzono przy zastosowaniu techniki spektroskopii impedancyjnej. Stwierdzono...
-
Identification and localization of organic coating degradation onset by impedance imaging
Publication -
Assessment of organic coating degradation via local impedance imaging
PublicationThe paper presents a new approach to organic coating condition evaluation at micrometer scale using localized impedance measurements. It is based on atomic force microscopy (AFM) in contact mode. Impedance is measured between conductive AFM tip and metal substrate covered with organic coating. A single-frequency voltage perturbation signal is applied between the electrodes and current response signal is registered. As the tip is...
-
Electrochemical impedance studies of AB5 -type hydrogen storage alloy
PublicationDo wyznaczenia własności stopu AB5 wykorzystano elektrochemiczną spektroskopie impedancyjną. Badania impedancyjne wykonano podczas chronowoltamperometri cyklicznej oraz cykli ładowania i rozładowania elektrody. Interpretacja uzyskanych w trybie potencjostatycznym wyników pozwoliła na dalszą interpretacje wyników uzyskanych w trybie galwanostatycznym. Proponowana metodologia umożliwia śledzić parametry elektryczne badanego układu...
-
Monitoring of breast tissue thermo-ablation by means of impedance measurements
PublicationW pracy przedstawiono rozważania dotyczące monitorowania jakości termoablacji zmian nowotworowych w piersi przy pomocy pomiarów impedancyjnych. Pokazano prototypowe konstrukcje sond do termoablacji jak również zaprezentowano wyniki symulacji i pierwszych eksperymentów. A usefulness of a developed probe combining power delivery to ablated breast tumour and simultaneous impedance measurements is discussed in the paper. It consists...
-
Monitoring of CRT by means of impedance multiple measurements - simulation studies
PublicationCardiac resynchronization therapy (CRT) is a very promising treatment for patients with congestive heart failure. An Impedance Cardiography (ICG) is used for evaluation of heart mechanical activity. A simulation study with the use of a FEM model was performed. The developed realistic model of the thorax, based on CT data obtained from examination of a 68-year-old man, consisted of 212 000 tetrahedral elements. Different configurations...
-
Analysis of thoracic regional impedance changes using PCA approach
PublicationA multichannel impedance and one lead electrocardiographic recording system has been developed. The impedance measurement unit is built using a four-electrode technique. It consists of a sinusoidal, 40 kHz, current source and five measurement channels. Circumferential current electrodes have been located at a neck and an abdomen. Voltagemeasurement disk electrodes formed five two-electrode measurement ports. The impedance change...
-
An Application Supporting Gastroesophageal Multichannel Intraluminal Impedance-pH Analysis
PublicationDue to a significant rise in the number of patients diagnosed with diseases of the upper gastrointestinal tract and the high cost of treatment, there is a need to further research on one of the most popular diagnostic tests used in this case – esophageal Multichannel Intraluminal Impedance and pH measurement. This may lead to finding new diagnostically relevant information, used to quicken and improve the diagnostic procedure....
-
IMPEDANCE MEASUREMENT MODULE FOR GAS SENSORS WITH TEMPERATURE CONDITIONING FEATURE
PublicationThe paper presents an impedance measurement module which is aimed for gas sensor. Sensor’s heater temperature conditioning and modulation feature is available in order to allow implementation of different techniques improving selectivity and sensitivity of gas sensors. The measurement module uses three-parameter sine-fitting technique for impedance measurement. To monitor sensor temperature, the resistance of the sensor’s heater...
-
Application of different modes of nanoscale impedance microscopy in materials research
PublicationIn recent years, there is noticeable interest in application of various types of scanning probe microscopy in material science research. One of them is contact atomic force microscopy combined with local impedance measurements, known as nanoscale impedance microscopy. Literature references present its application in investigations of new materials, microelectronics diagnostics, or research of protective coatings performance. In...
-
A complete impedance analysis of electrochemical cells used as energy sources
PublicationA comprehensive description of impedance ofelectrochemical systems has been presented, along withthe assumptions of the method used. In this method, amultisinusoidal current excitation signal is used. Thechanges of potential of both the electrodes and thepotential difference between these electrodes are allregistered simultaneously as a function of time. Theproposed method offers the possibility of separatelydetermining the instantaneous...
-
Evaluation of the fast impedance spectroscopy method in the laboratory measurement system
PublicationIn this paper the method for fast impedancespectroscopy of technical objects with very high impedance(|Zx| ≥ 1 GΩ) is evaluated by means of simulation and practicalexperiment. The method is based on excitation of an object, witha square pulse and measurements of voltage and currentresponses with DAQ card. The object impedance spectrum isobtained with use of continuous Fourier transform. Someimprovements of the method concerned...
-
Uncertainty estimation of loop impedance measurement determined by the vector method
PublicationThis article presents a detailed analysis of uncertainty estimation of loop impedance measurement determined by the vector method. The analysis includes the following estimates: resistance variance, voltage variance and time measurement variance. This paper presents a methodology for estimating the combined standard uncertainty of loop impedance by the vector method. The vector method allows to determine loop impedance based on...
-
Impedance Studies of Phosphate-iron Glasses Containing Niobium and Titanium
PublicationThe ac and dc conductivity in phosphate-iron-niobate glasses with addition of titanium oxide was investigated as a function of temperature and frequency with the use of impedance spectroscopy. The topography and microstructure of glasses were investigated by the means of X-ray diffraction (XRD), scanning electron microscopy (SEM), and confocal microscopy methods. The obtained results show that all samples are amorphous but they...
-
Validation of dynamic electrochemical impedance spectrograms using autocorrelation function
PublicationValidation of impedance data is essential for checking the reliability of experimental data. Kramers – Kronig transformation is used to verify data obtained from classical Electrochemical Impedance Spectroscopy (EIS) measurements. Data obtained from Dynamic Electrochemical Impedance Spectroscopy (DEIS) could be validated in the same way, but in this case, there is no information about internal consistency between every single spectrum...
-
Local electrochemical impedance spectroscopy in dynamic mode of galvanic coupling
PublicationA novel method that combines local electrochemical impedance spectroscopy and mapping in dynamicmode is proposed. Method was validated over two galvanic couplings, namely zinc/copper and cad-mium/copper. Impedance spectrum response for all measuring points was obtained by means ofsimultaneous implementation of selected range of frequencies. Proposed method allows the measure-ment in a more time-efficient manner, at the same time...
-
Multi-objective design of miniaturized impedance transformers by domain segmentation
PublicationFast multi-objective design optimization of compact microstrip impedance transformers is discussed. Our approach exploits approximation models constructed using sampled coarse- mesh EM simulation data in a partitioned design space and response correction techniques for design refinement. Demonstra
-
The Influence of Thin Gold Electrodes on the High-Temperature Impedance of Oxide Glasses
PublicationThe influence of thin gold electrodes on the electrical measurements of glasses at high temperatures was studied using impedance spectroscopy. The impedance was measured several times over a wide frequency range from 10 mHz to 1 MHz and the temperature ranged from 213 to 673 K under air and nitrogen atmospheres. The results showed a drop in the conductivity of more than an order of magnitude at a temperature around 603 K during...
-
Local impedance imaging of boron-doped polycrystalline diamond thin films
Publication -
Determination of time delay between ventricles contraction using impedance measurements
PublicationThe paper presents a novel approach to assessment of ventricular dyssynchrony basing on multichannel electrical impedance measurements. Using a proper placement of electrodes, the sensitivity approach allows estimating time difference between chambers contraction from over determined nonlinear system of equations. The theoretical considerations which include Finite Element Method simulations were verified using measurements on...
-
A low-voltage CMOS negative impedance converter for analogue filtering applications
PublicationLow-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....
-
Theoretical description of fundamental-harmonic impedance of a two-step electrode reaction
Publication -
Investigations of the passive layer cracking by means of Dynamic Electrochemical Impedance Spectroscopy
Publication -
Application of impedance imaging to evaluation of organic coating degradation at a local scale
Publication -
Impedance-based sensing of the interlayer adhesion loss in organic coating systems
Publication -
Detection of stress corrosion cracking dynamics by dynamic electrochemical impedance spectroscopy
Publication -
Quantification of interlayer adhesion in protective coating systems using impedance spectroscopy
PublicationNowoczesne systemy powłokowe stosowane w praktyce są wielowarstwowe. Potencjalnie słabymi obszarami z punktu widzenia właściwości ochronnych są obszary międzywarstwowe. Osiągnięcie odpowiedniej przyczepności pomiędzy warstwami pozwala na polepszenie zdolności ochronnych całego zestawu. Tradycyjne metody pomiaru adhezji międzywarstwowej są destrukcyjne. Zaproponowano nową metodę oceny przyczepności międzywarstwowej przy użyciu...
-
Impedance-based sensing of the interlayer adhesion loss in organic coating systems.
PublicationZmienne parametry środowiska takie jak: temperatura,wilgotność i promieniowanie UV powodują degradację własności ochronnych powłok organicznych. Stosując sensor w postaci elektrod wykonanych z prądoprzewodzącego tuszu umieszczonych pomiędzy warstwami zestawu oraz technikę spektroskopii impedancyjnej stwierdzono możliwość monitorowania utraty adhezji międzywarstwowej.
-
Impedance studies of diffusion phenomena and ionicand electronic conductivity of cerium oxide
PublicationW pracy zbadano właściwości elektryczne tlenku ceru z wykorzystaniem spektroskopii impedancyjnej. Badania wykazały występowania zjawiska dyfuzji, które jest prawdopodobnie związane z blokowaiem jonów na granicy faz. Bazując na zaproponowanym modelu obliczono przewodność elektronowa i jonową tlenku ceru.
-
Application of the dynamic electrochemical impedance spectroscopy to investigation of spontaneous electrochemical oscillations
PublicationPrzedstawione zostały wyniki impedancyjne uzyskane podczas oscylacji prądowych miedzi w kwaśnym środowisku zawierającym jony chlorkowe. Kształt chwilowych widm impedancyjnych jest skorelowany z uzyskanym przebiegiem prądowym. Badany proces anodowego roztwarzania miedzi kontrolowany jest na przemian aktywacyjnie i dyfuzyjnie.
-
Evaluation of relative humidity effects on interfacial impedance at inter-coat interfaces.
PublicationSpektroskopia impedancyjna została zastosowana jako metoda niedestrukcyjna do oceny adhezji pomiędzy polimerowymi warstwami w ochronnym systemie powłokowym. Celem badań było stwierdzenie wpływu zewnętrznej wilgotności na impedancję międzyfazową. Badano system ochrony stosowany do ochrony samochodów. Zastosowano nowy sensor do detekcji rozwarstwienia i akumulacji wody w obszarze międzyfazy. Elektrody stanowią paski przewodzącego...
-
Detection of stress corrosion cracking dynamics by dynamic electrochemical impedance spectroscopy.
PublicationKlasyczne badania korozji naprężeniowej nie dają precyzyjnych informacji o dynamice takiego procesu korozyjnego. Nowa technika dynamicznej elektrochemicznej spektroskopii impedanyjnej, która została opracowana w Katedrze Elektrochemii, Korozji i Inżynierii Materiałowej stwarza takie możliwości. Fakt ten związany z zastosowaną metodologią analizy umożliwiającą selektywną analizą czasowo-częstotliwościową danych pomiarowych.Praca...
-
Impedance spectroscopy by means of a digital storage oscilloscope based measurement system.
PublicationW pracy przedstawiono system pomiarowy służący do badań spektroskopowych. Został on zbudowany w oparciu o szerokopasmowy oscyloskop cyfrowy. Przeprowadzono analizę dokładności pomiarów oraz przedstawiono wyniki badań kalibracyjnych i przykładowych pomiarów parametrów materiałów biologicznych.
-
The application of dynamic electrochemical impedance spectroscopy for stress corrosion cracking studies
PublicationElektrochemiczna Spektroskopia Impedancyjna (ESI) od wielu lat stanowi jedno z najważniejszych narzędzi wykorzystywanych do badania różnych procesów elektrochemicznych. Możliwość przeprowadzania badań w łącznej dziedzinie czasowo-częstotliwościowej ułatwia analizę pomiarów impedancyjnych w czasie. ESI pozwala również na analizę mechanizmu procesów elektrochemicznych w dziedzinie czasu z uwzględnieniem bardzo szybkich zjawisk, takich...
-
Investigations of the passive layer cracking by means of dynamic electrochemical impedance spectroscopy.
PublicationDynamiczna elektrochemiczna spektroskopia impedancyjna została wykorzystana do badania pękania warstwy pasywnej na austenitycznej stali wysokostopowej.Zbadano efekt narzuconego potencjału oraz naprężeń rozciągających na pękanie korozyjne stali wysokostopowej 304L w środowisku 0.5M NaCl w temperaturze pokojowej. Praca przedstawia chwilowe widma impedancyjne uzyskane dla badanego układu przy różnych wartościach potencjałów. Uzyskane...
-
Diagnosis of reference electrodes in cathodic protection systems by electrochemical impedance spectroscopy
PublicationPrzedstawiono wyniki badań laboratoryjnych i terenowych przeprowadzonych techniką elektrochemicznej spektroskopii impedancyjnej (EIS). Zaprezentowano widma impedancyjne następujących układów: elektroda odniesienia/elektroda pomocnicza; rurociąg/zakopane i przenośne elektrody odniesienia. Pokazano, że omawiana technika umożliwia badanie stanu technicznego elektrod odniesienia, co zwiększa pewność wyników pomiarów potencjału chronionej...
-
Finding the protection of lighting grounding with estimating its impulse impedance componets
PublicationOmówiono metodę rozdzielania składowych impedancji udarowej uziemień. Podano wskazania dotyczące oceny jakości ochrony odgromowej na podstawie wartości składowych impedancji udarowej.
-
Impedance Spectroscopy as a Diagnostic Tool of Degradation of Solid Oxide Fuel Cells
Publicationw pracy przedstawiono wyniki badań degradacji tlenkowych ogniw paliwowych przeprowadzone metodą spektroskopii impedancyjnej. Ogniwa paliwowe zostały przetestowane w eksperymentalnych warunkach, które pozwalają na uzyskanie szybkiego spadku wydajności ogniw paliwowych. impedancja i parametry uzyskane z dopasowania widm do elektrycznego obwodu zastępczego zostały skorelowane z poziomem degradacji elementów ogniw paliwowych - anody...
-
Investigation on accelerated impedance spectrum measurement method with multisine signal stimulation
PublicationThe paper presents an investigation on the accelerated impedance spectrum measurement method, oriented at parameter identification of technical objects modelled by a linear equivalent circuit, e.g. anticorrosion coatings.The method is based on multisine signal stimulation of an object and response analysis by triangle window filterbanks.It has several advantages, as compared with conventional point-by-point spectrum measurement....