Filters
total: 1095
-
Catalog
displaying 1000 best results Help
Search results for: IMPEDANCJA UDAROWA
-
Response features for fast EM-driven design of miniaturized impedance matching transformers
PublicationA framework for low-cost EM-driven design optimization of compact impedance matching transformers is presented. Our technique is based on a bottom-up design where design requirements for the transformer circuit are translated into specifications for its building blocks. These elementary cells are optimized using response features. Subsequently, the entire circuit is fine-tuned using local response surface approximation models and...
-
Nonlinear and linear impedance of bismuth vanadate ceramics and its relation to structural properties
PublicationThe nonlinear and linear electrical properties, topography, and microstructure of bismuth-vanadate ceramics, were studied. The structurewas observed with the use of X-ray diffraction (XRD), scanning electronmicroscopy (SEM), atomic force microscopy (AFM) and confocal microscopy methods. The obtained results showed that ceramic is porous. Two phase transitionswere determinedwith the use of DSC measurements. The linear and nonlinear ac...
-
Instantaneous impedance monitoring of synergistic effect between cavitation erosion and corrosion processes
PublicationThe most common method of determination of cavitation erosion resistance as well as the magnitude of erosion-corrosion synergistic interaction is based on the weight loss measurements. Nondestructive characterization of installations elements is in most cases impossible to perform. Also, such a measurement does not include local types of failure or alteration of operating conditions. There is an urge to elaborate a method for monitoring...
-
Impedance monitoring of carbon steel cavitation erosion under the influence of corrosive factors
PublicationW pracy przedstawiono wyniki badań degradacji stali węglowych na skutek oddziaływania erozji-korozji kawitacyjnej. Do analizy wykorzystano technikę Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej oraz funkcję ubytku masy powszechnie stosowaną do oceny odporności kawitacyjnej materiałów. Oszacowanie stopnia degradacji powierzchni, a także wpływu erozji na odporność korozyjną jest możliwe po zastosowaniu odpowiedniego elektrycznego...
-
Application of Electrochemical Impedance Spectroscopy to evaluate cathodically protected coated steel in seawater
PublicationTwo types of organic coated carbon steel (S235JR2 grade) electrodes were exposed to artificial seawater environment. One prepared type was defect free while the other one had an intentionally introduced φ0,5 cm coating defect. Both kinds of samples were polarized during the exposure to four potentials corresponding to four different cathodic protection levels. Evolution of their EIS spectra is presented in this paper. Results obtained...
-
Water uptake in protective organic coatings and its reflection in measured coating impedance
PublicationWater uptake in commercially available epoxy coating on mild steel using impedance spectroscopy and gravimetry was studied. The water content in the coating was determined using the Brasher-Kingsbury equation and various methods of coating capacitance calculation used in the literature. The obtained results were compared with reference gravimetric data. An overestimation of values obtained from impedance data in relation to gravimetric...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublicationIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Galvanostatic impedance measurements for the efficient adsorption isotherm construction in corrosion inhibitor studies
PublicationWe present an approach towards an accurate and time-efficient adsorption isotherm determination to evaluate the corrosion inhibitor interaction in electrolytic environments. The approach is based on dynamic impedance spectroscopy measurements in galvanostatic mode (g-DEIS). The studied corrosion inhibitor is continuously injected between the secondary cell and the corrosion cell. The efficiency corresponding to instantaneous inhibitor...
-
Fault Diagnostics in PEMFC Stacks by Evaluation of Local Performance and Cell Impedance Analysis
PublicationStarvation, flooding, and dry‐out phenomena occur in polymer electrolyte membrane fuel cells (PEMFCs), due to heterogeneous local conditions, material inhomogeneity, and uneven flow distribution across the single cell active area and in between the individual cells. The impact of the load level and air feed conditions on the performance was identified for individual single cells within a 10‐cell stack. Analysis of the current density...
-
Communication Model Order Reduction in Hybrid Methods Involving Generalized Impedance Matrix
PublicationA novel strategy for the efficient analysis of frequency-domain scattering electromagnetic problems in open and closed domains is presented. A fully automatic model-order reduction technique, called the enhanced reduced-basis method, is applied to increase the efficiency of the hybrid approach, which combines the finite-element and mode-matching methods. Numerical tests show that the proposed algorithm yields reliable and highly...
-
Electrochemical Evaluation of Sustainable Corrosion Inhibitors via Dynamic Electrochemical Impedance Spectroscopy
PublicationFinding suitable measurement methods for the effective management of electrochemical problems is of paramount importance, particularly for improving efficiency in corrosion protection. The need for accurate measurement techniques specific to nonstationary conditions has long been recognized, and promising approaches have emerged. This chapter introduces dynamic electrochemical impedance spectroscopy as a novel advancement in electrochemistry...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Comparison of corrosion resistance of al-alloys by means of dynamic electrochemical impedance spectroscopy
PublicationPrzeprowadzono badania metodą dynamicznej elektrochemicznej spektroskopii impedancyjne stopów 1100 i 5162. Zaproponowano zastępcze modele elektryczne opisujące zachowanie się stopów w warunkach ekspozycji w roztworach zawierających wysokie stężenie jonów chlorkowych. Wyznaczono zmiany podstawowych parametrów elektrycznych układów zastępczych od potencjału. Stwierdzono wyższą podatność na korozję stopu 5162 w porównaniu ze stopem...
-
Impedancja nerki. Biul. Oddz. Białost. SEP**2003 nr 16 s. 22-25, 4 rys. bibliogr. 3 poz.
PublicationPrzedstawiono istotę odwzorowania pracy nerki za pomocą obwodu elektrycc- nego. Podano zmiany przepływu krwi w przypadku zmian chorobowych w nerce.
-
Analiza procedur oceny uziemień odgromowych
PublicationW pracy dokonano prównania różnych metod wyznaczania parametrów uziemień odgromowych na tle obowiązujących przepisów. Porównano metody wyznaczania rezystancji statycznej i udarowej oraz impedancji uziemień w szerokim zakresie częstotliwości. Sformułowano wnioski dotyczące zasadności doboru odpowiednich metod pomiarowych do kontroli uziemień o różnej konstrukcji i różnym przeznaczeniu.
-
Mikroprocesorowy miernik impedancji pętli zwarciowej eliminujący wpływ odkształcenia napięcia przez regulację argumentu obciążenia pomiarowego
PublicationW artykule przedstawiono problematykę pomiaru impedancji pętli zwarciowej w sieciach o napięciu odkształconym. Zaproponowano metodę pomiaru impedancji pętli eliminującą wpływ odkształcenia napięcia i zbudowano mikroprocesorowy miernik, który ją wykorzystuje. W mierniku zastosowano impedancyjne obciążenie pomiarowe o stałej wartości modułu i regulowanym automatycznie argumencie. Przy zrównaniu argumentu impedancji obciążenia pomiarowego...
-
Analiza matematyczna modelu miernika do pomiaru impedancji pętli zwarciowej w sieci z obciążeniami roboczymi
PublicationPrzedstawiono matematyczny model miernika do pomiaru impedancji pętli zwarciowej w sieci z obciążeniami roboczymi oraz analizę dokładności pomiaru przeprowadzoną w oparciu o ten model. Przeprowadzone badania modelowe pozwalają stwierdzić, że metoda wektorowa umożliwia wystarczająco dokładny pomiar impedancji pętli zwarciowej oraz wyznaczenie jej składowych ortogonalnych, rezystancji i reaktancji.
-
Pomiar impedancji pętli zwarciowej w obwodach z RCD i w obwodach zasilanych z UPS
PublicationPrzedstawiono główne czynniki wpływające na dokładność pomiaru impedancji pętli zwarciowej w instalacjach niskiego napięcia. Omówiono problemy zbędnego wyzwalania wyłączników różnicowoprądowych podczas tego pomiaru, a także zwrócono uwagę na jego specyfikę w obwodach zasilanych z UPS.
-
Nowe metody pomiaru impedancji pętli zwarciowej dużym pełnofalowym prądem pomiarowym bez wyzwalania wyłączników różnicowoprądowych
PublicationWartość impedancji pętli zwarciowej charakteryzuje warunki zwarciowe i napięciowe w sieciach i instalacjach elektroenergetycznych. W artykule przedstawiono problematykę pomiaru impedancji pętli zwarciowej w instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi (RCD). Zaproponowano nową metodę pomiaru impedancji pętli bez wyzwalania RCD i wykonano dwie odmiany mierników, które ją wykorzystują. Pomiar nową metodą przeprowadza...
-
Wpływ wybranych błędów aparaturowych na dokładność pomiaru impedancji uziemienia w warunkach odkształcenia krzywej napięcia
PublicationW pracy omówiono wpływ wybranych błędów aparaturowych na dokładność pomiaru impedancji uziemień metodą techniczną oraz zaproponowaną nową metodą. Metoda ta pozwala ograniczyć wpływ odkształcenia napięcia sieci na błędy pomiaru impedancji. W badaniach skupiono się na błędzie wnoszonym przez przetwornik A/C, który może się znajdować w torach pomiarowych napięć i prądów obydwu metod. Badania i obliczenia błędów przeprowadzone zostały...
-
DEIS evaluation of the relative effective surface area of AISI 304 stainless steel dissolution process in conditions of intergranulatar corrosion
PublicationWyniki przedstawione w tej pracy stanowią dalszą część badań dotyczących procesu roztwarzania wysokostopowej stali AISI 304 w warunkach zachodzenia korozji międzykrystalicznej z wykorzystaniem techniki dynamicznej elektrochemicznej spektroskopii impedancyjnej (DEIS). Po raz pierwszy zaprezentowano zmiany względnej powierzchni efektywnej procesu roztwarzania stali AISI 304 w warunkach zachodzenia korozji międzykrystalicznej w funkcji...
-
Localized impedance measurements of AA2024 and AA2024‐T3 performed by means of AFM in contact mode
Publication -
Implementation and Validation of Multisinusoidal, Fast Impedance Measurements in Atomic Force Microscope Contact Mode
Publication -
Corrosion resistance evaluation of Al‐based alloys by means of dynamic electrochemical impedance spectroscopy
Publication -
Application of electrochemical impedance spectroscopy to monitoring discharging process of nickel/metal hydride battery
Publication -
Use of Impedance Spectroscopy to Characterize Lining Performance in Simulated Flue Gas Desulfurization Systems
Publication -
Instantaneous impedance evaluation of dissolution of aisi 304 stainless steel during intergranular corrosion
PublicationCelem pracy było uzyskanie informacji dotyczących zróżnicowania parametrów elektrycznych uzyskanych na podstawie zarejestrowanych chwilowych widm impedancyjnych w zakresie aktywacji i reaktywacji roztwarzania wysokostopowej stali austenitycznej AISI podczas postępującego procesu korozji międzykrystalicznej. Badania prowadzono z wykorzystaniem dynamicznej elektrochemicznej spektroskopii impedancyjnej (DEIS). Pomiary wykonywano ''on-line''...
-
Performance analysis of power swing blocking feature in ABB 670 series impedance relays
PublicationThis paper presents test results of a distance protection’s PSD power swing detection feature in ABB 670 series relays. A RED670 relay was tested, which is part of the hydroelectric set protection in Żarnowiec Pumped Storage Plant. The power swing blocking feature’s performance was analysed on the basis of the results of object tests made with an Omicron digital tester. Also presented are simulation results that illustrate the...
-
Localized impedance measurements of AA2024 and AA2024-T3 performed by means of AFM in contact mode
PublicationPurpose: The purpose of this paper is to present the results of an atomic force microscopy (AFM) based approach to local impedance spectroscopy (LIS) measurement performed on AA2024 and AA2024-T3 aluminium alloys. Design/methodology/approach: AFM-LIS measurements were performed ex-situ without the electrolyte environment, so in fact the electrical not electrochemical impedance was obtained. Findings: Relative local impedance values...
-
Impedance of cation-coupled electron transfer reaction: Theoretical description of one pathway process
PublicationIt has been assumed that cation electron coupled charge transfer can be conducted in accordance with two mutually coupled reactions. Using a differential method an expression was introduced which describes the impedance of a cation electron coupled transfer reaction. Also, an electrical equivalent circuit has been defined. The total faradaic impedance is the sum of electron transfer impedance and cation transfer impedance. Issues...
-
Application of electrochemical impedance spectroscopy to monitoring discharging process of nickel/metal hydride battery.
PublicationThis paper presents the possibility of applying impedance analysis to cell diagnostics. In order to obtain characteristic curves of both electrodes of a NiMH battery simultaneously, a reference electrode was added into the circuit. The authors analysed the cell under three cases, i.e. when its properties are determined only by the state of the positive electrode, only by the state of the negative electrode, or when both electrodes...
-
Implementation and Validation of Multisinusoidal, Fast Impedance Measurements in Atomic Force Microscope Contact Mode.
PublicationThis study presents a novel approach to impedance measurements. The methodology discussed is limited to contact in the sample-probe system under ambient conditions without the presence of electrolyte. Comparison with results of direct and alternating current measurements for well-defined metallic surfaces are made. In spite of idealization related to the type of contact examined, the proposed technique provides an improvement of...
-
Multivariate analysis of impedance data obtained for coating systems of varying thickness applied on steel
PublicationElectrochemical impedance spectroscopy (EIS) has proven to be a valuable test method for the electrochemical characterization of protective coatings on metals. The common way of analysis in impedance spectroscopy is to model the impedance spectrum by means of an equivalent circuit and to extract the quantity of interest using optimization techniques. A model, corresponding to the behavior of the sample under testing, is important...
-
Nonlinear Impedance as Possible Result of Ion-Polaron Interaction in Cu2O-Al2O3-SiO2 Glass
PublicationNonlinear a.c. impedance measurements were performed in Cu2O-Al2O3-SiO2 glass in wide frequency range. The obtained results shows that a large nonlinearity in the impedance signal is observed at moderate electric fields of an order 1V/mm. The contents of the third harmonics reaches about 10% and strongly depends on temperature and frequency. The investigated glass exhibits mixed electronic-ionic conductivity. Electronic conduction...
-
Linear and nonlinear impedance in iron oxide glasses containing alkaline ions and alkali free
PublicationThe linear and nonlinear impedance spectra of oxide glasses were measured in the frequency range of 1 mHz to 1 MHz and in the temperature range of 153K to 483K. Two groups of iron oxide glass samples were prepared, the first one containing alkaline ions and the second one without alkali. In the first group, compositions of glasses were as follows: (in %mol) 50% SiO2 , 25% PbO, 15% Fe2O3 and 15% one of alkaline oxides: Na2O, K2O,...
-
Cyclic analysis of thermal impedance of a passive layer of aluminium in a neutral borate buffer solution
PublicationW pracy przedstawiono wyniki badań warstwy pasywnej tworzącej się na stopie 1050 A w warunkach zmieniającej się temperatury. Zmiany realizowano w sposób cykliczny zwiększając a następnie zmniejszając temperaturę. W czasie zmian temperatury prowadzono badania metodę dynamicznej elektrochemicznej spektroskopii impedancyjnej. Stwierdzono największe zmiany parametrów elektrycznego schematu zastępczego w czasie pierwszego cyklu zmian....
-
Corrosion resistance evaluation of Al-based alloys by means of dynamic electrochemical impedance spectroscopy
PublicationW pracy przedstawiono wyniki badań stopów aluminium wykonane za pomocą dynamicznej elektrochemicznej spektroskopii. Na podstawie uzyskanych widm impedancyjnych zostały pokazane zmiany parametrów elektrycznego schematu zastępczego z potencjałem. Stwierdzono, że dodatek magnezu do badanego stopu obniża właściwości przeciwkorozyjne stopu.
-
Multispectral impedance quality testing of coil-coating system using principal component analysis
PublicationThe task of quality checking of the coil-coated system was undertaken using impedance spectroscopy. In order to properly characterize the system the new impedance spectrum was calculated as an averaged result of 12 experimental spectra obtained from 12 different places of the sample at the same time of immersion in 3% of NaCl. The experimental spectra were recorded for a 24-h period at 1 h intervals between starting points of each...
-
Application of the short time Fourier transformation to the continuous frequency method of measurement of electrode impedance
PublicationPrzedstawiona została nowa metoda pomiaru impedancji elektrodowej. Wykorzystuje ona jako pobudzenie niestacjonarny sygnał napięciowy, którego częstotliwość jest liniową funkcją czasu. Zastosowanie transformacji STFT do analizy napięciowego sygnału pobudzenia i odpowiedzi prądowej umożliwia wyznaczenie widma impedancyjnego. Dokładność otrzymywanych wartości impedancji uwarunkowana jest wielkością okna i zastosowanej funkcji analizującej.
-
Evaluating the performance of organic coatings under mechanical stress using electrochemical impedance spectroscopy
PublicationMimo, iż znaczna liczba konstrukcji zabezpieczanych przy pomocy powłok poddawana jest cyklicznym naprężeniom mechanicznym, czynnik ten wydaje się być niedoceniany jako przyczyniający się do przyspieszonego niszczenia organicznych układów powłokowych. Celem pracy było zweryfikowanie czy powtarzające się naprężenia mechaniczne stanowią istotny element wpływający na skrócenie czasu eksploatacji systemów powłokowych. W tym celu układ:...
-
Dynamic impedance measurements of the Direct Methanol Fuel Cell cathode at various operating temperatures
PublicationThis article discusses the application of impedance analysis for diagnosing the cathode of a direct methanol fuel cell at various operating temperatures. The Dynamic Electrochemical Impedance Spectroscopy technique coupled with a linear current scan was applied for this purpose. This technique allowed the observation of changes in the cathode's properties in the fuel cell operating under real working conditions. An equivalent model...
-
Three modes of electrochemical impedance spectroscopy measurements performed on vanadium redox flow battery
PublicationThis article presents an innovative approach to monitor working redox flow batteries using dynamic electrochemical impedance spectroscopy, diverging from the commonly sequential impedance methods carried out under potentiostatic or galvanostatic conditions close to the open circle voltage. The authors introduce a fresh variation of dynamic impedance measurement that leverages an amplitude-modulated multi-frequency alternating current...
-
Application of quartz crystal microbalance and dynamic impedance spectroscopy to the study of copper corrosion inhibitors
PublicationThe study investigates the application of Dynamic Electrochemical Impedance Spectroscopy (DEIS) and Electrochemical Quartz Crystal Microbalance (EQCM) techniques to examine the corrosion inhibition of copper by Benzotriazole and Sodium Folate in a 0.1 M NaCl solution. DEIS, an advanced version of Electrochemical Impedance Spectroscopy (EIS), allows for real-time monitoring of non-stationary electrochemical systems,...
-
The Application of Dynamic Electrochemical Impedance Spectroscopy (DEIS) Technique in Corrosion and Corrosion Inhibition Studies
Publicationorrosion studies have attracted considerable interest in the areas of materials chemistry and industrial chemistry, as it affects the direct and indirect costs of industry, leading to huge economic setbacks due to the need for repair, maintenance, and even shutdowns due corrosion damage. This new volume is a comprehensive resource that presents new and up-to-date, theoretical, and experimental corrosion inhibition studies.
-
Application of galvanodynamic impedance spectroscopy for studying passive film cracking under mechanical strain
PublicationThe paper reports the results of simultaneous mechanical and electrochemical investigations on austenitic (18/8) stainless steel in a 2 % solution of sulphuric acid. The measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Electrochemical analysis of mechanical passive layer cracking and repassivation conditions during a tensile test was carried out. Application of this methodology allowed...
-
Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset
PublicationThe dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.
-
Polymer membranes loaded with lipids for taste sensing: electrochemical impedance spedance spectroscopy studies
PublicationZcharakteryzowano metodą impedancyjnej spektroskopii elektrochemicznej membrany polichlorku winilu z lipidami zanurzone w roztworze kwasu cytrynowego. Badano membrany elektrod dodatnio naładowanych (heksadecyloamina, chlorek, benzyloheksadecylodimetyloamoniowy) i ujemne naładowanych (kwas elaidynowy, cholesterol, l-dodekonol). Badania impedacyjne pozwoliły na rozróznienie czterech stałych czasowych: rezystancja wysokiej częstotliwości,...
-
Method using bilinear transformation for measurement of impedance parameters of a multielement two-terminal network
PublicationArtykuł przedstawia metodę identyfikacji parametrów impedancyjnych obiektów modelowanych dwójnikami. Metoda wykorzystuje właściwości przekształcenia biliniowego pozwalającego na przedstawienie impedancji obiektu jako funkcji każdego z parametrów obwodu zastępczego z osobna. Odwrotne przekształcenie biliniowe pozwala na wyznaczenie wartości każdego parametru na podstawie pomiaru impedancji na jednej częstotliwości dobranej dla...
-
Impedance monitoring of corrosion degradation of plasma electrolytic oxidation coatings (PEO) on magnesium alloy
PublicationImpedance technique based on continuous multisinusoidal current perturbation was used to explain degradation process of plasma electrolytic oxidation coatings (PEO) on magnesium alloy. An obtained impedance spectrum was fitted by electrical equivalent circuit to describe properties of conversion layer on magnesium alloy. Additionally, galvanostatic mode maintained during experiment, with DC current equal to zero, allowed to achieve...
-
Evaluation of organic coating systems for corrosion protection of industrial equipment using impedance spectroscopy
PublicationThe high economic impact of corrosion can be reduced by enhanced corrosion management and prevention based on appropriate means. This applies in particular to the protection of structures with organic protective coatings. Steel is subject to corrosion that reduces its service life and leads to destruction in most severe cases. The application of paints to metallic objects for corrosion control has been known for a long time and...