Filtry
wszystkich: 10666
wybranych: 1047
-
Katalog
- Publikacje 9367 wyników po odfiltrowaniu
- Czasopisma 52 wyników po odfiltrowaniu
- Konferencje 19 wyników po odfiltrowaniu
- Osoby 101 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Kursy Online 55 wyników po odfiltrowaniu
- Wydarzenia 8 wyników po odfiltrowaniu
- Dane Badawcze 1062 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: CAMERA-BASED TRACKING
-
Measurements of reactive power distribution in a ship power station with two generators working in parallel
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing a reactive...
-
The luminescence study of CsPbI3 nanoparticles embedded in Cs4PbI6 crystals.
Dane BadawczeCs4PbI6, as a rarely investigated member of the Cs4PbX6 (X is a halogen element) family, has been successfully synthesized atlow temperatures by collaborators from National Taiwan University. Strong red to near-infrared (NIR) emission properties have been detected, and its optical emission centers have been identified to be numerous embedded perovskite-type...
-
Individual investors willingnes to invest in ESG in Poland survey results
Dane BadawczeThis dataset encompasses Polish citizens, including those being retail investors, attitude toward climate change and ESG investment. Dataset of two waves of the omnibus survey which provides representative database for Poland for February 2021. A specialized polling institute, was subcontracted to conduct the survey using Computer-Assisted Web Interviewing...
-
Radiation pattern measurements of geometrically small antennas performed in non-anechoic environments
Dane BadawczeThe dataset contains unprocessed measurements of radiation pattern characteristics performed in non-anechoic regime for three geometrically small antenna structures: a spline-parameterized Vivaldi structure, a compact spline-based monopole, and a quasi-Yagi geometry with enhanced bandwidth. The responses have been obtained over broad frequency ranges...
-
Measurements of electrically small antenna radiation patterns in non-anechoic environments using TGM
Dane BadawczeThe dataset contains raw and processed measurements of radiation pattern characteristics performed in non-anechoic regime for four antenna structures: a spline-parameterized Vivaldi structure, a compact spline-based monopole, super-ultrawideband antenna, and a quasi-Yagi component. The responses have been obtained at the selected frequencies of interest...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Graphene oxide thin films deposited on a PCB board - chemical analysis
Dane BadawczeGraphene oxides based films were measured by X-ray photoemission spectroscopy (XPS) method. TheXPS measurements were carried out with the Omicron NanoTechnology UHV equipment. The hemispherical spectrophotometer was equipped with a 128-channel collector. The XPS measurements were performed at room temperature at a pressure below 1.1 × 10−8 mBar. The...
-
X-Ray photoemission spectroscopy measurements of the Nb-V-Sr-O ceramics
Dane BadawczeNiobium doped strontium vanadate based perovskite SrV1-xNbxO3-δ materials were prepared via conventional solid state reaction (SSR) method. For comparison, different samples with a various amount of niobium dopant in the structure were synthesized; x = 0; 0,2; 0,5; 0,8 and 1. Samples were sintered by two-steps: first under a pure hydrogen (purity >99.999%)...
-
Silicon microcantilever with impedance sensor
Dane BadawczeThe issue of microelectromechanical systems (MEMS) [1] has been enjoying popularity and interest since the 90s of the 20th century. Microcells are one of the simplest devices of this type, but they can be widely used in sensors. There are reports on the possibility of using this type of sensors in the context of such important issues as diagnostics...
-
Miscanthus × giganteus root anatomical traits measurements
Dane BadawczeThis data set presents the optical microscope measurements/ images of Miscanthus × giganteus (M×g) roots. The experiment was performed under work package 1: "Properties characterisation of two types of biochar", task D_RT: Phyto-analyses (stress response of plants on biochar amendments) in cooperation with Aarhus University. A short term pot experiment...
-
Topography of iron-phosphate glasses doped with niobium and titanium tested by confocal microscope
Dane BadawczeThe topography of phosphate-iron glasses containing niobium and titanium were investigated with the use of confocal miscroscope. Glass samples of the composition of 35P2O5-30Fe2O3-35Nb2O5, 35P2O5-30Fe2O3-27.5Nb2O5-7.5TiO2 and 35P2O5-30Fe2O3-20Nb2O5-15TiO2 (in %mol) were prepared by the conventional melt quenching technique. Appropriate amounts of reagents...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #2. Image period: 1 sec.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 1 sec (1 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #3. Image period: 0,5 sec.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 0,5 sec (2 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #2. Image period: 0,5 sec.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 0,5 sec (2 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #3. Image period: 1 sec.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 1 sec (1 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
How personality traits, sports anxiety, and general imagery could influence the physiological response measured by SCL to imagined situations in sports?
Dane BadawczeThe data were collected to understand how individual differences in personality (e.g. neuroticism), general imagery, and situational sports anxiety are linked to arousal measuring with skin conductance level (SCL) in situational imagery (as scripted for sport-related scenes). Thirty persons participated in the study, aged between 14 and 42 years, with...
-
Calculations of material factors for a set of 20 thermistors
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Calculations of the resistance values of 10 ratio resistors
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Hydrodynamic reanalysis of water temperature and salinity in the Baltic Sea using the PM3D model
Dane BadawczeThe dataset contains the results of numerical modeling of water temperature and salinity in the Baltic Sea since 1998. A long-term reanalysis was performed using the three-dimensional hydrodynamic model PM3D (Kowalewski and Kowalewska-Kalkowska, 2017), a new version of the M3D model (Kowalewski, 1997). A numerical dynamic-thermodynamic model of sea...
-
Video traffic data - Interchanges Grota Roweckiego (S86 - Grota Roweckiego)
Dane BadawczeThe data includes video traffic data registered with 2 video cameras at entry and exit lanes of the Grota Roweckiego interchange within S86 expressway in Poland (interchange of expressway S86 and Grota Roweckiego street), located in the Silesia Agglomeration. The data covers the one days: 23.05.2017 (expressway S86). The video cameras installed on the...
-
The luminescence study of Sr2−xSrxPN3:Eu2+ nitridophosphate.
Dane BadawczeIn this work, a series of Ca2−xSrxPN3:Eu2+ nitridophosphate phosphors through a solid-solution strategy involving a hot isostatic press was developed by collaborators from National Taiwan University. Unexpected dual emissions in the red and infrared regions are observed, different from previous research results. The unique change in red and near-infrared...
-
Testing of DES toxicity towards Candida subhashii
Dane BadawczeDataset presents results of testing toxicity of selected DES solutions in mineral salt medium towards Candida subhashii.
-
X-ray images of Baltic herring. Data analysis
Dane BadawczeBased on the developed methodology for the: (i) optimal method of catching, (ii) transporting and storing fish, (iii) measuring and (iv) analyzing X-rays images, the existing collection of X-ray images of Baltic herring, caught in October 2002 during the Swedish component of the Baltic International Acoustic Survey (BIAS) in the Baltic proper (ICES...
-
The XRD diffraction patterns of (La0.3Sr0.6Ce0.1)0.9FexTi(1-x)O3-δ (x=0.1, 0.2 and 0.3) materials after reduction at 900 deg.C in hydrogen
Dane BadawczeThe (La0.3Sr0.6Ce0.1)0.9FexTi(1-x)O3-δ (x=0.1, 0.2 and 0.3) materials were synthesized via the Pechini method. First, the reagents in the form of nitrates were weighed and dissolved in DI water. In another beaker, a stoichiometric amount of titanium (IV) butoxide (Ti(OBu)4) was mixed together with reagent-grade ethylene glycol (EG), and citric acid...
-
SEM/EDX data of (Cr,Fe,Mn,Co,Ni)3O4 High-entropy spinel oxide thin films deposited on amorphous SiO2 substrate by spray pyrolysis techniqe
Dane BadawczeThis Data set include SEM and EDX results of (Mn,Co,Fe,Ni,Cr)3O4 high-entropy spinel oxide prepared in the form of a ~ 500 nm thin film utilising a facile spray pyrolysis technique. The structural and electrical properties of the layers were characterised after exposure to temperatures in the range of 400–900 ◦C. The as-deposited layers were amorphous,...
-
TEM data of (Cr,Fe,Mn,Co,Ni)3O4 High-entropy spinel oxide thin films deposited on amorphous SiO2 substrate by spray pyrolysis techniqe
Dane BadawczeThis Dataset include presentation of summarized TEM investigation of (Mn,Co,Fe,Ni,Cr)3O4 high-entropy spinel oxide prepared in the form of a ~ 500 nm thin film utilising a facile spray pyrolysis technique. The structural and electrical properties of the layers were characterised after exposure to temperatures in the range of 400–900 ◦C. The as-deposited...
-
Calculations of the resistance values of 20 thermistors at 100°C
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Acoustic emission signals in concrete beams under 3-point bending (plain concrete, steel fibre reinforced concrete, steel bar reinforced concrete)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of concrete beams with dimensions 40 x 40 x 160 cm3under the 3-point bending. Two concrete mixes, both based on the same design, were produced in the test programme. Mixture #1 was the plain concrete (PC), consisting of cement CEM I 42.5R (380 kg/m3), water (165 kg/m3), aggregate 0/2 mm (648...
-
Calculations of the resistance values of 20 thermistors at 50°C
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Straszyn 2018 - video data
Dane BadawczeStraszyn 2018 - video data
-
Calibration images under different lighting conditions vol. 2
Dane BadawczeDataset description: Calibration images under different lighting conditions vol. 1
-
Transmission electron microscope (TEM) and optical microscope images of pristine and silica-coated bismuth oxide and gadolinium oxide particles
Dane BadawczeCollection of raw transmission electron microscope (TEM) micrographs and optical microscope images used in the associated manuscript. All data in accessible *.tif format. Zip package contains:
-
Calibration images under different lighting conditions - static for feature localisation
Dane BadawczeDataset description: Calibration images under different lighting conditions - static mode for feature detection
-
The American Sign Language alphabet
Dane BadawczeThe American Sign Language dataset contains all static letters of the American alphabet, meaning those that do not require movement to perform (the entire alphabet except for the letters 'J' and 'Z', which are dynamic and require hand movement).
-
Potential diagnostic utility of recombinant Toxoplasma gondii proteins for detecting anti-Toxoplasma gondii IgG antibodies in horses serum samples
Dane BadawczeToxoplasmosis is caused by an intracellular protozoan, Toxoplasma gondii, and is a parasitic disease that occurs in all warm-blooded animals, including humans. Toxoplasmosis is one of the most common parasitic diseases of animals and results in reproductive losses. Diagnosis of toxoplasmosis is currently based on serological assays using native antigens...
-
Potential diagnostic utility of recombinant Toxoplasma gondii proteins for detecting anti-Toxoplasma gondii IgG antibodies in goat serum samples
Dane BadawczeToxoplasmosis is caused by an intracellular protozoan, Toxoplasma gondii, and is a parasitic disease that occurs in all warm-blooded animals, including humans. Toxoplasmosis is one of the most common parasitic diseases of animals and results in reproductive losses. Diagnosis of toxoplasmosis is currently based on serological assays using native antigens...
-
The mechanism of internalization study of QDgreen−CD−FA−C−2028 conjugate at IC80 value to cancer (H460, Du-145, and LNCaP) and normal (MRC-5 and PNT1A) cells
Dane BadawczeThe influence of different endocytosis inhibitors on the internalization of QDgreen−CD−FA−C−2028 conjugate at IC80 value in cancer (H460, Du-145, and LNCaP) and normal (MRC-5 and PNT1A) cells. First, the cells were preincubated with: drug-free medium (no inhibitor), at 4 °C, 5 µM Cytochalasin D, 30 µM Amiloride, 80 µM Dynasore, 25 µM Pitstop 2 and 1.5...
-
Potential diagnostic utility of recombinant Toxoplasma gondii proteins for detecting anti-Toxoplasma gondii IgG antibodies in feline serum samples
Dane BadawczeToxoplasmosis is caused by an intracellular protozoan, Toxoplasma gondii, and is a parasitic disease that occurs in all warm-blooded animals, including humans. Toxoplasmosis is one of the most common parasitic diseases of animals and results in reproductive losses. Diagnosis of toxoplasmosis is currently based on serological assays using native antigens...
-
Cytotoxicity of chitosan hydrogels aginst L929 cells
Dane BadawczeThis study presents absorbance values of formazan product (converted from MTT) which corresponds to the cytotoxicity of chitosan compounds (dissolved in carbonic acid, dissolved in carbonic acid endotoxin free, and dissolved in hydroxyacetic acid) aginst adult mouse fibroblast L929 cells. The experiments were carried out according to the ISO 10993-5:2009(E)...
-
The database of odd algebraic periods for quasi-unipotent self-maps of a space having the same homology group as the connected sum of g tori
Dane BadawczeThe dataset consists of 20 files indexed by numbers g=1,...,20. Each file provides sets of odd algebraic periods for all quasi-unipotent self-maps of a space having the same homology groups as the connected sum of g tori. Let us remark that each data set covers all algebraical restrictions that come from zeta functions for the sets of minimal Lefschetz...
-
Mechanical lithography in a polymer substrate using AFM in contact mode
Dane BadawczeMechanical lithography in a polymer substrate. Contact mode. NTEGRA Prima (NT-MDT) device. NSG 01 probe.
-
Effect of antitumor compounds on the yeast topoisomerase II relaxation activity
Dane BadawczeThe datasets contain results of antitumor compounds* (known inhibitors of human topoisomerase alpha II) inhibitory activity against yeast topoisomerase II. DNA topoisomerases (Topo) are enzymes that catalyze changes in the spatial structure of DNA and play an important role in replication, transcription and recombination. Beyond their normal functions,...
-
Influence of the annealing condictions on the chemical structure of LaBaGdCo ceramics
Dane BadawczeCeramic samples based on Barium, Lanthanum, Gadolinium and Cobaltium were produced by solid state reaction. After sintring in a furnance, samples were annealed at 300 Celsius degree in wet and dry atmosphere. Annealing takes 72h or 2h. Results of annealing were observed by X-Ray photoemission spectroscopy (XPS), OmicronNanotechnology. XPS analysis...
-
Total electrical conductivity data of (Cr,Fe,Mn,Co,Ni)3O4 High-entropy spinel oxide thin films deposited on amorphous SiO2 substrate by spray pyrolysis techniqe
Dane BadawczeThis dataset includes electrical conductivity measurements results measured by van der pauw technique up to 900oC.
-
Calculations of the resistance values of 20 thermistors at 0°C
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Instantaneous power signal measurements for bearing diagnostics
Dane BadawczeBearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous current and voltage power supplied to the engines. Bearing damage causes the appearance of deformations, which are in the form of additional harmonic components...
-
Analysis of the instantaneous power signal for bearing diagnostics -bearing damaged
Dane BadawczeThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of a damaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...