Filtry
wszystkich: 221
wybranych: 195
-
Katalog
Filtry wybranego katalogu
Wyniki wyszukiwania dla: CONTROL LOOP
-
A new approach to active noise and vibration control - [Part I: the known frequency case]
PublikacjaThis paper presents a new approach to rejection of complex-valued sinusoidal disturbances acting at the output of a discrete-time stable linear plant with unknown dynamics. It is assumed that the frequency of the sinusoidal disturbance is known, and that the output signal is contaminated with wideband measurement noise. The disturbance rejection control rule is first derived and analyzed for a nominal plant model, different from...
-
Proportional-Derivative and Model-Based Controllers for Control of a Variable Mass Manipulator
PublikacjaIn the paper, numerical analysis of dynamics of a variable mass manipulator is presented. A revolute joints composed manipulator is considered. Payload of the gripper is considered as the only element characterized by unknown value of its mass (variable between subsequent operations). As in other cases of the revolute joints composed manipulators, its behaviour dependents significantly on the pose of the manipulator. When the manipulator...
-
Design of optimal state feedback controller with observer for multidimensional electrical system
PublikacjaFrom the control point of view, two-input-two-output RC electrical system is a linear and multidimensional system. In this paper, integral control and closed-loop observer are verified whether they can be used and designed. To verify this, Kalman tests are made. These structures are presented and discussed. Integral Control is tested with some base disturbances impact and checked whether it can handle them. The estimated values...
-
Implementation of the FOPID Algorithm in the PLC Controller - PWR Thermal Power Control Case Study
PublikacjaIn the paper authors describe proposition of design and verification procedures of the discrete Fractional Order PID (FOPID) algorithm for control of the Pressurized Water Reactor (PWR) thermal power near its nominal operating point. The FOPID algorithm synthesis consists of: off-line optimal tunning of its parameters in continuous time-domain with LQ (Linear Quadratic) performance index and simplified models of nuclear reactor...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublikacjaMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Prototype and design of six axis robotic manipulator
PublikacjaThe paper presents a design of six axis manipulator. The design consists of specially designed solutions for housing, planetary gearboxes and electronics. The manipulator is controlled by a supervisory control system. The use of a series of measuring elements allows to track the current position of each axis and use this to create a cascade control loop with velocity and acceleration feed-forward. The implemented control algorithm...
-
Measurement of the earth fault loop impedance in a low voltage network with operating loads
PublikacjaW artykule przedstawiono problematykę dokładności pomiaru impedancji pętli zwarciowej w sieciach z obciążeniami roboczymi. Klasyczne metody pomiarowe i mierniki mogą powodować błędy pomiaru przekraczające dopuszczalną wartość. Z tego powodu może wystąpić ryzyko porażenia prądem elektrycznym, ponieważ przy doziemieniu nie będzie spełniony warunek samoczynnego wyłączenia zasilania. Błędy pomiaru w sieci z obciążeniami roboczymi można...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublikacjaW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
Challenges in operating and testing loop heat pipes in 500–700 K temperature ranges
PublikacjaThe potential applications of loop heat pipes (LHPs) are the nuclear power space systems, fuel cell thermal management systems, waste heat recovery systems, medium temperature electronic systems, medium temperature military systems, among others. Such applications usually operate in temperature ranges between 500–700 K, hence it is necessary to develop an LHP system that will meet this requirement. Such a thermal management device...
-
Skalowalne modele fizyczne wybranych typów siłowni wiatrowych w technologii hardware-in-the-loop
PublikacjaCelem niniejszej rozprawy jest opracowanie adekwatnego programowalnego modelu fizycznego siłowni wiatrowej wykorzystującego urządzenia elektryczne oraz model przetwarzania energii kinetycznej wiatru na energię mechaniczną ruchu obrotowego wirnika generatora. Zaproponowany przez autora model sterowany jest przez regulator prędkości, bazujący jedynie na pomiarach prędkości obrotowej oraz momentu elektromagnetycznego. Monografia stanowi...
-
Speed sensorless asynchronous motor drive with inverter output lc filter
PublikacjaIn this paper a speed sensorless ac drive with inverter and output LC filter is proposed. A nonlinear, decoupled field oriented control algorithm with a flux and speed close-loop observer is used. In spite of using LC filter on the inverter output, the sensorless system works precisely. That result are obtained as a result of the appropriate estimation and control system use. The theory, simulation, and experimental results are...
-
Multichannel self-optimizing narrowband interference canceller
PublikacjaThe problem of cancellation of a nonstationary sinusoidal interference, acting at the output of an unknown multivariable linear stable plant, is considered. No reference signal is assumed to be available. The proposed feedback controller is a nontrivial extension of the SONIC (self-optimizing narrowband interference canceller) algorithm, developed earlier for single-input, single-output plants. The algorithm consists of two loops:...
-
Active Control of Highly Autocorrelated Machinery Noise in Multivariate Nonminimum Phase Systems
PublikacjaIn this paper, a novel multivariate active noise control scheme, designed to attenuate disturbances with high autocorrelation characteristics and preserve background signals, is proposed. The algorithm belongs to the class of feedback controllers and, unlike the popular feedforward FX-LMS approach, does not require availability of a reference signal. The proposed approach draws its inspiration from the iterative learning control...
-
Experimental study of pressure rise at the evaporator of capillary pumped loop with acetone and water as working fluids
PublikacjaIn this work studied is the possibility of fluid pumping using capillary forces in the capillary pumped loop. Experimental and theoretical studies have been performed to understand the phenomena associated with heat transfer in porous structure of the evaporator. The capillary effect was studied during operation of two different capillary porous structures with two different working fluids, namely water and acetone. The results...
-
Capillary pumped loop as a tool for collecting large heat fluxes from electronic devices on warships
PublikacjaThe combat potential of future warships will be directly related to the use of modern electronic devices being parts of advanced systems, such as, for instance, radar systems, fire aiming systems, fire detection systems, electric drive systems, and even electronic and radio-electronic weaponry, railguns and lasers, installed on these warships. The capacity and functionality of these devices is continually increasing, at decreasing...
-
Miniaturized Dual-Band SIW-Based Bandpass Filters Using Open-Loop Ring Resonators
PublikacjaThis article presents two novel architectures of dual-band substrate integrated waveguide (SIW) bandpass filters (BPFs). Initially, two identical open-loop ring resonators (OLRRs) are coupled face-to-face on the top of the SIW cavity to realize a dual-band single-pole BPF. To obtain two-pole dual-band characteristics, two OLRRs resonant units are assembled horizontally within the top metal layer of the SIW, which is a technique...
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublikacjaA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
Power Hardware In-the-Loop validation of DC-DC power converter for offshore wind energy
Publikacja -
The role of the LB structural loop and its interactions with the PDZ domain of the human HtrA3 protease
Publikacja -
The LA Loop as an Important Regulatory Element of the HtrA (DegP) Protease from Escherichia coli
Publikacja -
Redundantly Actuated 3RRR Parallel Planar Manipulator - Numerical Analyses of its Dynamics Sensitivity on Modifications of its Platform’s Inertia Parameters
PublikacjaIn the paper, numerical analyses, as well as dynamics of a complex mechanism, are presented. Two objectives are crucial for the paper: inverse dynamic model is needed (dedicated to be use in the model predictive controller); an identification method is searched (some trajectory parameters are controlled, when specific trajectory is tracked under an open-loop model-based control), as selected parameters must be identified for the...
-
Dead time effects compensation strategy by third harmonic injection for a five-phase inverter
PublikacjaThis paper proposes a method for compensation of dead-time effects for a fivephase inverter. In the proposed method an additional control subsystem was added to the field-oriented control (FOC) scheme in the coordinate system mapped to the third harmonic. The additional control loop operates in the fixed, orthogonal reference frame ( α - β coordinates) without the need for additional Park transformations. The purpose of this method...
-
Closing the loop: Upcycling secondary waste materials into nanoarchitectured carbon composites for the electrochemical degradation of pharmaceuticals
PublikacjaIn this study, we demonstrated the application of electrochemical oxidation as a safer and cleaner technology for minimizing the impact of pharmaceuticals in wastewaters, simultaneously mediated by upcycled secondary waste materials (SWMs)-derived electrodes, to further reduce their environmental impact. The modularity, scalability, ease of operation and reliability make electrochemical oxidation an ideal process for the destruction...
-
Five-phase induction motor drive with sine-wave filter
PublikacjaThe paper presents closed loop ac drive with 5 phase induction motor operating with voltage source inverter and sine wave filter. The motor supply voltages and currents have sinusoidal shape. For well known adjustable electric drives the field oriented control method with flux and speed co ntrol can be applied. In the presence of output filter both control and estimation algorithms should be modified due to sine wave filter installation....
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublikacjaVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
The extracellular loop of Man-PTS subunit IID is responsible for the sensitivity of Lactococcus garvieae to garvicins A, B and C
Publikacja -
Multiple output differential OTA with linearizing bulk-driven active-error feedback loop for continuous-time filter applications
PublikacjaA CMOS circuit realization of a highly linear multiple-output differential operational transconductance amplifier (OTA) has been proposed. The presented approach exploits a differential pair as an input stage with both the gate and the bulk terminals as signal ports. For the proposed OTA, improved linearity is obtained by means of the active-error feedback loop operating at the bulk terminals of the input stage. SPICE simulations...
-
The Influence of Loop Heat Pipe Evaporator Porous Structure Parameters and Charge on Its Effectiveness for Ethanol and Water as Working Fluids
PublikacjaAbstract: This paper presents the results of experiments carried out on a specially designed experimental rig designed for the study of capillary pressure generated in the Loop Heat Pipe (LHP) evaporator. The commercially available porous structure made of sintered stainless steel constitutes the wick. Three different geometries of the porous wicks were tested, featuring the pore radius of 1, 3 and 7 um. Ethanol and water as two...
-
Preparation of Komagataeibacter xylinus Inoculum for Bacterial Cellulose Biosynthesis Using Magnetically Assisted External-Loop Airlift Bioreactor
Publikacja -
Deep analysis of Loop L1 HVRs1-4 region of the hexon gene of adenovirus field strains isolated in Poland
Publikacja -
Speed sensorless induction motor drive with predictive current controller
PublikacjaToday, speed sensorless modes of operation are becoming standard solutions in the area of electric drives. This paper presents a speed sensorless control system of an induction motor with a predictive current controller. A closed-loop estimation system with robustness against motor parameter variation is used for the control approach. The proposed algorithm has been implemented using field-programmable gate arrays (FPGAs) and a...
-
Predykcyjne sterowanie równoległym filtrem aktywnym ze sprzężeniem od prądu zasilającego
PublikacjaArtykuł przedstawia nowatorską strategię predykcyjnego sterowania równoległym energetycznym filtrem aktywnym (EFA). Proponowane sterowanie zawiera sprzężenie zwrotne od prądu zasilającego i wiąże zalety sterowania w układzie otwartym oraz zamkniętym – szybkość reakcji na zmianę prądu odbioru i bardzo wysoką skuteczność kompensacji. Wysoka jakość prądu kompensacyjnego wynika również z zastosowania w sterowaniu algorytmów predykcyjnych,...
-
Investigation of the electrochemical behaviour of AA1050 aluminium alloy in aqueous alkaline solutions using Dynamic Electrochemical Impedance Spectroscopy
PublikacjaThe paper presents the electrochemical behaviour of aluminium alloy AA1050 in aqueous alkaline media in the pH range 14–8.5. Electrochemical study was applied in order to obtain comprehensive information on the mechanism and kinetics of the process of anodic dissolution of aluminium, supplemented by monitoring of surface topography using an electron microscope. The corrosion rate of AA1050 increases with increasing concentration...
-
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublikacjaThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...
-
Merging extremum seeking and self-optimizing narrowband interference canceller - overdetermined case
PublikacjaActive cancellation systems rely on destructive interference to achieve rejection of unwanted disturbances entering the system of interest. Typical practical applications of this method employ a simple single input, single output arrangement. However, when a spatial wavefield (e.g. acoustic noise or vibration) needs to be controlled, multichannel active cancellation systems arise naturally. Among these, the so-called overdetermined...
-
Low cost set-up for supercapacitors parameters evaluation
PublikacjaWe propose a use of a power amplifier in the circuit of voltage to current converter (current driver) for supercapacitor charging/discharging in controlled conditions. The current driver is controlled by DAC output of DAQ board and voltage of DUT is measured and a control loop is realized by software. In the circuit the DC current method of evaluation of capacitance and equivalent series...
-
Brine Recycling from Industrial Textile Wastewater Treated by Ozone. By-Products Accumulation. Part 1: Multi Recycling Loop
Publikacja -
The LD loop as an important structural element required for transmission of the allosteric signal in the HtrA (DegP) protease from Escherichia coli
Publikacja -
Detection of specific UL49 sequences of Marek's disease virus CVI988/Rispens strain using loop-mediated isothermal amplification
Publikacja -
Programowo-sprzętowa platforma symulacyjna - Hardware In the Loop - zaawansowanego układu sterowania poziomem wody w pionowej wytwornicy pary elektrowni jądrowej
PublikacjaW artykule przedstawiono koncepcję programowo-sprzętowej platformy symulacyjnej wykorzystującej technikę symulacji w pętli sprzętowej HIL (ang. Hardware In The Loop simulation), wykorzystanej dla potrzeb projektowania i weryfikacji w czasie rzeczywistym (ang. Real Time) zaawansowanych algorytmów sterowania poziomem wody w pionowej wytwornicy pary elektrowni jądrowej. Jej głównymi elementami są: środowisko czasu rzeczywistego Matlab/Simulink...
-
Programowo-sprzętowa platforma symulacyjna - Hardware In the Loop - zaawansowanego układu sterowania poziomem wody w pionowej wytwornicy pary elektrowni jądrowej
PublikacjaW artykule przedstawiono koncepcję programowo-sprzętowej platformy symulacyjnej wykorzystującej technikę symulacji w pętli sprzętowej HIL (ang. Hardware In The Loop simulation), wykorzystanej dla potrzeb projektowania i weryfikacji w czasie rzeczywistym (ang. Real Time) zaawansowanych algorytmów sterowania poziomem wody w pionowej wytwornicy pary elektrowni jądrowej. Jej głównymi elementami sa: środowisko czasu rzeczywistego Matlab/Simulink...
-
Stable indirect adaptive control based on discrete-time T-S fuzzy model
PublikacjaThis paper presents an indirect adaptive fuzzy control scheme for uncertain nonlinear asymptotically stable plants.A discrete-time T-S fuzzy input-output model is employed to approximate the unknown plant dynamics. The T-S fuzzy model is fed with its own states, which are indeed its past outputs, rather than the measurements from the plants. Entirely based on this model, a feedback linearization control law is designed by using...
-
Stable indirect adaptive control based on discrete-time T-S fuzzy model
PublikacjaThis paper presents an indirect adaptive fuzzy control scheme for uncertain nonlinear asymptotically stable plants.A discrete-time T-S fuzzy input-output model is employed to approximate the unknown plant dynamics. The T-S fuzzy model is fed with its own states, which are indeed its past outputs, rather than the measurements from the plants. Entirely based on this model, a feedback linearization control law is designed by using...
-
Improvement of the Treatment of Loop Structures in the UNRES Force Field by Inclusion of Coupling between Backbone- and Side-Chain-Local Conformational States
Publikacja -
Five-phase squirrel-cage motor. Construction and drive properties
PublikacjaThis paper presents the simulation and experimental results of a five-phase squirrel-cage induction motor. The new machine has been designed to operate in a drive system with third harmonic rotor flux injection in order to improve the motor torque utilization. The motor structure, the mathematical model as well as the laboratory prototype have been described. The motor speed-torque characteristics and transients are elaborated...
-
Development of an emulation platform for synchronous machine power generation system using a nonlinear functional level model
PublikacjaThe article presents the Power Hardware in the Loop (PHIL) approach for an autonomous power system analysis based on the synchronous generator model incorporating magnetic saturation effects. The model was prepared in the MATLAB/Simulink environment and then compiled into the C language for the PHIL platform implementation. The 150 kVA bidirectional DC/AC commercial-grade converter was used to emulate the synchronous generator....
-
Design, Chemical Synthesis and Kinetic Studies of Trypsin Chromogenic Substrates Based on the Proteinase Binding Loop of Cucurbita maxima Trypsin Inhibitor (CMTI-III)
Publikacja -
Self-optimizing narrowband interference canceller - can reference signal help?
PublikacjaSONIC (Self-Optimizing Narrowband Interference Canceller) is an acronym of the recently proposed active noise control algorithm with interesting adaptivity and robustness properties. SONIC is a purely feedback controller, capable of rejecting nonstationary sinusoidal disturbances (with time-varying amplitudes and/or frequencies) in the presence of plant (secondary path) uncertainties. We show that even though SONIC can work reliably...
-
Fully Tunable Analog Biquadratic Filter for Low-Power Auditory Signal Processing in CMOS Technologies
PublikacjaA novel Gm-C structure of a second-order continuous-time filter is proposed that allows for the independent control of the filter’s natural frequency (ω0) and quality factor (Q). The structure consists of two capacitors and four transconductors. Two transconductors together with the capacitors form a lossless second-order circuit with tunable ω0. The other two transconductors form a variable gain amplifier (VGA) which realizes...