Time-current tripping curves of arc fault detection devices
PublikacjaTripping curves of arc fault detection devices, in accordance with PN-EN 62606 “General requirements for arc fault detection devices” have been presented in the paper. Consequently the most fundamental differences in arc fault detection devices tripping compared to circuit-breakers and residual current devices have been indicated.
-
Discrete measurement of fault-arc velocity
PublikacjaOpisano metodę dyskretnego pomiaru prędkości jednofazowego łuku awaryjnego poruszającego się w płaskim, poziomym układzie szyn. Badania przeprowadzono za pomocą punktowych czujników optycznych rozmieszczonych równomiernie wzdłuż szyn. Podano opis układu, jego charakterystykę, wpływ obszaru zjonizowanego na uzyskiwane wyniki i zależności między obserwowanymi wielkościami.
-
Mechanical Strength of MV Ship-switchgear During Fault Arc
PublikacjaIn the paper the analysis of pressure stressed in enclosure during fault arc inside switchgear is pre-sented as well. There is introduced the method based on determining stresses which are sum of tensile stresses (membrane) and deflection stresses. For tensile stresses nalysis the energy method, for unrestrainedly supported rectangular plate, was used. In the further part of the paper, the calculations and measurements results...
-
Results of investigations of the fault arc in L. V. Switchgears
PublikacjaOmówiono wyniki badań eksperymentalnych wyłączania 3 fazowych zwarć łukowych w rozdzielnicach niskonapięciowych za pomocą aparatów umieszczanych jedynie w środkowej fazie płaskiego układu szyn zbiorczych. ...
-
The measurement and calculation of gas temperature inside a switchgear during fault arc period.
PublikacjaW artykule przedstawiono metodę obliczania temperatury gazu wewnątrz rozdzielnicy szczelnej z izolacją powietrzną podczas zwarć łukowych w oparciu o równanie przewodnictwa cieplnego. Przedstawiono wyniki badań eksperymentalnych temperatury gazów podczas zwarć z łukiem wędrującym. Opisano model do badań, układ probierczy i warunki badań. Wyniki obliczeń porównano z wynikami badań eksperymentalnych.
-
Application of RCD and AFDD in low-voltage electrical installations for protection against fire
PublikacjaThe paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.
-
Dynamics of fault arc traveling along busbars in high voltage switchboards = Dynamika łuku zwarciowego przemieszczającego się wzdłuż szyn rozdziel-nic wysokiego napięcia
PublikacjaThe paper presents the results of magnetic induction and electrodynamic force calculations acting on arc column during short-circuit in medium voltage air-insulated bus-bars. The gap between the bars was 120 mm and the prospective short-circuit currents ranged from 4 kA to 8 kA. The paper also shows the measurement results of average velocity fault arc depending on currents arc diameter and arc current was established and described....
-
The effectivness of fault detection in common rail injectors examination methods
PublikacjaThe article presents the effectiveness tests of fault detection in common rail injectors. 40 injectors with different wear levels were tested. Testing was made on two test benches of a completely different design. Research includes comparison of accuracy, reproducibility and testability to detect specific defects. A device was created for visualization of the fuel injector spraying steam.
-
Using an IEEE1149.1 Test Bus for Fault Diagnosis of Analog Parts of Electronic Embedded Systems
PublikacjaThe new solution of a BIST called the JTAG BIST for self-testing of analog parts of electronic embedded systems is presented in the paper. The JTAG BIST consists of the BCT8244A and SCANSTA476 integrated circuits of Texas Instruments controlled via the IEEE 1149.1 bus. The BCT8244A is a scan test device with octal buffers, and the SCANSTA476 is a 12-bit ADC with 8 analog input channels. Self-testing approach is based on the fault...
-
Electric shock hazard in circuits with variable-speed drives
PublikacjaThe conventional approach to electrical safety under fault condition in typical power systems considers earth fault currents of sinusoidal waveform and frequency of 50/60 Hz. However, in circuits with variable-speed drives, there is earth fault current flow with harmonics, and these harmonics influence the threshold of ventricular fibrillation. The paper presents earth fault current waveforms in circuits with variable-speed drives...
-
Residual Current Devices: Selection, Operation, and Testing
PublikacjaIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Hyperelastic Microcantilever AFM: Efficient Detection Mechanism Based on Principal Parametric Resonance
PublikacjaThe impetus of writing this paper is to propose an efficient detection mechanism to scan the surface profile of a micro-sample using cantilever-based atomic force microscopy (AFM), operating in non-contact mode. In order to implement this scheme, the principal parametric resonance characteristics of the resonator are employed, benefiting from the bifurcation-based sensing mechanism. It is assumed that the microcantilever is made...
-
Faults and Fault Detection Methods in Electric Drives
PublikacjaThe chapter presents a review of faults and fault detection methods in electric drives. Typical faults are presented that arises for the induction motor, which is valued in the industry for its robust construction and cost-effective production. Moreover, a summary is presented of detectable faults in conjunction with the required physical information that allow a detection of specific faults. In order to address faults of a complete...
-
Possibility of Fault Detection in Sensorless Electric Drives
PublikacjaThe work presents a fault detection method for an induction motor drive system with inverter output filter. This approach make use of a load torque state observer, which complete structure is presented along with the used control structure. Moreover, the demonstrated drive system operates without rotor speed measurement in conjunction with the multiscalar control. The verification of the demonstrated idea was performed on an experimental...
-
Diagnostic system of wheeled tractors detecting four defect's categories
PublikacjaIn a classical approach to damage diagnosis, the technical condition of an analyzed machine is identified based on the measured symptoms, such as performance, thermal state or vibration parameters. In wheeled tractor the fundamental importance has monitoring and diagnostics during exploitation concerning technical inspection and fault element localizations. The main functions of a diagnostic system are: monitoring tractor components...
-
Sensorless Fault Detection of Induction Motor with Inverter Output Filter
PublikacjaThe paper presents the problem of monitoring and fault detection of a sensorless voltage inverter fed squirrel cage induction motor with LC filter. The detection is based on load torque estimation of the investigated torque transmission system. The load torque is calculated besides the computation of other variables that are mandatory for sensorless drive operation such as rotor flux and speed. The implemented LC filter smooths...
-
Fault detection in electronic circuits using test buses
PublikacjaA survey of test buses designed for diagnostics of digital and analog electronic circuits is presented: the IEEE 1149.1 bus for digital circuits, the IEEE 1149.4 bus for mixed-signal and the IEEE 1149.6 bus for AC coupled complex digital circuits. Each bus is presented with its structure, solution of key elements, particularly boundary registers and a set of test instructions. Diagnosis with the use of the described buses is...
-
Fault detection in the marine engine using a support vector data description method
PublikacjaFast detection and correct diagnosis of any engine condition changes are essential elements of safety andenvironmental protection. Many diagnostic algorithms significantly improve the detection of malfunctions.Studies on diagnostic methods are rarely reported and even less implemented in the marine engine industry.To fill this gap, this paper presents the Support Vector Data Description (SVDD) method as applied to thefault detection...
-
Open-Phase Fault Detection Method for Sensorless Five-Phase Induction Motor Drives with an Inverter Output Filter
PublikacjaThe paper presents the sensorless five-phase induction motor drive implementation with an inverter output filter with third harmonic injection. For the sensorless operation, the required observers are presented for the first and third harmonics with consideration of the inverter output filter. Moreover, the interaction of the observers and the control system is capable to handle a deactivation of one or two phases, which improves...
-
Data-driven models for fault detection using kernel pca:a water distribution system case study
PublikacjaKernel Principal Component Analysis (KPCA), an example of machine learning, can be considered a non-linear extension of the PCA method. While various applications of KPCA are known, this paper explores the possibility to use it for building a data-driven model of a non-linear system-the water distribution system of the Chojnice town (Poland). This model is utilised for fault detection with the emphasis on water leakage detection....
-
Fault detection and diagnostics of complex dynamic systems using Gaussian Process Models - nuclear power plant case study
PublikacjaThe article examines the use of Gaussian Process Models to simulate the dynamic processes of a Pressurized Water nuclear Reactor for fault detection and diagnostics. The paper illustrates the potential of Gaussian Process Models as a tool for monitoring and predicting various fault conditions in Pressurized Water nuclear Reactor power plants, including reactor coolant flow and temperature variations, deviations from nominal working...
-
Evaluating the Use of Edge Device Towards Fall Detection in Smart City Environment
PublikacjaThis paper presents the development and preliminary testing of a fall detection algorithm that leverages OpenPose for real-time human pose estimation from video feeds. The system is designed to function optimally within a range of up to 7 meters from ground-level cameras, focusing exclusively on detected human silhouettes to enhance processing efficiency. The performance of the proposed approach was evaluated using accuracy values...
-
Speed Sensorless AC Drive with Inverter LC Filter and Fault Detection Using Load Torque Signal
PublikacjaThe industrial development in recent years has seen a major increase in the use of induction motors, whereby the cost has to be as low as possible and the lifetime as long as possible. To follow up this desire, investigations in this area have become very intense. For that reason, this paper presents a solution for driving an induction motor and simultaneous fault detection with no need for additional sensors. In order to achieve...
-
Development of an Active Optical Lens for Arc Flashing Detection
Publikacja -
Speed sensorless ac drive with inverter output filter and fault detection using load torque signal
PublikacjaIn this paper, a sensorless induction motor (IM) drive using speed observer system is presented. The system includes load torque computation for gear fault detection. Nonlinear control method is adopted for controlling the motor over a wide speed range. An LC filter for smoothing current and voltage waveforms is used at the output of the voltage inverter. The use of filter imposes more building of the used observer to avoid using...
-
Fault detection in measuring systems of power plants
PublikacjaThis paper describes possibility of forming diagnostic relations based on application of the artifical neural networks (ANNs), intended for the identifying of degradation of measuring instruments used in developed power systems. As an example a steam turbine high-power plant was used. And, simulative calculations were applied to forming diagnostic neural relations. Both degradation of the measuring instruments and simultaneously...
-
A Novel Device and System for Fall Detection Under the Shower
PublikacjaIn this paper, device construction and preliminary results for shower safety assistance are presented. The device allows monitoring of shower-taking persons without violating privacy and intimacy, while it has the ability to detect a persons entering and leaving the shower and detecting fall conditions. It allows better supervision of elders living independently at their locations.
-
On Wilcoxon rank sum test for condition monitoring and fault detection of wind turbines
Publikacja -
Implementation of DEIS for reliable fault monitoring and detection in PEMFC single cells and stacks
PublikacjaDynamic Electrochemical Impedance Spectroscopy (DEIS) was presented as novel method for diagnostic and monitoring of PEMFC stack and single cells operation. Impedance characteristics were obtained simultaneously with current - voltage characteristics for stack and each individual cell. Impedance measurements were performed in galvanodynamic mode. It allowed to compare performance of each cell and identification of faulty cell operation...
-
Condition monitoring and fault detection in wind turbines based on cointegration analysis of SCADA data
Publikacja -
On Cointegration Analysis for Condition Monitoring and Fault Detection of Wind Turbines Using SCADA Data
Publikacja -
Condition monitoring and fault diagnosis of wind turbines based on structural break detection in SCADA data
Publikacja -
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Data-driven models for fault detection using kernel PCA: A water distribution system case study
Publikacja -
Szybkie uziemniki do ograniczania skutków zwarć łukowych w okrętowych rozdzielnicach SN
PublikacjaW artykule scharakteryzowano moc i napięcie łuku, jak również przedstawiono model termodynamiczny służący do obliczania ciśnienia i temperatury gazów w otoczeniu łuku zwarciowego. Przedstawiono przykładowy układ elektrowni okrętowej i zasilania najważniejszych odbiorników na statku do przewozu gazu ziemnego w stanie ciekłym. Na podstawie parametrów prądnic i silników odbiorników zasilanych z rozdzielnicy głównej obliczono prądy...
-
Self-Testing of Analog Parts Terminated by ADCs Based on Multiple Sampling of Time Responses
PublikacjaA new approach for self-testing of analog parts terminated by analog-to-digital converters in mixed-signal electronic microsystems controlled by microcontrollers is presented. It is based upon a new fault diagnosis method using a transformation of the set of voltage samples of the time response of a tested analog part to a square impulse into localization curves placed in a multidimensional measurement space. The method can be used...
-
Application of data driven methods in diagnostic of selected process faults of nuclear power plant steam turbine
PublikacjaArticle presents a comparison of process anomaly detection in nuclear power plant steam turbine using combination of data driven methods. Three types of faults are considered: water hammering, fouling and thermocouple fault. As a virtual plant a nonlinear, dynamic, mathe- matical steam turbine model is used. Two approaches for fault detection using one class and two class classiers are tested and compared.
-
Skutki zwarć łukowych w średnionapięciowych rozdzielnicach okrętowych z izolacją powietrzną
PublikacjaW artykule scharakteryzowano moc i napięcie łuku, jak również przedstawiono model termodynamiczny służący do obliczania ciśnienia i temperatury gazów w otoczeniu łuku zwarciowego. Przedstawiono przykładowy układ elektrowni okrętowej i zasilania najważniejszych odbiorników na statku do przewozu kontenerów, w tym 600 kontenerów chłodzonych. Na podstawie parametrów prądnic i silników, odbiorników zasilanych z rozdzielnicy głównej...
-
A method of self-testing of an analog circuit terminated by an ADC in electronic embedded systems controlled by microcontrollers
PublikacjaA new self-testing method of analog parts terminated by an ADC in electronic embedded systems controlled by microcontrollers is presented. It is based on a new fault diagnosis method based on on-line (i.e. during measurement), transformations of voltage samples of the time response of a tested part to a square pulse - onto localization curves placed in the measurement space. The method can be used for fault detection and single...
-
A method of self-testing of analog circuits based on fully differential op-amps with theTCBF classifier
PublikacjaA new approach of self-testing of analog circuits based on fully differential op-amps of mixed-signal systems controlled by microcontrollers is presented. It consists of a measurement procedure and a fault diagnosis procedure. We measure voltage samples of a time response of a tested circuit on a stimulation of a unit step function given at the common-mode reference voltage input of the op-amp. The fault detection and fault localization...
-
A testing method of analog parts of mixed-signal electronic systems equipped with the IEEE1149.1 test bus
PublikacjaA new solution of the JTAG BIST for testing analog circuits in mixed-signal electronic microsystems controlled by microcontrollers and equipped with the IEEE1149.1 bus is presented. It is based on a new fault diagnosis method in which an analog circuit is stimulated by a buffered signal from the TMS line, and the time response of the circuit to this signal is sampled by the ADC equipped with the JTAG. The method can be used for...
-
Broken Rotor Symptons in the Sensorless Control of Induction Machine
PublikacjaInverter fed sensorless controlled variable speed drives with induction machine are widely used in the industry applications, also in wind power generation and electric vehicles. On-line self diagnostic systems implementation is needed for early stage fault detection and avoiding a critical fault. Diagnostic algorithms in modern DSP-based controllers can operate simultaneously with control system functions. In the closed-loop controlled...
-
Practical issues for the implementation of survivability and recovery techniques in optical networks
PublikacjaFailures in optical networks are inevitable. They may occur during work being done for the maintenance of other infrastructures, or on a larger scale as the result of an attack or large-scale disaster. As a result, service availability, an important aspect of Quality of Service (QoS), is often degraded. Appropriate fault recovery techniques are thus crucial to meet the requirements set by the Service Level Agreements (SLAs) between...
-
Quantum randomness protected against detection loophole attacks
PublikacjaDevice and semi-device-independent private quantum randomness generators are crucial for applications requiring private randomness. However, they are vulnerable to detection inefficiency attacks and this limits severely their usage for practical purposes. Here, we present a method for protecting semi-device-independent private quantum randomness generators in prepare-and-measure scenarios against detection inefficiency attacks....
-
Analiza przepływu gazu w kanałowych reduktorach ciśnienia podczas zwarć łukowych w rozdzielnicach SN
PublikacjaW artykule przedstawiono metodę obliczania ciśnienia i temperatury gazów podczas zwarcia łukowego wewnątrz przedziału wyłącznika rozdzielnicy średniego napięcia z wykorzystaniem modelu termodynamicznego procesów towarzyszących zwarciom łukowym wewnątrz rozdzielnic z izolacją powietrzną. Następnie, w oparciu o mechanikę płynów lepkich, przedstawiono metodę obliczania rozkładu prędkości i ciśnienia gazu w kanałowych reduktorach ciśnienia...
-
Optimising approach to designing kernel PCA model for diagnosis purposes with and without a priori known data reflecting faulty states
PublikacjaFault detection plays an important role in advanced control of complex dynamic systems since precise information about system condition enables efficient control. Data driven methods of fault detection give the chance to monitor the plant state purely based on gathered measurements. However, they especially nonlinear, still suffer from a lack of efficient and effective learning methods. In this paper we propose the two stages learning...
-
Analysis and Detection of Faults at Insulated Conductors of Overhead Medium Voltage Lines
PublikacjaThe paper dealt with the issue of breakdowns detection of isolated hanging wires on the medium-voltage transmission. The main aim of article is to describe the function of created breakdowns detector and evaluation its. The breakdowns detector is created based in indicators of faults such as touch between tree limbs and insulated wire, touch tree limbs with several phases or fall insulated wire on the ground. Breakdowns detector...
-
Non-invasive blood glucose monitoring with Raman spectroscopy: prospects for device miniaturization
PublikacjaThe number of patients with diabetes has reached over 350 million, and still continues to increase. The need for regular blood glucose monitoring sparks the interest in the development of modern detection technologies. One of those methods, which allows for noninvasive measurements, is Raman spectroscopy. The ability of infrared light to penetrate deep into tissues allows for obtaining measurements through the skin without its...
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublikacjaA novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...