Filtry
wszystkich: 2528
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: OPTICAL FIBER SENSORS
-
Autogenous Fiber Laser Welding of 316L Austenitic and 2304 Lean Duplex Stainless Steels
PublikacjaThis study presents results of experimental tests on quality of dissimilar welded joints between 316L austenitic and 2304 lean duplex stainless steels, welded without ceramic backing. Fiber laser welded butt joints at a thickness of 8 mm were subjected to non‐destructive testing (visual and penetrant), destructive testing (static tensile test, bending test, and microhardness measurements) and structure observations (macro‐ and...
-
Model of optical phantoms thermal response upon irradiation with 975 nm dermatological laser
PublikacjaWe have developed a numerical model describing the optical and thermal behavior of optical tissue phantoms upon laser irradiation. According to our previous studies, the phantoms can be used as substitute of real skin from the optical, as well as thermal point of view. However, the thermal parameters are not entirely similar to those of real tissues thus there is a need to develop mathematical model, describing the thermal and...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.2
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.1
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Femtosecond Er-doped fiber laser source tunable from 872 to 1075 nm for two-photon vision studies in humans
PublikacjaWe report the development of a widely-tunable femtosecond fiber laser system and its application for two-photon vision studies. The source is based on an Er-doped fiber laser with spectral shift up to 2150 nm, followed by a second harmonic generation module to generate a frequency-doubled beam tunable from 872 to 1075 nm. The source delivers sub-230 fs pulses with nearly-constant duration over the entire tuning range, with output...
-
Machine-Learning Methods for Estimating Performance of Structural Concrete Members Reinforced with Fiber-Reinforced Polymers
PublikacjaIn recent years, fiber-reinforced polymers (FRP) in reinforced concrete (RC) members have gained significant attention due to their exceptional properties, including lightweight construction, high specific strength, and stiffness. These attributes have found application in structures, infrastructures, wind power equipment, and various advanced civil products. However, the production process and the extensive testing required for...
-
Novel approach to modeling spectral-domain optical coherence tomography with Monte Carlo method
PublikacjaNumerical modeling Optical Coherence Tomography (OCT) systems is needed for optical setup optimization, development of new signal processing methods and assessment of impact of different physical phenomena inside the sample on OCT signal. The Monte Carlo method has been often used for modeling Optical Coherence Tomography, as it is a well established tool for simulating light propagation in scattering media. However, in this method...
-
Label‐free optical detection of cyclosporine in biological fluids
PublikacjaIn this paper, a spectroscopic method for determination of cyclosporine concentrations in biological fluids is presented. Blood plasma and hemoglobin solutions are chosen for the experiment. For various cyclosporine concentrations in blood plasma and hemoglobin, absorbance measurements in spectra range from 600 to 1100 nm are performed. The measurement results are analyzed by the use of a dedicated algorithm. The obtained data...
-
Planning a Cost-Effective Delay-Constrained Passive Optical Network for 5G Fronthaul
PublikacjaWith the rapid growth in the telecommunications industry moving towards 5G and beyond (5GB) and the emergence of data-hungry and time-sensitive applications, Mobile Network Operators (MNOs) are faced with a considerable challenge to keep up with these new demands. Cloud radio access network (CRAN) has emerged as a cost-effective architecture that improves 5GB performance. The fronthaul segment of the CRAN necessitates a high-capacity...
-
Microcrystalline diamond film evaluation by spectroscopic optical coherence tomography
PublikacjaThis study has focused on the microcrystalline diamond film (MCD) thickness evaluation. For this purpose, optical coherence tomography (OCT) enhanced by spectroscopic analysis has been used as a method of choice. The average thickness of the tested layer was about 1.5 µm, which is below the standard 2-point OCT resolution. In this case, the usefulness of the spectroscopic analysis was confirmed for the evaluation of the thickness...
-
Optical measurements of LTO:Cu sol-gel derived thin films
Dane BadawczeLithium titanate doped by copper thin films were manufactured by chemical, sol-gel method. Flms were deposited on a Corning glass substrated by spin coater. To calculated optical band gap and other optcal parameters, UV-VIS spectroscopy measurements were performed. For measurements selected samples with various content of Cu.
-
Integration of inertial sensors and GPS system data for the personal navigation in urban area
PublikacjaGPS and Inertial Navigation Systems (INS) have complementary properties and they are therefore well suited for integration. The integrated solution offers better long-term accuracy than a stand-alone INS and better integrity, availability and continuity or a stand-alone GPS receiver, making it suitable for demanding applications. The complementary features of INS and GPS are the main reasons why integrated GPS/INS systems are becoming...
-
Automatic sound source localization in disturbing conditions using acoustic vector sensors
PublikacjaA concept, practical realization and applications of a passive acoustic radar to automatic localization and tracking of sound sources in disturbing conditions were presented in the paper. The device consists of the new kind of multichannel miniature sound intensity sensors and a group of digital signal processing algorithms. The sensitivity of the realized acoustic radar was examined in free sound field. Several kinds of sound...
-
Giant Reed (Arundo donax L.) Fiber Extraction and Characterization for Its Use in Polymer Composites
PublikacjaThis work describes an extraction method for giant reed fibers from stems and leaves based on chemical soaking and crushing through a rolling mill. Obtained fibers, together with the shredded plant (stems + leaves), are characterized in terms of chemical composition, thermal stability, morphology, and crystallinity. Mechanical properties of fibers have also been assessed (single fiber tensile tests). The results show that the proposed...
-
Nano-porous alumina humidity sensors
PublikacjaW pracy przedstawiono wyniki badań czujników wilgotności przygotowanych na bazie porowatej aluminy.
-
Fluctuation phenomena in semiconductor gas sensors
PublikacjaCzujniki gazu mogą być wytwarzane z cienkiej warstwy półprzewodnika, która po podgrzaniu do odpowiedniej temperatury staje się czuła na gaz. Zjawisko to jest dobrze znane i szeroko opisane w literaturze. Jako wskaźnik detekcji gazu wykorzystuje się zmianę rezystancji stałoprądowej czujnika. Zwiększenie czułości i, co najważniejsze z praktycznego punktu widzenia, selektywności dyskryminacji można uzyskać jeśli warstwa półprzewodnika...
-
Tools for signal analysis of gas sensors
PublikacjaStatystyki drugiego rzedu oraz jklasyczna analiza widmowa są zwykle stosowane do badania sygnałów losowych o rozkładzie gaussowskim. Są one jednak często nieodpowiednie w przypadku analizy niestacjonarnych sygnałów niegaussowskich. Pewne narzędzia do analizy takich sygnałów sa dostępne w bibliotekach środowiska MATLAB. Zostały one wykorzystane do do analizy fluktuacji sygnałów czujników gazów. W artykule przedstawiono system do...
-
On the selectivity of nanostructured semiconductor gas sensors
Publikacja.
-
Gas sensors based on superionic conductors
PublikacjaW pracy przedstawiono przegląd rozwiązań elektrochemicznych czujników gazów na bazie elektrolitów stałych.
-
Materials for potentiometric electrochemical gas sensors
PublikacjaPublikacja przeglądowa na temat zasady działania oraz rodzajów czujników elektrochemicznych gazów.
-
Solid-state electrochemical gas sensors
PublikacjaW pracy przedstawiono budowę i zasadę działania wybranych typów elektrochemicznych czujników gazów zbudowanych na bazie elektrolitów stałych.
-
Journal of Sensors and Sensor Systems
Czasopisma -
Chinese Journal of Sensors and Actuators
Czasopisma -
Journal of Medical Signals and Sensors
Czasopisma -
IEEJ Transactions on Sensors and Micromachines
Czasopisma -
Metal-Organic Frameworks-Based Sensors for the Detection of Toxins in Food: A Critical Mini-Review on the Applications and Mechanisms
PublikacjaUsing scientific technologies to detect toxins in food is significant to prevent food safety problems and protect people’s health. Recently, the rise of sensors has made rapid, efficient, and safe detection of food toxins possible. One of the key factors impacting the sensor’s performance is the nanomaterials employed. Metal-organic frameworks (MOFs), with high specific surface area, tunable composition, porous structure, and flexible...
-
Benchmarking Scalability and Security Configuration Impact for A Distributed Sensors-Server IOT Use Case
PublikacjaInternet of Things has been getting more and more attention and found numerous practical applications. Especially important in this context are performance, security and ability to cope with failures. Especially crucial is to find good trade-off between these. In this article we present results of practical tests with multiple clients representing sensors sending notifications to an IoT middleware – DeviceHive. We investigate performance...
-
Optical activity and electro-optic effect of l-arginine doped KDP single crystals
PublikacjaWe have used the modified polarimetric methods to study optical activity (OA) in the potassium dihydrogenphosphate (KDP) crystals doped with 0.7, 1.4 and 3.8 wt% L-arginine (L-arg) amino acid. Crystals were grown by the temperature reduction method. Small changes of the absolute eigen waves ellipticity and OA values in doped crystals were noted. We have experimentally determined the signs of OA in the [1 00] and [01 0] directions...
-
Grzegorz Lentka dr hab. inż.
OsobyGrzegorz Lentka uzyskał tytuł magistra inżyniera w roku 1996 na Wydziale Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej w zakresie systemów pomiarowych. Stopień doktora nauk technicznych uzyskał w roku 2003, a doktora habilitowanego w 2014. Obecnie zatrudniony jest w Katedrze Metrologii i Optoelektroniki na stanowisku profesora PG. W ramach prowadzonej dydaktyki zajmuje się zagadnieniami związanymi z interfejsami...
-
Optical method for verification of homogeneity of phantoms for calibration of magnetic resonance
PublikacjaThe primary purpose of this study was to develop a laboratory photonic set-up for characterisation of homogeneity of gel phantoms for calibration of magnetic resonance. In this system, optical coherence tomography allows the detection of micro- and macroscopic heterogeneities of a structure. The set-up was used to perform measurements of agar and agar-carrageenan gels, which are the basis for more complex phantoms for magnetic...
-
Optoelectronic and non-linear optical properties of Lu-doped AgGaGe3Se8 crystallites
Publikacja -
OPTICAL AND QUANTUM ELECTRONICS
Czasopisma -
Inverse Modeling and Optimization of CSRR-based Microwave Sensors for Industrial Applications
PublikacjaDesign optimization of multivariable resonators is a challenging topic in the area of microwave sensors for industrial applications. This paper proposes a novel methodology for rapid re-design and parameter tuning of complementary split-ring resonators (CSRRs). Our approach involves inverse surrogate models established using pre-optimized resonator data as well as analytical correction techniques to enable rapid adjustment of geometry...
-
Detection of petroleum products using optical coherence tomography
PublikacjaIn this work, we present a novel method developed for the analysis of the properties of thin layers for detecting petroleum products on a water surface using a commercially available optical coherence tomography (OCT) system. The spectral density analysis of the signal from a spectroscopic OCT (S-OCT) enables us to perform the precision calculation of the thin layer thickness and other properties like homogeneity, and dispersion,...
-
Integrated acoustical-optical system for inventory of hydrotechnical objects
PublikacjaThe knowledge of the location, shape and other characteristics of spatial objects in the coastal areas has a significant impact on the functioning of ports, shipyards, and other waterinfrastructure facilities, both offshore and inland. Therefore, measurements of the underwater part of the waterside zone are taken, which means the bottom of the water and other underwater objects (e.g. breakwaters, docks, etc.), and objects above...
-
Semi complex navigation with an active optical gesture sensor
PublikacjaThis paper presents the methods of diversified touchless interactions between a user and a mobile platform utilizing the optical gesture sensor. The sensor uses 8 photodiodes to measure the reflected light in the active mode (using embedded LEDs) or it measures shadows caused by fingers in the passive mode. Several algorithms were implemented: automatic mode switching, adaptive illumination level compensation, resolution improvements...
-
Efficient signal processing in spectroscopic optical coherence tomography
PublikacjaSpectroscopic optical coherence tomography (SOCT) is an extension of a standard OCT technique, which allows to obtain depth-resolved, spectroscopic information on the examined sample. It can be used as a source of additional contrast in OCT images e.g. by encoding certain features of the light spectrum into the hue of the image pixels. However, SOCT require computation of time-frequency distributions of each OCT A-scan, what is...
-
Multianalyte Calibration Methods for Potentiometric Integrated Sensors System for Determination of Ions Concentration in a Body Fluids
PublikacjaIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in a small sample volume. One of the key problems related to the preparation of integrated sensors systems (ISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim of the research...
-
Polarization sensitive optical coherence tomography for technical materials investigation
Publikacja -
Polarization sensitive optical coherence tomography for technical materials investigation
PublikacjaZaprezentowano system optycznej tomografii koherentnej z analizą stanu polaryzacji światła. System umożliwia nieniszczące i bezkontaktowe badanie wewnętrznej struktury materiałów warstwowych. Przedstawiono zastosowaną metodę analizy stanu polaryzacji promieniowana wstecznie rozproszonego od badanego obiektu.
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.3
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.4
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.5
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Real-time working gas recognition system based on the array of semiconductor gas sensors and portable computer Raspberry PI
PublikacjaThe gas-analyzing systems based on the array of partially selective gas sensors and pattern-recognition techniques are potentially fast and low-cost alternative for other devices, like gas analysers. They give the possibility of recognition the type and the concentration of measured volatile compounds in their working environment. In this work we present the implementation of gas recognition system, in which the signals from an...
-
Optimised Allocation of Hard Quality Sensors for Robust Monitoring of Quality in Drinking Water Distribution Systems
PublikacjaA problem of optimised placement of the hard quality sensors in Drinking Water Distribution Systems for robust quality monitoring is formulated. Two numerical algorithms to solve the problem are derived. The optimality is meant as achieving a desired trade off between the sensor capital and maintenance costs and resulting robust estimation accuracy of the monitoring algorithm. The robust estimation algorithm recently developed...
-
Guangxue Jishu/Optical Technique
Czasopisma -
Improved surface coverage of an optical fibre with nanocrystalline diamond by the application of dip-coating seeding
PublikacjaGrowth processes of diamond thin films on the fused silica optical fibres (10 cm in length) were investigated at various temperatures. Fused silica pre-treatment by dip-coating in a dispersion consisting of detonation nanodiamond (DND) in dimethyl sulfoxide (DMSO) with polyvinyl alcohol (PVA) was applied. Nanocrystalline diamond (NCD) films were deposited on the fibres using the microwave plasma assisted chemical vapour deposition...
-
Efficient Complex Root Finding Algorithm for Microwave and Optical Propagation Problems
PublikacjaArticle relates to the use of innovative root finding algorithm (on a complex plane) to study propagation properties of microwave and optical waveguides. Problems of this type occur not only in the analysis of lossy structures, but also in the study of complex and leaky modes (radiation phenomena). The proposed algorithm is simple to implement and can be applied for functions with singularities and branch cuts in the complex plane...
-
In-situ optical diagnostics of boron-doped diamond films growth
PublikacjaInterferometry is a desirable method for in-situ measurement of thin, dielectric film growth, as it don't modify conditions of film deposition. Here we present interferometrical measurements of thickness of doped diamond films during Chemical Vapor Deposition (CVD) process. For this purpose we used a semiconductor laser with a 405nm wavelength. Additional ex-situ measurement using spectral interferometry and ellipsometry...
-
Second and third harmonic nonlinear optical process in spray pyrolysed Mg:ZnO thin films
Publikacja