Filtry
wszystkich: 15410
-
Katalog
- Publikacje 10484 wyników po odfiltrowaniu
- Czasopisma 437 wyników po odfiltrowaniu
- Konferencje 41 wyników po odfiltrowaniu
- Osoby 190 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Kursy Online 140 wyników po odfiltrowaniu
- Wydarzenia 2 wyników po odfiltrowaniu
- Dane Badawcze 4113 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: DISEASES , WAVELET TRANSFORMS , WAVELET ANALYSIS , GASTROINTESTINAL TRACT , ESOPHAGUS , SENSITIVITY , IMPEDANCE MEASUREMENT
-
Business Process Analysis and Optimization 2022
Kursy Online -
Business Process Analysis and Optimization 2023
Kursy Online -
Methods of quantitative analysis (team project)
Kursy Online -
E-marketing and trend analysis - 2022
Kursy Online -
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of nano-nickel based coating sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of nano-nickel based coating sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 3
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name EPCS1) sample 3. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Analysis of the instantaneous power signal for bearing diagnostics -bearing damaged
Dane BadawczeThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of a damaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Analysis of the instantaneous power signal for bearing diagnostics - bearing undamaged
Dane BadawczeThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of an undamaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Analysis of Properties of an Active Linear Gesture Sensor
PublikacjaBasic gesture sensors can play a significant role as input units in mobile smart devices. However, they have to handle a wide variety of gestures while preserving the advantages of basic sensors. In this paper a user-determined approach to the design of a sparse optical gesture sensor is proposed. The statistical research on a study group of individuals includes the measurement of user-related parameters like the speed of a performed...
-
Quantum Steering Inequality with Tolerance for Measurement-Setting Errors: Experimentally Feasible Signature of Unbounded Violation
Publikacjauantum steering is a relatively simple test for proving that the values of quantum-mechanical measurement outcomes come into being only in the act of measurement. By exploiting quantum correlations, Alice can influence — steer — Bob ’ s physical system in a way that is impossible in classical mechanics, as shown by the violation of steering inequalities. Demonstrating this and similar quantum effects for systems of increasing size,...
-
Electrochemical impedance spectra and CV curves of V2O5 nanocrystals
Dane BadawczeThe DataSet contains the EIS spectra for coin-cells and CV curves with the V2O5 nanocrystals obtained by the sol-gel method. Cyclic voltammetry and electrochemical impedance spectroscopy (EIS) were measured using the AUTOLAB 302N potentiostat-galvanostat under Nova software. The EIS measurements were recorded in the frequency range 100 kHz to 10 mHz...
-
Electrochemical impedance spectra and CV curves of V2O5 nanorods
Dane BadawczeThe DataSet contains the EIS spectra for coin-cells and CV curves with the V2O5 nanorods obtained by the sol-gel method. Cyclic voltammetry and electrochemical impedance spectroscopy (EIS) were measured using the AUTOLAB 302N potentiostat-galvanostat under Nova software. The EIS measurements were recorded in the frequency range 100 kHz to 10 mHz for...
-
On the characteristic impedance definition in microstrip and coplanar lines
PublikacjaW niniejszej pracy rozważono definicję impedancji charakterystycznej dla bezstratnych linii mikropaskowych i koplanarnych. Wykazano, że ze względu na znaczne wartości prądu przesunięcia związanego z podłużną składową pola elektrycznego, definicja impedancji staje się niejednoznaczna. W rezultacie może to przyczyniać się do istotnych błędów powstających już na etapie projektowania układów. Pokazano, iż efekt ten jest szczególnie...
-
Instantaneous electrochemical impedance spectroscopy of electrode reactions
Publikacja -
The time dependence of pit creation impedance spectra
Publikacja -
Impedance measurements of coating properties on bridge structures
PublikacjaPomiary impedancyjne pozwalają na prostą ocenę właściwości ochronnych powłok ochronnych i wykładzin. Pomiary stosuje się w celu porównania powłok, monitorowania ich właściwości i oceny mechanizmu działania. Metodyka jest z powodzeniem stosowana w pomiarach laboratoryjnych. Pomiary terenowe są bardziej skomplikowane ponieważ wymagają w pełni kontrolowanych komputerowo przyrządów, kontroli warunków pogodowych oraz wielu innych parametrów...
-
Instantaneous electrochemical impedance spectroscopy of electrode reactions.
PublikacjaUstalona została ciągła transformata STFT sinusoidalnego sygnału pobudzeniai odpowiedzi prądowej dla pierwszorzędowej reakcji elektrodowej. Impedancja elektrodowa wyznaczona została w łącznej dziedzinie czasowo-częstotliwościowej. Wykonano pomiary reakcji redukcji Cd(II) na kapiącej elektrodzie rtęciowej w funkcji czasu. Zaprezentowano możliwość wyznaczania chwilowych widm impedancyjnych. Opisano czasowe charakterystyki rezystancji...
-
The time dependence of pit creation impedance spectra.
PublikacjaPrzeprowadzono pomiar impedancyjny w warunkach chronoamperometrycznych uzyskując zmiany impedancji układu w czasie. Na ich podstawie wyznaczono zmiany rezystancji przeniesienia ładunku i pojemności w czasie opisujące inicjację i rozwój korozji wżerowej. Potwierdzono użyteczność dynamicznej elektrochemicznej spektroskopii impedancyjnej w badaniu korozji wżerowej.
-
Change of myocardial impedance during experimental ischemia.
PublikacjaW pracy omówiono możliwość monitorowania procesu niedotlenienia za pomocą pomiarów immitancyjnych. Przedstawiono skonstruowane stanowisko pomiarowe ze szczególnym uwypukleniem właściwości sondy pomiarowej. Przedstawiono wyniki eksperymentalnego niedotlenienia u świń wywołanego zamknięciem LAD.
-
Evaluation of coating systems using impedance spectroscopy
PublikacjaTrwałość powłokowych systemów ochronnych zależy od oddziaływań środowiska i związana jest nieodwracalnymi procesami chemicznymi i fizycznymi. Zastosowanie spektroskopii impedancyjnej pozwala na określenie obszaru zastosowań danej powłoki i prognozowanie okresu jej trwałości. W pracy zamieszczono przykłady oceny trwałości systemów powłokowych stosowanych w strategicznych konstrukcjach.
-
Advances in electrical impedance methods in medical diagnostics
PublikacjaOmówiono elektroimpedancyjne metody diagnostyczne i aparaturę pomiarową opracowane w Politechnikach - Gdańskiej i Warszawskiej.Przedyskutowano właściwości elektryczne różnych tkanek biologicznych, omówiono konstrukcję celek i elektrod do pomiarów in vivo oraz in vitro. Opisano konstrukcję wybranych systemów pomiarowych - pletyzmografów, kardiografów i tomografów elektroimpedancyjnych a także stosownego oprogramowania, np. rekonstrukcji...
-
The surface of the sensor used in the analysis of odorous substances
Dane BadawczeHuman industrial activity usually leads to smaller or larger interference with the ecosystem, contributing to changes affecting the quality of life. An example may be the emission of gaseous substances, not necessarily toxic, but due to their intense smell, they can cause discomfort to people exposed to their inhalation. The problem is so important...
-
Computationally-efficient design optimisation of antennas by accelerated gradient search with sensitivity and design change monitoring
PublikacjaElectromagnetic (EM) simulation tools are of primary importance in the design of contemporary antennas. The necessity of accurate performance evaluation of complex structures is a reason why the final tuning of antenna dimensions, aimed at improvement of electrical and field characteristics, needs to be based on EM analysis. Design automation is highly desirable and can be achieved by coupling EM solvers with numerical optimisation...
-
Automatic Clustering of EEG-Based Data Associated with Brain Activity
PublikacjaThe aim of this paper is to present a system for automatic assigning electroencephalographic (EEG) signals to appropriate classes associated with brain activity. The EEG signals are acquired from a headset consisting of 14 electrodes placed on skull. Data gathered are first processed by the Independent Component Analysis algorithm to obtain estimates of signals generated by primary sources reflecting the activity of the brain....
-
Roughness evaluation of turned composite surfaces by analysis of the shape of Autocorrelation Function
PublikacjaIn this paper, the application of an Autocorrelation Function for the characterisation of surface topography was validated. The roughness evaluation of turned composite surfaces was supported by sophisticated studies of the Autocorrelation Function properties, considering especially the shape of the function. Details were measured with the optical method. The selection of the surface roughness evaluation procedures was carried...
-
Wiktoria Wojnicz dr hab. inż.
OsobyDSc in Mechanics (in the field of Biomechanics) - Lodz Univeristy of Technology, 2019 PhD in Mechanics (in the field of Biomechanics) - Lodz Univeristy of Technology, 2009 (with distinction) Publikacje z listy MNiSW (2009 - ) Wojnicz W., Wittbrodt E., Analysis of muscles' behaviour. Part I. The computational model of muscle. Acta of Bioengineering and Biomechanics, Vol. 11, No.4, 2009, p. 15-21 Wojnicz W., Wittbrodt E., Analysis...
-
Reduction of measurement data before Digital Terrain Model generation vs. DTM generalisation
PublikacjaModern data acquisition technologies provide large datasets that are not always necessary in its entirety to properly accomplish the goal of the study. In addition, such datasets are often cumbersome for rational processing, and their processing is time and labour consuming. Therefore, methods that enable to reduce the size of the measurement dataset, such as the generalization of the Digital Terrain Model (DTM) or the reduction...
-
Simultaneous measurements of ECG, body Impedance and temperature
Dane BadawczeThe data are complementary part of the experiment designed to demonstrate how to use the network protocols to transmit medical data. The dataset contains biomedical signals of ECG, Impedanc and temperature acquired simultaneously. The data allow students to become familiar with data acquisition methods (simulate data transmission by medical device over...
-
Four-state measurement method for direct-reading noise figure measurement of low-gain two-ports.
PublikacjaOmówiono problemy techniczne pomiaru współczynnika szumu dwuwrotników o małym wzmocnieniu mocy dysponowanej realizowanych przy stosowaniu znanych metod pomiaru współczynnika szumu. Przedstawiono nową czterostanową metodę pomiaru umożliwiającą uniezależnienie wskazań automatycznego miernika współczynnika szumu zarówno od wartośći wzmocnienia dwuwrotnika badanego jak i współczynnika szumu odbiornika pomiarowego. Wyprowadzone zależności...
-
Linear impedance of Bi2VO5.5 glass-ceramic measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of Bi2VO5.5 glass-ceramic prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Measurement of pulse signal period from incremental encorder by counters of Multifunctuin DAQ devices.
PublikacjaW artykule omówiono parametry liczników znajdujących się na wielofunkcyjnych kartach akwizycji sygnałów pomiarowych. Przedstawiono przygotowane w środowisku programowania Lab VIEW aplikacje wykorzystujące te liczniki. Służą one do pomiaru i rejestracji długości zadanej liczby okresów mierzonego sygnału oraz liczby okresów uzależnionej od ich długości (metoda zliczania zależnego z wydłużonym czasem pomiaru). Aplikacje te zostały...
-
Measurement data of cyclic voltammetry and electrochemical impedance measurements of carbon samples synthesized on axes and off axes
Dane BadawczeThe electrochemical performance of the multielectrode samples were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) using a VMP-300 BioLogic galvanostat potentiostat (France) under the EC-lab software. All electrochemical investigations were carried out in a three-electrode cell system. The carbon multi-electrode,...
-
Comparison of the measurement techniques employed for evaluation of ambient air odour quality
PublikacjaThe paper presents the results of investigation on ambient air odour quality in a vicinity of the industrial sewage treatment plant being a part of the crude oil processing plant. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. The field...
-
Katarzyna Kubiszewska dr
OsobyKatarzyna Kubiszewska pracuje w Katedrze Finansów o 2008 r. i prowadzi zajęcia z finansów i bankowości. W pracy naukowej interesuje się transformacją systemów bankowych w regionie Europy Centralno - Wschodniej, ale także finansowaniem sektora kultury. Publikacje dotyczą dziedziny nauk społecznych w zakresie dyscypliny ekonomia i finanse. Od 2019 r. współpracuje z czasopismami takimi jak Economic Research-Ekonomska Istrazivanja,...
-
Analysis of cell cycle distribution
Dane BadawczeThe dataset comprehensively details the distribution of A549, H226, and H460 cell lines in various cell cycle phases following treatment with the IC90 concentration of selected anthraquinones. The analysis was performed using the Flowing Software 2.
-
Nondestructive Testing of the Miter Gates Using Various Measurement Methods
PublikacjaWhen any problems related to civil engineering structures appear, identifying the issue through the usage of only one measuring method is difficult. Therefore, comprehensive tests are required to identify the main source. The strains and displacement measurements, as well as modal identification, are widely used in the nondestructive testing of structures. However, measurements are usually carried out at several points and confirm...
-
MEASUREMENT O F HEALTHCARE SYSTEM EFFICIENCY IN OECD COUNTRIES
PublikacjaIncreased spending on healthcare systems in many countries tends to attract attention to their efficiency. The aim of this paper is to evaluate the efficiency of healthcare systems in the OECD countries and indicate causes of inefficiency by applying Data Envelopment Analysis (DEA) and using additive and super-efficiency models. The homogeneity of the sample is assessed and outliers are excluded. A ranking is established on the...
-
Balance recognition on the basis of EEG measurement.
PublikacjaAlthough electroencephalography (EEG) is not typically used for verifying the sense of balance, it can be used for analysing cortical signals responsible for this phenomenon. Simple balance tasks can be proposed as a good indicator of whether the sense of balance is acting more or less actively. This article presents preliminary results for the potential of using EEG to balance sensing....
-
Measurement of surface flatness after lapping
PublikacjaPrzedstawiono sposób pomiaru płaskości powierzchni w docieraniu z wykorzystaniem metody sztucznych baz Vickersa. W analizie wykorzystano skomputeryzowane stanowisko do badań mikroskopowych, wyposażone w mikroskop stereoskopowy, kamerę CCD oraz program MultiScan.
-
Measurement of dileptons with the CBM experiment at FAIR
Publikacja -
Measurement techniques of tailored optical fibers
Publikacja -
The problem of “spectrum leakage” in the measurement of harmonics
Publikacja -
Measurement of corporate reputation as perceived by investors
Publikacja -
Low-coherence method of hematocrit measurement
PublikacjaW artykule opisano niskokoherencyjna metodę pomiaru hematokrytu krwi.
-
Measurement platform for training of electronic nose
PublikacjaW pracy zaprezentowano platformę do badania elektronicznego nosa. Zaproponowane rozwiązanie umożliwia trening elektronicznego nosa oraz pomiar charakterystyk czujników gazów.
-
Linear impedance of strontium–borate glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of strontium–borate glass was measured by impedance spectroscopy method.
-
Hybrid Analysis of Structures Composed of Axially Symmetric Objects
Publikacja— A hybrid method for the scattering problems in shielded and open structures is presented. The procedure is based on the combination of body-of-revolution involving finite-element methods with impedance matrix formulation and the mode-matching technique, which can be utilized for the analysis of structures with axially symmetrical scatterers. In order to confirm the validity and efficiency of the proposed approach, a few examples...