Filtry
wszystkich: 2761
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: SHORT-CIRCUIT RESPONSE
-
Induction Generator with Direct Control and a Limited Number of Measurements on the Side of the Converter Connected to the Power Grid
PublikacjaThe article presents an induction generator connected to the power grid using the AC/DC/AC converter and LCL coupling filter. Three-level inverters were used in the converter, both from the generator side and the power grid side. The algorithm realizing Pulse Width Modulation (PWM) in inverters has been simplified to the maximum. Control of the induction generator was based on the Direct Field-Oriented Control (DFOC) method. At...
-
Current divider-based nanosecond high current pulse measuring systems
PublikacjaThis paper presents the analysis of the new approach to the measurement methodology of significant values (in order of hundreds of kA) and huge steepness (in order of MA/μs) current pulses based on current dividers along with a comparison of the various types transducers suitability in measuring systems with such extreme parameters. Such dividers are used to extend the measurement ranges of current transducers with limited current...
-
Identification of volatile compounds based on the electrocatalytic gas sensor responses
PublikacjaMeasured response in case of electrocatalytic gas sensors is in form of a voltamperometric characteristic. Current-voltage (I-V) response shape depends on the gas type and its concentration. Such response contains significantly more information comparing with typical electrochemical sensors, but is quite difficult to analyze. When I-V curve contains current peaks, position of such peaks can be used...
-
Time-current tripping curves of arc fault detection devices
PublikacjaTripping curves of arc fault detection devices, in accordance with PN-EN 62606 “General requirements for arc fault detection devices” have been presented in the paper. Consequently the most fundamental differences in arc fault detection devices tripping compared to circuit-breakers and residual current devices have been indicated.
-
Electrochemical cell impedance spectra at Eoc+100mV
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc+200mV
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc-100mV
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc-200mV
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Shaking table experimental study on the effectiveness of polymer bearings for seismic isolation of structures
PublikacjaSeismic isolation has been recognised to be a very effective way of protecting structures from damage during earthquakes. It allows us to extend the natural period of the structure and therefore avoid resonance with the ground motion. Moreover, by increasing damping in the isolation devices, more energy can be dissipated and thus the structural response can be further reduced. The aim of this paper is to show the results of the...
-
Locking effects in finite elemnt method
PublikacjaIn the present paper a short survey of the locking effect literature is given. As this area of scientific research is still developing, the author of the paper restricted it to about 70 papers. This study is proposed as an introduction to the comprehensive investigation of locking effects.
-
Wideband crossover structure with double ring resonators
PublikacjaThe structure of a four-port microstrip crossover is presented. The device is composed of two ring resonators, one circular and one built from meander lines, connected by four straight lines. The equivalent circuit model of the crossover is derived. The structure is designed on thin and flexible substrate to allow it to bend. The possibility of applying the device on curved surfaces is tested experimentally.
-
Free-air anomaly grid on the Gulf of Gdańsk
Dane BadawczeWe present an attempt to determine the accuracy of shipborne gravimetry for the needs of geoid determination. The shipborne gravity campaign, is the beginning of a series of gravimetry measurements in the Polish Exclusive Economy Zone. The campaign was conducted in the area where the accuracy of geoid determination is crucial for the safety of navigation...
-
SEMG signal database for the automated upper limb rehabilitation process
Dane BadawczeAn automated rehabilitation device control system requires information about the patient's physiological condition. This is possible thanks to the use of biological feedback in the form of electromyography and surface signals (Surface Electromyography, SEMG).
-
Fast Multi-Objective Optimization of Narrow-Band Antennas Using RSA Models and Design Space Reduction
PublikacjaComputationally efficient technique for multi-objective design optimization of narrow-band antennas is presented. In our approach, the corrected low-fidelity antenna model (obtained through coarse-discretization EM simulations) is enhanced using frequency scaling and response correction, sampled, and utilized to obtain a fast response surface approximation (RSA) antenna surrogate. The RSA model is constructed in the reduced design space....
-
Rapid Yield Estimation and Optimization of Microwave Structures Exploiting Feature-Based Statistical Analysis
PublikacjaIn this paper, we propose a simple, yet reliable methodology to expediteyield estimation and optimization of microwave structures. In our approach,the analysis of the entire response of the structure at hand (e.g., $S$-parameters asa function of frequency) is replaced by response surface modeling of suitablyselected feature points. On the one hand, this is sufficient to determinewhether a design satisfies given performance specifications....
-
Nonlinear numerical simulation of earthquake-induced pounding between timber frame buildings
PublikacjaEarthquakes may induce serious dynamic loads acting on buildings, which can lead to damage or even destruction of the whole structure. In densely populated areas, it is quite common that buildings are located very close one to another which can result in pounding between them during ground motions. Due to the environmental awareness, multi-story timber frame buildings are gaining popularity and therefore there is a need to investigate...
-
Using concentrated spectrogram for analysis of audio acoustic signals
PublikacjaThe paper presents results of time-frequency analysis of audio acoustic signals using the method of Concentrated Spectrograph also known as ''Cross-spectral method'' or ''Reassignment method''. Presented algorithm involves signal's local group delay and channelized instantaneous frequency to relevantly redistribute all Short-time Fourier transform lines in time-frequency plain. The main intention of the paper is to compare various...
-
Positron-electron correlation-polarization potentials for the calculation of positron collisions with atoms and molecules
PublikacjaWe present correlation-polarization potentials for the calculation of scattering cross sections of positrons with atoms and molecules. The potentials are constructed from a short-range correlation term and a long-range polarization term. For the short-range correlation term we present four different potentials that are derived from multi-component density functionals. For the long-range polarization term we employ a multi-term...
-
Design considerations for compact microstrip resonant cells dedicated to efficient branch-line miniaturization
PublikacjaA conventional compact microstrip resonant cell (CMRC)has been thoroughly investigated to enhance its slow-wave properties and subsequently ensure an efficient miniaturization of a microstrip circuit. The geometry of a classic CMRC has been improved in terms of slowwave effect in two progressive steps: (i) a single-element topology has been replaced with a double-element one and (ii) a high-impedance section has been refined by...
-
Design and Implementation of a Dual-band Filtering Wil-kinson Power Divider Using Coupled T-shaped Dual-band Resonators
PublikacjaThe paper introduces a novel structure of a dual-band filtering Wilkinson power divider (WPD). Its essential component is a dual-band bandpass filter (BPF), implemented using coupling lines and two T-shaped resonators. The BPF is incorporated into the divider structure to suppress the unwanted harmonics within the circuit. The latter is achieved owing to a wide stopband of the filter. The deigned dual-band WPD can suppress third...
-
Design of a compact planar transmission line for miniaturized rat-race coupler with harmonics suppression
PublikacjaThis paper presents an elegant yet straightforward design procedure for a compact rat-race coupler (RRC) with an extended harmonic suppression. The coupler’s conventional λ/4 transmission lines (TLs) are replaced by a specialized TL that offers significant size reduction and harmonic elimination capabilities in the proposed approach. The design procedure is verified through the theoretical, circuit, and electromagnetic (EM) analyses,...
-
Two-Rate Based Low-Complexity Variable Fractional-Delay FIR Filter Structures
PublikacjaThis paper considers two-rate based structures for variable fractional-delay (VFD) finite-length impulse response (FIR) filters. They are single-rate structures but derived through a two-rate approach. The basic structure considered hitherto utilizes a regular half-band (HB) linear-phase filter and the Farrow structure with linear-phase subfilters. Especially for wide-band specifications, this structure is computationally efficient...
-
Rapid tolerance‐aware design of miniaturized microwave passives by means of confined‐domain surrogates
PublikacjaThe effects of uncertainties, primarily manufacturing tolerances but also incomplete information about operating conditions or material parameters, can be detrimental to the performance of microwave components. Quantification of such effects is essential to ensure a meaningful evaluation of the structure, in particular, its reliability under imperfect fabrication procedures. The improvement of the circuit robustness can be achieved...
-
Low-cost multi-criterial design optimization of compact microwave passives using constrained surrogates and dimensionality reduction
PublikacjaDesign of contemporary microwave circuits is a challenging task. Typically, it has to take into account several performance requirements and constraints. The design objectives are often conflicting and their simultaneous improvement may not be possible; instead, compromise solutions are to be sought. Representative examples are miniaturized microwave passives where reduction of the circuit size has a detrimental effect on its electrical...
-
An idea of an approach to self-testing of mixed signal systems based on a quadratic function stimulation
PublikacjaA new approach to self-testing of the analog parts of mixed-signal electronic systems controlled by microcontrollers equipped with an ADC and a DAC is presented. It is based on a BIST and a new fault diagnosis method. A novelty is the use of the DAC as a component of the BIST, allowing to generate a stimulating signal with a quadratic function shape. It contributes to a better extraction of information about the state of the circuit...
-
Justyna Martyniuk-Pęczek dr hab. inż. arch.
OsobyJustyna Martyniuk-Pęczek, dr hab. inż. arch., urbanista, architekt światła. Doktor habilitowany nauk technicznych w dyscyplinie architektura i urbanistyka, z dodatkową specjalnością architektonicznego projektowania światłem. Podstawowym obszarem jej zainteresowań naukowych jest urbanistyka, w obrębie której skoncentrowała się na trzech nurtach badawczych, a mianowicie: Problemy kształtowania współczesnych przestrzeni publicznych,...
-
BREAST, Mammary gland - Female, 65 - Tissue image [5230730013284131]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
BREAST, Mammary gland - Female, 65 - Tissue image [5230730013288221]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
BREAST, Mammary gland - Female, 65 - Tissue image [5230730013286241]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
BREAST, Mammary gland - Female, 65 - Tissue image [5230730013281441]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
BREAST, Mammary gland - Female, 65 - Tissue image [5230730013287741]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
BREAST, Mammary gland - Female, 65 - Tissue image [5230730013282341]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
BREAST, Mammary gland - Female, 65 - Tissue image [5230730013282511]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
BREAST, Mammary gland - Female, 65 - Tissue image [5230730013279881]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
BREAST, Mammary gland - Female, 65 - Tissue image [5230730013286881]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
BREAST, Mammary gland - Female, 65 - Tissue image [5230730013286141]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Ultrashort Opposite Directed Pulses Dynamics with Kerr Effect and Polarization Account
PublikacjaWe present the application of projection operator methods to solving the problem of the propagation and interaction of short optical pulses of different polarizations and directions in a nonlinear dispersive medium. We restrict ourselves by the caseof one-dimensional theory, taking into account material dispersion and Kerr nonlinearity. The construction of operators is delivered in two variants: for the Cauchy problem and for the...
-
Electricity demand prediction by multi-agent system with history-based weighting
PublikacjaEnergy and load demand forecasting in short-horizons, over an interval ranging from one hour to one week, is crucial for on-line scheduling and security functions of power system. Many load forecasting methods have been developed in recent years which are usually complex solutions with many adjustable parameters. Best-matching models and their relevant parameters have to be determined in a search procedure. We propose a hybrid...
-
Historical carpentry corner log joints—Numerical analysis within stochastic framework
PublikacjaThe paper presents the results of numerical analysis performed on historical, traditional carpentry corner logjoints of two basic topologies: the short-corner dovetail connection and the saddle notch connection. These types of carpentry joints are commonly used in currently preserved objects of wooden architecture. All connections have been modelled in pinewood, which has been defined in the Finite Element software MSC.Marc/Mentat...
-
Combining MUSHRA Test and Fuzzy Logic in the Evaluation of Benefits of Using Hearing Prostheses
PublikacjaAssessing the effectiveness of hearing aid fittings based on the benefits they provide is crucial but intricate. While objective metrics of hearing aids like gain, frequency response, and distortion are measurable, they do not directly indicate user benefits. Hearing aid performance assessment encompasses various aspects, such as compensating for hearing loss and user satisfaction. The authors suggest enhancing the widely used...
-
Sustainable polymers targeted at the surgical and otolaryngological applications: Circularity and future
PublikacjaThe ongoing climate changes, high air and noise pollution have significant impact on humans’ health. This influence is especially visible in otolaryngology, which focuses on respiratory and hearing systems disfunctions. However, even though surgeries are done in response to diseases related to climate changes, they also have a negative impact on the environment, mostly connected with the inherence of single-use fossil fuel derived...
-
Vision Zero in Poland
PublikacjaPoland’s experience of road safety work is relatively short. In the early 1990s road deaths soared to a staggering 8000 a year. A diagnosis found that Poland’s lack of systemic road safety action was to blame for those figures. In response, the state set up road safety bodies and commissioned road safety programs. In 2005, Poland followed the example of Sweden and adopted Vision Zero as a far-reaching concept of changes in road...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 24h exposition
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 48h exposition
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Knowledge Base Suitable for Answering Questions in Natural Language
PublikacjaThis paper presents three knowledge bases widely used by researchers coping with natural language processing: OpenCyc, DBpedia and YAGO. They are characterized from the point of view of questions answering system. In this paper a short description of the aforementioned system implementation is also presented.
-
Projecting procedure for meta-material fiber
PublikacjaWe would like to show new way of derivation evolution equation for short pulses in dielectric waveguide including one model of metamaterial waveguide. This derivation model rely on projecting to the orthogonal basis. In our case to orthogonal basis for cylindrical waveguide.
-
Mechanical properties of sisal fiber-reinforced soybean oil-based polyurethane biocomposites
PublikacjaIn this paper the results of the mechanical properties of polyurethane biocomposites reinforced with short sisal fibers are presented. The fillers were added in different amount: 5, 10 and 15% by mass. Tensile test, hardness, abrasion resistance, elasticity were determined according to the standards.
-
Model Predictive Super-Twisting Sliding Mode Control for An Autonomous Surface Vehicle
PublikacjaThis paper presents a new robust Model Predictive Control (MPC) algorithm for trajectory tracking of an Autonomous Surface Vehicle (ASV) in presence of the time-varying external disturbances including winds, waves and ocean currents as well as dynamical uncertainties. For fulfilling the robustness property, a sliding mode control-based procedure for designing of MPC and a super-twisting term are adopted. The MPC algorithm has been...
-
Fast bubble dynamics and sizing
PublikacjaSingle bubble sizing is usually performed by measuring the resonant bubble response using the Dual Frequency Ultrasound Method. However, in practice, the use of millisecond-duration chirp-like waves yields nonlinear distortions of the bubble oscillations. In comparison with the resonant curve obtained under harmonic excitation, it was observed that the bubble dynamic response shifted by up to 20 percent of the resonant frequency...