Wyniki wyszukiwania dla: PULSE SIGNAL
-
A compact smart sensor based on a neural classifier for objects modeled by Beaunier's model
PublikacjaA new solution of a smart microcontroller sensor based on a simple direct sensor-microcontroller interface for technical objects modeled by two-terminal networks and by the Beaunier’s model of anticorrosion coating is proposed. The tested object is stimulated by a square pulse and its time voltage response is sampled four times by the internal ADC of microcontroller. A neural classifier based on measurement data classifies the...
-
Comparison of the paracetamol electrochemical determination using boron-doped diamond electrode and boron-doped carbon nanowalls
PublikacjaTwo different type of electrodes, boron-doped diamond electrode (BDD) and boron-doped carbon nanowalls (B:CNW) electrode, were used for the electrochemical determination of paracetamol using the cyclic voltammetry and the differential pulse voltammetry in phosphate buffered saline, pH = 7.0. The main advantage of these electrodes is their utilization without any additional modification of the electrode surface. The peak current...
-
Long Distance Vital Signs Monitoring with Person Identification for Smart Home Solutions
PublikacjaAbstract— Imaging photoplethysmography has already been proved to be successful in short distance (below 1m). However, most of the real-life use cases of measuring vital signs require the system to work at longer distances, to be both more reliable and convenient for the user. The possible scenarios that system designers must have in mind include monitoring of the vital signs of residents in nursing homes, disabled people, who...
-
Compact and Integrated High-Power Pulse Generation and Forming System
PublikacjaThis paper presents comprehensive analytical, numerical and experimental research of the compact and integrated high-power pulse generation and forming system based on the flux compression generator and the electro-explosive forming fuse. The paper includes the analysis of the presented solution, starting from the individual components studies, i.e., the separate flux compression generator tests in field conditions and the forming...
-
Application of the laser diode with central wavelength 975 nm for the therapy of neurofibroma and hemangiomas
PublikacjaThis paper presents newly developed dermatological laser (with central wavelength 975 nm) for application in therapies requiring deep penetration of tissue, e.g. cutaneous (dermal) neurofibroma (Recklinghausen disease) and hemangiomas. This laser can work either in pulse or continues wave mode. Laser radiation is transmitted toward the application region by optical fiber with a diameter of 0.6 mm. The compact design of the laser...
-
FFT spectrum based matching algorithm for activedynamic thermography
PublikacjaIn Active Dynamic thermography (ADT) sequences of consecutive temperature distributions are analyzed. In biomedical applications of ADT, the problems of a patient's movements in front of a thermal camera should be eliminated before data analysis. Complete mechanical stabilization of the patients is impossible due to natural voluntary and involuntary moves caused by pulse breathing, etc. This paper presents a simple and efficient...
-
Scanning electrochemical micrographs of poly(lactic acid) 3D printed electrodes ablated by femtosecond laser
Dane BadawczeThe dataset contains the scanning electrochemical micrographs of the femtosecond laser (FSL) ablation at the surface of commercially available carbon black-filled poly(lactic acid) 3D printed electrode. The process is used for the increase of the charge transfer of this electrode in electrochemical studies.
-
Multipulse inverter structures with low voltage distortion
PublikacjaA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse three-level...
-
DC-link voltage balancing in cascaded H-Bridge converters
PublikacjaIn the paper a DC-link voltage balancing strategy for multilevel Cascaded H-Bridge (CHB) converter is proposed. Presented solution bases on optimal choice of active vector durations in Space-Vector Pulse Width Modulation (SV-PWM). It makes it possible to DC-link voltages control and to properly generate the output voltage vector in the case of DC-link voltage unbalance. Results of simulation and experimental researches...
-
Blood Pressure - Pulse Transit Time Relationships: Comparative Studies
PublikacjaA non-invasive and continuous blood pressure estimation could allow a better diagnosis and an earlier detection of various diseases. It could be performed using a photoplethysmography. However, it requires that a relation between blood pressure and pulse transit time is known. Eleven theoretical formulas were used in obtaining the simulated and noise free synthetic data. Then, they were utilized in validation of three, commonly...
-
A New Three-Dimensional Space Vector Modulation for Multilevel Four-Leg Converters Based on the Shape Functions of Tetrahedral Element
PublikacjaThe paper proposes a new three-dimensional space vector pulse-width modulation (3D-SVPWM) algorithm for multilevel four-leg converters. The proposed PWM duty cycle calculation is based on the shape functions of the threedimensional tetrahedral finite elements. The algorithm ensures synthesis of accurate and undistorted output voltages even under significant imbalance or ripple in the DC-link voltages. At the same time, the algorithm...
-
Evaluation of the fast impedance spectroscopy method in the laboratory measurement system
PublikacjaIn this paper the method for fast impedancespectroscopy of technical objects with very high impedance(|Zx| ≥ 1 GΩ) is evaluated by means of simulation and practicalexperiment. The method is based on excitation of an object, witha square pulse and measurements of voltage and currentresponses with DAQ card. The object impedance spectrum isobtained with use of continuous Fourier transform. Someimprovements of the method concerned...
-
Four Level Diode-Clamped Back-To-Back Converter with Active DC Link Voltage Control
PublikacjaThis article presents the design and control of 4L-DC back-to-back converter. To solve the DC link voltage balancing problem in four-level converter a new three-level double chopper topology based on PO-PWM modulation was designed and successfully tested. Also, the paper describes two phase space vector pulse width modulation 2P-SVPWM based on the shape function of finite elements. The control structure with modified Dead-Beat...
-
Determination of Antioxidant Activity of Vitamin C by Voltammetric Methods
PublikacjaVoltammetric methods—cyclic (CV) and differential pulse voltammetry (DPV) are considered the most appropriate way to evaluate antioxidant activity of redox active compounds. They provide information about both mechanism and kinetics of electrochemical oxidation of antioxidants as well as their physical and chemical properties such as the redox potential or the number of electrons transferred. These methods are helpful for understanding...
-
Low harmonic multipulse voltage converters using coupled reactors
PublikacjaThis paper presents a novel approach to the multi pulse voltage converters (VC), especially voltage source inverters (VSI) and matrix converters (MC) based on several typical identical modules connected in parallel using coupled reactors. Such arrangements resulting in lower voltage distortions at extremely low switching frequency. The proposed arrangement was validated by simulation. Laboratory models of 18- and 24pulse 3-level...
-
Accuracy of the discrete Green's function computations
PublikacjaThis paper discusses the accuracy of the discrete Green's function (DGF) computations. Recently closed-form expression of the DGF and its efficient numerical implementation were presented which facilitate the DGF applications in FDTD simulations of radiation and scattering problems. By carefully comparing the DGF results to those of the FDTD simulation, one can make conclusions about the range of the applicability of the DGF for...
-
Long-Term Measurement of Physiological Parameters – Child Dataset
PublikacjaThe dataset titled “Long-term measurement of physiological parameters – child is one dataset” of the bigger series named Long-term measurement of physiological parameters. The dataset contains physiological parameter measurements such as skin temperature and resistance, blood pulse, as well as the stress detection marker, which can have a value of 0 when there is no stress detected or 1 when stress appeared. Additionally, the dataset...
-
Machine learning-based prediction of seismic limit-state capacity of steel moment-resisting frames considering soil-structure interaction
PublikacjaRegarding the unpredictable and complex nature of seismic excitations, there is a need for vulnerability assessment of newly constructed or existing structures. Predicting the seismic limit-state capacity of steel Moment-Resisting Frames (MRFs) can help designers to have a preliminary estimation and improve their views about the seismic performance of the designed structure. This study improved data-driven decision techniques in...
-
Virtual Space Vector Pulse Width Modulation Algorithm for Three-Level NPC Converters Based on the Final Element Shape Functions
PublikacjaThe paper puts forth a novel idea for the computation of Nearest Three Virtual Space Vector Pulse Width Modulation for the three level NPC converters. The computations are based on the concept of final element shape function widely used in the domain of finite element analysis. The proposed approach significantly frees the computations from the use of trigonometric functions, which simplifies the computations and permits easier...
-
Modulacja 3D-SVPWM z kompensacją napięcia niezrównoważenia i balansowaniem napięć DC dla czterogałęziowego falownika 3L-NPC
PublikacjaPrzedstawiono realizację algorytmu modulacji napięcia 3D-SVPWM (ang. 3-Dimensional Space Vector Pulse Width Modulation) z kompensacją napięcia niezrównoważenia dla trójpoziomowego czterogałęziowego falownika 3L-NPC (ang. 3-Level Neutral-Point-diode-Clamped Converter). Do wyznaczania współczynników wypełnień w modulacji szerokości impulsów zastosowano liniowe funkcje kształtu czworościennego elementu skończonego z węzłami, których...
-
Modulacja 3D-SVPWM dla przekształtników wielopoziomowych czterogałęziowych na bazie funkcji kształtu
PublikacjaPrzedstawiono realizację algorytmu modulacji napięcia 3D-SVPWM (ang. 3-Dimensional Space Vector Pulse Width Modulation) dla trójpoziomowego czterogałęziowego przekształtnika 3L-NPC (ang. 3-Level Neutral-Point-diode-Clamped Converter). Do wyznaczania współczynników wypełnień w modulacji szerokości impulsów zastosowano liniowe funkcje kształtu czworościennego elementu skończonego. Proponowany algorytm modulacji nie jest ograniczony...
-
Detection of damages in a rivetted plate
PublikacjaThe paper presents the results of damage detection in a riveted aluminium plate. The detection method has been based on Lamb wave propagation. The plate has been analysed numerically and experimentally. Numerical calculations have been carried out by the use of the time-domain spectral finite element method, while for the experimental analysis laser scanning Doppler vibrometry (LSDV) has been utilised. The panel has been excited...
-
Modified SPWM Technique with Zero-Sequence Voltage Injection for a Five-Phase, Three-Level NPC Inverter
PublikacjaThis article presents a modified sinusoidal pulse-width modulation (SPWM) scheme for a five-phase, three-level neutral-point-clamped inverter. The modulation scheme deploys a modified min–max function to inject the zero-sequence components into the reference modulating signals; hence enabling the effective utilization of the DC-link voltage. Balanced split-input DC-link voltages were achieved through further incorporation of adjustable...
-
Doppler blood flow recordings
Dane BadawczeVital signals registration plays a grate role in biomedical engineering and education process. Well acquired data allow future engineers to observe certain physical phenomenons as well learn how to correctly process and interpret the data. This data set was designed for students to learn about Doppler phenomena and to demonstrate correctly and incorrectly...
-
Optimization-based stacked machine-learning method for seismic probability and risk assessment of reinforced concrete shear walls
PublikacjaEfficient seismic risk assessment aids decision-makers in formulating citywide risk mitigation plans, providing insights into building performance and retrofitting costs. The complexity of modeling, analysis, and post-processing of the results makes it hard to fast-track the seismic probabilities, and there is a need to optimize the computational time. This research addresses seismic probability and risk assessment of reinforced...
-
Effect of pulse laser treatment at different process variables on mechanical behavior of carbon nanotubes electrophoretically deposited on titanium alloy
PublikacjaPurpose: Titanium and its alloys are widely used as biomaterials for long-term implants, but they are usually surface-modified due to their weak bioactivity and wear resistance. Laser processing was used to modify the surface layer, and elemental carbon was a component of the deposited coatings. This research aims to use a combination of both methods based on preliminary electrophoretic deposition of multi-wall carbon nanotubes...
-
Enhancing seismic performance of rigid and semi-rigid connections equipped with SMA bolts incorporating nonlinear soil-structure interaction
PublikacjaNowadays, using smart connections can improve the performance of buildings with some recentering features that are from the superelastic behavior of Shape Memory Alloys (SMAs). It seems that there is different rigidity between the designed connection and the real one in Steel Moment-Resisting Frames (SMRFs), which can be considered as a problematic issue due to the importance of connections in seismic performance assessment. This...
-
SEM micrographs of 3D printed CB-PLA samples topography after microwave treatment
Dane BadawczeThis dataset contains the electrochemical studies on microwave-activated carbon-black doped polylactic acid 3D printed electrodes.
-
Raman spectra and electrochemical data of carbon nanowall with tailored defects
Dane BadawczeThis dataset comprises of Raman spectra aquired with different excitation laser sources and the electrochemical data of defect-induced carbon nanowall electrodes (CNW).
-
Electrochemical studies of poly(lactic acid)-carbon black-nanodiamond composites
Dane BadawczeThis dataset contains electrochemical investigation on electrodes 3D printed using a new composite composed of poly-lactic acid (PLA), carbon black (CB) and nanodiamond fillers. Two types of nanodiamonds were studied: detonation nanodiamonds (DND) and boron-doped carbon nanowalls (BCNW). The presented results contain:1. electrochemical characterisation...
-
Emotion Monitor - Concept, Construction and Lessons Learned
PublikacjaThis paper concerns the design and physical construction of an emotion monitor stand for tracking human emotions in Human-Computer Interaction using multi-modal approach. The concept of the stand using cameras, behavioral analysis tools and a set of physiological sensors such as galvanic skin response, blood-volume pulse, temperature, breath and electromyography is presented and followed...
-
Melamine-modified boron-doped diamond towards enhanced detection of adenine, guanine and caffeine
PublikacjaThis work describes the electrochemical method of boron-doped diamond (BDD) modification by poly-melamine to obtain organic film. The detection of adenine, guanine and caffeine were carried out by differential pulse wave voltammetry. The poly-melamine modified B-NCD electrodes exhibit excellent activity towards the electrochemical oxidation of all examined analytes. The poly-melamine modified BDD electrodes in all measurements...
-
Optimal retrofit strategy using viscous dampers between adjacent RC and SMRFs prone to earthquake‑induced pounding
PublikacjaNowadays, retrofitting-damaged buildings is an important challenge for engineers. Finding the optimal placement of Viscous Dampers (VDs) between adjacent structures prone to earthquake-induced pounding can help designers to implement VDs with optimizing the cost of construction and achieving higher performance levels for both structures. In this research, the optimal placement of linear and nonlinear VDs between the 3-story, 5-story,...
-
Using an IEEE1149.1 Test Bus for Fault Diagnosis of Analog Parts of Electronic Embedded Systems
PublikacjaThe new solution of a BIST called the JTAG BIST for self-testing of analog parts of electronic embedded systems is presented in the paper. The JTAG BIST consists of the BCT8244A and SCANSTA476 integrated circuits of Texas Instruments controlled via the IEEE 1149.1 bus. The BCT8244A is a scan test device with octal buffers, and the SCANSTA476 is a 12-bit ADC with 8 analog input channels. Self-testing approach is based on the fault...
-
Detection Range of Intercept Sonar for CWFM Signals
PublikacjaStealth in military sonars applications may be ensured through the use of low power signals making them difficult to intercept by the enemy. In recent years, silent sonar design has been investigated by the Department of Marine Electronic Systems of the Gdansk University of Technology. This article provides an analysis of how an intercept sonar operated by the enemy can detect silent sonar signals. To that end a theoretical intercept...
-
Time series of Doppler blood flow recordings
Dane BadawczeVital signals registration plays a grate role in biomedical engineering and education process. Well acquired data allow future engineers to observe certain physical phenomenons as well learn how to correctly process and interpret the data. This data set was designed for students to learn about Doppler phenomena and to demonstrate correctly and incorrectly...
-
Synchronized six-step voltage generation in high-speed PMSM drive
PublikacjaSynchronized voltage generation has already been considered in the context of pulse width modulation (PWM). References prove that synchronized PWM substantially decreases subharmonics in inverter output voltage when operating with low switching-to-fundamental frequency ratio. This paper identifies problems of unsynchronized voltage generation in electric drives under six-step inverter operation. Guidelines for the synchronization...
-
Searching of the buried objects into the sea bottom by means of nonlinear acouctic methods
PublikacjaThe main goal of this paper is to introduce the methodology of preparing the area for investigations that will be carried out at the sea. As the first step there is recognition of the basic method both in the theory as well as experimental investigation. There were taken into account the nonlinear methods. These ones are very promising methods that have very interesting features, very convenient for examinations of the seabed structure....
-
A Simplified SPWM Scheme for a Compact 3-Level Dual-Output Inverter
PublikacjaSinusoidal Pulse-width modulation, SPWM, is inverter-leg-based, logical-operation-based, and lesscomputational-intensive. In this brief, these simplifying features of SPWM are extended to the control of the 10-switch, 3-level inverter. The control strategy is based on the single triangular carrier SPWM perspective. Procedures and details of the sharing of four-common power switches by the 3 inverter legs are given. Classically,...
-
Low energy electron attachment to platinum(II) bromide (PtBr2)
PublikacjatDissociative electron attachment to PtBr2in the gas phase was studied in the low electron energy rangefrom zero up to 10 eV with an energy resolution of 150 meV. The experiments were carried out using ahemispherical electron monochromator coupled with a quadrupole mass spectrometer and pulse count-ing acquisition system. The only anion observed was Br−. This ion is formed at three resonance electronenergies: 0.4 eV, 1.2 eV and...
-
An Implementation of a Compact Smart Resistive Sensor Based on a Microcontroller with an Internal ADC
PublikacjaIn the paper a new implementation of a compact smart resistive sensor based on a microcontroller with internal ADCs is proposed and analysed. The solution is based only on a (already existing in the system) microcontroller and a simple sensor interface circuit working as a voltage divider consisting of a reference resistor and the resistive sensor connected in parallel with an interference suppression capacitor. The measurement...
-
Modeling and Evaluation of Electric Treeing Phenomena in Polymeric Cable Insulation
PublikacjaThis paper investigates the treeing phenomenon in polymeric materials such as crosslinked polyethylene (XLPE) that is widely used in medium and high voltage power cables as primary insulation. The modeling of electrical tree growth in the insulation from its initiation to breakdown is significant research work that illustrates the discharge dynamics and its impact on aging process in polymeric insulation. This study utilizes pulse...
-
Recurrent potential pulse technique for improvement of glucose sensing ability of 3D polypyrrole
PublikacjaIn this work, a new approach for using a 3D polypyrrole (PPy) conducting polymer as a sensing material for glucose detection is proposed. Polypyrrole is electrochemically polymerized on a platinum screen-printed electrode in an aqueous solution of lithium perchlorate and pyrrole. PPy exhibits a high electroactive surface area and high electrochemical stability, which results in it having excellent electrocatalytic properties. The...
-
Time frequency representation of Doppler boold flow recordings
Dane BadawczeVital signals registration plays a grate role in biomedical engineering and education process. Well acquired data allow future engineers to observe certain physical phenomenons as well learn how to correctly process and interpret the data. This data set was designed for students to learn about Doppler phenomena and to demonstrate correctly and incorrectly...
-
SiC-based T-type modules for multi-pulse inverter with coupled inductors
PublikacjaThe paper presents SiC-based three-level T-type modules designed for a high-performance 30kVA DC/AC inverter operating at high frequency 85 kHz with low THD of the output voltage. This inverter system consists of two integrated parts. The first part is active and contains three parallelconnected three-phase T-type modules built with fast-switching SiC power transistors. The second, passive part of the system is a set of inductors...
-
Sounding of Layered Marine Bottom - Model Investigations
PublikacjaThe necessary actions connected with interpretations of examining of physical properties of sea bottom structure is developing of proper procedure of modeling of the layered structure. The implementation of the acoustic waves for the determination of seabed stratification requires a precise diagnosis of the topic from both the theoretical and practical side. Little differences between the parameters of sediments, as well as irregular...
-
Effect of strain level on the stiffness of cold recycled bituminous mixtures
PublikacjaCold recycling is a sustainable technology for the rehabilitation of bitumi-nous pavements. This study investigates the stiffness response of cement-bitumen treated materials (CBTM)manufactured with 80% reclaimed asphalt and treated with 2.0% Portland cement and 4.0% bitumen emulsion. Indirect tensile stiffness modulus tests were carried out to assess the strain dependence of stiffness at target horizontal deformation levels between...
-
Performance Comparison of a 650 V GaN SSFET and CoolMOS
PublikacjaThe new technology of wide band gap semiconductors is said to outperform up-to-date silicon devices. High voltage Gallium Nitride (GaN) transistors, now emerging in the market, have even three times shorter switching times and even four times smaller energy losses compared to the best in-class Si devices. In this paper the performance of a 650 V GaN SSFET is evaluated and compared with the newest silicon family of CoolMOS™ technology....
-
Emotion Monitoring – Verification of Physiological Characteristics Measurement Procedures
PublikacjaThis paper concerns measurement procedures on an emotion monitoring stand designed for tracking human emotions in the Human-Computer Interaction with physiological characteristics. The paper addresses the key problem of physiological measurements being disturbed by a motion typical for human-computer interaction such as keyboard typing or mouse movements. An original experiment...
-
Modeling the impact of rotor movement on non-linearity of motor currents waveforms in high-speed PMSM drives
PublikacjaMotor current measurement techniques as well as predictive control algorithms for electric drives rely on an assumption of linear motor currents changes resulting from constant inverter output voltages. Recent research has reported that this assumption does not hold in motors with short electrical time constant, and in drives whose rotor position advances substantially during a control period. This paper proposes a simulation model...