Filtry
wszystkich: 2363
-
Katalog
- Publikacje 1835 wyników po odfiltrowaniu
- Czasopisma 105 wyników po odfiltrowaniu
- Konferencje 7 wyników po odfiltrowaniu
- Osoby 33 wyników po odfiltrowaniu
- Projekty 1 wyników po odfiltrowaniu
- Aparatura Badawcza 2 wyników po odfiltrowaniu
- Kursy Online 6 wyników po odfiltrowaniu
- Wydarzenia 4 wyników po odfiltrowaniu
- Dane Badawcze 370 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: laser direct imaging
-
Reinforced aluminium reference measurement Result1 – earlier tests
Dane BadawczePreliminary testing of aluminium alloys against 100Cr6 steel ball. Preparation to tests on wear of Al6061 alloy in ball on disk experiment. Research on the reinforcing effect of aluminium alloy injection reinforcement with TiN and WC powders in laser remelted surface layer.
-
Janusz Kozak prof. dr hab. inż.
OsobyDr hab. inż. Janusz Kozak Dziekan Wydziału Oceanotechniki i Okrętownictwa Politechniki Gdańskiej Urodzony: 04.07.1953 w Pucku Absolwent Technikum Budowy Okrętów „Conradinum” w Gdańsku, 1973. Absolwent Instytutu Okrętowego PG, 1978. Po ukończeniu studiów praca w Stoczni Gdynia, a od roku 1980 w Katedrze Technologii Okrętów Instytutu Okrętowego a później Wydziału Oceanotechniki i Okrętownictwa Politechniki Gdańskiej kolejno na...
-
AFM and SSRM investiagtion of carbon nanowalls properties
Dane BadawczeStructures with limited dimensionality are of great interest in modern nanotechnology. The properties of these objects are used, among others, for the construction of modern displays or as a base for quantum computers. Carbon nanowalls, which are the subject of the imaging results contained in this collection, are also considered interesting building...
-
A new technique with high reproducibility to estimate renal oxygenation using BOLD-MRI in chronic kidney disease
Publikacja -
NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: A new approach to 3D dosimetry by MRI
Publikacja -
Improving depth maps of plants by using a set of five cameras
PublikacjaObtaining high-quality depth maps and disparity maps with the use of a stereo camera is a challenging task for some kinds of objects. The quality of these maps can be improved by taking advantage of a larger number of cameras. The research on the usage of a set of five cameras to obtain disparity maps is presented. The set consists of a central camera and four side cameras. An algorithm for making disparity maps called multiple...
-
Optimization of the System for Determining the Volume of Tissue Needed for Breast Reconstruction
PublikacjaThis article presents techniques for reconstructing surfaces and volume calculations using a point cloud generated from 3D imaging. The main objective of this article was to optimize the voxel size for the most accurate representation of the surface of the female breast. We experimented with different methods for determining volume using images from the Intel D435i camera. In addition, we designed application and measurement station...
-
3D-Breast System for Determining the Volume of Tissue Needed for Breast Reconstruction
Publikacja3D imaging systems can be used to effectively determine breast volumes for surgical applications. This article presents methods for surface reconstruction and volume determination based on the point cloud created by 3D imaging. Such a system would be used to accurately estimate breast volume in patients classified for breast reconstruction surgery at plastic surgery centers. To develop such a system, various methods of determining...
-
Karol Niklas dr hab. inż.
OsobyKarol NIKLAS jest profesorem Politechniki Gdańskiej (Wydział Inżynierii Mechanicznej i Okrętownictwa, Instytut Budowy Okrętów). Pracę dyplomową magisterską na kierunku "Budowy okrętów morskich" w specjalności "Budowa małych statków i jachtów" obronił w 2007 roku. W 2008 roku ukończył studia podyplomowe w specjalności "Nowoczesne Metody Symulacyjne w Technice" na Wydziale Fizyki i Matematyki Stosowanej. W 2014 roku obronił rozprawę...
-
Modeling of light propagation in canine gingiva
PublikacjaThis study is a preliminary evaluation of the effectivenes of laser-based surgery of maxillary and mandibular bone in dogs. Current methods of gingivial surgery in dogs require the use of general anaesthesia.1, 2 The proposed methods of laser surgery can be performed on conscious dogs, which substantially reduces the associated risks. Two choices of lasers, Nd:YAG and a 930 nm semiconductor lasers were evaluated. The former is...
-
Inwentaryzacja miejsc zdarzeń kryminalnych przy wykorzystaniu naziemnego skaningu laserowego
PublikacjaInwentaryzacja miejsc zdarzeń kryminalnych przy wykorzystaniu naziemnego skaningu laserowego jest rozwiązaniem często spotykanym przy w rozwiniętych krajach Europy i Ameryki Północnej. W Polsce znajdujemy pierwsze zastosowania do rejestrowania zdarzeń kryminalnych o szczególnym stopni skomplikowania lub związanych z nieprzeciętną liczbą ofiar. Zasadniczo jednak skaning laserowy stosuje się w sprawach o zabójstwo, a rzadko w rozwiązaniach...
-
The Role of Thermal Monitoring in Cardiosurgery Interventions
PublikacjaThe results of a research project devoted to the analysis of the value of IR-thermal imaging in monitoring the quality of cardiosurgery interventions are presented. The role of the ADT is underlined.
-
Study of various machine learning approaches for Sentinel-2 derived bathymetry
PublikacjaIn recent years precise and up-to-date information regarding seabed depth has become more and more important for companies and institutions that operate on coastlines. While direct, in-situ measurements are performed regularly, they are expensive, time-consuming and impractical to be performed in short time intervals. At the same time, an ever-increasing amount of satellite imaging data becomes available. With these images, it...
-
"3D-Breast System for Determining the Volume of Tissue Needed for Breast Reconstruction"
PublikacjaThis article presents methods for surface reconstruction and volume determination based on the point cloud created by 3D imaging. Such a system would be used to accurately estimate breast volume in patients classified for breast reconstruction surgery at plastic surgery centers. To develop such a system, various methods of determining volume, based on images from the Intel D435i camera, were tested. In addition, an application...
-
Ball on disk test AL(rf.)-Al2O3-r25
Dane BadawczeHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 25 mm. Disk material: Al6061 not treated (reference).
-
Ball on disk test AL(rf.)-Al2O3-r15
Dane BadawczeHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 15 mm. Disk material: Al6061 not treated (reference).
-
Mechanisms for supporting electric vehicle purchasers in selected European countries in 2011-2016
Dane BadawczeThe European authorities have not developed a single common preference model for electric car buyers within the Union. Different countries have decided on different solutions. The following dataset presents mechanisms for supporting electric vehicle purchasers in selected European countries in years 2011-2016, including both economical (in the form...
-
A method of selecting light sources from night satellite scenes
PublikacjaSatellite images carries a lot of data. Very sophisticated methods of analyses may reveal very complicated nature of the observed objects. In case of night images, lights play the role of information sources. In this paper we would like to present results of the research aimed to describe light sources from satellite night images by providing description of their luminosity. The authors point source imaging data from the satellite...
-
Ball on disk test AT4_11-Al2O3-r25
Dane BadawczeHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 25 mm. Disk material: Al6061 TiN powder injected (AT4_11).
-
Ball on disk test AT3_21-Al2O3-r25
Dane BadawczeHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 25 mm. Disk material: Al6061 TiN powder injected (AT3_21).
-
Ball on disk test AW4_1-Al2O3-r15
Dane BadawczeHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 15 mm. Disk material: Al6061 WC powder injected (AW4_1).
-
Ball on disk test AT4_4-Al2O3-r15
Dane BadawczeHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 15 mm. Disk material: Al6061 TiN powder injected (AT4_4).
-
Ball on disk test AW4_11-Al2O3-r25
Dane BadawczeHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 25 mm. Disk material: Al6061 WC powder injected (AW4_11).
-
Ball on disk test AT4_1-Al2O3-r15
Dane BadawczeHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 15 mm. Disk material: Al6061 TiN powder injected (AT4_1).
-
Ball on disk test AT4_41-Al2O3-r25
Dane BadawczeHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 25 mm. Disk material: Al6061 TiN powder injected (AT4_41).
-
Ball on disk test AT3_2-Al2O3-r15
Dane BadawczeHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 15 mm. Disk material: Al6061 TiN powder injected (AT3_2).
-
Ball on disk test AW4_4-Al2O3-r15
Dane BadawczeHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 15 mm. Disk material: Al6061 WC powder injected (AW4_4).
-
Ball on disk test AW4_41-Al2O3-r25
Dane BadawczeHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 25 mm. Disk material: Al6061 WC powder injected (AW4_41).
-
The morphology of vanadate glass-ceramics containing BaTiO3
Dane BadawczeThe morphology of vanadate glass-ceramic doped with BaTiO3 was measured. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated (573...
-
Topography of barium-vanadate glasses
Dane BadawczeThe topography of barium-vanadate glasses was measured. Samples of the composition of xBaO-(100-x)V2O5 where x= 30, 40 and 45 (in %mol) were prepared by the conventional melt quenching technique. Appropriate amounts of reagents: BaO (≥99.9%, P.P.H STANLAB Sp.J.) and V2O5 (≥99.9%, POCH) were thoroughly mixed in an agate mortar. The melting was performed...
-
Polarization-sensitive optical coherence tomography for ceramic materials inspection
PublikacjaCeramics production is looking for a fast, reliable and non-destructive method that can be implemented on site for defect detection and analysis. In this paper we present polarization-sensitive optical coherence tomography (PS-OCT) as a method for defect inspection. Proposed extensions to standard OCT provide additional information for complete characterization of tested object. We compare OCT and microscope imaging that can easily...
-
Assessment of Wooden Beams from Historical Buildings Using Ultrasonic Transmission Tomography
PublikacjaThe main goal of this study was non-destructive evaluation of wooden elements using ultrasonic waves. The inspection was carried out on wooden beams from a historical object. Elastic wave signals were processed by ultrasonic transmission tomography to obtain imaging of the internal structure of tested elements without disturbing their state and integrity. The focus was on the influence of wood anisotropy on the propagation of ultrasonic...
-
Texture or Linker? Competitive Patterning of Receptor Assembly toward Ultra-Sensitive Impedimetric Detection of Viral Species at Gold-Nanotextured Titanium Surfaces
PublikacjaIn this work, we study the electrodes with a periodic matrix of gold particles pattered by titanium dimples and modified by 3-mercaptopropionic acid (MPA) followed by CD147 receptor grafting for specific impedimetric detection of SARS-CoV-2 viral spike proteins. The synergistic DFT and MM/MD modeling revealed that MPA adsorption geometries on the Au–Ti surface have preferential and stronger binding patterns through the carboxyl...
-
Poultry (chicken) manure biochar - Scanning Electrone Microscope (SEM) images
Dane BadawczeThis dataset contains scanning electron microscope images of poultry (chicken) manure biochars produced at different temperature conditions (400, 500, and 600 degrees Celsius). Imaging was carried out with an FEI Quanta FEG250 scanning electron microscope equipped with a SE-ETD detector (secondary electron - Everhart-Thornley detector) and a 20 kV accelerating...
-
Two-photon microperimetry with picosecond pulses
PublikacjaTwo-photon vision is a phenomenon associated with the perception of short pulsesof near-infrared radiation (900-1200 nm) as a visible light. It is caused by the nonlinear processof two-photon absorption by visual pigments. Here we present results showing the influence ofpulse duration and repetition rate of short pulsed lasers on the visual threshold. We comparedtwo-photon sensitivity maps of the retina obtained for subjects with...
-
COMPARATIVE ANALYSIS OF POINT CLOUDS OBTAINED BY TLS AND PHOTOGRAMMETRY
PublikacjaTechnical progress in the field of 3D modelling resulted in increasing use of such technics to create a virtual 3D models of objects. Three-dimensional spatial models are used in a wide range of applications such as inventorisation of architectural-construction, an inventorisation of archaeological sites, medicine and wide-known engineering. Spatial models are created based on the point clouds acquired with laser scanners or photogrammetry....
-
Remote sensing and photogrammetry techniques in diagnostics of concrete structures
PublikacjaRecently laser scanning technologies become widely used in many areas of the modern economy. In the following paper authors show a potential spectrum of use Terrestrial Laser Scanning (TLS) in diagnostics of reinforced concrete elements. Based on modes of failure analysis of reinforcement concrete beam authors describe downsides and advantages of adaptation of terrestrial laser scanning to this purpose, moreover reveal under which...
-
Nanotechnologies in Development of Structural Materials and Biomaterials
PublikacjaThe nanometric materials and technologies resulted in nanostructures are reviewed. The examples of nanomaterials are shown. The typical nanotechnologies, including plastic deformation, mechanical attrition, controlled detonation, hot plasma jet synthesis, laser vaporisation, CVD and PVD, mechanical milling, annealing, ultrasonic irradiation, nanolithography, electrocrystallisation, electrospinning, sol-gel method, cryogenic laser-enhanced...
-
Historical Wreck Inventory
Dane BadawczeThe measurement solution results in a point cloud obtained from the Leica P30 laser scanner. Another element is the processing of photos into point clouds with the Zenmuse P1 camera of the unmanned Matrice 300 RTK aircraft. The measurement provides complete geometrical information about the wreck. The measurement took place as part of the Photogrammetry...
-
Wpływ stopowania laserowego z użyciem nanorurek węglowych stopu Ti13Nb13Zr do zastosowań biomedycznych na jego wybrane własności mechaniczne
PublikacjaDo eksperymentu użyto stopu tytanu Ti13Nb13Zr, który ze względu na swój skład chemiczny i właściwości mechaniczne stanowi materiał do zastosowań w inżynierii medycznej. Celem pracy była ocena wpływu stopowania laserowego stopu Ti13Nb13Zr z powłoką z wielościennych nanorurek węglowych na jego właściwości mechaniczne (chropowatość, nanotwardość, moduł Younga). Do wytworzenia powłoki węglowej wykorzystano metodę osadzania elektroforetycznego (EDP)....
-
Ewa Kozłowska dr inż.
OsobyEwa Kozłowska has graduated from Gdansk University of Technology in Mechanical and Medical Engineering. She is currently a PhD student at Gdańsk University of Technology in the discipline of mechanical engineering working on the topic of laser surface modifications, heat transfer and also medical device designing with the usage of computer collaboration tools by engineers and physicians.. She’s been taking part in different ERASMUS+...
-
Detection of the acoustic interferences during AFM operation
Dane BadawczeAtomic force microscopy is a particularly complicated surface imaging technique due to the large number of factors that affect the quality of the resulting images. They are obviously difficult and sometimes even impossible to control at the same time. One of such factors may even be the seismological location of the building or the influence of mechanical...
-
Wpływ azotowania jarzeniowego i laserowego nadtapiania na odporność kawitacyjną stali X5CrNi18-10
PublikacjaNierdzewne stale austenityczne charakteryzują się doskonałą odpornością korozyjną, aczkolwiek niskimi właściwościami mechanicznymi. W wielu przypadkach ogranicza to ich eksploatację w warunkach przemysłowych. Ponadto, nierdzewne stale austenityczne są wrażliwe na korozję lokalną w obecności jonów halogenkowych. Technologie materiałowe, które dają potencjalne możliwości otrzymywania korzystnego wpływu na właściwości mechaniczne...
-
Paweł Tysiąc dr inż.
Osobydr inż. Paweł Tysiąc Urodził się 25 marca 1992 w Gdańsku. Po ukończeniu Gimnazjum nr 32 uczęszczał do VIII Liceum Ogólnokształcącego im. Komisji Edukacji Narodowej w Gdańsku, klasy o profilu matematyczno-geograficznym, uzyskując w 2011 roku świadectwo dojrzałości. Następnie w latach 2011-2016 kontynuował naukę na Wydziale Inżynierii Lądowej i Środowiska Politechniki Gdańskiej. Ukończył studia I stopnia w specjalności Geodezja...
-
Designing a high-sensitivity dual-band nano-biosensor based on petahertz MTMs to provide a perfect absorber for early-stage non-melanoma skin cancer diagnostic
PublikacjaThe purpose of this study is development of a novel high-performance low-Petahertz (PHz) biosensor for non-melanoma skin cancer (NMSC) diagnosis. The presented device is designed to work within a microwave imaging regime, which is a promising alternative to conventional diagnostic methods such as visual examination, dermoscopy, and biopsy. The suggested biosensor incorporates a dual-band perfect absorber (operating bands at 0.909...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 250 mA. Sample 24.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 250 mA. Last experiment with sample 24The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,5 V at 180 mA. Sample 24
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,5 V and discharged to 10 mV by constant current 180 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 80 mA. Sample 41.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 80 mA. Sample 41.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,5 V at 241 mA. Sample 24
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,5 V and discharged to 10 mV by constant current 241 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,5 V at 80 mA. Sample 24
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,5 V and discharged to 10 mV by constant current 80 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....