Filtry
wszystkich: 1918
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: ACQUIRED BRAINSTEM RESPONSE
-
Square root RC Nyquist filter of fractional delay
PublikacjaIn this paper we propose a discrete-time FIR (finite impulse response) filter which couples the role of square root Nyquist filter with fractional delay filter. This filter enables to substitute for a cascade of square root RC (SRRC) Nyquist filter and fractional delay filter in one device/algorithm. The aim is to compensate for transmission delay in communication system. Statistically defined performances, e.g. BER (bit error...
-
Nitrogen dioxide sensing properties of PEDOT polymer films
PublikacjaThis work presents a simple and fully electrochemical route for the polymerization of poly(3,4-ethylenedioxytiophene) (PEDOT) films for fabricating a NO2 gas sensor prepared by electropolymerization of 3,4-Ethylenedioxythiophene (EDOT) monomer in lithium perchlorate/acetonitrile solution. The main aim of this study is to determine the sensing properties of conductive polymer at elevated temperatures. The effects of the humidity,...
-
In-plane shear nonlinearity in failure behavior of angle-ply laminated shells
PublikacjaThe paper concerns the progressive failure analysis of laminates with the in-plane shear nonlinearity accounted for.The nonlinear shear response of the layer is described by the constitutive relation treating the stresses as a function of strains. Thus it can be easily incorporated into the displacement-based FEM codes. The brittle failure mechanisms of the fibers and the matrix of the layer are recognized with the use of the Hashin...
-
Comparison of Compact Reduced Basis Method with Different Model Order Reduction Techniques
PublikacjaDifferent strategies suitable to compare the performance of different model order reduction techniques for fast frequency sweep in finite element analysis in Electromagnetics are proposed and studied in this work. A Frobenius norm error measure is used to describe how good job a reduced-order model is doing with respect to the true system response. In addition, the transfer function correct behavior is monitored by studying the...
-
Ecotoxicological equilibria of triclosan inMicrotox, XenoScreen YES/YAS, Caco2, HEPG2 and liposomal systems are affected by the occurrence of other pharmaceutical and personal care emerging contaminants
PublikacjaContaminants of emerging concernmay be considered as any chemicals or factorswhose unintended continuous release and persistence in the environmentmay lead to any observable undesirable response of living beings. Still not much is known on reciprocal toxicological impact of given chemicals when present in binary or more complex mixtures. In thiswork, an attemptwas thus undertaken to study the impact of butylparaben,methylparaben and...
-
Reliability assessment of truss towers using Monte Carlo Method, PEM and RSM
PublikacjaThe paper discusses the reliability assessment of simple random truss structures using three different probabilistic methodologies: the Monte Carlo method, the Point Estimate Method and the Response Surface Method. A benchmark truss structure example is analyzed. A set of numerical calculations of critical load is performed and the results are taken as the basis of advanced probabilistic calculations. Using the samples, numerical...
-
Investigation on accelerated impedance spectrum measurement method with multisine signal stimulation
PublikacjaThe paper presents an investigation on the accelerated impedance spectrum measurement method, oriented at parameter identification of technical objects modelled by a linear equivalent circuit, e.g. anticorrosion coatings.The method is based on multisine signal stimulation of an object and response analysis by triangle window filterbanks.It has several advantages, as compared with conventional point-by-point spectrum measurement....
-
Determination of chlorine concentration using single temperature modulated semiconductor gas sensor
PublikacjaA periodic temperature modulation using sinusoidal heater voltage was applied to a commercial SnO2 semiconductor gas sensor. Resulting resistance response of the sensor was analyzed using a feature extraction method based on Fast Fourier Transformation (FFT). The amplitudes of the higher harmonics of the FFT from the dynamic nonlinear responses of measured gas were further utilized as an input for Artificial Neural...
-
The (Un)Real City by Magdalena Abakanowicz: Guidelines for Cities in Times of Planetary Crisis
PublikacjaThree decades have passed since Magdalena Abakanowicz presented her concept of Bois de Nanterre — Arboreal Architecture, in response to a call for a broader reflection on approaches to urban landscaping and a reinterpretation of the meaning and evolution of the Grand Axis in Paris. This paper analyses the work presented by the artist from an urban planning perspective. It shows how the rich and multi-layered metaphor for the 21st-century...
-
Selected problems of sensitivity and reliability of a jack-up platform
PublikacjaThe paper deals with sensitivity and reliability applications to numerical studies of an off-shore platform model. Structural parameters and sea conditions are referred to the Baltic jack-up drilling platform. The study aims at the influence of particular basic variables on static and dynamic response as well as the probability of failure due to water waves and wind loads. The paper presents the sensitivity approach to a generalized...
-
On the preestimation technique and its application to identification of nonstationary systems
PublikacjaThe problem of noncausal identification of a nonstationary stochastic FIR (finite impulse response) sys- tem is reformulated, and solved, as a problem of smoothing of preestimated parameter trajectories. Three approaches to preestimation are critically analyzed and compared. It is shown that optimization of the smoothing operation can be performed adaptively using the parallel estimation technique. The new approach is computationally...
-
Advanced methods in biosensing: fundamentals and applications
Kursy OnlineThis course provides instruction in the basic science and engineering conceptsrequired to understand the design and application of biosensors. Different biosensorsystems are explored, ranging from electrochemical devices, through to optical orthermal systems. Instruction is also given in the general principles of sampling andanalysis, statistical presentation and manipulation of data. The primary focus will bethe physics of biomolecule...
-
Damage-Involved Structural Pounding in Bridges under Seismic Excitation
PublikacjaDuring severe earthquakes, pounding between adjacent superstructure segments of highway elevated bridges was often observed. It is usually caused by the seismic wave propagation effect and may lead to significant damage. The aim of the present paper is to show the results of the numerical analysis focused on damage-involved pounding between neighbouring decks of an elevated bridge under seismic excitation. The analysis was carried...
-
Anticancer Imidazoacridinone C-1311 is Effective in Androgen-Dependent and Androgen-Independent Prostate Cancer Cells
PublikacjaAndrogen receptor (AR) plays a crutial role in prostate cancer (PCa) development and metastasis. Here, we reported potent anti-PCa activity of a small molecule imidazoacridinone C-1311. In AR-positive PCa cells, C-1311 was found to inhibit the transcriptional activity of AR uncovering a novel mechanism that may be relevant for its anticancer effect. Mechanistically, C-1311 decreased AR binding to prostate-specific antigen (PSA)...
-
c-Myc Protein Level Affected by Unsymmetrical Bisacridines Influences Apoptosis and Senescence Induced in HCT116 Colorectal and H460 Lung Cancer Cells
PublikacjaUnsymmetrical bisacridines (UAs) are highly active antitumor compounds. They contain in their structure the drugs previously synthesized in our Department: C-1311 and C-1748. UAs exhibit different properties than their monomer components. They do not intercalate to dsDNA but stabilize the G-quadruplex structures, particularly those of the MYC and KRAS genes. Since MYC and KRAS are often mutated and constitutively expressed in cancer...
-
Exploring multi-step glucose oxidation kinetics at GOx-functionalized nanotextured gold surfaces with differential impedimetric technique
PublikacjaFor a few past years, we can observe the enormous growth of investigations related to ultrasensitive electrochemical sensors capable of reliable determination of important body parameters and analytes. Utilized procedures rely on standard electrochemical methods, demanding electrode polarization, and information about the initial characteristics of the working electrode. More and more complex electrode materials are characterized...
-
Light-improved glucose sensing on ordered Au-Ti heterostructure
PublikacjaNon-enzymatic electrochemical platforms sensitive towards glucose presence have attracted a worldwide attention during last decades. We report on influence of solar light onto response of gold-titanium heterostructures prepared via controllable approach. The material based on Au nanoparticles orderly distributed over the structured titanium foil was obtained by electrochemical anodization followed by chemical etching, magnetron...
-
Rozprzestrzenianie się w podtorzu skutków katastrof kolejowych z udziałem materiałów niebezpiecznych
PublikacjaDuża część przewozów materiałów niebezpiecznych prowadzona jest koleją. W związku z tym bezpieczeństwo tych przewozów nabiera coraz większego znaczenia. Każda katastrofa z udziałem materiałów niebezpiecznych ma negatywny wpływ na uczestników tego zdarzenia oraz na otaczające środowisko, bowiem jej zasięg na ogół nie jest lokalny. Z tego wynika, że w przypadku zaistnienia katastrofy należy minimalizować jej skutki oraz w dalszych...
-
Analiza sterowania ułamkowego PIλDμ mocą reaktora jądrowego
PublikacjaW artykule przedstawiono syntezę regulatora PIλDμ niecałkowitego rzędu dla potrzeb sterowania mocą reaktora jądrowego lekko wodnego określanego, jako typu PWR (Pressurized Water Reactor). W tym celu wykorzystano nieliniowy model matematyczny reaktora PWR o parametrach skupionych obejmujący procesy generacji i wymiany ciepła oraz termicznych efektów reaktywnościowych. Nastawy regulatora PIλDμ niecałkowitego rzędu dobrano w sposób...
-
Chemorezystancyjny czujnik gazu na bazie polimeru przewodzącego PEDOT
PublikacjaPolimery przewodzące, takie jak Poli(3,4-etylenodioksytiofen) (PEDOT) są atrakcyjnymi materiałami elektrodowymi, które posiadają takie zalety, jak biokompatybilność, duża przewodność i elastyczność. Elektroprzewodzące polimery można otrzymać w wyniku chemicznej polimeryzacji lub elektropolimeryzacji. W niniejszej pracy przedstawiono zostanie koncepcja czujnika gazów składająca się z elektrody grzebieniowej oraz polimeru przewodzącego...
-
The surface of the sensor used in the analysis of odorous substances
Dane BadawczeHuman industrial activity usually leads to smaller or larger interference with the ecosystem, contributing to changes affecting the quality of life. An example may be the emission of gaseous substances, not necessarily toxic, but due to their intense smell, they can cause discomfort to people exposed to their inhalation. The problem is so important...
-
Mesoscopic impedance analysis of solid materials surface
PublikacjaSeveral techniques have been developed in order to characterize electrical properties of surfaces in micrometer/nanometer scale. Obtaining of the spatial distribution of sample resistance, capacitance or potential requires separate measurements performed in different scanning modes. On the other hand, analysis of the frequency response of investigated system enables determination of several physical quantities in single measurement...
-
Testing the impact of simplifications adopted in models describing wave loads on ship
PublikacjaThe wave-ship system in naval architecture is generally assumed to be a linear one. This allows for the computation of a transfer function of ship response to waves including wave loads on ship. The transfer function and the wave spectral density function enable the development of the stochastic process of wave loads on ship, corresponding to the irregular wave generating that loads. If the mathematical models of wave load transfer...
-
A testing method of analog parts of mixed-signal electronic systems equipped with the IEEE1149.1 test bus
PublikacjaA new solution of the JTAG BIST for testing analog circuits in mixed-signal electronic microsystems controlled by microcontrollers and equipped with the IEEE1149.1 bus is presented. It is based on a new fault diagnosis method in which an analog circuit is stimulated by a buffered signal from the TMS line, and the time response of the circuit to this signal is sampled by the ADC equipped with the JTAG. The method can be used for...
-
Tuftsin-Properties and Analogs
PublikacjaImmunomodulation is one of the significant therapeutic strategies. It includes both stimulation or suppression of the immune system by a variety of substances called immunomodulators, designed to regulate the immune response of the organism to infections of varying etiology. An example of such a substance is tuftsin (TKPA) 3 (Fig. (1)). Tuftsin is an endogenous immunomodulator of a wide spectrum of biological activity. Tetrapeptide...
-
Testing the impact of simplifications adopted in models describing wave loads on ship
PublikacjaThe wave-ship system in naval architecture is generally assumed to be a linear one. This allows for the computation of a transfer function of ship response to waves including wave loads on ship. The transfer function and the wave spectral density function enable the development of the stochastic process of wave loads on ship, corresponding to the irregular wave generating that loads. If the mathematical models of wave load transfer...
-
Fitting the mobile device characteristics to the user's hearing preferences
PublikacjaA method for fitting the mobile computer audio characteristics to the user's hearing preferences is proposed. The process consists of two stages: calibration and dynamics processing. During the calibration phase the user performs a loudness scaling test giving their response regarding the perceived loudness. The dynamics processing made on above basis sets the loudness to the most comfortable level. The processing accounts both...
-
Fast Multi-Objective Antenna Design Through Variable-Fidelity EM Simulations
PublikacjaA technique for fast multi-objective antenna optimization is introduced. A kriging interpolation surrogate constructed from sampled coarse-mesh EM simulations is utilized by multi-objective evolutionary algorithm (MOEA) to obtain the initial Pareto front approximation. The surrogate is defined in a subset of the original design space, determined by means of independently optimized individual objectives. Response correction techniques...
-
Intergranular Corrosion Detection Using Electromagnetic Transducers for Ultrasonic Testing
PublikacjaThe aim of this paper is to create a research methodology that allows a quick analysis of the structural state of high alloy austenitic steels using non-destructive ultrasonic tests, in contrast to destructive standard methods. Electromagnetic acoustic transducers (EMAT) are used to generate and receive the ultrasonic wave and detect the microstructural changes caused by sample sensitization in elevated temperature, even after...
-
A New Expression for the 3-D Dyadic FDTD-Compatible Green's Function Based on Multidimensional Z-Transform
PublikacjaIn this letter, a new analytic expression for the time-domain discrete Green's function (DGF) is derived for the 3-D finite-difference time-domain (FDTD) grid. The derivation employs the multidimensional Z-transform and the impulse response of the discretized scalar wave equation (i.e., scalar DGF). The derived DGF expression involves elementary functions only and requires the implementation of a single function in the multiple-precision...
-
Effect of electrode resistance on admittance spectra of planar organic device carrying SCLC and on charge carrier mobility extracted from susceptance
PublikacjaThe work presents small signal admittance spectra of a sandwich system with thin organic layer carrying a space charge limited current. The effect of series resistance of electrodes on the spectra is discussed. Spectra of small signal capacitance are added to get more detailed insight. The analysis performed shows that the series resistance can affect both parts of small signal response within a whole range of frequency. Moreover,...
-
Reliability assessment of truss towers using Monte Carlo Method, PEM and RSM
PublikacjaThe paper discusses reliability assessment of simple random truss structures using three different probabilistic methodologies: the Monte Carlo Method (MCM), the Point Estimate Method (PEM) and the Response Surface Method (RSM). A benchmark truss structure and a simplified full–size engineering tower are both analyzed. A set of ultimate load numerical calculations is performed and the results are taken as the basis of advanced...
-
Measurement Stand and Methodology for Research of the Off-Body and Body-to-Body Radio Channels in WBANs with Different Diversity Schemes
PublikacjaThe concept of an experimental test bed for system loss and channel impulse response measurements for off-body and body-to-body radio channels in wireless body area networks (WBANs) is fully described. The possible measurement scenarios that may occur in investigation of off-body and body-to-body channels are classified and described in detail. Additionally, an evaluation is provided of the standard and expanded uncertainties of...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #3.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA, experiment run #3The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #5.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA, experiment run #5.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,8 V at 241 mA. Sample 24, run #1.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,8 V and discharged to 10 mV by constant current 241 mA, experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 250 mA. Sample 24.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 250 mA. Last experiment with sample 24The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 2
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,5 V at 180 mA. Sample 24
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,5 V and discharged to 10 mV by constant current 180 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Simultaneous measurements of ECG, body Impedance and temperature
Dane BadawczeThe data are complementary part of the experiment designed to demonstrate how to use the network protocols to transmit medical data. The dataset contains biomedical signals of ECG, Impedanc and temperature acquired simultaneously. The data allow students to become familiar with data acquisition methods (simulate data transmission by medical device over...
-
Distance measurement by the low coherent interferometer
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1560 nm, an optical spectrum analyzer and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 80 mA. Sample 41.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 80 mA. Sample 41.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #2.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA, experiment run #2The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 250 mA. Sample 23, run #1.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 250 mA. Sample 23, experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,8 V at 241 mA. Sample 24, run #2.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,8 V and discharged to 10 mV by constant current 241 mA, experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,8 V at 241 mA. Sample 24, run #3.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,8 V and discharged to 10 mV by constant current 241 mA, experiment run #3.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 24h exposition
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,9 V at 241 mA. Sample 24, run #1.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,9 V and discharged to 10 mV by constant current 241 mA, experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,5 V at 241 mA. Sample 24
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,5 V and discharged to 10 mV by constant current 241 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 250 mA. Sample 23, run #2.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 250 mA. Sample 23, experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...