Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublicationOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...
-
Impact of thermal backfill parameters on current-carrying capacity of power cables installed in the ground
PublicationProper design of power installations with the participation of power cables buried in homogeneous and thermally well-conductive ground does not constitute a major problem. The situation changes when the ground is non-homogeneous and thermally low-conductive. In such a situation, a thermal backfill near the cables is commonly used. The optimization of thermal backfill parameters to achieve the highest possible current-carrying capacity...
-
CFD-based evaluation of current-carrying capacity of power cables installed in free air
PublicationEvaluation of current-carrying capacity of power cables and selection of cross-sectional area of their conductors are mainly performed in accordance with requirements of EN, IEC or IEEE standards. However, these standards do not provide all methods of cables installation and location which occur in practice. Thus, in some cases, performance of advanced modeling of various thermal phenomena, affecting power cables current-carrying...
-
Effect of solar radiation on current-carrying capacity of PVC-insulated power cables – the numerical point of view
PublicationPower cables are usually buried in the soil, which results in their relatively high current-carrying capacity. However, there are cases in which the starting/final section of a cable line runs along a pole of an overhead power line. Power cables can be directly exposed to solar radiation then, and this negatively influences their current-carrying capacity as well as estimated life of the cables’ insulation. An analysis of thermal...
-
Load carrying capacity of the eccentric joint in the truss made of open cross-sections
PublicationThe influence of eccentricity at intersections of truss members on the load carrying capacity of the truss joint is presented in the paper. The research truss elements were designed as cold-formed open cross section. Analytical calculations, numerical analysis and experimental research were conducted to reveal how the eccentricity affects the effort of material in the joint area. The results of analysis and investigations are compared...
-
Parametrical Method for Determining Optimal Ship Carrying Capacity and Performance of Handling Equipment
PublicationThe paper presents a method of evaluating the optimal value of the cargo ships deadweight and the coupled optimal value of cargo handling capacity. The method may be useful at the stage of establishing the main owners requirements concerning the ship design parameters as well as for choosing a proper second hand ship for a given transportation task. The deadweight and the capacity are determined on the basis of a selected economic...
-
Experimental method to evaluate the load-carrying capacity of double corrugated sheet profiles
Publication -
ANALYSIS OF THE LOAD-CARRYING CAPACITY OF A HYDRODYNAMIC WATER-LUBRICATED BEARING IN A HYDROELECTRIC POwER PLANT
PublicationThe paper presents an analysis of the load-carrying capacity of a historic hydrodynamic water-lubricated radial bearing of an unconventional segment design installed in the Braniewo Hydroelectric Power Plant. The aim of the calculations was to determine whether the bearing operates in the conditions of hydrodynamic or mixed lubrication, as well as to establish the optimal geometry of the axial grooves allowing for the highest load-carrying...
-
Influence of local bush wear on water lubricated sliding bearing load carrying capacity
PublicationOne of main problems concerning water-lubricated bearings is their durability. There are known cases of bearings with life time measured in decades, and some, whose refurbishment was necessary just days after start-up. Obtaining stable fluid film friction plays key role in the durability of these bearings. Unfortunately, their load-carrying capacity is limited due to water's low-viscosity. The conducted experimental...
-
The influence of reinforcement on load carrying capacity and cracking of the reinforced concrete deep beam joint
PublicationThe paper presents the results of experimental research of the spatial reinforced concrete deep beam systems orthogonally reinforced and with additional inclined bars. Joint of the deep beams in this research was composed of the longitudinal deep beam with a cantilever suspended at the transversal deep beam. The cantilever deep beam was loaded throughout the depth and the transversal deep beam was loaded at the mid-span by longitudinal...
-
Load-carrying capacity of axially loaded concrete-filled steel tubular columns made of thin tubes
PublicationAn experimental investigation was conducted on 30 CFST columns. An influence of the following factors on load-carrying capacity of the investigated columns was analyzed: the column slenderness (l1 = 42, l2 = 27 and l3 = 15), the tube thickness (the reinforcement ratio was equal to 4% or 6%), the way of applying the load to CFST columns (through the concrete core or through the entire cross-section), the bond strength between a...
-
Analysis of load carrying capacity and destruction mechanism of an intermediate anchorage steel plate for pillar jib crane
PublicationPillar jib cranes are often mounted to existing floors with the use of an intermediate anchorage steel plate instead of using independent foundations, what is shown in the figure. Standards for steel design provide only basic rules for the design of such an intermediate plate. This study presents a simple design approach by using a numerical model in order to analyze different parameters that have significant influence in the anchorage...
-
Load-carrying capacity and state of effort of tubes made of glass and basalt fibre reinforced polymer filled with concrete
PublicationOpisano badania eksperymentalne słupów wykonanych z rur polimerowych zbrojonych włóknami szklanymi i bazaltowymi. Część rur wypełniano wewnątrz betonem. Słupy z wypełnieniem niszczyły się w sposób powolny, wykazując wysoką nośność pokrytyczną, podczas gdy słupy z rur pustych niszczyły się w sposób gwałtowny, niesygnalizowany. Nośności uzyskane eksperymentalnie porównano do nośności obliczonych teoretycznie na podstawie procedur...
-
Design of power cable lines partially exposed to direct solar radiation – special aspects
PublicationPower cable lines are usually buried in the ground. However, in some cases, their ending sections are mounted along the supports of overhead lines. This leads to a situation where the cables are exposed to direct solar radiation and, consequentially, overheat. The paper presents the advanced computer modelling of power cables’ heating, considering their insolation as well as the effect of wind. The temperature and current-carrying...
-
Overheating of underground power cable line due to its partial exposition to solar radiation
PublicationCurrent-carrying capacity of underground power cable lines depends, among others, on thermal resistivity of the soil and cables layout: trefoil formation, flat formation with or without spacing. If conditions for heat transfer in the ground are favorable, the current-carrying capacity is relatively high. Therefore, it generates risk of the power cables overheating, if part of the cable line is located vertically in the air, to...
-
Higher harmonics produced by traction substations – computer modelling and experimental verification
PublicationVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers, although the rms value of load current does not exceed their current-carrying capacity. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion...
-
Numerical and experimental investigation of thermal convection near electric devices with vertical channels
PublicationThis paper presents the results of numerical and experimental investigation of thermal convection near heat emitting surfaces of an electric device. For the intensification of thermal convection, special vertical channels were formed near the heat emitting surfaces of the device. An experimental test has proved that there is an optimal length of the channels – thermal convection is the most intensive then. Air velocity vectors...
-
The Laboratory Stand for the Evaluation of Heat Dissipation from the Power Cable in a Casing Pipe
PublicationThe current carrying capacity of a power cable determines its efficiency, which depends on its capability to dissipate heat produced inside the cable, as a result of current flow, into the surrounding. The studies were conducted to determine how the characteristics of the medium around the cable affected its temperature and, as a result, its ability to transport electricity. The experimentation in the lab and real measurements...
-
Heat Dissipation from the Power Cable in the Casing Pipe
PublicationThe current carrying capacity of a power cable determines its ability to carry a specific current and is related to the efficiency of dissipation of heat generated in the cable laid in a specific environment. The studies were conducted in order to determine how the characteristics of the medium around the cable affected its temperature, and thus the ability of the cable to transmit electricity. The experimentation in the lab and...
-
Evaluation of overstrength-based interaction checks for columns in steel moment frames
PublicationCurrent design guidelines in the United States require a check for only column axial force under overstrength seismic loads for capacity-designed steel moment frames. A study is presented to examine the implications of this guidance, which disregards the column interaction check (including both axial force and moment) under overstrength seismic loads. A set of thirteen steel moment frames are designed using multiple rules that...
-
Wpływ ukształtowania zbrojenia na zarysowanie i nośność żelbetowego węzła tarczowego ze wspornikiem
PublicationPraca ma charakter eksperymentalno-teoretyczny i dotyczy zagadnień związanych z żelbetowymi tarczami pracującymi w przestrzennym układzie konstrukcji budynków. Celem niniejszej dysertacji było określenie wpływu głównych parametrów jakimi są sposób ukształtowania zbrojenia i smukłość ścinania na zarysowanie i nośność żelbetowego przestrzennego węzła tarczowego ze wspornikiem. Na podstawie aktualnego stanu wiedzy, opracowano program...
-
Experiment-Based Study of Heat Dissipation from the Power Cable in a Casing Pipe
PublicationThe paper deals with the important challenges in terms of electricity transmission by means of underground cable lines. The power cable’s performance is characterized by an ampacity that represents its maximum electric current-carrying capacity. The ampacity of power cables depends on their ability to diffuse the heat generated by the current flow into the environment. In the performed research, the analysis of the efficiency of...
-
Improving performance of large thrust bearings through modeling and experimentation
PublicationLarge thrust bearings are highly loaded machine elements and their failures cause serious losses. Start ups and stoppages of the bearing under load are specially critical regimes of operation. Load carrying capacity depends on the profile of the oil gap. In transient states this profile is also changing. In the design of large thrust bearings minimizing thermo-elastic deformations is an important goal, which can be accomplished...
-
Influence of nodes with positive eccentricity on load-carrying capasity of truss' top chords in trusses made of welded cold-formed members.
PublicationIn order to establish the influence of eccentric crossing of truss members on the load-carrying capacity of the folded chord of a hat-section truss, a research model was created and preliminary numerical analysis of the truss was performed with the use of Marc Mentat programme. Distorial instability of crossheads caused by deviation of loose (unmounted) channel section web’s bends was observed. Due to the slenderness of the section’s...
-
Implementacja pomierzonych imperfekcji geometrycznych powłokicylindrycznej do modelu obliczeniowego
PublicationThis paper presents the method of implementation of the geometrical imperfections used by the author during the experimental and numerical research into the load-carrying capacity of cylindrical steel shells subjected to uniform circumferential compression.
-
Effect of electrode resistance on admittance spectra of planar organic device carrying SCLC and on charge carrier mobility extracted from susceptance
PublicationThe work presents small signal admittance spectra of a sandwich system with thin organic layer carrying a space charge limited current. The effect of series resistance of electrodes on the spectra is discussed. Spectra of small signal capacitance are added to get more detailed insight. The analysis performed shows that the series resistance can affect both parts of small signal response within a whole range of frequency. Moreover,...
-
Structural Reliability Assessment Of Corroded Tanker Ship Based On Experimentally Estimated Ultimate Strength
PublicationThis work deals with the reliability assessment of a tanker ship hull structure subjected to a vertical bending moment and corrosion degradation. The progressive collapse and ultimate load carrying capacity are estimated based on experimentally tested scaled box-shaped-specimens. The translation of the strength estimate of the scaled specimen to the real tanker ship hull structure is performed based on the dimensional theory developing...
-
Moment resistance of I-section end-plate roof girder splices; a case study
PublicationThis article deals with the problem of determining the resistance of end-plate connections. A nonlinear FEM model of the joint was constructed in order to predict its carrying capacity. A standard code procedure was done as well. The analyses have been done to assess atypical end-plate joints designed and constructed as a part of roof structures.
-
Concrete-filled FRP tubular members in marine and bridge structures
PublicationConcrete core of the concrete-filled tubes (CFTs) with circular cross-section is in the case of an axial compression subjected to a spatial state of compressive stresses. This state leads to enhancement in the concrete strength. The enhancement is utilized in Eurocode 4 design procedures for CFSTs (i.e. CFTs with tube made of steel). The structural design of CFFTs (i.e. CFTs with tube made of Fibre Reinforced Polymer - FRP) is...
-
Safety issues referred to induced sheath voltages in high-voltage power cables – case study
PublicationLoad currents and short-circuit currents in high-voltage power cable lines are sources of the induced voltages in the power cables’ concentric metallic sheaths. When power cables operate with single-point bonding, which is the simplest bonding arrangement, these induced voltages may introduce an electric shock hazard or may lead to damage of the cables’ outer non-metallic sheaths at the unearthed end of the power cable line. To...
-
TRUSS JOINT WITH POSITIVE ECCENTRICITY EXPERIMENTAL RESEARCH
PublicationDue to the technological reasons in modern lightweight steel trusses, fabricated from cold- formed sections, positive eccentricities appear in the truss nodes what induce additional forces in the truss chords. To account for the real load-carrying capacity of truss node area the steel structure research in scale 1:1 were conducted. The experiments consisted of two parts: preliminary and proper one, when conclusions from...
-
STABILITY AND LOAD BEARING CAPACITY OF A BARS WITH BUILT UP CROSS SECTION AND ELASTIC SUPPORTS
PublicationThe present paper is devoted to the numerical analysis and experimental tests of compressed bars with built–up cross section which are commonly used as a top chord of the roof trusses. The significant impact on carrying capacity for that kind of elements in case of out-of-plane buckling is appropriate choice of battens which are used to provide interaction between separate members. Linear buckling analysis results and nonlinear static...
-
O modelowaniu numerycznym dźwigarów zespolonych
PublicationThe paper is a general review of theoretical problems and corresponding numerical procedures actually available in commercial engineering software. Several possibilities of numerical simulation for composite girders are presented. Effectivity of meshing is showed on the simple example. Finally several examples of structural numeric models for real bridges are included. In the author's opinion, presented available procedures for...
-
Wpływ drążenia pionowego w silikatowych elementach murowych na nośność kotew wklejanych
PublicationThe article is showing results of measurements of the effectiveness of the assembly anchor of inmates glued in in sunk vertically lime-sandy blocks. Examinations were performed for cases of the assembly anchor in different fragments of blocks: in part fullwall, in an axis of symmetry and on the edge of the aperture vertical. An influence of the location of places of settling was examined anchor to the way of the forming of uniting...
-
Discrete random variables in reliability calculations of a reticulated shell
PublicationImplementation of the Point Estimation Method (PEM) in the reliability analysis of a three-dimensional truss structure is presented in the paper. The influence of geometric and material random parameters on the truss load-carrying capacity was investigated. The analysis was performed for different combinations of basic variables. Symmetric and asymmetric cases of snow load were taken to assess the structural reliability. Sensitivity...
-
Increasing the lifetime of engineering structures through the use of composite laggings
PublicationThe use of composite laggings prevents concrete (chemical and biological) corrosion. Columns coated with composite or reinforced composite are more resistant to negative environmental impact on concrete or steel. The mechanical properties of the reinforced casing also cause that these types of columns are more resistant to lateral forces. The applied casing limits carbonization of concrete and cyclical freezing and thawing with...
-
The validation process of truss model with joint eccentricities
PublicationNowadays, due to the technological reasons in modern lightweight steel trusses, fabricated from cold-formed sections, positive eccentricities appear in the truss nodes, to induce additional forces truss chords. In order to account for the real load-carrying capacity of truss node area the steel structure research was conducted in scale 1:1. As a result of experimental research, the forms of deformation and strains of the walls...
-
Search for the most useful geometry of an acoustic journal bearing
PublicationComputer simulations of a number of journal bearing’s geometries utilising acoustic levitation were carried out. The choice of the best geometry depended on the ability of a deformed shape, created by piezo-electric elements, to facilitate squeeze film ultrasonic levitation, and also to create three evenly distributed diverging aerodynamic gaps. Deformations of analysed variants of the bearing’s shape were generated by numerical...
-
Modelowanie kratownicy z kształtowników giętych na zimno z mimośrodami dodatnimi w węźle = Modelling of truss with cold-formed section and positive eccentricyty in the node.
PublicationThe topic of this research is establishing load-carrying capacity of compressed and tensed chords of trusses made of cold-formed open cross-sections. Occurrence of bending in the truss’ chord is the result of specific production technology assumed by the designer and producer of lattice girder’s systems. The aim of this research is to present methodology of conduct while creating numerical models that best depict the behaviour...
-
Experimental study of the post tensioned prestressed concrete corbels
PublicationThe results of experimental investigation of 6 symmetrical double prestressed corbels of variable shear span to depth ratio and variable location of prestressing bars are presented in the paper. The post ten- sioned corbels were prestressed with Macalloy 1030 bars of 25 mm in diameter. The results of the tests were compared with the cracking and load carrying capacity of corbels reinforced with passive reinforce- ment. As a result...
-
Modeling of truss with cold-formed section and positive eccentricity in the node
PublicationThis work is dedicated to establishing the load carrying capacity of tensed and compressed truss’ nodes made of cold-formed open cross sections. The occurrence of bending in the truss’ nodes is the result of a specific production technology for system lattice girders assumed by the designer and the producer. The aim of this research is to present the methodology of conduct for creation of computational models that best depict the...
-
Starch–metal complexes and metal compounds
PublicationRecently, metal derivatives of starch evoked considerable interest. Such metal derivatives can take a form of starch compounds bearing metal atoms and metal carrying moieties either covalently bound or complexed. Starch metal complexes may have a character of either Werner, inclusion, sorption or capillary complexes. In this publication, preparation, structure, properties and numerous current and potential applications of those...
-
Wpływ imperfekcji geometrycznych na bezpieczeństwo montażu i naprawy zbiorników cylindrycznych metoda podbudowy
PublicationW pracy zajęto się wyznaczeniem nośności granicznej zbiorników stalowych o osi pionowej montowanych lub naprawianych z zastosowaniem hydraulicznego systemu podnoszenia konstrukcji. Podniesiony zbiornik jest szczególnie narażony na utratę stateczności, a obciążenie wiatrem utrudnia prowadzenie prac. Jakiekolwiek deformacje blach, szczególnie w pobliżu zamocowań podnośników mogą w znacznym stopniu obniżyć obciążenie krytyczne konstrukcji....
-
Uncertainty assessment of ultimate strength of corroded stiffened plates subjected to different maintenance actions
PublicationThe study deals with the uncertainty assessment of different governing factors related to the ultimate strength of the corroded stiffened plates. The load-carrying capacity is predicted with the use of the nonlinear Finite Element Method. The most influencing governing factors in the non-linear FE analysis, such as material properties and initial imperfections are modeled and analysed as stochastic variables. The ultimate strength...
-
Zmodernizowany most Łazienkowski w Warszawie – analizy z wykorzystaniem modelu numerycznego MES
PublicationW artykule przedstawiono proces modelowania statycznego przęseł mostu Łazienkowskiego w Warszawie, który został poddany odbudowie po pożarze 14 lutego 2015 r. Sprawdzające obliczenia numeryczne wykonano w związku z badaniami konstrukcji podczas próbnego obciążenia. Przeprowadzono weryfikację obliczeń projektowych i zaprojektowano próbne obciążenie. Podsumowano wyniki analizy i badań. Dodatkowo opisano nową, stalową konstrukcję...
-
Intelligent microbearing project with memory of stress-strain history
PublicationTaking into account the increasing need of intelligent micro-bearing with memory, this paper presents the optimization, simulation and practical application of operating parameters(load carrying capacity, friction forces, friction coefficient, wear), simulation for hydrodynamic HDD micro-bearing with curvilinear nano-grooved journal profile. One of the reason of such journal profile is that this journal profile contributes to the...
-
Tribological model of porous bearings with particular attention given to the lubricant lubricity
PublicationThe friction and wear problems, accompanying all the tribological systems, lead to reduced service life. In order to prevent such situation, it is necessary to maintain fluid friction, which improves durability of all friction nodes in a tribological system. In the paper, the tribological system consists of porous bearings and the model deals with their weakest spots - the oil outflow points in the porous wall. A kinetic model...
-
Mechanical Properties of Aluminium Bracket Strengthening
PublicationThe aim of the research is laboratory investigation of aluminium brackets employed to fasten lightweight curtain walls to building facilities. Tensile loads perpendicular to end plates (vertical) were applied here. The author focused on the solutions intended to increase the load-carrying capacity of aluminium brackets applying the plain washer form A (DIN 125; ISO 7089), plain washer with an outer diameter about 3d (DIN 9021;...
-
Experimental research on a hydrodynamic thrust bearing with hydrostatic lift pockets: Influence of lubrication modes on bearing performance
PublicationThe aim of the study is to investigate the performance of a thrust bearing equipped with hydrostatic lift pockets under different lubrication modes. Three types of flat land bearing lubrication modes are studied experimentally: hydrostatic lubrication (HS; forced oil injection to the pockets), hybrid lubrication (HS + HD; hydrostatic lubrication combined with the external forced bearing oil supply) and hydrodynamic lubrication...
-
Preliminary experimental research on stability of truss' joint with positive eccentricity
PublicationRecently, a very large interest in lightweight steel structures made from cold-formed sections has been noticeable. In the design practice, a large emphasis is put on rational shaping of both the thin-walled elements and constructions designed on them. The aim of this paper is to present the methodology for preparation of experimental research that model the behaviour of members in trusses made of cold-formed sections with positive...