Filters
total: 1260
filtered: 868
Search results for: sensors
-
Novel Complementary Multiple Concentric Split Ring Resonator for Reliable Characterization of Dielectric Substrates with High Sensitivity
PublicationAccurate characterization of dielectric substrates with high sensitivity remains an important challenge in a variety of industrial applications. This paper proposes an innovative strategy to address this challenge by developing and optimizing a unique Complementary Multiple Concentric Split Ring Resonator (CMC-SRR). The major goal is to propose a sensor design with increased sensitivity and reliability for dielectric characterization....
-
Highly Reliable Passive RFID-Based Inductor–Capacitor Sensory System Strengthened by Solvatochromism for Fast and Wide-Range Lactate Detection
PublicationA passive radio frequency-identification-based inductor-capacitor (LC) lactate sensory system with a specific dye-containing interdigitated capacitor (IDC) in which the sensing signal is amplified by the solvatochromic effect is proposed. When a lactate solution contacts the IDC of the LC lactate sensor, the capacitance of the IDC changes, changing the resonance frequency of the sensor. This changes the oscillation frequency of...
-
Polarization sensitive optical coherence tomography for technical materials investigation
PublicationZaprezentowano system optycznej tomografii koherentnej z analizą stanu polaryzacji światła. System umożliwia nieniszczące i bezkontaktowe badanie wewnętrznej struktury materiałów warstwowych. Przedstawiono zastosowaną metodę analizy stanu polaryzacji promieniowana wstecznie rozproszonego od badanego obiektu.
-
Polarization sensitive optical coherence tomography for technical materials investigation
Publication -
ALD thin ZnO layer as an active medium in a fiber-optic Fabry–Perot interferometer
Publication -
An ultrasonic obstacle detector based on phase beamforming principles
PublicationW artykule przedstawiono rezultaty prac nad ultradźwiękowym wykrywaczem przeszkód dla niewidomych. Opisano metodę lokalizacji przeszkód w oparciu o algorytm beamformingu fazowego. Zaprezentowano rezultaty badań przeprowadzonych nad prototypem urządzenia.
-
Designing a high-sensitivity dual-band nano-biosensor based on petahertz MTMs to provide a perfect absorber for early-stage non-melanoma skin cancer diagnostic
PublicationThe purpose of this study is development of a novel high-performance low-Petahertz (PHz) biosensor for non-melanoma skin cancer (NMSC) diagnosis. The presented device is designed to work within a microwave imaging regime, which is a promising alternative to conventional diagnostic methods such as visual examination, dermoscopy, and biopsy. The suggested biosensor incorporates a dual-band perfect absorber (operating bands at 0.909...
-
ALD thin ZnO layer as an active medium in a fiber-optic Fabry-Perot interferometer
Publication.
-
Radar Signal Parameters Estimation Using Phase Accelerogram in the Time-Frequency Domain
PublicationRadar signal parameter estimation, in the context of the reconstruction of the received signal in a passive radar utilizing other radars as a source of illumination, is one of the fundamental steps in the signal processing chain in such a device. The task is also a crucial one in electronic reconnaissance systems, e.g. ELINT (Electronic Intelligence) systems. In order to obtain accurate results it is important to measure, estimate...
-
Electrochemical detection of 4,4',5,5'-tetranitro-1H,1'H-2,2'-biimidazole on boron-doped diamond/graphene nanowall electrodes
PublicationWe present a promising approach to the electroanalytical detection of a specific nitroaromatic explosive in landfill leachates (LLs) that originated from a municipal solid waste plant. The paper is focused but not limited to the sensing of 4,4',5,5'-tetranitro-1H,1'H-2,2'-biimidazole (TNBI) using differential pulse voltammetry and cyclic voltammetry. Highly electroactive nanocarbon was applied to determine low concentrations of...
-
Qualitative and Quantitative Analysis of Selected Tonic Waters by Potentiometric Taste Sensor With All-Solid-State Electrodes
PublicationTaste sensor with five all-solid-state electrodes (ASSE) III (third version) was used for qualitative and quantitative analysis of selected tonic waters (J.Gasco, Kinley, Jurajski, Jurajski with citrus flavor, Carrefour, Schweppes Indian Tonic, and Schweppes Bitter Lemon). The results obtained by this taste sensor analyzed with principal component analysis, agglomerative hierarchical clustering methods show that this sensor can...
-
Spectroscopic wireless sensor of hematocrit level
PublicationAn optical method for hematocrit measurement is presented. The sensor, designed and developed by authors, consists of a spectroscopic set-up and a microcontroller. The work of the sensor is based on measurement of intensity of two selected spectral bands. Tests confirmed the ability of the sensor to determine the hematocrit level with appropriate measurement accuracy. Measurement results can be transmitted via wireless module to...
-
High-performance graphene-based biosensor using a metasurface of asymmetric silicon disks
PublicationIn recent years, optical biosensors widely applicable for medical applications, have received much attention. In this paper, we propose a high-performance polarization-insensitive optical biosensor based on a graphene-dielectric metasurface. The metasurface consists of an asymmetric dielectric disk array that supports a high Q-factor Fano resonance. The provided sharp Fano resonance results in an enhanced light-matter interaction...
-
Novel Complementary Resonator for Dielectric Characterization of Substrates Based on Permittivity and Thickness
PublicationThis paper presents a novel complementary resonator featuring high sensitivity, low fabrication cost, and improved performance. The proposed structure consists of a complementary concentric square and circular ring resonator (CCSCRR) with multiple splits to enhance the inductance of the resonator. The proposed CCSCRR is coupled to a microstrip transmission line with an impedance of fifty ohms to create a high-sensitivity sensor....
-
An NO2 sensor based on WO3 thin films for automotive applications in the microwave frequency range
PublicationA microwave system dedicated to the detection of nitrogen dioxide in the harsh environment of the Norway highways is proposed. An optimized transmission line type of sensor coated with a tungsten trioxide thin film that changes its electrical properties under NO2 gas exposure is developed. The sensors' response (S) is given in °/GHz and it is calculated based on wideband measurements. The advantage of wideband measurements in comparison...
-
Fluctuation-enhanced scent sensing using a single gas sensor
PublicationScent or aroma sensing during aromatherapy can be carried out by applying only a single resistance gas sensor (TGS - Taguchi Gas Sensors). This paper considers the efficiency of detection of essential oils by DC resistance and its fluctuations observed in TGS sensors. A detailed study has been conducted for scents emitted by five popular essential oils using three sensor types (TGS 2600, TGS 2602, TGS 823). The research was focused...
-
Enhanced gas sensing by graphene-silicon Schottky diodes under UV irradiation
PublicationThe effect of ultraviolet (UV) or blue irradiation on graphene/n-doped silicon Schottky junctions toward gas sensing was investigated. Schottky diodes were subjected to oxidizing nitrogen dioxide (NO2, 1–3 ppm) and reducing tetrahydrofuran (THF, 50–200 ppm), showing significantly different responses observed on the currentvoltage (I-V) characteristics, especially under UV light (275 nm). NO2 affected the resistive part of the forward region...
-
Oxygen biosensor based on carbon nanotubes directly grown on graphitic substrate
PublicationFilms of carbon nanotubes were synthesized on the graphitic substrates by CVD method in the presence of catalyst. Two different catalysts were used, that is nickel and iron, supported on graphitic substrates. The as-obtained nanotubes were analyzed by SEM imaging with EDX and Raman spectroscopy. The results revealed their multi-walled morphology. Free radical reaction was carried out in order to chemically functionalize synthesized...
-
Functional fluorine-doped tin oxide coating for opto-electrochemical label-free biosensors
PublicationSensors operating in multiple domains, such as optical and electrochemical, offer properties making biosensing more effective than those working in a single domain. To combine such domains in one sensing device, materials offering a certain set of properties are required. Fluorine-doped tin oxide (FTO) thin film is discussed in this work as functional optically for guiding lossy modes and simultaneously electrochemically, i.e....
-
Study of the NO2 sensing mechanism of PEDOT-RGO film using in situ Raman Spectroscopy
PublicationIn this work, the mechanism of the NO2 reaction with PEDOT-RGO composite film has been investigated via in situ Raman spectroscopy. Reduced graphene oxide (RGO), poly(3,4-ethylenedioxytiophene)-reduced graphene oxide (PEDOT-RGO) and poly(3,4-ethylenedioxytiophene)/ClO4− (PEDOT/ClO4−) films were fabricated using an electrodeposition method and used as resistance sensors of gaseous nitrogen dioxide. The experimental results indicate...
-
Effects of UV light irradiation on fluctuation enhanced gas sensing by carbon nanotube networks
PublicationThe exceptionally large active surface-to-volume ratio of carbon nanotubes makes it an appealing candidate for gas sensing applications. Here, we studied the DC and low-frequency noise characteristics of a randomly oriented network of carbon nanotubes under NO2 gas atmosphere at two different wavelengths of the UV light-emitting diodes. The UV irradiation allowed to sense lower concentrations of NO2 (at least 1 ppm) compared to...
-
Optical investigations of electrochemical processes using a long-period fiber grating functionalized by indium tin oxide
Publicationhe growing needs for fast and reliable sensing devices stimulate development of new technological solutions. In this work a new multi-domain sensing method is demonstrated where optical sensing device has been applied to enhance amount of data received during electrochemical analysis. Thin, optically transparent, high-refractive-index, and electrically conductive indium tin oxide (ITO) film was deposited using magnetron sputtering...
-
Impedimetric sensing of α-amino acids driven by micro-patterned 1,8-Diazafluoren-9-one into titania- boron- doped maze-like nanocarbons
PublicationThe development of impedimetric, non-faradaic label-free sensors for the detection of α-amino acids constitutes a trailblazing technology for the fast and inexpensive quantification of such biomarkers. Since α-amino acids, such as glycine and sarcosine, are basic constituents in biological processes, a variation in their concentration may be an indicator of cardiovascular diseases and metabolic disorders or neurological conditions....
-
Amperometric sensing of chemical oxygen demand at glassy carbon and silicon electrodes modified with boron-doped diamond
Publication.A boron-doped diamond (BDD) sensor is proposed for effective detection of chemical oxygen demand (COD) by means of amperometric technique. Boron-doped diamond thin films, acting as active sensors, were deposited on both silicon wafer and glassy carbon (GC) substrates by microwave plasma assisted chemical vapour deposition. SEM micrographs showed that BDD–Si displays triangle-faceted crystallites ca. 0.5–3 μm in size, while BDD–GC...
-
Multi-sensor monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in utility water installations
Publication -
Assessment of water quality based on multiparameter fiber optic probe
Publication -
Efficient reagent immobilization procedure for ion-sensitive optomembranes
Publication -
Application of optical fibres in oxidation-reduction titrations
Publication -
Amperometric sensing of chemical oxygen demand at glassy carbon and silicon electrodes modified with boron-doped diamond
Publication -
Metrological parameters of sulphur dioxide amperometric sensor containing addition of aprotic solvents
PublicationW publikacji zaprezentowano wyniki badań nad dodatku rozpuszczalnika aprotycznego do roztworu elektrolitu wewnętrznego czujnika na parametry metrologiczne prototypowego czujnika ditlenku siarki z membraną nafionową. Porównywano właściwości pięciu czujników różniących się składem elektrolitu. W każdym przypadku elektroda pracująca wykonana była ze złota, próżniowo napylonego na powierzchnię membrany. Roztwory elektrolitów zawierały...
-
Gold-modified paper as microfluidic substrates with reduced biofouling in potentiometric ion sensing
Publication -
Influence of aprotic solvent on a signal of an amperometric sensor with Nafion membrane
PublicationW pracy przedstawiono wyniki badań charakterystyk analitycznych amperometrycznego czujnika ditlenku siarki wyposażonego w mebranę nafionową i wypełnionego roztworami elektrolitów o różnej zawartości dimetylosulfotlenku. Ocenie poddany został wpływ zawartości DMSO w roztworze elektrolitu wewnętrznego czujnika oraz prędkości przepływu gazu na czułość czujnika i czas odpowiedzi na zmiany stężenia ditlenku siarki.
-
Nanocrystalline undoped ceria oxygen sensor.
PublicationW pracy przedstawiono wyniki badań struktury i elektrycznych właściwości nanokrystalicznego czujnika na bazie niedomieszkowanego tlenku ceru. Zbadano wpływ ciśnienia parcjalnego tlenu na rezystancję cienkowarstwowego tlenku ceru. Konduktancja tlenku ceru w zakresie stężeń tlenu od 10ppm do 100% ma charakter eksponecjalny z parametrem -0.25. Zbadano szybkość odpowiedzi oraz wpływ dwutlenku azotu oraz dwutlenku siarki na odpowiedź...
-
Pyrrole bearing diazocrowns: Selective chromoionophores for lead(II) optical sensing
PublicationDiazocrowns of 18-, 21- and 23-membered rings with pyrrole residue as a part of macrocycle were for the first time used as chromoionophores in lead(II) selective optodes. Sensing properties of optodes depend on the type of macrocycle, namely its size and the type of linker: oligoether or hydrocarbon chain. The best results were obtained for optode bearing 18-membered crown with oligoether linker showing linear response range of...
-
Enhanced susceptibility of SARS-CoV-2 spike RBD protein assay targeted by cellular receptors ACE2 and CD147: Multivariate data analysis of multisine impedimetric response
PublicationSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2) enters the cells through the binding of spike protein to the host cell surface-expressing angiotensin-converting enzyme 2 (ACE2) or by endocytosis mediated by extracellular matrix metalloproteinase inducer (CD147). We present extended statistical studies of the multisine dynamic electrochemical impedance spectroscopy (DEIS) revealing interactions between Spike RBD and...
-
Macrocyclic derivatives of imidazole as chromoionophores for bismuth(III)/lead(II) pair
Publication18-membered diazomacrocycles with imidazole or 4-methylimidazole residue as a part of macrocycle were used as chromoionophores in bismuth(III) and lead(II) dual selective optodes for the first time. Cellulose triacetate membranes doped with macrocyclic chromoionophores are bismuth(III) and lead(II) selective with color change from orange/red to different shades of blue and violet, respectively. Results obtained for model and real...
-
Synthesis and application of tetrazole di and triamide derivatives in ion-selective membrane electrodes
PublicationA number of tetrazole diamides and triamides have been synthesized and applied as ion carries in ion-selective membrane electrodes. Their selectivity and sensitivity were studied towards alkali, alkaline earth, transition and heavy metal cations. it was found that membranes doped with 3 and 2-nitrophenyl octyl ether exhibit an almost theoretial Nernstian response for NH+ over relatively wide concentration range. Elestrodes with...
-
Multi-sensor monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in utility water installations
PublicationThis paper presents an implementation of the monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in a utility water installation using an automated corrosion monitoring system. Due to the fact that the corrosion inhibitor was added to water intended for human consumption, it was necessary to build a multi-sensor monitoring system. In order to implement corrosion monitoring using a linear...
-
Fluctuation-enhanced scent sensing using a single gas sensor
PublicationWykrywanie zapachów podczas aromaterapii może być przeprowadzone za pomocą pojedynczego sensora gazów. W pracy rozważono efektywność detekcji zapachów olejków eterycznych za pomocą rezystancji DC oraz zjawisk fluktuacyjnych w tych sensorach, typu TGS2600,TGS2602,TGS823. Badania koncentrowały się na praktycznym zastosowaniu w aromaterapii do określania intensywności emitowanego zapachu. Opisano szczegółowo system do emisji zapachów.
-
Laser patterned platform with PEDOT–graphene composite film for NO2 sensing
PublicationThis work presents a simple and fully electrochemical route used for fabricating of a NO2 gas sensor made of reduced-graphene-oxide-poly(3,4-ethylenedioxythiophene) composite film. The sensing platform was fabricated from alumina substrate and equipped with gold interdigitated electrodes and built-in heater.The temperature distribution on the surface of interdigitated electrodes was investigated by a thermalimaging camera and compared...
-
A method to monitor urinary carbon dioxide in patients with septic shock
PublicationSevere sepsis and septic shock are life-threatening conditions with mortality rates exceeding 31% (Levy et al., 2012) [1]. Septicemia was the most expensive US hospital condition in 2011 (Torio and Andrews, 2006)[2]. Urinary carbon dioxide may provide rapid, clinically useful information about a patient’s status, empowering physicians to intervene earlier and improve septic shock mortality. The objective of this paper is to validate...
-
Solid-contact lead(II) ion-selective electrodes for potentiometric determination of lead(II) in presence of high concentrations of Na(I), Cu(II), Cd(II), Zn(II), Ca(II) and Mg(II)
PublicationLead and its compounds are a serious threat to the environment. Monitoring of this toxic heavy metal is a driving force for the continuous development of novel lead(II) ionophores to be applied in ion-selective electrodes. In this work a highly selective lead(II) ionophore, namely 25,26,27,28-tetrakis(piperidinylthiocarbonylmethylene)-p-tert-butylcalix[4]arene, was used in solid-contact ion-selective electrodes for determination...
-
Luminescence recognition material as an INHIBIT logic gate in presence of Pb2+ and Cu2+ ions in aqueous solutions
PublicationA recognition material consisting of silica xerogel with amino-modified surface selectively recognizes Pb2+ and Cu2+ (but only in presence of Pb2+ ions) in aqueous solutions of other metal ions. The analytical action of the material is based on a significant change in luminescence emission spectra of the material after chemisorption of Pb2+ ions. In the presence of Pb2+ in octahedral coordination environment, a new broad and strong...
-
Measurement of sub-nanometer molecular layers with ISFET without a reference electrode dependency
PublicationA new method of detection and measurement with sub-nanometer resolution of layers adsorbed or bonded to the ISFET's gate dielectric was presented. The sensitivity of this method is high enough to detect even partial mono-layer covering. The transconductance measurement of the ISFET provides independence of the output signal from pH changes and the driving electrode electrochemical potential instabilities. The stable reference electrode...
-
In-situ monitoring of electropolymerization processes at boron-doped diamond electrodes by Mach-Zehnder interferometer
PublicationIn this work, the Mach-Zehnder interferometer was designed to monitor the electrochemical processes conducted at boron-doped diamond electrode surface. The diamond electrodes were synthesized via Microwave Plasma-Assisted Chemical Vapor Deposition on optical grade quartz glass. The achieved transmittance in working are of diamond electrodes reached 55 %. A cage system-based Mach-Zehnder interferometer was used which allowed the...
-
The electrochemical determination of isatin at nanocrystalline boron-doped diamond electrodes: stress monitoring of animals
PublicationUltra-thin nanocrystalline boron-doped diamond electrodes (B:NCD) were used for the electrochemical determination of isatin in dog urine samples using cyclic voltammetry and square wave voltammetry in a phosphate buffer saline, pH = 7.2. No additional modification or pretreatment of the electrode surface was required in this approach, being of high importance for the facile detection procedure. The increase of the peak current...
-
Electrochemical performance of indium-tin-oxide-coated lossy-mode resonance optical fiber sensor
PublicationAnalysis of liquids performed in multiple domain, e.g., optical and electrochemical (EC), has recently focus significant attention. Our previous works have shown that a simple device based on indium-tin-oxide (ITO) coated optical fiber core may be used for optical monitoring of EC processes. At satisfying optical properties and thickness of ITO a lossy-mode resonance (LMR) effect can be obtained and used for monitoring of optical...
-
Advances in olfaction-inspired biomaterials applied to bioelectronic noses
PublicationAmong all the senses, olfactory system of mammals is the least characterised as far as the mechanisms of odour identification are concerned. The results of recent investigations allow better understanding of the operation mechanism of the sense of smell. Progress in this field is crucial for the development of sensor technology based on olfaction-inspired biomaterials, which simulate the olfactory system of the biological counterparts....
-
Efficient three-dimensional fluorescence measurements for characterization of binding properties in some plants
PublicationThe main aim of this research was to characterize some plants and to determine their similarities and differences, using spectroscopic methods. The interactions of soluble polyphenols of different plants with human serum albumin (HSA) were investigated by 3D-fluorescence. The obtained fluorescence results allow to classify the investigated plants according to their binding properties. The HSA-binding capacities of these plants...
-
Functionalized azobenzocrown ethers as sensor materials—The synthesis and ion binding properties
PublicationNew 13- and 16-membered azobenzocrown ethers with aromatic amino, amide, ether–ester or ether–amide residue in para position to an azo moiety were obtained. Acid–base properties and ion binding ability of the colored compounds were studied by spectroscopic methods: UV–vis, fluorimetry and 1H NMR spectroscopy. Selected azobenzocrowns were tested as ionophores in ion-selective membrane electrodes (ISEs) – classic and miniature all...