Filters
total: 394
filtered: 319
Chosen catalog filters
Search results for: REFERENCE ELECTRODE
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublicationThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
Properties of Nasicon-based CO2 sensor with Bi8Nb2O17 reference electrode
PublicationGas sensors are useful for the carbon dioxide concentration monitoring in many applications. The major challenge is to develop a potentiometric sensor working without the necessity of a reference gas and without a need of the reference electrode encapsulation. Important issue is a selection of reference electrode material, which should provide stable reference potential. For example as reference electrode material in sensor based...
-
Properties of Nasicon-based CO2 sensors with Bi8Nb2O17 reference electrode
PublicationPotentiometric CO2 sensors based on Nasicon (Na+ conductor, Na3Zr2Si2PO12) electrolyte, Bi8Nb2O17/Pt reference electrode and different sensing electrodes have been prepared. Besides the sensing electrode material, sensors differ from each other in the reference electrode preparation technique. The main aim of this study is to investigate sensor construction and electrode fabrication process influence on sensor properties. The optimal...
-
Measurement of sub-nanometer molecular layers with ISFET without a reference electrode dependency
PublicationA new method of detection and measurement with sub-nanometer resolution of layers adsorbed or bonded to the ISFET's gate dielectric was presented. The sensitivity of this method is high enough to detect even partial mono-layer covering. The transconductance measurement of the ISFET provides independence of the output signal from pH changes and the driving electrode electrochemical potential instabilities. The stable reference electrode...
-
Reference Electrodes with Ionic Liquid Salt Bridge: When Will These Innovative Novel Reference Electrodes Gain Broad Acceptance?
Publication -
Diagnosis of reference electrodes in cathodic protection systems by electrochemical impedance spectroscopy
PublicationPrzedstawiono wyniki badań laboratoryjnych i terenowych przeprowadzonych techniką elektrochemicznej spektroskopii impedancyjnej (EIS). Zaprezentowano widma impedancyjne następujących układów: elektroda odniesienia/elektroda pomocnicza; rurociąg/zakopane i przenośne elektrody odniesienia. Pokazano, że omawiana technika umożliwia badanie stanu technicznego elektrod odniesienia, co zwiększa pewność wyników pomiarów potencjału chronionej...
-
Tuning Electrochemical Performance by Microstructural Optimization of the Nanocrystalline Functional Oxygen Electrode Layer for Solid Oxide Cells
PublicationFurther development of solid oxide fuel cell (SOFC) oxygen electrodes can be achieved through improvements in oxygen electrode design by microstructure miniaturisation alongside nanomaterials implementation. In this work, improved electrochemical performance of an La0.6Sr0.4Co0.2Fe0.8O3-d (LSCF) cathode was achieved by the controlled modification of the La0.6Sr0.4CoO3-d (LSC) nanocrystalline interlayer introduced between a porous...
-
Influence of titanium layer on counter electrode on electrical parameters of DSSC
PublicationIn this paper the influence of the Ti layer thickness at counter-electrode on electrical parameters of DSSCs was examined. The transparent conductive oxide – less (TCO-less) counter electrodes (CE) with titanium layers and platinum as catalyst on Bk7 glass were prepared. Thin metallic films were deposited by means of magnetron sputtering (titanium) and Pulsed Laser Deposition (platinum). The counter electrode with Pt layer on Fluorine...
-
Simultaneous determination of Na+, K+, Ca2+, Mg2+ and Cl- in unstimulated and stimulated human saliva using all solid state multisensor platform
PublicationHuman saliva is one of the body fluids which collection method is relatively simple and non-invasive. The article is dedicated to assess concentration (activity) of Na+, K+, Ca2+, Mg2+ and Cl- in fresh, unstimulated or stimulated human saliva samples using single solid contact ion-selective electrodes with conventional reference electrode and self-made multisensor platform (MP) equipped with ion-selective membranes for Na+, K+,...
-
Influence of the internal electrolyte composition on amperometric sulphur dioxide sensor properties
PublicationIn this work amperometric sulphur dioxide sensor with a liquid electrolyte, a mercury sulphate reference electrode and solid polymer electrolyte (Nafion) covered with gold as a working electrode will be presented. The main goal of this research is to determine the influence of internal electrolyte composition on the sensor properties. Sensor filled with 1M and 5M sulphuric acid has been investigated.
-
Influence of the internal electrolyte composition on amperometric sulphur dioxide sensor properties
PublicationIn this work investigation of an amperometric sulphur dioxide sensor with a liquid electrolyte, a mercury sulphate reference electrode and solid polymer electrolyte (Nafion) covered with gold as a working electrode properties is presented. The main goal of this research is to determine the influence of internal electrolyte composition on the sensor properties. Sensor filled with 1M and 5M sulphuric acid has been studied.
-
Electrochemistry from first-principles in the grand canonical ensemble
PublicationProgress in electrochemical technologies, such as automotive batteries, supercapacitors, and fuel cells, depends greatly on developing improved charged interfaces between electrodes and electrolytes. The rational development of such interfaces can benefit from the atomistic understanding of the materials involved by first-principles quantum mechanical simulations with Density Functional Theory (DFT). However, such simulations are...
-
Application of electrochemical impedance spectroscopy to monitoring discharging process of nickel/metal hydride battery.
PublicationThis paper presents the possibility of applying impedance analysis to cell diagnostics. In order to obtain characteristic curves of both electrodes of a NiMH battery simultaneously, a reference electrode was added into the circuit. The authors analysed the cell under three cases, i.e. when its properties are determined only by the state of the positive electrode, only by the state of the negative electrode, or when both electrodes...
-
Improvement of Oxygen Electrode Performance of Intermediate Temperature Solid Oxide Cells by Spray Pyrolysis Deposited Active Layers
PublicationIntermediate temperature solid oxide fuel cells oxygen electrodes are modified by active interfacial layers. Spray pyrolysis is used to produce thin (≈500 nm) layers of mixed ionic and electronic conductors: Sm0.5Sr0.5CoO3−δ (SSC), La0.6Sr0.4CoO3−δ (LSC), La0.6Sr0.4Co0.2Fe0.8O3−δ (LSCF), and Pr6O11 (PrOx) on the electrode–electrolyte interface. The influence of the annealing temperature on the electrode polarization (area specific...
-
Construction and investigation of SO2 amperometric sensor with a solid polymer electrolyte membrane
Publicationn this paper a sensor for detection of the sulphur dioxide based on three electrode cell configuration with a liquid electrolyte, a mercury sulphate reference electrode and a solid polymer electrolyte working electrode is presented. Working elec- trode was obtained by using Takenaka-Torikai chemical deposi- tion method by precipitation of Au particles into the pores of the Nafion membrane. Sensors characteristics measurements were...
-
Biobatteries and biofuel cells with biphenylated carbon nanotubes
PublicationSingle-walled carbon nanotubes covalently biphenylated are used for the construction of cathodes in a flow biobattery and in flow biofuel cell. Zinc covered with a hopeite layer is the anode in the biobattery and glassy carbon electrode covered with bioconjugates of single-walled carbon nanotubes with glucose oxidase and catalase is anode of the biofuel cell. The potentials of the electrodes are measured vs. the Ag/AgCl reference...
-
Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
PublicationA new solid-contact potentiometric ion-selective electrode for the determination of SCN− (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included...
-
Electrodes array for contactless ECG measurement of a bathing person - a sensitivity analysis
PublicationAn applicability of a remote (contactless) electrocardiogram (ECG) measurements in a bathtub is presented in the paper. Possibility of ECG measurements in shallowly filled tube with a water was examined. A bathing person was, both, sitting and lying during experiments performed. The problem became non-trivial when the bathing person was moving in reference to a fixed set of electrodes and located at the longer walls of the bathtub....
-
The electrochemical determination of isatin at nanocrystalline boron-doped diamond electrodes: stress monitoring of animals
PublicationUltra-thin nanocrystalline boron-doped diamond electrodes (B:NCD) were used for the electrochemical determination of isatin in dog urine samples using cyclic voltammetry and square wave voltammetry in a phosphate buffer saline, pH = 7.2. No additional modification or pretreatment of the electrode surface was required in this approach, being of high importance for the facile detection procedure. The increase of the peak current...
-
Instantaneous Impedance Analysis of Non-Stationary Corrosion Process: a Case Study of Carbon Steel in 1M HCl
PublicationThe paper concerns the problem of evaluation of stationarity of carbon steel corrosion in 1M HCl. Comparison of corrosion rate with addition of corrosion inhibitor to the reference measurement is the most often used way of evaluating inhibitor efficiency. Such an approach is valid only if corrosion rate is a stationary process. Two complementary techniques were used simultaneously: volumetric analysis of evolved hydrogen and instantaneous...
-
Potentiometric Solid-Contact Multisensor System for Simultaneous Measurement of Several Ions
PublicationThe design and performance of potentiometric multisensor system made in solid-contact technology is described. Both, the measuring electrodes as well as the reference electrode are in a compact cell. The system allows for simultaneous measurement of various ions. The characteristics of the electrodes for Na+, K+ and Ca2+ ions were determined using the designed system and compared with ISEs of the same membrane composition in classical...
-
INVESTIGATION OF ACIDIC SOLUTIONS BY POTENTIOMETRIC TASTE SENSOR WITH ALL SOLID STATE ELECTRODES
PublicationPotentiometric taste sensors with electrodes containing lipophilic compound / polymer membranes were already used to distinguish commercial liquid products. In this paper a new potentiometric taste sensor consisting of six All Solid State Electrodes (ASSEs) has been presented. Each of the membrane contains a selected lipophilic compound. The set-up consists of a reference electrode and six ASSEs. The inner layer made of a conducting...
-
Li nucleation on the graphite anode under potential control in Li-ion batteries
PublicationApplication of Li-ion batteries in electric vehicles requires improved safety, increased lifetime and high charging rates. One of the most commonly used intercalation anode material for Li-ion batteries, graphite, is vulnerable to Li nucleation, a side reaction which competes with the intercalation process and leads to loss of reversible capacity of the battery, ageing and short-circuits. In this study, we deploy a combined grand...
-
Arylated carbon nanotubes for biobatteries and biofuel cells
PublicationSinglwalled carbon nanotubes (swcnts)covalently phenylated, napthylated or terphenylated were used for the construction of cathodes in a biobattery and in a biofuel cell. zn is the anode in the biobaterry and single-walled carbon nanotubes are covalently modified with glucose oxidase/catalase (swcnt-gox/cat) and the biofuel cell anode. the cell parameters were determined and the potentials of each of the electrodes under cell working...
-
Functionalization of indium-tin-oxide electrodes by laser-nanostructured gold thin films for biosensing applications
Publicationof a relatively large area formed by pulsed laser nanostructuring of thin gold films arereported and discussed. The SEM inspection of modified electrodes reveals the presence of the nearlyspherical and disc-shaped particles of dimensions in the range of 40–120 nm. The NP-array geometry canbe controlled by selection of the laser processing conditions. It is shown that particle size and packingdensity of the array are important factors...
-
A miniaturized solid-contact potentiometric multisensor platform for determination of ionic profiles in human saliva
PublicationThis paper describes a miniaturized multisensor platform (MP-ISES) consisting of electrodes: a reference one (RE) and ion-selective electrodes (ISEs) for monitoring Na+, K+, Ca2+, Mg2+, Cl−, and SCN− ions and pH in human saliva. Gold electrode surface was modified by deposition of two layers: electrosynthesized PEDOT:PSS forming an intermediate layer, and ion-selective membrane. The developed ISEs were characterized by a wide linear...
-
Processing of Ce0.8Gd0.2O2-δ barrier layers for solid oxide cells: The effect of preparation method and thickness on the interdiffusion and electrochemical performance
PublicationCe0.8Gd0.2O1.9 (CGO) barrier layers are required to mitigate the chemical reactions between Sr-containing oxygen electrode materials and Zr-based oxygen ion conductors in high-temperature solid oxide cells. Barrier layers produced by different methods were studied in this work. As a reference, a cell with no barrier layer was measured. The application of the powder-processed barrier layers, considerably increases the performance....
-
Effectiveness of a dual surface modification of metallic interconnects for application in energy conversion devices
PublicationA dual surface modification of an SOFC metallic interconnect with a Gd2O3 layer and an MnCo2O4 coating was evaluated. The tested samples were oxidized for 7000 h in air at 1073 K. Oxidation products were characterized using XRD, SEM-EDS, and confocal Raman imaging, and ASR was measured. The effect of gadolinium segregation at grain boundaries in Cr2O3 was evaluated using S/TEM-EDS. Area specific-resistance was measured and fuel...
-
The Use of Wavelet Analysis to Denoising of Electrocardiography Signal
PublicationThe electrocardiography examination, due to its accessibility and simplicity, has an important role in diagnostics of the heart ailments. It enables quick detection of various heart defects, undetectable by other kinds of diagnostic tools, so it is very popular. Nevertheless, the measured signal is exposed to a different disturbances. Among them, the electromagnetic interferences, drift of reference electrode and high frequency...
-
Novel Functionalization of Boron-Doped Diamond by Microwave Pulsed-Plasma Polymerized Allylamine Film
PublicationWe report the novel modification of a hydrogen-terminated polycrystalline boron-doped electrode with a microwave pulsed-plasma polymerized allylamine. Boron-doped diamond (BDD) was coated with a very thin layer of adherent cross-linked, pinhole- and additive-free allylamine plasma polymer (PPAAm) resistant to hydrolysis and delamination and characterized by a high density of positively charged amino groups. The pulsed microwave...
-
Three electrode configuration measurements of electrolyte-diffusion barrier-cathode interface
PublicationMeasurements of a system consisting of cathode/doped ceria diffusion barrier/doped zirconia electrolyte were made using two- and three-electrode configuration. Results obtained on a three-electrode measurement configuration were compared with and reflect the results obtained in two-electrode configuration. Three-electrode measurements allowed separating the impact of the symmetrical interface in the investigated system. They also...
-
Thin layer of ordered boron-doped TiO2 nanotubes fabricated in a novel type of electrolyte and characterized by remarkably improved photoactivity
PublicationThis paper reports a novel method of boron doped titania nanotube arrays preparation by electrochemical anodization in electrolyte containing boron precursor – boron trifluoride diethyl etherate (BF3 C4H10O), simultaneously acting as an anodizing agent. A pure, ordered TiO2 nanotubes array, as a reference sample, was also prepared in solution containing a standard etching compound: ammonium fluoride. The doped and pure titania...
-
Detection of the Plant Pathogen Pseudomonas Syringae pv. Lachrymans on Antibody-Modified Gold Electrodes by Electrochemical Impedance Spectroscopy
PublicationThe present work describes an impedimetric immunosensor for Pseudomonas syringae pv. lachrymans (Psl) detection. This pathogen infects many crop species causing considerable yield losses, thus fast and cheap detection method is in high demand. In the assay, the gold disc electrode was modified with 4-aminothiophenol (4-ATP), glutaraldehyde (GA), and anti-Psl antibodies, and free-sites were blocked with bovine serum albumin (BSA)....
-
Boron-doped diamond nanosheet volume-enriched screen-printed carbon electrodes: a platform for electroanalytical and impedimetric biosensor applications
PublicationThis paper focuses on the development of a novel electrode based on boron-doped diamond nanosheet full-volume-enriched screen-printed carbon electrodes (BDDPE) for use as an impedimetric biosensor. Impedimetric biosensors offer high sensitivity and selectivity for virus detection, but their use as point-of-care devices is limited by the complexity of nanomaterials’ architecture and the receptor immobilisation procedures. The study...
-
Enhanced susceptibility of SARS-CoV-2 spike RBD protein assay targeted by cellular receptors ACE2 and CD147: Multivariate data analysis of multisine impedimetric response
PublicationSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2) enters the cells through the binding of spike protein to the host cell surface-expressing angiotensin-converting enzyme 2 (ACE2) or by endocytosis mediated by extracellular matrix metalloproteinase inducer (CD147). We present extended statistical studies of the multisine dynamic electrochemical impedance spectroscopy (DEIS) revealing interactions between Spike RBD and...
-
Efficacious Alkaline Copper Corrosion Inhibition by a Mixed Ligand Copper(II) Complex of 2,2′-Bipyridine and Glycine: Electrochemical and Theoretical Studies
PublicationA mixed ligand copper(II) complex, namely, [Cu(BPy)(Gly)Cl]⋅2H2O (CuC) (BPy=2,2′-bipyridine and Gly=glycine), was synthesized and characterized. The synthesized CuC complex was tested as inhibitor to effectively mitigate the corrosion of copper in alkaline solutions using the linear sweep voltammetry (LSV) and linear polarization resistance (LPR) techniques. For the sake of comparison, such two D.C. electrochemical techniques were...
-
Nanocrystalline diamond microelectrode on fused silica optical fibers for electrochemical and optical sensing
PublicationFabrication process of thin boron-doped nanocrystalline diamond (B-NCD) microelectrode on fused silica single mode optical fiber has been investigated. The B-NCD films were deposited on the fibers using Microwave Plasma Assisted Chemical Vapor Deposition (MW PA CVD) at glass substrate temperature of 475 ºC. We have obtained homogenous, continuous and polycrystalline surface morphology with the mean grain size in the range of 100-250...
-
Opto-Electrochemical Sensing Device Based on Long-Period Grating Coated with Boron-Doped Diamond Thin Film
PublicationThe fabrication process of thin boron-doped nanocrystalline diamond (B-NCD) microelectrodes on fused silica single mode optical fiber cladding has been investigated. The B-NCD films were deposited on the fibers using Microwave Plasma Assisted Chemical Vapor Deposition (MW PA CVD) at glass substrate temperature of 475 ºC. We have obtained homogenous, continuous and polycrystalline surface morphology with high sp3 content in B-NCD...
-
Multi-pathway mechanism of polydopamine film formation at vertically aligned diamondised boron-doped carbon nanowalls
PublicationBoron-doped carbon nanowall (B:CNW) electrodes were used as a platform for studying the electropolymerisation of dopamine. Due to the unique properties of B:CNW, including the fast charge-transfer kinetics and high surface conductivity, a high degree of reversibility of redox reactions was achieved. Three separated redox peaks were observed on voltammograms and attributed to three fundamental reactions in the dopamine polymerisation...
-
Estimation of electrode contact in capacitive ECG measurement
PublicationIn the paper a method of electrode’s contact estimation in capacitive electrocardiogram (CECG) is presented. Proposed solution allows estimation of contact quality for each individual electrode. This enables construction of multi-electrode CECG systems, where electrode pairs can be selected on the basis of the individual electrode contact quality.
-
Influence of electrode geometric arrangement on the operation of narrow circular electrostatic precipitator
PublicationIn this work the influence of electrode geometric arrangement on the operation of a circular electrostatic precipitator (ESP) was investigated using Particle Image Velocimetry (PIV) method. The ESP was a glass circular cylinder (29 mm in diameter, 300 mm long) equipped with a wire discharge electrode and circular-cylinder collecting electrode. The stainless-steel discharge wire electrode (0.23 mm in diameter, 100 mm long) was mounted...
-
Hybrid biobateryy based on arylated carbon nanotubes and laccase
PublicationSingle-walled carbon nanotubes (SWCNT) were covalently modified with antracene and antraquinone and used for the construction of cathodes for biocatalytic reduction od dioxygen. The nanotubes with aromatic groups casted onto the electrode increased the working surface of the electrode and enabled efficient direct electron tarnsfer (DET) between the enzyme and the electrode. the aryl groups enter the hydrophobic pocket of the T1...
-
Poly(hydroxybutyrate-co-hydroxyvalerate) as a biodegradable binder in a negative electrode material for lithium-ion batteries
PublicationIn this work, graphite-based negative electrode for lithium-ion battery consisting a novel and biodegradable binder poly(hydroxybutyrate-co-hydroxyvalerate) (PHBV) is compared with standard graphite electrode with polyvinylidene fluoride (PVDF) as a binder. The rate and cycling performance of lithium ion insertion/extraction of electrodes with PHBV in a half-cell configuration are evaluated. Moreover, on the basis of the electrochemical...
-
Comparison of the paracetamol electrochemical determination using boron-doped diamond electrode and boron-doped carbon nanowalls
PublicationTwo different type of electrodes, boron-doped diamond electrode (BDD) and boron-doped carbon nanowalls (B:CNW) electrode, were used for the electrochemical determination of paracetamol using the cyclic voltammetry and the differential pulse voltammetry in phosphate buffered saline, pH = 7.0. The main advantage of these electrodes is their utilization without any additional modification of the electrode surface. The peak current...
-
Study of Metrological Properties of Voltammetric Electrodes in the Time Domain
PublicationMetrological properties of voltammetric electrodes, in the situation where on their surface an electrochemical reaction of oxidizing/reduction takes place, were analyzed in this chapter. The properties of electrodes on which a reaction controlled by ion transport process takes place were taken into consideration. Also, it was analyzed how the electrode’s shape and the voltage polarizing the electrode influence this electrode’s...
-
Exploring multi-step glucose oxidation kinetics at GOx-functionalized nanotextured gold surfaces with differential impedimetric technique
PublicationFor a few past years, we can observe the enormous growth of investigations related to ultrasensitive electrochemical sensors capable of reliable determination of important body parameters and analytes. Utilized procedures rely on standard electrochemical methods, demanding electrode polarization, and information about the initial characteristics of the working electrode. More and more complex electrode materials are characterized...
-
The phenomenon of increasing capacitance induced by 1T/2H-MoS2 surface modification with Pt particles – Influence on composition and energy storage mechanism
PublicationIn this paper, several approaches to the synthesis of molybdenum-based electrode materials for supercapacitors are presented, including anodization, hydrothermal process and annealing. For the material prepared via anodization of a molybdenum plate, followed by a hydrothermal process in thiourea aqueous solution, a thorough study of the Pt-surface modification through repetitive cycling in 1 M sulfuric acid with Pt acting as a...
-
Electrohydrodynamic Flow Patterns in a Narrow Electrostatic Precipitator with Longitudinal Wire Electrode for Various Electrode Geometries
PublicationRecently narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application in diesel engines. In this paper results of 2-dimensional (2D) Particle Image Velocimetry (PIV) measurements of the flow patterns in a narrow ESP for a various electrode geometries are presented. The PIV measurements were carried out in the observation plane that is perpendicular to the ESP duct. The ESP was...
-
Sinusoidal Alternating-Current Voltammetry and Metrological Properties of a Flat Voltammetric Electrode in the Time Domain
PublicationIn this paper there were analyzed metrological properties of a flat electrode used to mark ions with the method of sinusoidal alternating-current voltammetry in the situation where on its surface an electrochemical reversible reaction of oxidizing / reduction takes place. The result of the analysis conducted is that such a voltammetric electrode functions like a converter type I. Metrological properties of such an electrode in...
-
Flexible dye-sensitized solar cells based on Ti/TiO2 nanotubes photoanode and Pt-free and TCO-free counter electrode system
PublicationFlexible dye-sensitized solar cells (DSSCs) are getting more attention compared to standard glass covered DSSCs due to their unique commercial applications (e.g. tents or sail surfaces) and the possibility of rolling up into a small, portable device. In this work, titania nanotubes (TiO2 NT) modified with titania nanoparticles (TiO2 NP) were photoelectrochemically characterized as an anode for flexible dye-sensitized solar cells....