Filters
total: 3237
-
Catalog
displaying 1000 best results Help
Search results for: Coal power plants
-
Small power laboratory model and high power prototype of the four-level VSI
Publication -
Analysis of the instantaneous power signal for bearing diagnostics -bearing damaged
Open Research DataThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of a damaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Analysis of the instantaneous power signal for bearing diagnostics - bearing undamaged
Open Research DataThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of an undamaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Optimal Rotating Receiver Angles Estimation for Multicoil Dynamic Wireless Power Transfer
PublicationThis study proposed an approach to dynamic wireless charging that uses a rotating receiver coil. Our simulation study focused on the verification of a novel way of increasing the coupling coefficient and power transfer stability by following the flux of the transmitting coils. To obtain the highest possible coupling by means of the FEM analysis, we studied the optimization of the trajectory of the angular velocity of the rotating...
-
The Balance of Outlays and Effects of Restructuring Hard Coal Mining Companies in Terms of Energy Policy of Poland PEP 2040
Publication -
Operation of the 900 MW power plant with the ORC supplied from three heat sources
PublicationThe chapter is aimed at utilisation of waste heat in the reference supercritical power plant in the manner to produce electricity in ORC installation. The waste heat is available in the form of a stream of hot water at 90°C, recovered from the exhaust gases in the amount of 200MW. Such low enthalpy heat source is rather insufficient to produce a good quality vapour to feed the ORC turbine. Therefore an original approach to increase...
-
Numbers, Please: Power- and Voltage-Related Indices in Control of a Turbine-Generator Set
PublicationThis paper discusses the proper selection and interpretation of aggregated control performance indices values mirroring the quality of electrical energy generation by a turbine-generator set cooperating with a power system. Typically, a set of basic/classical and individual indices is used in energy engineering to ensure the mirroring feature and is related to voltage, frequency and active or reactive power deviations from their...
-
Innovative Bidirectional Isolated High-Power Density On-Board Charge for Vehicle-to-Grid
PublicationThis paper deals with developing and implementing a bidirectional galvanically isolated on-board charger of a high-power density. The power density of the new charger was 4 kW/kg and 2.46 kW/dm3, and the maximum efficiency was 96.4% at 3.4 kW. Due to the requirement to achieve a high-power density, a single-stage inverter topology was used. Regarding switching losses, due to the topology of the circuit with so-called hard switching,...
-
Ryszard Strzelecki prof. dr hab. inż.
People -
Analog CMOS processor for early vision processing with highly reduced power consumption
PublicationA new approach to an analog ultra-low power visionchip design is presented. The prototype chip performs low-levelconvolutional image processing algorithms in real time. Thecircuit is implemented in 0.35 μm CMOS technology, contains64 x 64 SIMD matrix with embedded analogue processors APE(Analogue Processing Element). The photo-sensitive-matrix is of2.2 μm x 2.2 μm size, giving the density of 877 processors permm2. The matrix dissipates...
-
Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublicationOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...
-
Możliwości sterowania mocą bierną elektrowni wiatrowej : Reactive power control methods in wind parks
PublicationReferat poświęcony jest zagadnieniu sterowania mocą bierną w elektrowniach wiatrowych. W pierwszej części referatu opisano tło problemu sterowania mocą bierną w parkach wiatrowych, podano powody, dla których moc bierna powinna podlegać regulacji oraz zarysowano metody, które mogą być do niej użyte. W celu sprawdzenia proponowanych metod kompensacji, zbudowano model matematyczny elektrowni wiatrowej, którego poszczególne elementy...
-
Magnetic and capacitive couplings influence on power losses in double circuit high voltage overhead transmission line
PublicationPurpose – The paper aims to discuss problems of power and energy losses in a double-circuit overhead transmission line. It was observed from energymeters’ readings, that in such a line, active power losses can be measured as “negative”. The “negative” active power losses appear when the active power injected to the circuit is lower than the active power received at the circuit end. The purpose of this paper is to explain this phenomenon. Theoretical...
-
COMPARATIVE EVALUATION OF FERRITE SHIELDING DESIGNS IN INDUCTIVE POWER TRANSFER SYSTEMS
PublicationWireless power transfer technology is becoming widespread in last few years. In comparison to conventional solutions this technology can significantly increase maintainability and safety of charging systems. From the other side there are list of factors that limit efficiency of wireless systems. One of them is low coupling between coils caused by comparably high leakage inductance in comparison to regular transformer.
-
Impact of thermal backfill parameters on current-carrying capacity of power cables installed in the ground
PublicationProper design of power installations with the participation of power cables buried in homogeneous and thermally well-conductive ground does not constitute a major problem. The situation changes when the ground is non-homogeneous and thermally low-conductive. In such a situation, a thermal backfill near the cables is commonly used. The optimization of thermal backfill parameters to achieve the highest possible current-carrying capacity...
-
5G Millimeter Wave Network Optimization: Dual Connectivity and Power Allocation Strategy
PublicationThe fifth generation (5G) of mobile networks utilizing millimeter Wave (mmWave) bands can be considered the leading player in meeting the continuously increasing hunger of the end user demands in the near future. However, 5G networks are characterized by high power consumption, which poses a significant challenge to the efficient management of base stations (BSs) and user association. Implementing new power consumption and user...
-
The Influence of Cooperation on the Operation of an MPC Controller Pair in a Nuclear Power Plant Turbine Generator Set
PublicationThe paper discusses the problem of cooperation between multiple model predictive control (MPC) systems. This approach aims at improving the control quality in electrical energy generation and forms the next step in a series of publications by the authors focusing on the optimization and control of electric power systems. Cooperation and cooperative object concepts in relation to a multi MPC system are defined and a cooperative control...
-
Energy consumption estimation of low-power devices using an integrating coulombmeter
PublicationThe main problem in designing devices powered with Energy Harvesting is an estimation of energy demand of low-power devices as well as quantity of energy provided by the selected energy transducer in the assumed work conditions. Due to the work characteristic of each block of the device and properties of the measured signal, measurement is not trivial. The paper presents the proposal of the micro-charge measurement device based...
-
Determination of Mechanical Energy Loss in Steady Flow by Means of Dissipation Power
PublicationWhen systems of simple geometry like pipes or regular channels are considered, the mechan- ical energy loss of the fluid flow can be expressed by local and longitudinal empirical energy loss coefficients. However, in the case of large spatially distributed objects, there are no simple approaches to this task. In practice, general recommendations addressing different types of objects are used, but they usually provide very coarse...
-
How to eliminate the formation of chlorogenic acids artefacts during plants analysis? Sea sand disruption method (SSDM) in the HPLC analysis of chlorogenic acids and their native derivatives in plants
Publication -
An Intelligent Approach to Short-Term Wind Power Prediction Using Deep Neural Networks
PublicationIn this paper, an intelligent approach to the Short-Term Wind Power Prediction (STWPP) problem is considered, with the use of various types of Deep Neural Networks (DNNs). The impact of the prediction time horizon length on accuracy, and the influence of temperature on prediction effectiveness have been analyzed. Three types of DNNs have been implemented and tested, including: CNN (Convolutional Neural Networks), GRU (Gated Recurrent...
-
Empirical verification in industrial conditions of fracture mechanics models of cutting power prediction
PublicationA comparison of experimental results obtained in the industrial conditions at a sawmill located in the Baltic Natural Forest Region (PL) and theoretical cutting power consumption forecasted with the models which include work of separation (fracture toughness) in addition to plasticity and friction has been described. In computations of cutting power consumption during rip sawing of Scots pine wood (Pinus sylvestris L.) values of...
-
Performance and Energy Aware Training of a Deep Neural Network in a Multi-GPU Environment with Power Capping
PublicationIn this paper we demonstrate that it is possible to obtain considerable improvement of performance and energy aware metrics for training of deep neural networks using a modern parallel multi-GPU system, by enforcing selected, non-default power caps on the GPUs. We measure the power and energy consumption of the whole node using a professional, certified hardware power meter. For a high performance workstation with 8 GPUs, we were...
-
Comparative study of a combined heat and power plant retrofitted by CO2 capture during the combustion of syngas from sewage sludge gasification versus zero-emission combustion of hydrogen produced using renewables
PublicationWith ecological requirements aimed at limiting the production of CO2, it is necessary to produce all, or most of the energy from RES. During the transformation process, ecological and highly efficient combustion power plants will be needed. The classic cycle of combined heat and power (CCGT) with green improvements will continue to be one of the most suitable technologies for this task. This article presents the modernization of...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublicationThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Ocena możliwości wykorzystania technologii Power over Ethernet w sieciach przemysłowych
PublicationW pracy opisano standard zasilania przez Ethernet IEEE 802.3af. Przedstawiono podstawowe zalety i wady tego rozwiązania. Oceniono możliwość bezpośredniego wykorzystania technologii Power over Ethernet w sieciach przemysłowych.
-
Fast geometry scaling of miniaturized microwave couplers with power split correction
PublicationRedesigning a microwave circuit for various operating conditions is a practically important yet challenging problem. The purpose of this article is development and presentation of a technique for fast geometry scaling of miniaturized microwave couplers with respect to operating frequency. Our approach exploits an inverse surrogate model constructed using several reference designs that are optimized for a set of operating frequencies...
-
Sustainable Use of the Catenary by Trolleybuses with Auxiliary Power Sources on the Example of Gdynia
PublicationThe current developments in onboard power source technology, in particular, traction batteries, open up new potential in trolleybus transport and also make it possible to introduce electric buses. Thus far, trolleybus transport has required the presence of overhead lines (OHL). Introducing trolleybuses with onboard batteries makes it possible to grow the zero-emissions transport network in places with limited power supply capabilities...
-
Experiment-Based Study of Heat Dissipation from the Power Cable in a Casing Pipe
PublicationThe paper deals with the important challenges in terms of electricity transmission by means of underground cable lines. The power cable’s performance is characterized by an ampacity that represents its maximum electric current-carrying capacity. The ampacity of power cables depends on their ability to diffuse the heat generated by the current flow into the environment. In the performed research, the analysis of the efficiency of...
-
Effect of pine impregnation and feed speed on sound level and cutting power in wood sawing
PublicationThe sound levels along with the cutting power registered during the sawing process of the impregnated and non-impregnated pine wood at two feed speeds are shown and compared in this paper. Statistically significant differences in the acoustic signals occurred at the lower feed rate. The differences became smaller with an increase in the feed speed. In contrast to the sound signal, the differences...
-
Overheating of underground power cable line due to its partial exposition to solar radiation
PublicationCurrent-carrying capacity of underground power cable lines depends, among others, on thermal resistivity of the soil and cables layout: trefoil formation, flat formation with or without spacing. If conditions for heat transfer in the ground are favorable, the current-carrying capacity is relatively high. Therefore, it generates risk of the power cables overheating, if part of the cable line is located vertically in the air, to...
-
Critical approach to PLE technique application in the analysis of secondary metabolites in plants
Publication -
The Impact of Technological Processes on Odorant Emissions at Municipal Waste Biogas Plants
Publication -
Application of Sea Sand Disruption Method for HPLC Determination of Quercetin in Plants
Publication -
Completing Autophagy: Formation and Degradation of the Autophagic Body and Metabolite Salvage in Plants
Publication -
FT-Raman spectroscopy as a tool in evaluation the response of plants to drought stress
Publication -
Energy conversion in small water plants with variable speed PM generator
Publication -
Light emitting diodes optimisation for secondary metabolites production by Droseraceae plants
Publication -
Contribution of PsbS Function and Stomatal Conductance to Foliar Temperature in Higher Plants
Publication -
Ficus plants: State of the art from a phytochemical, pharmacological, and toxicological perspective
Publication -
Safety Integrity Verification Issues of the Control Systems for Industrial Process Plants
PublicationThe aim of this article is to identify and discuss some issues that can be encountered in designing the industrial automation and control systems (IACS) for implementing safety functions. In a functional safety standard IEC 61511 for the process industry such systems are named the basic process control systems (BPCS) and the safety instrumented systems (SIS). In a generic functional safety standard IEC 61508 they are depicted as...
-
Robust design in delta domain for SISO plants: PI and PID controllers
PublicationW pracy przedstawiono zunifikowaną metodę numerycznie odpornej syntezy sterowników (regulatorów) działających w dyskretnym czasie w układach sterowania skalarnymi obiektami czasu ciągłego. Wykorzystano dyskretnoczasowe modele takich obiektów, oparte na tak zwanym operatorze delta, charakteryzującym się korzystnymi odpornościowymi cechami w przypadku stosowania dostatecznie małych wartości okresu próbkowania przetwarzanych sygnałów....
-
Effect of hybrid contactless short-cicruit limiters on power quality
PublicationPrzedstawiono działanie bezstykowego ogranicznika prądów zwarciowych w oparciu o symulację komputerową. Szczególną uwagę zwrócono na problem jakości dostarczanej energii elektrycznej poprzez ograniczanie zapadów napięcia za pomocą bezstykowego ogranicznika prądów zwarciowych. W modelowaniu elementów systemu elektroenergetycznego i zapadów napięcia, będących skutkiem zwarć wykorzystano program MATLAB z biblioteką Power System Blockset....
-
Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter
PublicationThe paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...
-
Power Surge Compensator based on a Four Level Diode Clamped Inverter for ship application. Average model
PublicationPaper presents continuous average value model of Power Surge Compensator based on a Four Level Diode Clamped Inverter with super capacitor as a energy storage device. This conditioner is design for power surge or fluctuation elimination, by compensating it with energy stored in ESD. Continuous average value model of multilevel S-PWM has been presented also. Summary of raised problem is a simulation model made in PowerSim Psim 8...
-
Multi-nodal PWR reactor model — Methodology proposition for power distribution coefficients calculation
PublicationIn the paper the multi-nodal Pressurized Water Reactor (PWR) model called Mann’s model is presented. This models is used for modelling purposes of the heat transfer from fuel to coolant in reactor core. The authors expand widely used in literature approach by defining additional coefficients for the heat transfer model. These parameters approximate the power generation distribution in the PWR reactor core according to the to the...
-
A new method of wind farm active power curve estimation based on statistical approach
PublicationThe purpose of this paper is to solve the wind farm active power estimation problem, introducing the method which is based on a statistical approach and robust fitting. The proposed algorithm uses a statistical approach and compared to existing ones- includes a wind direction as well as the influence of turbine start-up procedure on the estimation. The results show that additional estimation inputs i.e. the wind direction and the...
-
Technical and Economic Analysis of an Intermediate Size Photovoltaic Power Plant. Case Study
PublicationThe article presents an analysis of the construction of a photovoltaic power plant with an installed capacity of about 30 kW. The principles of selecting the basic elements of the plant are shown. The impact of a high constant price on the profitability of the project is highlighted. The article also describes the existing mechanisms for subsidizing the investment.
-
Comprehensive compensation of grid current distortion by shunt active power filters
PublicationThe paper presents a comprehensive approach to the compensation of grid current distortion in shunt active power filter systems. Four sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the evaluation of grid voltages and computation of compensating currents, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Induction Generator with Direct Control and a Limited Number of Measurements on the Side of the Converter Connected to the Power Grid
PublicationThe article presents an induction generator connected to the power grid using the AC/DC/AC converter and LCL coupling filter. Three-level inverters were used in the converter, both from the generator side and the power grid side. The algorithm realizing Pulse Width Modulation (PWM) in inverters has been simplified to the maximum. Control of the induction generator was based on the Direct Field-Oriented Control (DFOC) method. At...