Search results for: air protection
-
Landscape as a Potential Key Concept in Urban Environmental Planning: The Case of Poland
PublicationRapid urban development increases the consumption of materials, energy, and water, resulting in an overproduction of waste and emissions. These cause many environmental threats, such as ozone layer depletion and rain acidification, leading to climate change. Therefore, the question arises on how to improve the effectiveness of tools that strengthen environmental protection. This discursive article presents an approach stressing...
-
The protection and monitoring of a distribution piping network for potable water supply
PublicationPurpose – The purpose of this paper is to implement the corrosion protection method for steel pipes used in a municipal water-pipe network. Results of an inhibitor protection system installed on the system are presented. Inhibitor protection was required due to the high corrosivity of the water collected by a surface intake, which had resulted in a large number of failures and low water quality, due to the presence of corrosion...
-
Residual Current Devices: Selection, Operation, and Testing
PublicationIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...
-
Protection of bridges against stray current corrosion
PublicationA case study of Siennicki Bridge stray current corrosion hazard is presented. A corrosion risk was caused by incorrectly designed tram line traction which goes over the bridge. No dielectric insulation between running rails and bridge steel construction was used. A variety of protection methods against stray currents are described. Characteristics of the endangered bridge were described. Impressed current cathodic protection system...
-
Antioxidant properties of ferrous flavanol mixtures
PublicationInteraction of metal, especially iron ions with flavanols is considered as an important feature of these compounds and is believed to contribute to their both antioxidant and prooxidant properties. The aim of this study was to examine how Fe2+ binding to form a 4:1 (flavanol:Fe2+) mixtures affects the antioxidant properties of flavanols. ABTS∗ scavenging, protection against fluorescence bleaching induced by AAPH and hypochlorite,...
-
Structure of the register of immovable monuments by date of individual objects – comparison of 2017 and 2024
Open Research DataThe register of monuments is the primary form of monument protection. The register for monuments in the voivodeship is kept by the voivodeship conservator of monuments in the form of separate books for immovable (book A), movable (book B), and archaeological (book C) monuments. Entries in the register of monuments are made upon application by the owner...
-
Application of RCD and AFDD in low-voltage electrical installations for protection against fire
PublicationThe paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.
-
Evaluation of organic coating systems for corrosion protection of industrial equipment using impedance spectroscopy
PublicationThe high economic impact of corrosion can be reduced by enhanced corrosion management and prevention based on appropriate means. This applies in particular to the protection of structures with organic protective coatings. Steel is subject to corrosion that reduces its service life and leads to destruction in most severe cases. The application of paints to metallic objects for corrosion control has been known for a long time and...
-
BODYGUARD PROFESSION A GUIDE TO THE ART OF PERSONAL PROTECTION
PublicationThe book "Bodyguard Profession: A Guide to the Art of Personal Protection" is a comprehensive guide that introduces readers to the intricacies of professional personal protection. The author thoroughly discusses both the physical and psychological aspects of a bodyguard's work, covering elements such as stress management, self-defense techniques, and the use of modern technology in VIP protection. The guide presents...
-
Thermal and Electrodynamic Risk of Residual Current Devices in the Case of Back-Up Protection by Overcurrent Circuit Breakers
PublicationResidual current operated circuit breakers without integral overcurrent protection should be back-up protected. As back-up protection devices, overcurrent circuit breakers are used. The maximum let-through energy and let-through current of the overcurrent devices were evaluated under laboratory conditions. The thermal and electrodynamic risk of residual current devices was analyzed.
-
Main Outlines of Lightning Research Development in Poland
PublicationThe paper deals with the historical development of lightning protection research, lightning protection ideas and investigations in Poland. The main achievements of lightning research performed at the technical universities in Gdansk, Warsaw and Rzeszow have been characterized. Exemplary main achievements related to natural lightning observations and measurements as well to those performed in laboratory scale tests have been shortly...
-
Problems of Selecting Protection for Shunt Reactors Working in Extra-High Voltage Grids
PublicationThis paper presents difficulties encountered when designing protection devices for shunt reactors connected directly to extra-high voltage grids. Using the example of the 400 kV Ełk Bis substation, it has been demonstrated that protection of a shunt reactor based on equipment using measurements of electrical signals from voltage and current transformers has its limitations and, in some cases, may be insufficient.
-
Electrolytic corrosion of water pipeline system in the remote distance from stray currents– case study
PublicationCase study of corrosion failure of urban water supply system caused by the harmful effects of stray currents was presented. The failure occurred at a site distant from the sources of these currents namely the tramway and railway traction systems. Diagnosis revealed the stray currents flow to pipeline over a remote distance of 800 ÷ 1,000 meters from the point of failure. At the point of failure stray currents flowed from the pipeline...
-
Integrated safety and security analysis of hazardous plants and systems of critical infrastructure
PublicationThis article addresses an integrated safety and security analysis approach of hazardous industrial plants and systems of critical infrastructure. Nowadays due to new hazards that emerge there are opinions among experts that these issues require an integrated approach in life cycle, from the design concept, through the design and operation of the plant, to its decommissioning. It is proposed to start from an interesting methodology...
-
Behavior of residual current devices at frequencies up to 50 kHz
PublicationThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
Komentarz do art. 87 ustawy o ochronie konkurencji i konsumentów
PublicationCommentary to the provision of the Act on Protection of Competition and Consumers concerning the refusal to institute an antitrust proceeding
-
APPLICATION OF ULTRAFAST GAS CHROMATOGRAPHY TO RECOGNIZE ODOR NUISANCE
PublicationPotentialities of ultrafast gas chromatography applied to periodical monitoring of odor nuisance originating from a municipal landfill have been examined. The results of investigation on classification of the atmospheric air samples collected in a vicinity of the landfill during winter and summer season have been presented. The investigation was performed using ultrafast gas chromatography of Fast/Flash GC type HERACLES II by Alpha...
-
Impulse Impedance Measurements of Lightning Protection Earthings
PublicationLightning protection earthing systems should be tested at currents with time parameters similar to those of lightnings. A method and definition of a measured value of impulse impedance are introduced. The impulse impedance was determined by a quotient of voltage drop on the tested earthing to a value of current in measure circuit. The usefulness of the impulse method for lightning protection evaluation is tested on radio base stations...
-
METHODS OF TEACHING NOISE PROTECTION AT ENVIRONMENTAL ENGINEERING
PublicationNoise strongly influences both our health and behavior in everyday life and as employees or employers. The lost of hearing and other effects of noise on humans result not only in a significant decrease in the quality of life or work efficiency but have also have economic consequences. As noise can be preventable in part by the Environmental Engineers, but it is necessary to introduce them noise issues during their education process....
-
Cost assessment of computer security activities
PublicationComprehensive cost-benefit analysis plays a crucial role in the decision-making process when it comes to investments in information security solutions. The cost of breaches needs to be analysed in the context of spending on protection measures. However, no methods exist that facilitate the quick and rough prediction of true expenditures on security protection systems. Rafal Leszczyna of Gdansk University of Technology presents...
-
Time evolution of Electrochemical Impedance spectra of cathodically protected steel in artificial seawater
PublicationUsability of Electrochemical Impedance Spectroscopy data for better cathodic protection control was investigated. Carbon steel – S235JR2 grade specimen were exposed in artificial seawater environment. Samples were polarized and their potentials corresponded to four different cathodic protection degrees. Time evolution of Electrochemical Impedance spectra was investigated. Goodness of fit function (X2) was analysed in terms of proper...
-
Komentarz do art. 105 i ustawy o ochronie konkurencji i konsumentów
PublicationCommentary to the article of the Act of Protection of Competition and Consumers on the inspection led by the Polish Competition Authority for the European Commission
-
Flood Modelling and Risk Analysis of Cinan Feizuo Flood Protection Area, Huaihe River Basin
PublicationThis study evaluated multiple aspects of flood risks and effects on the Cinan Feizuo flood protection area in the Huaihe River basin. Flooding remains a leading problem for infrastructure, especially in urban, residential areas of the region. Effective flood modeling for urbanized floodplains is challenging, but MIKE (ID-2D) is paramount for analyzing and quantifying the risk in the vulnerable region. The Saint-Venant equation...
-
Method of sacrificial anode transistor-driving in cathodic protection system
PublicationA magnesium anode driving system has been proposed. A PNP driving transistor has been used. Electrochemical testing in 3%NaCl, results and comparison of the driving system and classic direct anode to cathode connection are presented. The driving system reduced the protection current and stabilized the working conditions of the anode. Higher anode efficiency was achieved. Overprotection and hydrogen embrittlement threats were prevented...
-
Multisensor System for the Protection of Critical Infrastructure of Seaport
PublicationThere are many separated infrastructural objects within a harbor area that may be considered “critical”, such as gas and oil terminals or anchored naval vessels. Those objects require special protection, including security systems capable of monitoring both surface and underwater areas, because an intrusion into the protected area may be attempted using small surface vehicles (boats, kayaks, rafts, floating devices with weapons...
-
Protection and renovation of public areas in a modernist city: the case of three streets in the historic City Centre of Gdynia
PublicationThis article concerns issues related to the preservation and restoration of public space in Gdynia’s city centre, which was designed and built mainly in the 1920s and 1930s. In 2007, a major part of the city centre was entered into the register of monuments asa historic complex of urban architecture. Moreover, in 2015, the area was declared a Monument of History. Protection of a complex of urban architecture covers not only the...
-
The Conservation and Preservation of Gdynia`s Modernist Architecture
PublicationThe paper presents the introducing of legal protection in Gdynia City Center and conservation of modern monuments built before WWII in this town
-
Gdynia City Centre as a Historical Monument
PublicationThe articel presents the experience connected with the legal protection and conservation of modern monuments built before WWII in Gdynia City Center
-
Failures and a concept of corrosion protection system for spiral classifiers at KGHM Polska Miedź S.A. Ore Concentration Plant
PublicationThe Ore Concentration Plant, where the process of flotation is carried out as well as the final production of copper concentrate, plays a key role in the entire production line of KGHM Polska Miedź S.A. Majority of operations related to the run-of-mine preparation to copper flotation enrichment are carried out in a water environment. The maintaining of production process continuity requires to pursue minimisation of many production...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Multisource model of ship electric field
PublicationA steel-hulled ship in sea water produces an electric field around itself. The source of this field are electrochemical processes and ship's cathodic protection. The analysis of the electric field around the ship is important by the reason of the ship's identification and counter-mine protection. The paper presents a simplified model of the ship's multisource electric field, which allows to calculate the electric field distribution...
-
Underwater Electrochemical Offshore Tests of a Paint Coating Applied in Water on the Legs of an Oil Production Platform
PublicationThis paper presents the methodology developed for underwater measurements using electrochemical impedance spectroscopy (EIS) technique, aimed at determining the resistance of an epoxy coating applied in seawater to the legs of an oil production platform. Performing such underwater tests in an offshore environment was technically challenging. The results of measurements obtained on the platform were confronted with comparative results...
-
Performance analysis of power swing blocking feature in ABB 670 series impedance relays
PublicationThis paper presents test results of a distance protection’s PSD power swing detection feature in ABB 670 series relays. A RED670 relay was tested, which is part of the hydroelectric set protection in Żarnowiec Pumped Storage Plant. The power swing blocking feature’s performance was analysed on the basis of the results of object tests made with an Omicron digital tester. Also presented are simulation results that illustrate the...
-
Resonance problems in UHV transmission lines
PublicationThe paper presents resonance phenomena observed in 400 kV transmission lines in the Polish power system. Two events are analysed, when shunt reactors used for reactive power compensation, caused overvoltages and overcurrent protection tripping as a result of resonance. An oscillographic fault recordings from protection devices are compared to time domain simulation results. The obtained simulation results match fault recordings,...
-
Expert opinion on the effectiveness of protection against electric shock in case of fault in an installation for electric vehicles charging
PublicationThe opinion concerns the use of residual current devices for protection against electric shock by automatic disconnection of supply in a Norwegian installation intended for charging of electric vehicles.
-
Sanctions and their role in preventing the appropriation of the creditor’s property rights in bankruptcy proceedings–the case of Poland
PublicationThe aim of this paper is to fill the cognitive gap regarding the role of sanc-tions in the protection of a creditor’s property rights in the event of an entrepreneur insolvency. The impact of sanctions on transaction costs, including their identifica-tion and types, as well as the impact on the protection of creditor rights, has been poorly recognized in the subject literature to date. This article investigates...
-
Functional safety and reliability analysis methodoloogy for hazardous industrial plants
PublicationThis monograph is devoted to current problems and methods of the functional safety and reliability analyses of the programmable control and protection systems for industrial hazardous plants. The results of these analyses are useful in the process of safety management in life cycle, for effective reducing relevant risks at the design stage, and then controlling these risks during the operation of given installation. The methodology...
-
Adhesion of organic coatings to hot-dip galvanized steel
PublicationDuplex systems provide long-time corrosion protection, much longer than the sum of the lifetimes of zinc and paint used individually. However loss of adhesion between coating and zinc substrate is often found in practice. Different methods of zinc surface preparations are used in the fi eld. The aim of this study was to examine and compare coating protection when the old zinc surface, stored during long-time period (15 years) in...
-
Integrated functional safety and cyber security analysis
PublicationThe chapter is devoted some important issues of the functional safety analysis, in particular the safety integrity level (SIL) verification of safety functions to be implemented within the distributed control and protection systems with regard to security aspects. A method based on quantitative and qualitative information is proposed for the SIL (IEC 61508, 61511) verification with regard of the evaluation assurance levels (EAL)...
-
Reforms of Polish Antitrust Law: Closer to, or Further From, the European Model? Journal of European Competition Law and Practice
PublicationThe Polish Act on the Protection of Competition and Consumers has been recently amended. Changes include the introduction of a two-phase based merger control, a more efficient leniency program, and the administrative liability of individuals involved in antitrust agreements.
-
Valuation of architectural heritage by multicultural student groups
PublicationIn this article, the author addresses the education of architecture students in the field of architectural history and the determination of the value of architectural objects. Important changes at present are underway concerning this. Both the role of architectural history in architectural education and content in architectural history curricula is changing. The need for re-evaluation...
-
Determining and verifying the safety integrity level with security aspects
PublicationSafety and security aspects consist of two different group of functional requirements for the control and protection systems. It is the reason why the analyses of safety and security shouldnt be integrated directly. The paper proposes extension of the currently used methods of functional safety analyses. It can be done with inclusion of the level of information security assigned to the technical system. The article addresses some...
-
The Modernist Centre of Gdynia. Management Plan for the Nominated Property for the Years 2022-2027. Attachment to: Nomination Dossier on the inscription on the UNESCO World Heritage List of a part of Gdynia City Centre, Poland
PublicationThe Management Plan is a document that helps in managing the Nominated Property and follows the Operational Guidelines for the Implementation of the Convention. The Plan is intended as a management tool to ensure the protection and maintenance of the Outstanding Universal Value (OUV) and the features that determine the integrity and authenticity of the place.
-
Zabezpieczenia antykorozyjne stalowych barierek ochronnych na obiektach mostowych w ujęciu kosztów cyklu ich życia
PublicationThe article presents the Life Cycle Costs analysis of steel safety barriers operated in road lane conditions, located on a selected bridge structure. Three corrosion protection systems were proposed, analyzing them in terms of the cost of initial and planned outlays related to maintenance. Based on the LCC analysis for three options, taking into account the 25-year lifetime of the barriers, the optimal solutionwas indicated, i.e....
-
Ranking ecosystem services delivered by trees in urban and rural areas
PublicationPolicies and strategies for tree management and protection on a national, regional, and local level have not sufficiently considered differences between rural and urban areas. We used expert knowledge to compare rural and urban areas in a case study evaluating the relative importance of ecosystem services (ES) in policy development. The Analytic Hierarchy Process (AHP) and focus group discussions were used to rank 17 ES, representing...
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublicationA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
THE METHOD OF ENERGY-EFFICIENCY INVESTIGATIONS OF THE NEWLY PRODUCED MARINE FUELS THROUGH AN APPLICATION OF THE LABORATORY DIESEL ENGINE
PublicationThe article deals with one of the scientific issue solved within frames of the research project financed by Voivodeship Fund for Environmental Protection and Water Management in Gdansk, namely, in particular, the method of energy investigations of the self-ignition engine in conditions of its supply with a non-standard (modified) marine fuel. The representative results of engine tests worked out on the especially built laboratory...
-
Performance of zinc-rich coatings evaluated using AFM-based electrical properties imaging
PublicationThe paper presents the results of investigation of polyvinyl zinc-rich coating exposed to 97% relativehumidity atmosphere for 40 days. Condition of the coating and evolution of its protective properties weredetermined with the novel AFM-based approach capable of providing surface profiles, local dc currentmaps as well as local impedance spectra. The proposed technique allowed insight into the local changesof coating topography...
-
Fortifications of Hel Peninsula in Poland – history, preservation and contemporary adaptation.
PublicationThe Hel Peninsula fortifications are one of the largest and most interesting historic coastal fortification complexes in Poland. Built from the 1930s until demilitarisation at the end of the Cold War, they are now one of the biggest tourist attractions of the region. The article attempts to describe the history of their development, current state and selected problems related to their protection and adaptation for touristic purposes....
-
Remarks on the Subject of Back-Up Protection of Residual Current Devices
PublicationResidual current devices without integral overcurrent protection (RCCBs) are back-up protected by fuses or miniature circuit-breakers (MCBs). If the latter are used, special attention must be given to the coordination between an RCCB and an MCB. This paper indicates probable cases of the aforementioned devices coordination, in which back-up protection of the RCCB is not adequate. A laboratory test has shown that depending on the...