Search results for: frequency measurement
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 3
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name EPCS1) sample 3. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Channel Impulse Response Measurements at mmWave Band in Office and Conference Rooms
PublicationIn this paper, the measurements of the channel impulse response at mmWave band in office and conference rooms are described. The central frequency is 27 GHz with a bandwidth of 400 MHz. The description of the used measurement stand and considered environments are presented. The initial analysis of the power delay profile, mean delay, and RMS delay spread allows preliminary conclusions to be drawn that there is a significant impact...
-
Ultra-Miniaturized HMSIW Cavity-Backed Reconfigurable Antenna Diplexer Employing Dielectric Fluids with Wide Frequency Tuning Range
PublicationThis communication presents an ultra-miniaturized two-way frequency tunable antenna diplexer based on cavity-backed slots and dielectric fluids. The proposed antenna utilizes two half-mode substrate-integrated rectangular cavities loaded with slots and fluidic pockets. The conventional size reduction is achieved by employing half-mode cavities, whereas ultra-miniaturization is obtained by applying the slots, which provides additional...
-
Multifunctional Bandpass Filter/Displacement Sensor Component
PublicationThis paper presents the design and realization of a multifunctional bandpassfilter/displacement-sensor using an edge-coupled microstrip bandpass filter loaded by a pair of split ring resonators (SRRs). It is shown that while the structure acts as a bandpass filter at its operating frequency, the phase of the reflection coefficient from a movable loading resonator at the resonance frequency of the resonator can be used for displacement...
-
Three modes of electrochemical impedance spectroscopy measurements performed on vanadium redox flow battery
PublicationThis article presents an innovative approach to monitor working redox flow batteries using dynamic electrochemical impedance spectroscopy, diverging from the commonly sequential impedance methods carried out under potentiostatic or galvanostatic conditions close to the open circle voltage. The authors introduce a fresh variation of dynamic impedance measurement that leverages an amplitude-modulated multi-frequency alternating current...
-
Modelling and analysis of medium frequency transformers for power converters
PublicationThe evolutions in power systems and electric vehicles, related to the economic opportunities and the environmental issues, bring the need of high power galvanically isolated DC-DC converter. The medium frequency transformer (MFT) is one of its key components, enabled by the increasing switching frequency of modern power semiconductors like silicon carbide transistors or diodes. The increased operating frequency offers small...
-
Novel doubly perforated broadband microstrip branch-line couplers
PublicationTwo broadband compact doubly perforated hybrid couplers have been designed, manufactured, and measured. To improve frequency characteristics and to reduce circuit dimensions, two kinds of perforations have been introduced: the defected ground structures in the ground plane metallization and photonic bandgap cells in the strip metallization. Measurement results show essential miniaturization (~39% and ~36%) and enhancement of the...
-
Narrowband Transmission Quality in Presence of Modified IEEE 802.15.4a UWB Signal
PublicationThis paper presents results of measurement of narrowband transmission quality in presence of impulse radio UWB interference. In the first part of paper, unmodified IEEE 802.15.4a IR UWB signal is used. Then some modification of transmitted pulse sequence is proposed, which allow to reduce UWB power spectral density at frequency of narrowbandtransmission. Finally narrowband transmission quality in presence of modified ultrawideband...
-
Impedance spectra of ZnO varistor type 440 model A ver. M
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 680 model A M ver. 93
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 680 model O M ver. 65 13
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 680 model A M ver. xx
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model A ver. M
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model 0 ver. 89
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model O ver. 68
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 100 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 440 model O ver. 68
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 10 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 680 model O M ver. 65 60
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 10 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Wavelet transform analysis to assess oscillations in pial artery pulsation at the human cardiac frequency
PublicationPial artery adjustments to changes in blood pressure (BP)may last only seconds in humans. Using a novelmethod called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) in humans, we aimed to assess the relationship between spontaneous oscillations in BP and cc-TQ at frequencies between 0.5 Hz and 5 Hz. We hypothesized that analysis of...
-
Narrowband Transmission Quality in Presence of Modified IEEE 802.15.4a UWB Signal
PublicationThis paper presents results of measurement of narrowband transmission quality in presence of impulse radio UWB interference. In the first part of paper, unmodified IEEE 802.15.4a IR UWB signal is used. Then some modification of transmitted pulse sequence is proposed, which allow to reduce UWB power spectral density at frequency of narrowband transmission. Finally narrowband transmission quality in presence of modified ultrawideband...
-
The standard radiated immunity test of an astable multivibrator at a normative field strength
Open Research DataThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 80 MHz to 1 GHz are performed...
-
The conducted immunity test of a power supply unit in accordance with EMC standards
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz to 230 MHz are...
-
The electromagnetic field intensity in industrial buildings
Open Research DataThe dataset contains the results of measurements of electromagnetic fields, separately electric and magnetic, carried out at selected places in the building of an operating industrial enterprise.
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 2 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Kazimierz Darowicki prof. dr hab. inż.
PeopleStudia wyższe ukończyłem w czerwcu 1981 roku po zdaniu egzaminu dyplomowego i obronie pracy magisterskiej. Opiekunem pracy magisterskiej był dr hab. inż. Tadeusz Szauer. W roku 1991, 27 listopada uzyskałem stopień naukowy broniąc pracę doktorską zatytułowaną „Symulacyjna i korelacyjna analiza widm immitancyjnych inhibitowanej reakcji elektrodowej”. Promotorem pracy był prof. dr hab. inż. Józef Kubicki (Wydział Chemiczny...
-
Adaptive acoustic crosstalk cancellation in mobile computer device
PublicationThe cancellation of acoustic crosstalk is employed to enhance the stereo image in mobile listening conditions. A practical setup employing a mobile computer is employed. The adaptation of the crosstalk cancellation filter to the position of the listener's head is featured. The measurement evaluating the possibility of practical application of the method are described. The head and torso simulator was used for measurements. The...
-
Impedance spectra of ZnO varistor type 280 model O M ver. 89
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Ambient vibrations - footbridge over the Kolibkowski Stream in Gdynia, span P2
Open Research DataAmbient vibration tests carried out on the P2 span of the footbridge over the Kolibkowski Stream. The research was carried out using a set of 14 acceleration sensors - MEMS accelerometers TE 4332M3-002 and TE 4312M3-002, which allowed for simultaneous measurement and recording of 20 acceleration channels. These sensors are characterized by a natural...
-
Ambient vibrations - footbridge over the Kolibkowski Stream in Gdynia, span P3
Open Research DataAmbient vibration tests carried out on the P3 span of the footbridge over the Kolibkowski Stream. The research was carried out using a set of 14 acceleration sensors - MEMS accelerometers TE 4332M3-002 and TE 4312M3-002, which allowed for simultaneous measurement and recording of 20 acceleration channels. These sensors are characterized by a natural...
-
Ionospheric scintillations computation using real-time GPS observations
PublicationThe following paper presents the results of quasi-real-time determination of the values of phase scintillations indices at the period of ionospheric disturbances that occurred as a consequence of the Sun flares observed on March 7 and 9, 2012. Double-frequency observations with 1-second measurement interval from the EPN (EUREF Permanent Network) network sites located at high latitudes were used for the analysis. To determine the phase...
-
Fracture surface topography measurements analysis of low-alloyed corrosion resistant steel after bending-torsion fatigue tests
PublicationIn this paper, an assessment of a topography measurement method for fracture surfaces of 10HNAP steel after bending-torsion fatigue tests was performed. Surface roughness was measured by using a non-contact Focus Variation Microscopy (FVM) technique in which the non-measured points (NMPs) and outliers (spikes) were removed by the application of general methods. The results revealed, that the optical measurement method introduced...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 3 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on "unknown" object using 2-wire probe
Open Research DataThe dataset presents impedance spectrum of "black-box" object with interesting phase characteristics. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Noise spectral density computation based on finite element model of piezoceramic sensor
PublicationThe high sensitivity with wide bandwidth is required for sensor applications in non-destructive testing (NDT). The sensitivity of piezoceramic sensors demands to minimize their noise especially thermal noise, polarisation noise and low frequency 1/f noise,which are the main sources of voltage or current fluctuation in this sort of sensors. For simplicity, only the piezoceramic part of sensor was under study. the theoretical and...
-
Estimation of the uncertainty of the LEM CV 3-500 transducers processing function
PublicationThe paper presents the methodology for estimating uncertainty of a voltage transducer processing function based on the example of LEM CV 3-500 transducer. The analysis was performed using the method based on the GUM Guide propagation of uncertainty law and the Monte Carlo numerical method. The article also presents a comparative analysis of the results of a voltage measurement evaluation done using the Monte Carlo simulation method,...
-
Analysis of the instantaneous power signal for bearing diagnostics -bearing damaged
Open Research DataThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of a damaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Analysis of the instantaneous power signal for bearing diagnostics - bearing undamaged
Open Research DataThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of an undamaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Planar Microwave Bragg Reflector Resonant Dielectric Sensor
PublicationIn this paper, a periodic structure is used to design a microwave Bragg reflector with the help of hexagonal lattice, which provides a 5 GHz wide stopband between the low-pass band with cut-off frequency 2.6 GHz and the bandpass response with start and stop frequency 7.8 GHz and 10.5 GHz, respectively. A defect in lattice allows passing a narrowband signal at 6 GHz which is found, from the dispersion relation, to be in the region...
-
Pomiar ryzyka bankowego - propozycja typologii
PublicationW artykule zaproponowano typologię pomiaru ryzyk bankowych. Wyodrębnione kryteria podziału podejść do pomiaru ryzyka to: (1) pomiar bezpośredni/pośredni, (2) pomiar ex post/ex ante, (3) kryterium oparte o składnik ryzyka – częstotliwość, dotkliwość, ekspozycja, całościowa strata, (4) kryterium oparte o parametr rozkładu: pomiar wartości oczekiwanej/przeciętnej, pomiar rozproszenia, pomiar wartości skrajnych. Wśród motywów pomiaru...
-
Fuel cell noise data
Open Research DataMeasurement data of Hydrogen PEM fuel cels. The voltage fluctuations were measured over single cels of stack of 10 cels.
-
The conducted immunity test of an AC adaptor in accordance with EMC standards
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the ac adaptor PHILIPS DC power supply SBC 6654. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz...
-
Measurements of flicker noise in supercapacitor cells
PublicationFlicker noise (1/f-like noise) is often used to assess the quality of various materials and devices. This phenomenon has been observed in different electrochemical devices or reactions (e.g., smart windows, pitting corrosion events). In our exploratory studies we consider how to measure and utilize 1/f noise for the quality assessment of supercapacitors. This task requires special attention because of enormous capacitance of the...
-
Angle Tracking Observer for Filtering Rotor Position Estimates in Sensorless Electric Drives
PublicationSensorless electric drives use measurements of electrical quantities to estimate rotor position and speed. Measurement errors deteriorate the estimation accuracy, thus additional means are necessary to remove high-frequency components from estimated signals. This paper proposes to use an Angle Tracking Observer (ATO) for reducing noise in rotor position estimates, which is related to random errors in the measurements. A simplified,...
-
Mesoscopic impedance analysis of solid materials surface
PublicationSeveral techniques have been developed in order to characterize electrical properties of surfaces in micrometer/nanometer scale. Obtaining of the spatial distribution of sample resistance, capacitance or potential requires separate measurements performed in different scanning modes. On the other hand, analysis of the frequency response of investigated system enables determination of several physical quantities in single measurement...
-
Simulation of signal acquisition from a rotary flowmeter
Open Research DataThe dataset contains results of simulation measuring the flow of homogeneous substances by rotational flow meter: a moment of impulse at the output of flow meter, time between successive pulses, number of pulses counted from standard generator and relative error of measurement.
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during a sea voyage
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier at sea trials. The data were recorded during a sea voyage, under normal...
-
Novel fast non-linear electrochemical impedance method for corrosion investigations
PublicationThe paper presents a novel approach to corrosion rate monitoring using non-linear electrochemical impedance spectroscopy. The authors propose a new variant of non-linear impedance measurement using amplitude-modulated multi-frequency ac perturbation signal. It allows shortening of measurement duration so it is possible to monitor corrosion rate of the systems experiencing rapid changes. In this way a limitation resulting from lack...
-
Instantaneous power signal measurements for bearing diagnostics
Open Research DataBearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous current and voltage power supplied to the engines. Bearing damage causes the appearance of deformations, which are in the form of additional harmonic components...
-
The electrochemical response to BDD electrode functionalization with CD147 receptor
Open Research DataThis dataset contains the results of the electrochemical impedance spectroscopy (EIS) measurements of the boron-doped diamond (BDD) electrode functionalization with CD147 receptor. The functionalized electrode was then used for the electrochemical detection of the SARS-CoV-2 virus S1 protein.
-
The electrochemical response to BDD electrode functionalization with ACE2 receptor
Open Research DataThis dataset contains the results of the electrochemical impedance spectroscopy (EIS) measurements of the boron-doped diamond (BDD) electrode functionalization with ACE2 receptor. The functionalized electrode was then used for the electrochemical detection of the SARS-CoV-2 virus S1 protein.
-
The electrochemical response to BDD electrode functionalization with IgG2B receptor
Open Research DataThis dataset contains the results of the electrochemical impedance spectroscopy (EIS) measurements of the boron-doped diamond (BDD) electrode functionalization with IgG2B receptor. The functionalized electrode was then used for the electrochemical detection of the SARS-CoV-2 virus S1 protein.