Plasticity of Bead-On-Plate Welds Made with the Use of Stored Flux-Cored Wires for Offshore Applications
PublicationExtreme atmospheric conditions in the marine and offshore industry are harmful to engineering materials, especially to welded joints, and may cause degradation of their properties. This article presents the results of research on the plasticity of bead-on-plate welds made using two types of seamless, copper plated flux-cored wires. Before welding, spools with wire were stored for 1 month in two distinct locations with different...
-
The Influence of Microstructure on the Passive Layer Chemistry and Corrosion Resistance for Some Titanium-Based Alloys
PublicationThe effect of microstructure and chemistry on the kinetics of passive layer growth and passivity breakdown of some Ti-based alloys, namely Ti-6Al-4V, Ti-6Al-7Nb and TC21 alloys, was studied. The rate of pitting corrosion was evaluated using cyclic polarization measurements. Chronoamperometry was applied to assess the passive layer growth kinetics and breakdown. Microstructure influence on the uniform corrosion rate of these alloys...
-
Bearing estimation using double frequency reassignment for a linear passive array
PublicationThe paper demonstrates the use of frequency reassignment for bearing estimation. For this task, signals derived from a linear equispaced passive array are used. The presented method makes use of Fourier transformation based spatial spectrum estimation. It is further developed through the application of two-dimensional reassignment, which leads to obtaining highly concentrated energy distributions in the joint frequency-angle domain...
-
Investigation on polypropylene friction stir joint: effects of tool tilt angle on heat flux, material flow and defect formation
PublicationTool tilt angle (TTA) is a critical factor that can control material flow in polymeric materials' friction stir joining (FSJ). This study selected a TTA range between 0° to 4° for FSJ of polypropylene (PP) polymer sheet. A modified computational fluid dynamic (CFD) technique was implemented to gain a deep understanding of the effects of TTA during FSJ of PP. The PP joint's internal flow, defect formation, heat generation, and tensile...
-
Evaluating the influence of radiative heat flux on convective heat transfer from a vertical plate in air using an improved heating plate
PublicationThis article examines the influence of radiative heat flux on the accuracy of the results of free convective heat transfer in air. In order to carry out these tests, based on the experience gained during the operation of a plate heated on one side, compensated by a reverse heat loss flux counter-heater, a unique double-sided heating sandwich plate was designed and built, consisting of three thin epoxy resin plates reinforced with...
-
Magnetic flux leakage signals of near side defects measured with different velocities
Open Research DataThe dataset contains raw signals measured with the use of the magnetic flux leakage (MFL) technique. Linear Hall effect sensors A1324 were used to measure magnetic flux leakage. Three voltage signals were measured: Bx sensor output, Bz1 sensor output, and difference of Bz1 and Bz2 outputs. An output of a Bx sensor was directly proportional to the tangential...
-
Magnetic flux leakage signals of far side defects measured with different velocities
Open Research DataThe dataset contains raw signals measured with the use of the magnetic flux leakage (MFL) technique. Linear Hall effect sensors A1324 were used to measure magnetic flux leakage. Three voltage signals were measured: Bx sensor output, Bz1 sensor output, and difference of Bz1 and Bz2 outputs. An output of a Bx sensor was directly proportional to the tangential...
-
Advances in passive sampling in environmental studies
PublicationDozymetria pasywna stanowi użyteczne narzędzie wykorzystywane w monitoringu środowiskowym. W pracy zostały zawarte nowe rozwiązania i udoskonalenia istniejących próbników pasywnych oraz praktyczne ich wykorzystanie w monitoringu środowiskowym.
-
Electrochemical analysis of aluminium passive layer
PublicationZbadano proces pękania warstwy pasywnej na aluminium dla liniowo narastających naprężeń rozciągających oraz różnych warunków elektrochemicznych. Badania prowadzono w 0.1M NaCl metodą dynamicznej elektrochemicznej spektroskopii impedancyjnej przy różnych poziomach polaryzacji anodowej. Określono progową wartość naprężeń, przy której następowało zniszczenie warstwy pasywnej wskutek działania sił rozciągających.
-
Performance Evaluation of an Axial Flux Machine with a Hybrid Excitation Design
Publication -
Employment of passive sampling in monitoring indoor air quality in selected residences in a Tri-city area in Poland
PublicationTime-weighted average concentrations of selected volatile compounds were measured in chosen residences in a Tri-City area of Poland by means of passive sampling. The results were compared to those obtained by dynamic technique – sorption tubes filled with Tenax TA sorbent. Results obtained by employing the two techniques were similar. Total volatile organic compound (TVOC) parameters were also determined. An attempt was also...
-
Optimizing of target detection and tracking processes realized on consoles of passive sonar with linear towed antenna
PublicationThe long-range passive towed sonar was first modernised a few years ago. Building on operator experience over that period, a concept was developed of optimising the tasks performed by sonar operators, and improving forms of imaging to inform about object detection and support object tracking. The concept was implemented and successfully tested during ships’ manoeuvres. The optimisation of operator tasks was designed to keep listening...
-
A new approach in the calibration of passive samplersA new approach on the calibration of passive dosimeters for studies of indoor air (....--------ROZBIEŻNOŚĆ TYTUŁÓW-------------------------------------
PublicationPrzedstawiono problematykę kalibracji próbników pasywnych wykorzystywanych w Katedrze Chemii Analitycznej Wydz. Chemicznego PG do monitoringu jakości powietrza wewnętrznego. Proponowane podejście pozwala na oszacowanie wartości stałych kalibracyjnych, a tym samym oznaczenia stężeń związków od heksanu do dodekanu. Tak więc permeacyjne dozymetry pasywne mogą być wykorzystane w analogicznym zakresie jak próbniki aktywne.
-
The Dilemmas of Choosing a Suitable Technology for Low Energy and Passive Houses in the Context of their Overheating Issues
PublicationIn compliance with European Union directives, numerous countries are introducing increasingly stricter legal limits on the estimated energy consumption of newly designed residential buildings. However, the fact, that regulations and designers' efforts are focused on decreasing energy consumption (and consequently carbon dioxide emissions) only at the post-occupancy stage, may lead to a significant increase in the carbon footprint...
-
Visualisation forms in passive sonar with towed array
PublicationArtykuł dotyczy organizacji zobrazowań na monitorach modernizowanego w KSEM sonaru pasywnego z długą, holowaną za rufą okrętu, anteną akustyczną. We wprowadzeniu opisano strukturę takiego sonaru oraz sposób pozyskiwania i charakter odbieranych sygnałów jako podstawę organizowania zobrazowań efektów nasłuchu. Dalej opisano inne czynniki wpływające na organizację obrazów na monitorach sonaru tzn. zadania operatorów, organizację i...
-
Passive sampling techniques for monitoring pollutants in water
PublicationPraca przeglądowa poświęcona technice dozymetrii pasywnej. Omówiono charakterystykę wybranych próbników pasywnych wykorzystywanych w analityce zanieczyszczeń wody. Ponadto przedstawiono zalety i wady technik pasywnych oraz opisano obszar praktycznego zastosowania próbnikow pasywnych.
-
A fast algorithm for computing the flux around non-overlapping disks on the plane
Publication -
Non-Destructive Testing for the In Situ Assessment of the Ionic Flux in Cementitious Materials
Publication -
Experimental investigation on straight and u-bend double tube heat exchanger with active and passive enhancement methods
PublicationAuthors in this work want to demonstrate the possibility to increase the heat transfer efficiency by using simple wire coil inserts to create turbulent flow in the boundary layer as well as air blowing into the annulus of the pipe. In the study, Wilson plot approach was applied in order to estimate heat transfer coefficients for all heat exchanger (HX) configurations. The study focuses on experimental values of heat transfer coefficient...
-
Highly Reliable Passive RFID-Based Inductor–Capacitor Sensory System Strengthened by Solvatochromism for Fast and Wide-Range Lactate Detection
PublicationA passive radio frequency-identification-based inductor-capacitor (LC) lactate sensory system with a specific dye-containing interdigitated capacitor (IDC) in which the sensing signal is amplified by the solvatochromic effect is proposed. When a lactate solution contacts the IDC of the LC lactate sensor, the capacitance of the IDC changes, changing the resonance frequency of the sensor. This changes the oscillation frequency of...
-
Expedited Re-Design of Multi-Band Passive Microwave Circuits Using Orthogonal Scaling Directions and Gradient-Based Tuning
PublicationGeometry scaling of microwave circuits is an essential but challenging task. In particular, the employment of a given passive structure in a different application area often requires re-adjustment of the operating frequencies/bands while maintaining top performance. Achieving this necessitates utilization of numerical optimization methods. Nonetheless, if the intended frequencies are distant from the ones at the starting point,...
-
Architectural and Urban Planning Solutions for the Protection of Heritage Buildings in the Context of Terrorist Attacks: Following the Example of Passive Protection Systems
PublicationEvents in recent years showing numerous terrorist attacks raise awareness regarding the neces-sity of considering the safety of heritage buildings. The analysis of available data allows us to conclude that it is not possible to fully prevent terrorist attacks. On the other hand, it is possible to minimize the impact of such incidents through proper design of Passive Protection System (PPS) components. One possible architectural...
-
Developing assumptions for the tram noise attenuation passive system using the noise maps analysis method
PublicationThe paper presents experimental research carried out to determine the possible actions to reduce thenoise generated by trams in a highly urbanised area. A few design strategies affecting tram ride qualityhave been presented – especially in the aspect of the acoustic phenomena. Main sources of the noisein trams were characterised. The paper includes selected results of comprehensive...
-
Application of passive sampling techniques for monitoring the aquatic environment
PublicationDozymetry pasywne są coraz powszechniej stosowanym narzędziem do pobierania próbek analitów ze środowiska wodnego. W przypadku próbników pasywnych pobieranie analitów następuje na drodze swobodnego transportu masy przez membranę do medium zatrzymującego, na skutek różnicy potencjałów chemicznych analitów w medium zatrzymującym w próbniku i środowiskiem wodnym, w którym umieszczany jest próbnik. Największą zaletą stosowania próbników...
-
Bearing errors passive sonar stationary target location
PublicationPrzedstawiono metodę wyznaczania współrzędnych nieruchomego celu na podstawie namiarów wykonywanych w sonarze pasywnym. Określono wymagania odnośnie ruchu sonaru, przy których błędy wyznaczania współrzędnych są minimalne. Podano zależności umożliwiające analityczne wyznaczanie błędów współrzędnych. Poprawność wyników analizy potwierdzono eksperymentami numerycznymi.
-
Surrogate models and automated cad of passive microwave components
PublicationW pracy pokazane zostały techniki modelowania złożonych układów elektronicznych wysokiej częstotliwości. Modele zastępcze mają postać sparametryzowanych modeli matematycznych tworzonych za pomocą schematów interpolacyjnych lub skupionych, pasywnych układów zastępczych dedykowanych analizie w dziedzinie czasu. Do konstrukcji modeli wykorzystywane są wyniki symulacji elektromagnetycznych, co pozwala na osiągnięcie lepszej dokładności...
-
Bistatic passive radar simulator with spatial filtering subsystem
Publication -
Algorithms for passive detection of moving vessels in marine environment
Publication -
Roll respose of ship fitted with passive stabilizing tank.
PublicationPrzedstawiono fizyczny i matematyczny model kołysań statku z biernym zbiornikiem stabilizacyjnym. Wyprowadzono równania ruchu i podano ich rozwiązania. Określono najistotniejsze zalecenia projektowe w oparciu o uzyskane rozwiązania. Wskazano kierunek poszukiwania optymalnych rozwiązań dla układu statek-bierny zbiornik stabilizacyjny.
-
Passive sampling and/or extraction techniquesin environmental analysis: a review
PublicationPrzedstawiono przegląd literaturowy dotyczący pasywnych technik izolacji i wzbogacania analitów z matryc środowiskowych, takich jak powietrze, woda czy gleba. Zwrócono uwagę na rosnącą rolę technik pasywnych w monitoringu środowiskowym oraz zaprezentowano krótki rys historyczny rozwoju tych technik.
-
The effect of tensile stresses on aluminium passive layer durability
PublicationW niniejszej pracy przedstawiono wyniki badań DEIS dotyczących wpływu naprężeń rozciągających na trwałość warstwy pasywnej aluminium A91050, prowadzonych w środowisku chlorków w temperaturze pokojowej.Zastosowana technika pozwoliła na wyznaczenie krytycznej wartości wydłużenia, przy której doszło do pęknięcia warstwy pasywnej na badanym stopie.
-
Nonlinear control of induction motor in field weakning region with consideration of stator flux
PublicationMetody nieliniowgo sterowania mogą poprawić właściwości silnika indukcyjnego w stanach przejściowych wektora strumienia. Badano sterowanie oparte na modelu multiskalarnym silnika indukcyjnego w zakresie osłabiania pola. Dwie nowe zmienne wejściowe pojawiające się w modelu multiskalarnym są równe czynnej i biernej mocy silnika. Pokazano, że te wielkości mogą byc kompensowane, jeżeli rozważane są jako mierzone zakłócenia. Maksymalny...
-
Influence of circuit breaker operation upon transformeros residual flux and inrush current
PublicationPrzedstawiono model i wyniki obliczeń prądu i strumienia magnetycznego w układzie zawierającym transformator trójfazowy i wyłącznik. Opracowano obwodowy model łącznika z łukiem elektrycznym. Model łuku zbudowano w oparciu o jego statyczną charakterystykę prądowo-napięciową z uwzględnieniem uproszczonej charakterystyki dynamicznej. Przeprowadzone symulacje wykazały, że wartość maksymalna prądu włączania transformatora zależy zarówno...
-
Trends and variability of the atmosphere–ocean turbulent heat flux in the extratropical Southern Hemisphere
Publication -
Numerical calculation of three-phase transformer's residual flux in ATP and PSpice programs.
PublicationW artykule przedstawiono analizę przebiegów prądu i strumienia magnetycznego podczas wyłączania transformatora energetycznego, wykonaną w celu określenia strumieni szczątkowych. Wykorzystano do tego celu modele obwodowe zbudowane w oparciu o programy symulacyjne ATP (Alternative Transients Program) i PSpice. Wyniki obliczeń okazały się bardzo zbliżone dla obu modeli. Przy ich wykorzystaniu obliczono strumienie szczątkowe w kolumnach...
-
Storage of High-Strength Steel Flux-Cored Welding Wires in Urbanized Areas
PublicationThe condition of the consumables is a key factor determining the waste reduction in the welding processes and the quality of the welded joint. The paper presents the results of tests of four types of fux-cored wires dedicated for welding high-strength steels, stored for 1 month and 6 months in Poland in two urbanized areas: in a large seaside city (Gdańsk) and in Warsaw, located in the center of the country. The wires were subjected...
-
Stability of a proportional observer with additional integrators on the example of the flux observer of induction motor
PublicationArtykuł opisuje zagadnienia związane ze stabilnością proporcjonalnego obserwatora Luenbergera z dodatkowymi integratorami
-
Near-Field Wireless Sensing of Plastics and Papers Using Frugal Peel-Off Passive Tag
PublicationThis article presents a novel frugal approach of testing plastics and papers using a near-field microwave sensing technique with a peel-off tag. The proposed sensing technique involves two electrical entities: the sensor, which may be regarded as a reader, and a disposable tag. The reader is a modified design of a gap-coupled microstrip line (GCML) sensor, while the passive tag is a standard double-ring complementary split-ring...
-
Comparative analysis of seismic response reduction in multi-storey buildings equipped with base isolation and passive/active friction-tuned mass dampers
PublicationThis study presents an innovative approach to mitigating seismic responses in multi-storey buildings equipped with a base-isolation (BI) system and passive friction-tuned mass dampers (PFTMDs). The key innovation lies in the combined use of a BI system and a PFTMD system, as well as the activation of this mechanical system by controllers. Additionally, the research design optimizes the parameters of these devices specifically for...
-
Kinetic flux vector splitting scheme for solving non-reactive multi-component flows
Publication -
Robust flux observer system with sliding mode and fuzzy logic control of Induction Motors
PublicationW pracy przedstawiono implementację nowego obserwatora strumienia wirnika silnika indukcyjnego zastosowanego w układzie sterowania polowo zorientowanego ze sterowaniem ślizgowym. Proponowany system jest niewrażliwy na zmiany rezystancji stojana silnika w wyniku zastosowania korekcyjnego sprzężenia zwrotnego. Przedstawiono porównanie układów z oraz bez zastosowania sterowania ślizgowego. Zamieszczono wyniki badań symulacyjnych...
-
Obliczanie indukcyjnych układów grzejnych z wykorzystaniem interfejsu API komercyjnego pakietu Flux
Publication -
Technology of laser deposition of narrow bead overlays using solid and flux-cored wires
Publication -
Acoustic signal processing in passive sonar system with towed array
PublicationW referacie opisano przetwarzanie sygnałów akustycznych w pasywnym systemie hydrolokacyjnym. W pojęciu ''przetwarzanie sygnałów akustycznych'' mieszczą się wszelkie operacje wykonywane na sygnałach analogowych tj. wzmacnianie, filtracja i próbkowanie, jak również operacje na sygnałach cyfrowych uzyskanych w procesie próbkowania. Do operacji cyfrowych wykonywanych w systemie zalicza się synchronizację, konwersję, sortowanie, wytwarzanie...
-
Buck-Boost Inverters with Symmetrical Passive Four-terminal Networks
Publication -
Permeation passive sampling as a tool for the evaluation of indoor air quality
PublicationOkreślono stężenie średnie ważone w czasie wybranych lotnych związków organicznych w powietrzu ośmiu pomieszczeniach mieszkalnych na terenie miasta Gdańska. Do pobierania próbek analitów z powietrza wewnętrznego zastosowano permeacyjny dozymetr pasywny typu pudełkowego oraz technikę dynamiczną (urządzenie przepływowe z rurką sorpcyjną). Porównano wyniki uzyskane w wyniku zastosowania w/w technik pobierania próbek analitów.
-
Influence of the initial void ratio on the evolution of the passive earth pressure
PublicationW artykule przedstawiono wyniki numerycznej analizy wpływu rozkładu początkowego wskaźnika porowatości i fluktuacji bieżącego wskaźnika porowatości w materiałach granulowanych na powstawanie lokalizacji odkształceń. Obliczenia wykonano dla ściskania dwuosiowego stosując metodę elementów skończonych na bazie mikropolarnego prawa hipoplastycznego.
-
Pobieranie próbek opadów atmosferycznych do analizy. Opis stosowanych próbników. Sampling of atmospheric precipitation for the analysis. Description applied samplers
PublicationW pracy przedstawiono opis podstawowych typów próbników wykorzystywanych do pobierania próbek opadów atmosferycznych (woda deszczowa, wody spływne, mgła) oraz tok postępowania analitycznego z pobranymi próbkami w celu oznaczenia szerokiego spektrum składników śladowych.
-
Experimental and Computational Fluid Dynamics Studies on Straight and U-Bend Double Tube Heat Exchangers with Active and Passive Enhancement Methods
PublicationIn this work, the authors wanted to demonstrate the possibility to increase the heat transfer efficiency by using simple wire coil inserts to create turbulent flow in the boundary layer as well as air blowing into the annulus of the pipe. Experimental investigations were carried out for four heat exchanger constructions, i.e., plain double tube, turbulized double tube, plain U-bend double tube, U-tube with turbulator, plain double...
-
Application of the Harmonic Balance Method for Spatial Harmonic Interactions Analysis in Axial Flux PM Generators