displaying 1000 best results Help
Search results for: STRAY-CURRENT CORROSION
-
Feedback Control of Doubly-Fed Generator Connected to Current Source Converter
PublicationDoubly-fed induction generator (DFIG) system supplied by current source converter (CSC) is considered in this article. The DFIG can work in two independent modes: AC grid connection and stand-alone mode. The DFIG is connected to the ac grid directly through its stator and the CSC links the rotor side. In this mode, the active and reactive powers of the DFIG must be controlled. This article proposes two control system structures...
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Current-based higher-order spectral covariance as a bearing diagnostic feature for induction motors
PublicationConducting the diagnosis of induction motors remotely by analyzing the supply current is an attractive prospect with the lack of access to the engine. Currently, there is no solution, based on analysis of the current, the credibility of which would allow its use in industry. The statistics of bearing failures in induction motors indicate that they constitute more than 40% of induction motor damage, therefore, bearing diagnosis...
-
Impact of thermal backfill parameters on current-carrying capacity of power cables installed in the ground
PublicationProper design of power installations with the participation of power cables buried in homogeneous and thermally well-conductive ground does not constitute a major problem. The situation changes when the ground is non-homogeneous and thermally low-conductive. In such a situation, a thermal backfill near the cables is commonly used. The optimization of thermal backfill parameters to achieve the highest possible current-carrying capacity...
-
Nonlinear Control of a Doubly Fed Generator Supplied by a Current Source Inverter
PublicationNowadays, wind turbines based on a doubly fed induction generator (DFIG) are a commonly used solution in the wind industry. The standard converter topology used in these systems is the voltage source inverter (VSI). The use of reverse-blocking insulated gate bipolar transistor (RB-IGBT) in the current source inverter topology (CSI), which is an alternative topology, opens new possibilities of control methods. This paper presents...
-
Marine polymers in tissue bioprinting: Current achievements and challenges
PublicationBioprinting has a critical role in tissue engineering, allowing the creation of sophisticated cellular scaffolds with high resolution, shape fidelity, and cell viability. Achieving these parameters remains a challenge, necessitating bioinks that are biocompatible, printable, and biodegradable. This review highlights the potential of marine-derived polymers and crosslinking techniques including mammalian collagen and gelatin along...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Corrosion Science and Technology-Korea
Journals -
Corrosion Science and Protection Technology
Journals -
Zairyo to Kankyo/ Corrosion Engineering
Journals -
High Temperature Corrosion of Materials
Journals -
The microstructure of AA5754 alloy under corrosion in alkaline media (pH=11) with 20 mM of various carboxylic acids
Open Research DataThis dataset contains scanning electron microscopy (SEM) micrographs taken for polished aluminum AA5754 alloy samples, exposed for 100 min in bicarbonate buffer (pH=11) with the addition of 20 mM of carboxylic acids, namely: citric acid, malic acid, maleic acid, succinic acid, tartaric acid, tricarballylic acid and serine. The goal of this study was...
-
The microstructure of AA5754 alloy under corrosion in alkaline media (pH=11) with 4.5 mM of various carboxylic acids
Open Research DataThis dataset contains scanning electron microscopy (SEM) micrographs taken for polished aluminum AA5754 alloy samples, exposed for 100 min in bicarbonate buffer (pH=11) with the addition of 4.5 mM of carboxylic acids, namely: citric acid, malic acid, maleic acid, succinic acid, tartaric acid, tricarballylic acid and serine. The goal of this study was...
-
Effect of cobalt addition on the corrosion behaviorof near equiatomic NiTi shape memory alloy in normal saline solution: electrochemical and XPS studies
PublicationThe electrochemical and corrosion (uniform and localized) behavior of a binary Ni52Ti48 shape memory alloy (SMA) and two ternary Ni52Ti48-xCox (x = 1.5 and 4.0 wt.%) SMAs were studied. Measurements were conducted in 0.9% NaCl solution at 37 oC employing various electrochemical methods. These include: linear polarization resistance (LPR), linear sweep voltammetry (LSV), chronoamperometry and dynamic electrochemical impedance spectroscopy...
-
Characterization of corrosion in reinforced concrete beams using destructive and non-destructive tests
PublicationThe paper presents both non-destructive and destructive experimental tests on steel-reinforced concrete beams subjected to electrochemical corrosion. To examine the condition and behavior of the specimens, destructive tests were carried out, i.e., a three-point bending together with a modulated ultrasonic wave test. In addition, a series of non-destructive experiments were conducted, such as the potential measurement method, low-frequency...
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublicationA novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...
-
Impact of digital signal processing on FOC current feedback in high-speed PMSM drive
PublicationIn applications where size and weight of the electric motor are among major design concerns, Permanent Magnet Synchronous Motors (PMSMs) with wide operational speed-range are commonly preferred. Due to limited inverter switching frequency, high-speed operation of a drive results in a low ratio between the switching frequency and the fundamental frequency of motor voltage. Such operating conditions have been recently identified...
-
Evaluation of citric acid corrosion inhibition efficiency and passivation kinetics for aluminium alloys in alkaline media by means of dynamic impedance monitoring
PublicationA novel approach is proposed for constructing the adsorption isotherm in corrosion studies, based on a well-known interaction between citric acid and aluminium in alkaline electrolytes. Our approach utilizes the instantaneous impedance measurements via Dynamic Electrochemical Impedance Spectroscopy in galvanostatic mode (g-DEIS). Unlike other common tools, g-DEIS delivers exact information about the concentration required for full...
-
Microstructure and corrosion behaviour of carbon steel and ferritic and austenitic stainless steels in NaCl solutions and the effect of p-nitrophenyl phosphate disodium salt
PublicationThe microstructure and corrosion behavior of carbon steel (CSA516) and ferritic (SS410) and austenitic (SS304L) stainless steels were studied and compared. Corrosion tests were carried out in 0.5 M NaCl solutions. Rates of corrosion were monitored based on weight loss, Tafel extrapolation and linear polarization resistance (LPR) methods. Rates of corrosion were ranked following the order: CSA516 >> SS410 > SS304L. The impact of...
-
High-temperature Corrosion of ~ 30 Pct Porous FeCr Stainless Steels in Air: Long-Term Evaluation Up to Breakaway
PublicationIn this work, a long-term (up to 6000 hours) corrosion evaluation of three porous (~ 30 pct of initial porosity) ferritic iron-chromium alloys with different Cr contents (20, 22, and 27 wt pct of Cr) was carried out at 600 C, 700 C, 800 C, and 900 C in air. Mass gain measurements and SEM analyses revealed that at temperatures above 600 C, all alloys exhibit breakaway corrosion, whereas at 600 C, none of the alloys were heavily...
-
Current trends in the field of steganalysis and guidelines for constructions of new steganalysis schemes
PublicationThe paper concerns blind steganalysis techniques in the passive steganalysis scenario designed to detect the steganographic cover modification schemes. The goal is to investigate the state-of-art in the field of steganalysis, and, above all, to recognize current trends existing in this field and determine guidelines for constructions of new steganalysis schemes. The intended effects are to examine the possibilities for the development...
-
Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublicationOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
SEM micrographs of cavitation erosion-corrosion of aluminium alloy 2024 with anodic polarization
Open Research DataThe dataset contains Scanning Electron Micrographs of aluminium alloy 2024 samples made after cavitation erosion-corrosion exposure using a vibratory transducer (in accordance with ASTM G32). The experiment duration was 240 min, with cyclic cavitation exposure in on/off cycles 30s:30s. The electrolyte was 0.1 M KNO3 solution. Some samples were anodically...
-
Functionalization of graphene oxide coatings with phosphorus atoms and their corrosion resistance in sodium chloride environment
PublicationIn this work, we compared corrosion resistance of graphene oxide, and phosphorus functionalized reduced graphene oxide coatings obtained as a result of electrophoretic deposition on the copper substrate. Doping graphene oxide with phosphorus atoms was performed by a hydrothermal method in the presence of different amounts of phosphoric acid. Structural studies confirmed the insertion of phosphorus atoms into the graphene oxide...
-
Output voltage, current and DC-link voltages under SPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The Carrier-Based Pulse-Width Modulation (CBPWM) technique was...
-
Output voltage, current and DC-link voltages under SVPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The comparison studies between proposed Space Vector Pulse-Width...
-
Failures and a concept of corrosion protection system for spiral classifiers at KGHM Polska Miedź S.A. Ore Concentration Plant
PublicationThe Ore Concentration Plant, where the process of flotation is carried out as well as the final production of copper concentrate, plays a key role in the entire production line of KGHM Polska Miedź S.A. Majority of operations related to the run-of-mine preparation to copper flotation enrichment are carried out in a water environment. The maintaining of production process continuity requires to pursue minimisation of many production...
-
Corrosion-inhibiting effect of Mimosa extract on brass-MM55 corrosion in 0.5 M H2SO4 acidic media
PublicationEkstrakt z mimosy był badany jako inhibitor korozji mosiądzu MM55 przy użyciu Elektrochemicznej Spektroskopii Impedancyjnej oraz techniki polaryzacyjnej. Badania te wykazały, że ekstrakt z mimosy wykazuje właściwości inhibitora anodowego. Własności inhibicyjne badanego ekstraktu rosły wraz ze wzrostem stężenia inhibitora w kwasie, związano to ze wzrostem adsorpcji cząsteczek inhibitora na powierzchni metalu.
-
Tripping of F-type RCDs for sinusoidal residual current with superimposed smooth DC component
PublicationRecent trends in green energy development make that photovoltaics and electric vehicles are applied on an increasing scale. In both photovoltaic and electric vehicle charging installations, a significant value of DC component of the earth fault current may appear, which is a challenge, in particular, for commonly used residual current devices (RCDs). This paper presents results of the laboratory test on the operation of F-type...
-
Evaluation of adhesion strength, corrosion, and biological properties of the MWCNT/TiO2 coating intended for medical applications
PublicationMulti-wall carbon nanotube (MWCNT) coatings are gaining increasing interest because of their special properties used in many science fields. The titania coatings are known for their improvement of osteoblast adhesion, thus changing the surface architecture. Bi-layer coatings comprising 0.25 wt% of the MWCNTs and 0.30 wt% of titania (anatase structure) were synthesized in a two-stage procedure using the electrophoretic deposition...
-
Sensorless IPMSM drive with rotor position estimator based on analysis of phase current derivatives
PublicationThis paper describes a sensorless Interior Permanent Magnet Synchronous Motor (IPMSM) drive designed for traction applications. Wide-speed sensorless operation is provided with the use of three methods of rotor position estimation designed for: a standstill, low- and high-speed range. The paper focuses on the high-speed estimation algorithm. The estimator uses the derivatives of motor phase currentsresulting from PWM modulation...
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublicationA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
Voltage and Current Unbalance Reduction in Power Networks with Distributed Generation and Electric Vehicles
PublicationThe current development of prosumer microsources and the expected spread of electric vehicles may cause the appearance of significant current and voltage unbalance in low-voltage (LV) networks. This unbalance, which is an unfavorable phenomenon, may occur when using single-phase photovoltaic (PV) microsources and single-phase home chargers for electric vehicles. This paper presents a proposal for the symmetrization of the LV network...
-
Elimination of the negative effect of earth fault current higher frequency on tripping of residual current devices
PublicationCzęstotliwość prądu różnicowego większa niż 50/60 Hz ma niekorzystny wpływ na wyzwalanie wyłączników różnicowoprądowych. Przy zwiększonej częstotliwości prądu różnicowego rzeczywisty prąd zadziałania wyłączników zwiększa się, a niektóre z nich w ogóle nie wyzwalają. W artykule omówiono główne przyczyny zwiększenia się prądu zadziałania wyłączników różnicowoprądowych oraz przedstawiono sposób eliminacji niekorzystnego wpływu zwiększonej...
-
Influence of process of straightening ship hull structure made of 316L stainless steel on corrosion resistance and mechanical properties
PublicationThe AISI 316L type steel belongs to the group of chromium-nickel stainless steels. They are determined according to European standards as X2CrNiMo17-12-2 and belong to the group of austenitic stainless steels. Steels of this group are used for elements working in seawater environments, for installations in the chemical, paper, and food, industries, for architectural elements, and many others. The chemical composition of corrosion-resistant...
-
CFD-based evaluation of current-carrying capacity of power cables installed in free air
PublicationEvaluation of current-carrying capacity of power cables and selection of cross-sectional area of their conductors are mainly performed in accordance with requirements of EN, IEC or IEEE standards. However, these standards do not provide all methods of cables installation and location which occur in practice. Thus, in some cases, performance of advanced modeling of various thermal phenomena, affecting power cables current-carrying...
-
The influence of the motor filtrers on harmonic current emmision in the pro-ective connection of drive systems.
PublicationThis paper contains detailed analysis of currents in protective wire in engine supplied from frequency converter without any external filters added. It was found that the peak value of current in protective conductor of engine was about 1500 mA at frequencies 5 Hz 50 Hz. In the continuation of research the dU/dt type motor filter and the sinusoidal filter were tested. It was found that the current in protective wire decreased...
-
EVALUATION OF CAUSES OF CORROSION OF PLATE HEATEXCHANGER
PublicationPrzeprowadzono analizę zniszczeń korozyjnych wykrytych na płycie wymiennika ciepła stosowanego do chłodzenia silnika głównego statku. Stwierdzono obecność wżerów korozyjnych oraz korozji szczelinowej. Przedstawiono możliwe przyczyny wystąpienia w.w. uszkodzeń.
-
A review of applications of ellipsometry in corrosion research
PublicationElipsometria jest to nieinwazyjna i bardzo dokładna technika pomiarowa znajdująca coraz więcej zastosowań w badaniach korozyjnych. Poglądowo przedstawiono aktualne zastosowania pomiarów elipsometrycznych. Przeglądu dokonano pod kątem przydatności elipsometrii do wyznaczania grubości oraz charakterystyki optycznej cienkich warstewek pasywnych pokrywających powierzchnię różnych metali. Opisano zastosowanie pomiarów elipsometrycznych...
-
The adaptive backstepping control of PMSM supplied by current source inverter for the field weakening region
PublicationThe sensorless control system of permanent magnet synchronous motor PMSM supplied by current source inverter for field weakening operation is presented in this paper. The adaptive backstepping control system and the backstepping speed observer are presented. The control system is based on multi-scalar variables. The control variables are: dc-link voltage and the output current vector pulsation. The control system was named voltage...
-
Wear estimation of current collector contact strips by analysis of a 3D scanning results
PublicationThe technical condition of current collector contact strips is very important when operational reliability of railway transportation is considered. The authors proposed a novel measurement system based on a 3D camera to register the shape and dimensions of the current collector contact strips surface. The system was installed above the railway track for tests in target ambient. During the trial operation a few dozen of contact...
-
Electrical safety in low-voltage DC microgrids with B-type residual current devices
PublicationResidual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...
-
Modal analysis of railway current collectors using Autodesk Inventor
PublicationThe paper presents the results of modal analysis of railway current collector type 160EC. In the first place, the analysis was carried out analytically for a simplified two lumped mass pantograph model. Then numerical analysis was conducted in the Autodesk Inventor (AI) on the prepared multibody model using the AI modal analysis algorithm, which is based on the finite element method (FEM). Model elements which are most relevant...
-
Impact of Low Switching-to-Fundamental Frequency Ratio on Predictive Current Control of PMSM: A simulation study
PublicationPredictive current control algorithms for permanent magnet synchronous (PMSM) drives rely on an assumption that within short intervals motor currents can be approximated with linear functions. This approximation may result either from discretizing the motor model or from simplifications applied to the continuous-time model. As the linear current approximation has been recognized as inaccurate in case when the drive operates with...
-
Stability Analysis of Shunt Active Power Filter with Predictive Closed-Loop Control of Supply Current
PublicationThis paper presents a shunt active power filter connected to the grid via an LCL coupling circuit with implemented closed‐loop control. The proposed control system allows selective harmonic currents compensation up to the 50th harmonic with the utilization of a model‐based predictive current controller. As the system is fully predictive, it provides high effectiveness of the harmonic reduction, which is proved by waveforms achieved...
-
Oxylipin profiling for clinical research: Current status and future perspectives
PublicationOxylipins are potent lipid mediators with increasing interest in clinical research. They are usually measured in systemic circulation and can provide a wealth of information regarding key biological processes such as inflammation, vascular tone, or blood coagulation. Although procedures still require harmonization to generate comparable oxylipin datasets, performing comprehensive profiling of circulating oxylipins in large studies...
-
Complete Mesogastric Excisions Involving Anatomically Based Concepts and Embryological-Based Surgeries: Current Knowledge and Future Challenges
Publication -
Numerical modelling and analysis of steel specimens subjected to marine immersed corrosion and tensile load
PublicationThe present study develops numerical models to analyse the behaviour of steel specimens subjected to marine immersed corrosion degradation and tensile load. The finite element method with the use of the explicit dynamic solver LS-DYNA, satisfying the quasi-static conditions, is employed. Two numerical models are developed, where in the first one, the scans of surfaces gathered from corroded plate specimens are implemented directly...
-
Cannabinoids: Challenges, opportunities and current techniques towards its extraction and purification for edibles
PublicationDue to the multiple health benefits associated with the consumption of cannabinoids, there is a current trend on continuing to explore their biological properties. Cannabidiol (CBD) is likely to be the most investigated endocannabinoid from the cannabis plant. Unfortunately, the purification of CBD from its natural source and psychotropic analogue (tetrahydrocannabinol, THC) is timely challenging for the research community based...