FFT analysis of temperature modulated semiconductor gas sensor response for the prediction of ammonia concentration under humidity interference
PublicationThe increasing environmental contamination forces the need to design reliable devices for detecting of the volatile compounds present in the air. For this purpose semiconductor gas sensors, which have been widely used for years, are often utilized. Although they have many advantages such as low price and quite long life time, they still lack of long term stability and selectivity. Namely, environmental conditions have significant...
-
Data from 76- to 81-GHz mmWave Sensor located at S7 road
Open Research DataThe set consists data recorded employing IWR1642 mmWave sensor from Texas Instruments. The purpose of the experiment was to detect vehicles and their speed in real conditions – at S7 road, near Dworek village (54°14'40.0"N 18°59'59.0"E).
-
Enhancing electrochemical properties of an ITO-coated lossy-mode resonance optical fiber sensor by electrodeposition of PEDOT:PSS
PublicationA sensor working in multiple domains may offer enhanced information about the properties of an investigated analyte, including those containing biological species. It has already been shown that a dual-domain sensing capability, i.e., in optical and electrochemical domains, can be offered by lossy-mode resonance (LMR) sensors based on indium-tin-oxide (ITO) thin film. The spectral response of the LMR sensors depends on the refractive...
-
Low-volume label-free SARS-CoV-2 detection with the microcavity-based optical fiber sensor
PublicationAccurate and fast detection of viruses is crucial for controlling outbreaks of many diseases; therefore, to date, numerous sensing systems for their detection have been studied. On top of the performance of these sensing systems, the availability of biorecognition elements specific to especially the new etiological agents is an additional fundamental challenge. Therefore, besides high sensitivity and selectivity, such advantages...
-
A novel sensor for measuring temperature profile during the thermoablation
PublicationAbstract — A novel approach for monitoring a temperature distribution inside a tissue during thermoablation is presented in the paper. A thermal profile is measured using a set of serially connected thermistors each bypassed by a capacitor. This technique allows a two-wire and simultaneous multi- point measurements using a multi-frequency measurement of electrical impedance. It is...
-
Pattern matching localization in ZigBee wireless sensor networks.
PublicationLokalizacja typu Pattern matching w sieciach sensorów bezprzewodowych ZigBee.Prezentacja metod implementacji algorytmów lokalizacji. Praktyczne zastosowanie i testowanie lokalizacji sieci ZigBee.
-
Electrochemical sensor for measurement of volatile organic compounds in air
PublicationPrzedstawiono rezultaty badań prototypowego czujnika do oznaczania mrówczanu etylu i formaldehydu w powietrzu. Określono czułość wskazań czujnika i jego granice oznaczalności wykorzystując jako techniki detekcyjne pulsową woltamperometrię różnicową (DPV) oraz woltamperometrię fali prostokątnej (SWV). Elektrodę roboczą i przeciwelektrodę stanowiły elektrody z Pt. Elektrolitem wewnętrznym była ciecz jonowa (chlorek 1-heksylo,3-metyloimidazolinowy)....
-
Electrical properties of polymer humidity sensor based on polyethyleneimine.
PublicationW pracy przedstawiono wyniki badań amperometrycznych właściwości czujników wilgotności na bazie PEI. Pokazano, że przepływ prądu jest wynikiem reakcji elektrodowej na anodzie.
-
Targed tracking with adaptive fusionof multiple sensor measurements.
PublicationW pracy przedstawiono metodę adaptacyjnej selekcji pomiarów z wielu radarów wykorzystywanych w procesie integracji pomiarów dla śledzenia obserwowanego obiektu. W przypadku dużego zróżnicowania dokładności pomiarów pochodzących z różnych radarów, rezultaty integracji pomiarów nie różnią się znacząco od wyników śledzenia opartego na pomiarach z najbardziej dokładnego źródła.
-
Wave propagation in a sensor/actuator diffusion bond model
Publication -
Optical Diffraction Strain Sensor Prepared by Interference Lithography
Publication -
Optimal placement of IMU sensor for the detection of children activity
PublicationIn this paper an investigation to determine the optimal placement of IMU sensors for the purpose of children characteristic activity detection is presented. The article compares four different placement of two IMU sensors on human body. Ten healthy volunteers participated within the study. Data were collected firstly from two wireless 9-axial IMU sensors placed at the left and right wrists, then sensors were placed at lower back...
-
<title>LabWindows: tool and environment for sensor design</title>
Publication -
New Manufacturing Method Of Sensor Oriented Optical Fibers
Publication -
Luminescent Polymer Optical Fibre Sensor for Temperature Measurement
Publication -
Active glasses as the luminescent sources of radiation for sensor applications
Publication -
Analytical characteristics of a new amperometric sulfur dioxide sensor
PublicationZaprojektowano i skonstruowano wyposażony w układ trójelektrodowy amperometryczny czujnik ditlenku siarki. Elektroda pracująca czujnika była napylona bezpośrednio na powierzchnię membrany. Zbadano charakterystyki czujnika z membranami z mikroporowatego Teflonu oraz Nafionu. Porównano parametry statyczne i dynamiczne tych czujników wypełnionych roztworami elektrolitów wewnętrznych, zawierających dodatek dimetylosulfotlenku.
-
Localization in wireless sensor networks based on zigbee platform
PublicationW artykule porównano dwie różne metody lokalizacji w sieciach sensorów bezprzewodowych. Jedną z metod jest implementacja sprzętowa algorytmu w układzie nadawczo odbiorczym CC2431. Drugą metodą jest implementacja programowa. Wyniki testów przeprowadzonych na otwartym terenie oraz w pomieszczeniach zamkniętych zostały przedstawione i porównane w pracy.
-
Analog multiplier for a low-power integrated image sensor
PublicationArtykuł przedstawia nowe podejście do projektowania tanich niskomocowych zintegrowanych sensorów optycznych. W odróżnieniu od wcześniej stosowanych rozwiązań opartych na masowym przetwarzaniu równoległym, zaproponowany mnożnik macierzowy charakteryzuje się korzystniejszymi cechami. Proponowane rozwiązanie, chociaż mniej elastyczne w sensie liczby możliwych do zaimplementowania algorytmów wstępnej obróbki obrazu, cechuje się znaczącą...
-
Analog multiplier for a low-power integrated image sensor
PublicationArtykuł przedstawia nowe podejście do projektowania tanich niskomocowych zintegrowanych sensorów optycznych. W odróżnieniu od wcześniej stosowanych rozwiązań opartych na masowym przetwarzaniu równoległym, zaproponowany mnożnik macierzowy charakteryzuje się korzystniejszymi cechami. Proponowane rozwiązanie, chociaż mniej elastyczne w sensie liczby możliwych do zaimplementowania algorytmów wstępnej obróbki obrazu, cechuje się znaczącą...
-
Distributed Trust Management Model for Wireless Sensor Networks
Publication -
Wireless data transmission for fiber optical sensor system
PublicationW artykule opisano możliwość wykorzystania bezprzewodowego systemu transmisji danych do transmisji sygnałów z czujników światłowodowych.
-
A model of the response of the MGS-6 gravity sensor to tilting
PublicationThe reliable interpretation of the measurements made by the Micro-g marine gravimetric system (MGS-6) depends on how the temporary changes of the scale coefficients such as gravimeter scale factor, vertical cross-coupling (VCC) effect, tiltmeter cross and tiltmeter long are compensated for during the signal analysis. The listed coefficients cannot be determined from readings during the measurements or by analysing the final data....
-
Localization of sound sources with dual acoustic vector sensor
PublicationThe aim of the work is to estimate the position of sound sources. The proposed method uses a setup of two acoustic vector sensors (AVS). The intersection of azimuth rays from each AVS should indicate the position of a source. In practice, the result of position estimation using this method is an area rather than a point. This is a result of inaccuracy of the individual sensors, but more importantly, of the influence of a source...
-
Trajectories detection in a distributed multi-sensor tracking system
PublicationW pracy rozważono problem śledzenia obiektów poruszających się za pomocą rozproszonego systemu wieloczujnikowego. Głównym zadaniem systemu śledzenia jest detekcja i estymacja trajektorii obiektów poruszających się w obserwowanej przestrzeni. Trajektoria obiektu to ciąg estymat kinematycznego stanu obiektu, jego pozycji, prędkości, itp. Klasyczne systemy śledzenia oparte są na filtrze Kalmana korzystającym z danych z pojedynczego...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 140 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 160 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 180 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 200 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-0optic sensor - 250 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 210 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 300 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 270 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 190 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 260 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 290 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 170 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 280 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 150 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 230 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 240 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Data from pizoelectric pressure sensor placed inside PWK pump chamber
Open Research DataThe dataset contains raw data acquired from a piezoelectric pressure sensor placed inside PWK pump chamber. Pumping pressure was 10MPa, displacement was set to 100%, oil temperature was 33C. Columns "Czas" stand for a time in seconds and milliseconds, "Napięcie" stands for Voltage in Volts
-
C-reactive protein (CRP) evaluation in human urine using optical sensor supported by machine learning
PublicationThe rapid and sensitive indicator of inflammation in the human body is C-Reactive Protein (CRP). Determination of CRP level is important in medical diagnostics because, depending on that factor, it may indicate, e.g., the occurrence of inflammation of various origins, oncological, cardiovascular, bacterial or viral events. In this study, we describe an interferometric sensor able to detect the CRP level for distinguishing between...
-
Optical monitoring of electrochemical processes with ITO-based lossy-mode resonance optical fiber sensor applied as an electrode
PublicationIn this work we discuss the application of optical fiber sensors based on lossy-mode resonance (LMR) phenomenon for real-time optical monitoring of electrochemical processes. The sensors were obtained by a reactive high power impulse magnetron sputtering of indium tin oxide (ITO) on a 2.5 cm-long core of polymer-clad silica fibers. The LMR effect made monitoring of changes in optical properties of both ITO and its surrounding medium...
-
Expert system against machine learning approaches as a virtual sensor for ventricular arrhythmia risk level estimation
PublicationRecent advancements in machine learning have opened new avenues for preventing fatal ventricular arrhythmia by accurately measuring and analyzing QT intervals. This paper presents virtual sensor based on an expert system designed to prevent the risk of fatal ventricular arrhythmias associated with QT-prolonging treatments. The expert system categorizes patients into three risk levels based on their electrocardiogram-derived QT...
-
Study on Combined Optical and Electrochemical Analysis Using Indium-tin-oxide-coated Optical Fiber Sensor
PublicationThe growing needs for fast and reliable sensing devices stimulate development of new technological solutions. In this work a new multi-domain sensing method is demonstrated where optical sensing device has been applied to enhance amount of data received during electrochemical analysis. Thin, optically transparent, high-refractive-index, and electrically conductive indium tin oxide (ITO) film was deposited using magnetron sputtering...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.2
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.1
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...