Search results for: titanium%20alloys
-
The XRD diffraction patterns of (La0.3Sr0.6Ce0.1)0.9FexTi(1-x)O3-δ (x=0.1, 0.2 and 0.3) materials after reduction at 900 deg.C in hydrogen
Open Research DataThe (La0.3Sr0.6Ce0.1)0.9FexTi(1-x)O3-δ (x=0.1, 0.2 and 0.3) materials were synthesized via the Pechini method. First, the reagents in the form of nitrates were weighed and dissolved in DI water. In another beaker, a stoichiometric amount of titanium (IV) butoxide (Ti(OBu)4) was mixed together with reagent-grade ethylene glycol (EG), and citric acid...
-
The influence of polarization of titania nanotubes modified by a hybrid system made of a conducting polymer PEDOT and Prussian Blue redox network on the Raman spectroscopy response and photoelectrochemical properties
PublicationIn this work we show the impact of applied potential on network vibrations and photoelectrochemical properties of a composite material containing hydrogenated titania nanotubes and poly (3,4-ethylenedioxythiophene) with iron hexacyanoferrate (H-TiO2/pEDOT:Fehcf) acting as a redox centre. For this purpose, Raman spectroscopy measurements under the working electrode (WE) polarization were carried out, allowing investigation of changes...
-
Non-metaldoped TiO2 nanotube arrays for high efficiency photocatalytic decomposition of organic species in water
PublicationTitanium dioxide is a well-known photoactive semiconductor with a variety of possible applications. The procedure of pollutant degradation is mainly performed using TiO2 powder suspension. It can also be exploited an immobilized catalyst on a solid support. Morphology and chemical doping have a great influence on TiO2 activity under illumination. Here we compare photoactivity of titania nanotube arrays doped with non-metal atoms:...
-
SEM micrographs of Ti tooth implant corrosion
Open Research DataThe dataset contains micrographs made with a scanning electron microscope (SEM) Hitachi S-3400N of the tooth implant removed after inflammation. The inflammation was induced by the increased corrosion rate of the titanium screw. The reason for the corrosion to occur was the appearance of the concentration cell of different aeration for various areas...
-
Influence of Two-Stage Anodization on Properties of the Oxide Coatings on the Ti–13Nb–13Zr Alloy
PublicationThe increasing demand for titanium and its alloys used for implants results in need of such innovative surface treatment that may jointly increase corrosion resistance and biocompatibility, and demonstrate antibacterial protection at no cytotoxicity. The purpose of this research was to characterize the effect of two-stage anodization, performed for 30 min in phosphoric acid, at the presence of hydrofluoric acid in the second stage....
-
Measurements of the chemical composition of LTO:Cu powders
Open Research DataLithium titanate doped by copper was measured by X-ray photoemission spectroscopy (XPS). For sol-gel synthesis lithium acetate dehydrate and titanium (IV) butoxide 97% and copper (II) nitrate from Alfa Aesar were used as a reagents. Cu precursor was added in the proper weight to get an x index equal 0, 0.1 and 0.2. In the first step lithium acetate...
-
Absorbciâ vodoroda i povedenie vodoroda v slaâh titanovyh silavov s modificirovannoj poverhnost''û = Hydrogen absorption and hydrogen effects in the modified surface layers of Ti alloys
PublicationW pracy przedstawiono rezultaty badań absorpcji wodoru w stopach tytanu ze zmodyfikowaną za pomocą metod multipleksowych powierzchnią. W wyniku badań stwierdzono, iż po nadtapianiu laserowym w warunkach kriogenicznych, stopy tytanu wykazuja najwyższą zdolność absorpcji wodoru w wytworzonej warstwie wierzchniej.
-
Corrigendum to “Synthesis and photoelectrochemical behaviour of hydrogenated titania nanotubes modified with conducting polymer infiltrated by redox active network” [Electrochim. Acta 222 (20 December) (2016) 1281–1292]
Publication -
Sol-gel derived lithium titanate powders measured by XPS method
Open Research DataFor sol-gel synthesis lithium acetate dehydrate from Alfa Aesar GmbH &Co and titanium (IV) butoxide 97% from Aldrich were used as reagents. Copper (II) nitrate from Alfa Aesar was used as a source of Cu dopant. It was added in the proper weight to get an x index equal 0, 0.1 and 0.2. In the first step lithium acetate and copper nitrate were dissolved...
-
Maciej Jerzy Głowacki
PeopleMaciej Jerzy Głowacki is an alumnus of the Gdańsk University of Technology. He graduated with honors from the Faculty of Mechanical Engineering (B.Eng., 2017) and the Faculty of Electronics, Telecommunications and Informatics (M.S., 2018). Since 2014 he has been continuously actively involved in a research carried out at the Department of Metrology and Optoelectronics. His scientific activities include a deposition of antibacterial...
-
XPS study of the lithium titanate doped by copper
Open Research DataLithium titanate doped by copper was measured by X-ray photoemission spectroscopy. For sol-gel synthesis lithium acetate dehydrate from Alfa Aesar GmbH &Co and titanium (IV) butoxide 97% from Aldrich were used as reagents. Copper (II) nitrate from Alfa Aesar was used as a source of Cu dopant. It was added in the proper weight to get an x index equal...
-
XPS measurement of the Fe-Ti based materials
Open Research DataThe mono‐ and bimetal‐modified (Pd, Cu) titanium(IV) oxide and iron oxide (III) photocatalysts were prepared by chemical reduction method and characterized using XPS method. The composition of elements incorporated in the surface layer of mono- and bimetallic photocatalysts was determined by XPS analysis, as well as the valence state of elements. Measurements...
-
Te Zhong Zhu Zao Ji You Se He Jin/Journal of Special Casting & Nonferrous Alloys
Journals -
Reactions of Lithiated Diphosphanes R2P−P(SiMe3)Li (R = tBu and iPr) with [MeNacnacTiCl2·THF] and [MeNacnacTiCl3]. Formation and Structure of TitaniumIII and TitaniumIV β‑Diketiminato Complexes Bearing the Side-on Phosphanylphosphido and Phosphanylphosphinidene Functionalities
Publicationβ-Diketiminate complexes of TiIII-containing phosphanylphosphido ligands [MeNacnacTi(Cl){η2-P(SiMe3)- PR2}] (MeNacnac− = [Ar]NC(Me)CHC(Me)N[Ar]; Ar = 2,6- iPr2C6H3) were prepared by reactions of [MeNacnacTiCl2· THF] with lithium derivatives of diphosphanes R2P−P(SiMe3) Li (R = tBu, iPr) in toluene solutions. Surprisingly, reactions of [MeNacnacTiCl2·THF] with R2P−P(SiMe3)Li in THF solutions led to TiIV complexes containing phosphanylphosphinidene ligands...
-
Evaluation of the Cathodic Electrodeposition Effectiveness of the Hydroxyapatite Layer Used in Surface Modification of Ti6Al4V-Based Biomaterials
PublicationThe important issue associated with the design and the fabrication of the titanium and titanium alloy implants is the increase of their biointegration with bone tissue. In the presented paper, the research results concerning the conditions used in the cathodic deposition of hydroxyapatite on the surface Ti6Al4V substrates primarily modified by the production of TiO2 nanoporous coatings, TiO2 nanofibers, and titanate coatings, are...
-
Scalable Route toward Superior Photoresponse of UV-Laser-Treated TiO2 Nanotubes
PublicationTitanium dioxide nanotubes gain considerable attention as a photoactive material due to chemical stability, photocorrosion resistance, or lowcost manufacturing method. This work presents scalable pulsed laser modification of TiO2 nanotubes resulting in enhanced photoactivity in a system equipped with a motorized table, which allows for modifications of both precisely selected and any-large sample area. Images obtained from scanning...
-
Formation of Porous Structure of the Metallic Materials Used on Bone Implants
PublicationResearch on improvement of structure and fabrication methods of the bone implants are carried out for many years. Research are aimed to shape the structures, that will have a Young's modulus value similar to the value of the human bones Young's modulus. Depending on theporosity, Young's moduli can even be tailored to match the modulus of bone closer than solid metals can, thus reducing the problems associated with stress shielding...
-
Formation of High Corrosion Resistant Nanotubular Layers on TitaniumAlloy Ti13Nb13Zr
PublicationThis paper presents results of oxidation tests and corrosion investigations of titanium alloy Ti13Nb13Zr performed at different conditions. The oxide layers have been formed by electrochemical method in 2M H3PO4 + 0.3% HF solution for 30 min. and 1 h at 20 V constantvoltage. The corrosion tests have been made by potentiodynamic method in Ringer`s solution at pH ranged between 3 and 7. It has been shown that the nano-oxide films,...
-
Formation of High Corrosion Resistant Nanotubular Layers on TitaniumAlloy Ti13Nb13Zr
PublicationThis paper presents results of oxidation tests and corrosion investigations of titanium alloy Ti13Nb13Zr performed at different conditions. The oxide layers have been formed by electrochemical method in 2M H3PO4 + 0.3% HF solution for 30 min. and 1 h at 20 V constantvoltage. The corrosion tests have been made by potentiodynamic method in Ringer`s solution at pH ranged between 3 and 7. It has been shown that the nano-oxide films,...
-
Zgrzewanie tarciowe z mieszaniem wewnętrznym zgrzeiny stopów aluminium AW7075-T651 i AW6082-T6 = Friction stir welding of aluminium alloys AW-7075-t651 and AW-6082-t6
PublicationW pracy przedstawione są wyniki badań nad złączami doczołowymi zgrzewanymi przy użyciu technologii Friction Stir Welding (FSW), wykonanymi z wysokowytrzymałego stopu Al-Zn (AW-7075-T651) oraz stopu Al-Mg2Si (AW-6082-T6) o wysokiej odporności na korozję. Stop AW-7075-T651 okazał się bardziej podatny na obniżenie własności mechanicznych w odniesieniu do materiału rodzimego. Złącza ze stopu AW-6082-T6 wykazały się lepszą plastycznością....
-
Degradation of implantable materials – in vivo and in vitro research
PublicationThe article concerns the biological and electrochemical degradation of metallic implants in vivo and in vitro studies. The in vivo research dealt with degradation of plates used to join bones, as well as endoprostheses. The most common damages were: metalosis, breaking in the microstructure changes, breaking in area of holes, as well as plastic deformation throughout the length of an implant. The material used for the research...
-
TiO2-based magnetic nanocomposites with core-shell structure
PublicationThe main aim of the doctoral dissertation was preparation and characterization of photocatalysts, with particular emphasis on modified titanium (IV) oxide photocatalysts, which can be applied for the degradation of organic pollutants not susceptible to biodegradation. A particularly important aspect of the work was the development of preparation method of nanocomposites with the magnetic core-shell and photocatalyst shell (TiO2)...
-
Corrosion degradation of spacers – examination of changes in bone cement coating.
PublicationSpacer is a special implant used at the time of infection after endoprosthetic surgery. It consists of a metal core and bone cement coating with an antibiotic. In the human body spacers are exposed to degradation processes. This paper looks at the effect of corrosion on spacers. Electrochemical corrosion tests were performer on titanium pins with bone cement coating in two solutions: Ringer’s solution and artificial...
-
Biocompatibility and bioactivity of bearing loaded metallic implants
PublicationPresentation of developed titanium alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behavior for bearing loaded implants, e.g. hip joint and knee joint endoproshtesis.
-
Preparation and structure of nanocrystalline sol-gel derived Cu doped LiTi2O4 powders
PublicationAmong the spinel oxides materials, lithium titanate (Li1+xTi2-xO4 where 0 ≤ x ≤ 0.33) could be very interested from pratical applications point of view. Lithium titanate is a II type spinel oxide superconductor with relatively high (~13 K for x = 0) superconducting transition temperature Tc. Above Tc lithium titanate shows metallic behaviour and can be used e.g. as electrodes for rechargeable lithium-ion batteries. Since the discovery...
-
Effects of CO2 and Nd:YAG Laser Remelting of the Ti6Al4V Alloy on the Surface Quality and Residual Stresses
PublicationThe titanium alloys are materials susceptible to tribological wear and the laser treatment can be applied in surface treatment processes to obtain for example higher hardness level. From the other side, it is important to take into consideration, that hardness increase that can be connected with cracks . The aim of this research was to investigate the effects of different lasers and the process parameters on the form and level...
-
AN OVERVIEW OF HEAT TRANSFER ENHANCEMENT BASED UPON NANOPARTICLES INFLUENCED BY INDUCED MAGNETIC FIELD WITH SLIP CONDITION VIA FINITE ELEMENT STRATEGY
PublicationThe mathematical model of heat generation and dissipation during thermal energy transmission employing nanoparticles in a Newtonian medium is investigated. Dimensionless boundary layer equations with correlations for titanium dioxide, copper oxide, and aluminium oxide are solved by the finite element method. Parameters are varied to analyze their impact on the flow fields. Various numerical experiments are performed consecutively...
-
Organic pollutants photodegradation increment with use of TiO2 nanotubes decorated with transition metals after pulsed laser treatment
PublicationAmong various titanium(IV) oxide (TiO2, titania) structures, 1D nanotubes (TiO2 NTs) produced during the two-electrode anodization process, are extensively utilized in sensors or supercapacitors as well as in photo(electro)catalytic water splitting. However, due to wide bandgap and fast electron-hole recombination additional modifications, mostly concerned on materials surface, are required. According to the recent research, TiO2...
-
Bioactive core material for porous load-bearing implants
PublicationSo far state of knowledge on biodegradable materials is reviewed. Among a variety of investigated materials, those composed of polymers and ceramics may be considered as only candidates for a core material in porous titanium alloy. The collagen and chitosan among natural polymers, polyhydroxy acids among synthetic polymers, and hydroxyapatite and tricalcium phosphate among ceramics are proposed for further research. Three essential...
-
Optical and chemical characterization of thin TiNx films deposited by DC-magnetron sputtering
PublicationThin titanium nitride (tinx) films were deposited on silicon substrates by means of a reactive dc-magnetron plasma. Layers were synthesized under various conditions of discharge power and nitrogen flows in two operation modes of the magnetron (the so-called "balanced" and "unbalanced" modes). The optical constants of the tinx films were investigated by spectroscopic ellipsometry (se). X-ray photoelectron spectroscopy (xps) was...
-
ARGENTUM Injectable nanocomposite for an instantaneous fixation of titanium implants in a bone with effective antibacterial properties
ProjectsProject realized in Zakład Technologii Biomateriałów according to DEC-38/2020/IDUB/I.3.3 agreement from 2020-11-17
-
Optimalization of TiO2 nanotube geometry using fuzzy reasoning approach
PublicationThe geometry of TiO2 nanotube layer on titanium, obtained by electrochemical anodization, has been determined by using fuzzy reasoning approach. A proposed method showed the possibility of nanotube array architecture optimization by choosing an appropriate anodization condition. A fuzzy logic controller (FLC) was utilized using Matlab Software.
-
Fabrication and characterization of composite TiO2 nanotubes/ boron-doped diamond electrodes towards enhanced supercapacitors
PublicationThe composite TiO2 nanotubes / boron-doped diamond electrodes were deposited using Microwave Plasma Enhanced Chemical Vapor Deposition resulting in the improved electrochemical performance. This composite electrode can deliver high specific capacitance of 7.46 mF cm‐− 2 comparing to boron-doped diamond (BDD) deposited onto flat Ti plate (0.11 mF cm‐− 2).The morphology and composition of composite electrode were characterized...
-
Cathodically activated Au/TiO2 nanocomposite synthesized by a new facile solvothermal method: An efficient electrocatalyst with Pt-like activity for hydrogen generation
PublicationWe report here a facile, template-free and one-step solvothermal approach for the synthesis of high-temperature stable gold/titania nanocomposite (NCs), providing a new, simple, quick and inexpensive wet-chemical route. Our approach is based on the assembly of gold salt and titanium butoxide in dimethyl sulfoxide (DMSO). Also, we present here, for the first time, a cathodically activated Au/TiO2 catalyst with Pt/C activity for...
-
Imaging of the effects of pitting corrosion with the use of AFM
Open Research DataPitting corrosion is a local attack on a metal surface, limited to a point or small area, which appears as a hole. Pitting corrosion is one of the most harmful forms of corrosion due to the fact that it is associated with small, difficult to detect damage, that can even lead to perforation of the structure. A single pit may range in size from micrometers...
-
Defective TiO2 Core-Shell Magnetic Photocatalyst Modified with Plasmonic Nanoparticles for Visible Light-Induced Photocatalytic Activity
PublicationIn the presented work, for the first time, the metal-modified defective titanium(IV) oxide nanoparticles with well-defined titanium vacancies, was successfully obtained. Introducing platinum and copper nanoparticles (NPs) as surface modifiers of defective d-TiO2 significantly increased the photocatalytic activity in both UV-Vis and Vis light ranges. Moreover, metal NPs deposition on the magnetic core allowed for the effective separation...
-
High-temperature Corrosion of ~ 30 Pct Porous FeCr Stainless Steels in Air: Long-Term Evaluation Up to Breakaway
PublicationIn this work, a long-term (up to 6000 hours) corrosion evaluation of three porous (~ 30 pct of initial porosity) ferritic iron-chromium alloys with different Cr contents (20, 22, and 27 wt pct of Cr) was carried out at 600 C, 700 C, 800 C, and 900 C in air. Mass gain measurements and SEM analyses revealed that at temperatures above 600 C, all alloys exhibit breakaway corrosion, whereas at 600 C, none of the alloys were heavily...
-
Reinforced aluminium reference measurement R63 – earlier tests
Open Research DataPreliminary testing of aluminium alloys against 100Cr6 steel ball. Preparation to tests on wear of Al6061 alloy in ball on disk experiment. Research on the reinforcing effect of aluminium alloy injection reinforcement with TiN and WC powders in laser remelted surface layer.
-
Reinforced aluminium reference measurement Result1 – earlier tests
Open Research DataPreliminary testing of aluminium alloys against 100Cr6 steel ball. Preparation to tests on wear of Al6061 alloy in ball on disk experiment. Research on the reinforcing effect of aluminium alloy injection reinforcement with TiN and WC powders in laser remelted surface layer.
-
Jacek Ryl dr hab. inż.
PeopleI have obtained my PhD in chemical technology in 2010. In the same year, I was employed at the Department of Electrochemistry, Corrosion and Materials Engineering at the Faculty of Chemistry. In 2018 I received habilitation at the Faculty of Chemistry GUT in technical sciences in the discipline of chemical technology. From 2021, he was employed at the Institute of Nanotechnology and Materials Science at the Faculty of Technical...
-
Reactive deposition of TiNx layers in a DC-magnetron discharge
PublicationTiNx layers have been deposited in 'balanced mode' and 'unbalanced mode' of a reactive DC-magnetron plasma (carrier gas argon, reactive gas nitrogen) under different conditions. Discharge power and reactive gas flow have been varied. The layers have been examined by X-ray photoelectron spectroscopy (XPS), X-ray reflectometry (XR), and spectroscopic ellipsometry (SE). The results of the layer analyses were combined with plasma investigations...
-
XPS-TiO2 heated in H2
Open Research DataThese XPS spectra were recorded for TiO2 heat-treated at 450-600oC in H2. Surface oxygen groups were determined. Deconvolution of Ti 2p peak allowed to determine Ti3+ on the titania surface.
-
Mono- and bi-metallic plasmonic photocatalysts for degradation of organic compounds under UV and visible light irradiation
PublicationTitania powders were surface modified with gold and/or silver nanoparticles (NPs) by photodeposition method. Gold modified titania exhibited much higher photocatalytic activity during methanol dehydrogenation under UV irradiation than titania modified with monometallic silver and bimetallic Au–Ag NPs. Bimetallic photocatalysts exhibited either enhanced or reduced visible light activity, depending on properties of noble metal NPs,...
-
FTIR-TiO2 heated at 400-600oC in Ar or H2
Open Research DataData contain FTIR diffuse eflectance spectra of TiO2, which was heat-treated at 400-600oC in Ar or H2. Hydrogen reduced TiO2 revealed new bands due to the adsorption of some species on the titania oxygen vacancy sites.
-
Microscopic examination of CuNiFeR pipeline
Open Research DataCopper and nickel alloys called cunifers (Cu, Ni, Fe and R – rest of alloy elements) have found wide application in the production of ship pipeline components in contact with sea water, such as, for example, the main engine cooling system. These alloys are characterized by a very high corrosion resistance, which is ensured by appropriately carried out...
-
Macroscopic examination of CuNiFeR pipeline
Open Research DataCopper and nickel alloys called cunifers (Cu, Ni, Fe and R – rest of alloy elements) have found wide application in the production of ship pipeline components in contact with sea water, such as, for example, the main engine cooling system. These alloys are characterized by a very high corrosion resistance, which is ensured by appropriately carried out...
-
Hydrogenation process ofTiO2/BiVO4/PEDOT:PSS observed by XPS method
Open Research DataTitania nanotubes synthesis was based on a two-stage anodization process at water/ethylene glycol (5%/95%) electrolyte containing 0.27 M NH4F and 1 M H3PO4 described previously. Anodization process was performed in two-electrode cell compartment using platinum mesh as a cathode. The distance between electrodes was about 2 cm. The anodization voltage...
-
XPS analysis of strontium titanate ceramics
Open Research DataThe chemical composition of the strontium titanite doped with yttrium and iron ceramic samples was investigated. Samples of Y0.07Sr0.93Ti0.8Fe0.2 were prepared by solid phase reaction and sintered for 24 and 48 hours. Chemical composition was measured by UHV OmicronNanotechnology XPS system. The analysis confirmed the chemical composition of the ceramics...
-
Laser-assisted approach for improved performance of Au-Ti based glucose sensing electrodes
PublicationThis paper focuses on the synthesis route and electrochemical properties of electrocatalytic material based on gold nanoparticles (NPs) embedded in a structured titanium template obtained via optimized anodization, chemical etching and laser processing. SEM inspection reveals the presence of Au NPs (60–90 nm in diameter) sited in the titanium foil cavities. Performed electrochemical measurements enable nomination of the set of working...
-
Tensile test of part of CuNiFeR pipeline
Open Research DataCopper and nickel alloys called cunifers (Cu, Ni, Fe and R – rest of alloy elements) have found wide application in the production of ship pipeline components in contact with sea water, such as, for example, the main engine cooling system. These alloys are characterized by a very high corrosion resistance, which is ensured by appropriately carried out...