Search results for: CT
-
SEMINARS IN ULTRASOUND CT AND MRI
Journals -
Multislice CT in functional cardiac exploration.
PublicationArtykuł przedstawia analizę oraz omówienie wykonanych badań w zastosowaniu tomografia wielorzędowej w diagnostyce czynnościowej serca. Pokazano zarówno aspekty technicznej metody jak i możliwości zastosowań medycznych.
-
Laser microbeam CT scanning of dosimetry gels
Publication -
Metrology CT technology and its applications in the precision engineering industry
Publication -
Preclinical [18F]tetrafluoroborate-PET/CT imaging of pituitary gland hyperplasia
Publication -
Initial evaluation of commercial optical CT‐based 3D gel dosimeter
Publication -
Determining optimal gel sensitivity in optical CT scanning of gel dosimeters
Publication -
CT&F-Ciencia Tecnologia y Futuro
Journals -
DEM modelling of concrete fracture based on its structure micro-CT images
PublicationW rozdziale książki zawarto numeryczne wyniki mezoskopowe dotyczące postępującego pękania betonu na poziomie kruszywa. Do badania procesu pękania belki betonowej z karbem w trzech (3D) i dwóch (2D) wymiarach zastosowano metodę elementów dyskretnych (DEM). Niejednorodność betonu uwzględniono stosując czterofazowy opis: kruszywo, zaprawa, makropustki i międzyfazowe strefy przejściowe. W obliczeniach DEM na podstawie zdjęć rentgenowskich...
-
Visualizing Carotid Bodies With Doppler Ultrasound Versus CT Angiography: Preliminary Study
PublicationOBJECTIVE. The purpose of this article is to evaluate the utility of ultrasound in identifying carotid bodies (CBs) in patients with drug-resistant arterial hypertension. SUBJECTS AND METHODS. We enrolled 13 patients with drug-resistant hypertension into a trial for surgical CB excision. CT angiography (CTA) and Doppler ultrasound (DUS) of the cervical arteries were performed before surgery. CBs were identified in a blind manner...
-
Adjusted subpixel method enables optimisation of bronchial measurements in high-resolution CT
PublicationArtykuł przedstawia metodę korekcji pomiaru rozmiaru oskrzeli w techice HRCT. W celu walidacji metody zastosowano fantom. W efekcie opracowano metodę nieliniowej predykcji rzeczywistych rozmiarów ścianek małych oskrzeli w obrazach HRCT.
-
SU‐GG‐T‐290: A Fast Optical CT Scanner for Gel Dosimetry
Publication -
Szacowanie niepewności funkcji przetwarzania przetwornika LEM CT -5T metodą Monte Carlo
PublicationW referacie zaprezentowano metodologię szacowania niepewności funkcji przetwarzania przetwornika prądowego, na przykładzie przetwornika LEM CT-5T, przy zastosowaniu metody opartej na Przewodniku GUM z zastosowaniem prawa propagacji niepewności oraz metody numerycznej Monte Carlo. Przedstawiono szczegółową analizę doboru rozkładu wielkości wejściowej. W przypadku metody Monte Carlo dobór rozkładu wielkości wejściowych jest bardzo...
-
Szacowanie niepewności funkcji przetwarzania przetwornika LEM CT -5T metodą Monte Carlo
PublicationW referacie zaprezentowano metodologię szacowania niepewności funkcji przetwarzania przetwornika prądowego, na przykładzie przetwornika LEM CT-5T, przy zastosowaniu metody opartej na Przewodniku GUM, z zastosowaniem prawa propagacji niepewności oraz metody numerycznej Monte Carlo. Przedstawiono szczegółową analizę doboru rozkładu wielkości wejściowej. W przypadku metody Monte Carlo dobór rozkładu wielkości wejściowych jest bardzo...
-
Experimental investigations of damage evolution in concrete during bending by continuous micro-CT scanning
PublicationThe paper describes experimental investigation results of fracture in notched concrete beams under quasi-static three-point bending. To visualize 3D fracture in concrete under bending, an extended X-ray micro-computed tomography system was used, i.e. the tomography system SkyScan 1173 was connected to the loading machine ISTRON 5569. This combined system enabled to shot images of deforming concrete beams during a continuous deformation...
-
Experimental investigations on water sorptivity in mortars with the use of X-ray micro-CT system.
PublicationW pracy doswiadczalnej zbadano zjawisko sorpcji wody w pryzmatycznych próbkach zapraw, które jest ściśle powiązane z trwałością materiału. Sorpcyjność oceniana na etapie ustalonym w połączeniu z warunkami zewnętrznymi może być wykorzystana do przewidywania okresu użytkowania. Sorpcyjność początkową i wtórną wody w próbkach zapraw nienasyconych zmierzono w badaniach laboratoryjnych zgodnie z normą amerykańską ASTM C 1585–04. Wpływ...
-
Sensitivity calibration procedures in optical‐CT scanning of BANG®3 polymer gel dosimeters
Publication -
SU‐GG‐T‐357: Initial Evaluation of a Fast Optical CT Scanner for Gel Dosimetry
Publication -
Performance of a commercial optical CT scanner and polymer gel dosimeters for 3‐D dose verification
Publication -
Nasal endoscopy: an adjunct to patient selection for preoperative low-dose CT examination in chronic rhinosinusitis
Publication -
Fracture evolution in concrete compressive fatigue experiments based on X-ray micro-CT images
PublicationArtykuł omawia ewolucje pękania w betonie podczas cyklicznego ściskania betonu. Przestrzenną ewolucję pękania zobrazowano stosując mikro-tomograf rentgenowski. Zdjęcia wykonano dla różnych cykli zmęczeniowych. Wyniki porównano z testami monotonicznymi. Jakościowa ewolucja objętości pękania ze wzrostem zmęczeniowego zniszczenia pokazała silnie nieliniowy kształt.
-
KOMPLEKSOWY PROJEKT ZAMOCOWANIA RUROCIĄGÓW 4” WT 0,3” CT X70 NA ZMODERNIZOWANEJ PLATFORMIE PETROBALTIC
PublicationW ramach realizowanej pracy przeprowadzono analizę kilku koncepcji zawieszenia rurociągów na platformie wydobywczej Lotos Petrobaltic. Wykonano obliczenia sprawdzające oraz opracowano kompleksowy projekt technicznych obejmujący dokumentację warsztatową oraz instrukcję montażu i eksploatacji. Zastosowane unikatowe rozwiązanie uchwytów rur CT.
-
KOMPLEKSOWY PROJEKT ZAMOCOWANIA RUROCIĄGÓW 4” WT 0,3” CT X70 NA ZMODERNIZOWANEJ PLATFORMIE PETROBALTIC
PublicationCelem pracy było wykonanie analizy obciążeń oddziałujących na rurociągi zatłaczające wodę do złoża oraz kompleksowego projektu fundamentowania rur CT i riserów eksportowych ropy wraz z pomostami obsługowymi na zmodernizowanej platformie PETROBALTIC. W tym celu wykonano obliczenia MES struktury platformy oraz opracowano dokumentację wykonawczą.
-
Characteristics of a new polymer gel for high-dose gradient dosimetry using a micro optical CT scanner
Publication -
Primary mediastinal B-cell lymphoma – metabolic and anatomical features in 18FDG-PET/CT and response to therapy
Publication -
Investigations on fracture in reinforced concrete beams in 3-point bending using continuous micro-CT scanning
PublicationThis study explores a fracture process in rectangular reinforced concrete (RC) beams subjected to quasi-static three-point bending. RC beams were short and long with included longitudinal reinforcement in the form of a steel or basalt bar. The ratio of the shear span to the effective depth was 1.5 and 0.75. The focus was on the load–deflection diagram and crack formation. Three-dimensional (3D) analyses of the size and distribution...
-
Methodology of generation of CFD meshes and 4D shape reconstruction of coronary arteries from patient-specific dynamic CT
PublicationDue to the difficulties in retrieving both the time‑dependent shapes of the vessels and the generation of numerical meshes for such cases, most of the simulations of blood flow in the cardiac arteries use static geometry. The article describes a methodology for generating a sequence of time‑dependent 3D shapes based on images of different resolutions and qualities acquired from ECG‑gated coronary artery CT angiography. The precision...
-
3D X-ray Micro-CT Analysis of Rebar Corrosion in Reinforced Concrete Subjected to a Chloride-Induced Environment
PublicationThe paper presents experimental investigations of the concrete cover protective ability to coun-teract rebar corrosion in reinforced concrete cubes. To study and quantify the consequences of corrosion a reinforced concrete sample was subjected to chloride-induced environment in order to get corroded and combined with un-corroded sample. Chloride-accelerated technique can in-duce a high degree of corrosion within at a controlled...
-
Microemulsion-Mediated Synthesis and Properties of Uniform Ln:CaWO4(Ln = Eu, Dy) Nanophosphors with Multicolor Luminescence for Optical and CT Imaging
Publication -
KOMPLEKSOWY PROJEKT ZAMOCOWANIA FUNDAMENTU RISERA EKSPORTU ROPY ORAZ FUNDAMENTÓW RUR CT NA PLATFORMIE LOTOS PETROBALTIC
PublicationCelem pracy było wykonanie dokumentacji projektowo‐wykonawczej i obliczeń konstrukcji stalowych fundamentowania rurociągów wiszących zatłaczania oraz eksportu ropy montowanych na pontonie platformy „Lotos Petrobaltic”.
-
Modelling of concrete facture at aggregate level using DEM based on x-ray mu CT images of internal structure
PublicationW artykule pokazano wyniki dyskretne DEM dla pękania betonu poddanego zginaniu. Beton został symulowany jako ośrodek 4-fazowy. Mikrostrukturę betonu określono na podstawie zdjęć uzyskanych mikro-tomografem. Szczególną uwagę zwrócono na zjawiska mikrostrukturalne podczas zarysowania na poziomie kruszywa.
-
A three-dimensional meso-scale approach to concrete fracture based on combined DEM with x-ray micro-CT images
PublicationArtykuł omawia wyniki numeryczne uzyskane stosując 3-wymiarowy mezoskopowy model do opisu pękania w betonie na poziomie kruszywa w belce z nacięciem podczas zginania. Do obliczeń użyto metodę elementów dyskretnych. Beton został opisany jako materiał 4-fazowy złożony z kruszywa, zaprawy, makro-porów i stref przejściowych miedzy kruszywem a zaprawą. Kształt i położenia kruszywa przyjęto na podstawie skanów z mikro-tomografu. Uzyskano...
-
MODELLING OF CONCRETE FRACTURE AT AGGREGATE LEVEL USING DEM BASED ON X-RAY mu CT IMAGES OF INTERNAL STRUCTURE
PublicationThe paper describes two-dimensional meso-scale numerical results of fracture in notched concrete beams under quasi-static three-point bending. Concrete was modelled as a random heterogeneous 4-phase material composed of aggregate particles, cement matrix, interfacial transitional zones (ITZs) and air voids. As a numerical approach, the discrete element method (DEM) was used. The concrete micro-structure in calculations was directly...
-
Validation of high-resolution 3D patient QA for proton PBS and IMPT using laser CT of improved polymer gel dosimeters
Publication -
SU‐FF‐T‐209: New Polymer Gel Dosimeter with High Refractive Index for Artifact‐Free Optical CT Scanning
Publication -
Investigation of sinonasal anatomy via low-dose multidetector CT examination in chronic rhinosinusitis patients with higher risk for perioperative complications
Publication -
Dosimetry study of Re-188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser-beam optical CT scanner
Publication -
Application of EARL (ResEARch 4 Life®) protocols for [18F]FDG-PET/CT clinical and research studies. A roadmap towards exact recovery coefficient
Publication -
SU-FF-T-192: Complete 3D QA for Rapid Arc Using BANG Polymer Gel and OCTOPUS-IQ Fast Laser CT Scanner
Publication -
Room temperature synthesis of water-dispersible Ln 3+ :CeF 3 (Ln = Nd, Tb) nanoparticles with different morphology as bimodal probes for fluorescence and CT imaging
Publication -
Comparing radioactive tracers 18F-FDG and 18F-FLT in the staging of diffuse large B-cell lymphoma by PET/CT examination: A single-center prospective study
Publication -
SU‐GG‐T‐208: 3‐D Dosimetric Comparison of IMRT with 2.5 Mm HD120 MLC Using Optical CT Based Polymer Gel and PRESAGE Dosimeters
Publication -
US not bright but right method of thyroid volume estimation even in large and substernal extended goitres. Comparison of US and three methods of CT thyroid evaluation - prospective study.ON LINE
PublicationBackground Ultrasound is nowadays a method of choice for thyroid volume assessment. However, its disadvantage is some inaccuracy, which is said to be higher in huge, especially substernally extended goitres. Aims The aim of the study was to compare the US and CT thyroid volumetric measurements: multi-observers (CT MO) and one-observer (CT OO) to CT planimetry results (CT Pl) in patients with large goitres. Materials & Methods The...
-
Modelowanie wybranych własności mechanicznych struktur po-rowatych przeznaczonych na trzony długoterminowych implan-tów ortopedycznych, otrzymywanych z wykorzystaniem metod micro-CT oraz SLM
PublicationArtykuł przedstawia metodologię opracowania geometrii materiału porowatego opartego na bazie stopu tytanu. W metodologii tej dąży się do uzyskania struktury porowatej jak najbardziej zbliżonej do struktury zdrowej tkanki kostnej, bazującej na rzeczywistych modelach geometrycznych uzyskanych ze zdjęć rentgenowskich z tomografii komputerowej. Rzeczywisty materiał po odpowiedniej obróbce modelu geometrycznego oraz przy zachowaniu...
-
Efficacy, pharmacokinetics, and safety of the biosimilar CT-P10 compared with rituximab in patients with previously untreated advanced-stage follicular lymphoma: a randomised, double-blind, parallel-group, non-inferiority phase 3 trial
Publication -
Webinaria CTWiT (wspólne)
e-Learning CoursesZasób zawierający wspólne Webinaria CTWiT
-
REALIZACJA INTERFEJSU CTI W SOFTSWITCHACH
PublicationW artykule przedstawiono problem zastosowania i realizacji interfejsów CTI w architekturze softswitcha. Dokonano analizy, pod kątem funkcjonalności, dwóch standardów CTI: CSTA oraz Parlay/OSA. Następnie wykonano model softswitcha z interfejsem CTI w standardzie CSTA w oparciu o projekt FreeSWITCH, na którym to modelu przeprowadzono testy i badania.
-
CTBUH Journal
Journals -
The propagation of the waves in the CTO S.A. towing tank
PublicationThe paper presents the results of research focused on the wave propagation in the CTO S.A. deepwater towing tank. In the scope of paper, the wavemaker transfer function was determined for regular waves, based on the Biésel Transfer Function and further for irregular waves, based on Hasselman model of nonlinear energy transfer. The phenomena: wave damping, wave breakdown and wave reflection, were measured, analyzed and mathematically...
-
Importance of model tests in design and operation of watercraft for example CTO
PublicationShip Hydromechanics Division is a specialized research and development department of Ship Design and Research Centre conducting tests and research in the field of hydromechanics, connected with design and operation of ships and other floating structures, in scope of: predictions, numerical analyses, designs of - hull shape optimized with respect to the ship’s functions with the application of modern design tools, screw propellers...
-
The Conjugated Triangle Method CTM of the detection of inconsistent bids in the construction industry
Publication -
Shaping the SPL Spectra of the Acoustic Noise Emitted by Inverter-Fed Indu- ction Motors
PublicationW artykule przedstawiono nowe podejście do zmniejszania wpływu właściwości mechanicznych maszyny na emitowany przez nią hałas akustyczny. Dokonano identyfikacji mechanicznych rezonansów maszyny wykorzystując modulację RPWM z losowym wyborem częstotliwości nośnej oraz modulację sigma delta, dla której otrzymano relatywnie płaskie widmo prądu. Skonstruowano na tej podstawie funkcję gęstości prawdopodobieństwa wyboru częstotliwości...
-
Mesenchymal Phenotype of CTC-Enriched Blood Fraction and Lymph Node Metastasis Formation Potential
Publication -
Chemometric Method of Spectra Analysis Leading to Isolation of Lysozyme and CtDNA Spectra Affected by Osmolytes
PublicationW niniejszej pracy zaprezentowana została chemometryczna metoda analizy danych widmowych, prowadząca do wyizolowania widm FTIR biomakrocząsteczek (lizozymu z białka jaja kurzego i ctDNA) zaburzonych przez wybrane osmolity (TMAO, betainę) w roztworach wodnych. Została ona oparta na metodzie widm różnicowych, wykorzystywanej pierwotnie do określania struktury rozpuszczalnika wokół cząsteczek substancji rozpuszczonej. Cykliczne wykorzystanie...
-
Mapping Mechanostable Pulling Geometries of a Therapeutic Anticalin/CTLA-4 Protein Complex
Publication -
CTS-Clinical and Translational Science
Journals -
Trust Dynamics Analysis of CTR Scheme Subversion under Virtual Anonymity and Trust-Unaware Partner Selection
PublicationWe propose a framework to study Markovian trust value dynamics in a centralized Computational Trust and Reputation (CTR) scheme under trust-unaware partner selection using a mean-value approximation. Analytically founded answers are sought to questions like: Can dishonest agents subvert the CTR scheme (i.e., acquire higher trust values than honest agents)? Is indirect reciprocity incentivized? Is there a qualitative impact of a...
-
Designate of CTOD for WM and HAZ, report no: WOiO/II/122/2014
PublicationTypical (normative) testing of materials and/or welded joints do not answer on all questions about material or welded joint properties. In ship building and off-shore sectors, many strucures requires materials and joint with higher than typical fatigue resistance. Imact tests, which are carried out during welding technology qualification, gives answer about ductility, CTOD tests results about material or welded joint ability to...
-
Interaction of HLA-DRB1 Alleles with CTLA-4 in the Predisposition to Graves' Disease: The Impact of DRB1*07
Publication -
Designate CTOD of Weld Metal of butt weld, No WOiO/II/108/2013
PublicationTypical (normative) testing of materials and/or welded joints do not answer on all questions about material or welded joint properties. In ship building and off-shore sectors, many strucures requires materials and joint with higher than typical fatigue resistance. Imact tests, which are carried out during welding technology qualification, gives answer about ductility, CTOD tests results about material or welded joint ability...
-
THE EFFECT OF NOTCH DEPTH ON CTOD VALUES IN FRACTURE TESTS OF STRUCTURAL STEEL ELEMENTS
PublicationIn elements of steel structures working at low temperatures, there is a risk of appearance of brittle fracture. This risk is reduced through the use of certified materials having guaranteed strength at a given temperature. A method which is most frequently used to determine brittle fracture toughness is the Charpy impact test, preformed for a given temperature. For offshore structures intended to work in the arctic climat e, the...
-
CTD Gdańsk Deep_2001_2005
Open Research DataDataset includes measurements of conductivity (mS cm-1), temperature (°C), sound speed (m s-1) and salinity (PSU) made with the probe Falmouth Scientific Inc. The research was carried out in 2001 (at the turn of May and June), 2003 (beginning of May), 2005 (end of April) and in 2002 and 2004 (at the turn of September and October). In 2002, only temperature...
-
CTAD-Cumhuriyet Tarihi Arastirmalari Dergisi
Journals -
Stromal-Epithelial Cross-Talk in the Intestinal Stem Cell Niche is Mediated by a Regulatory Network that Involves TGF-Beta and CTGF
Publication -
Designate CTOD Heat Affected Zone of butt weld, Report No: WOiO/II/76/2013
PublicationTypical (normative) testing of materials and/or welded joints do not answer on all questions about material or welded joint properties. In ship building and off-shore sectors, many strucures requires materials and joint with higher than typical fatigue resistance. Imact tests, which are carried out during welding technology qualification, gives answer about ductility, CTOD tests results about material or welded joint ability...
-
EXPERIMENTAL AND NUMERICAL INVESTIGATION ON SPECIMEN GEOMETRY EFFECT ON THE CTOD VALUE FOR VL-E36 SHIPBUILDING STEEL
PublicationThere are special cases in the marine industry, where additional material tests, such as the fracture toughness test, must be performed. Additional fracture toughness tests, such as CTOD (Crack Tip Opening Displacement), are typically performed on three-point bend specimens. The dimension that defines all the specimen dimensions is the thickness of the material to be tested. It is recommended by classification societies (e.g. DNVGL)...
-
<b><i>CTLA4</i></b> and <b><i>CD28</i></b> Gene Polymorphisms with Respect to Affective Symptom Domain in Schizophrenia
Publication -
Fabrication of wormhole-like YSZ and Ni-YSZ by the novel soft-hard template CTAB/NaCl-assisted route. Suppressing Ni coalescence in SOFC
PublicationA novel one-pot synthesis route leading to the formation of a wormhole-like structure was developed for the successful fabrication of porous YSZ and Ni-YSZ systems. This method involved co-precipitation in the presence of the micelle-forming agents CTAB/Pluronic P123 and crystallising NaCl. The obtained skeletons were mechanically stable and presented almost 50% uniform, open porosity without using any additional pore-formers....
-
Assessment of Clinical Usefulness of Resting Electrocardiogram (PH-ECG Score) in Monitoring the Efficacy of Balloon Pulmonary Angioplasty (BPA) in Patients with Chronic Thromboembolic Pulmonary Hypertension (CTEPH)
Publication -
CTOD designation for WM and HAZ in butt joint made from S460 ML steel, Expertise No. WOiO/II/82/2015
PublicationTypical (normative) testing of materials and/or welded joints do not answer on all questions about material or welded joint properties. In ship building and off-shore sectors, many strucures requires materials and joint with higher than typical fatigue resistance. Imact tests, which are carried out during welding technology qualification, gives answer about ductility, CTOD tests results about material or welded joint ability to...
-
Dni Otwarte CTT
EventsCTT zaprasza na konsultacje pracowników naukowych i doktorantów, którzy są zainteresowani pozyskaniem projektów badawczych lub już realizują projekty o potencjale komercjalizacyjnym.
-
Wpływ parametrów geometrycznych próbki stalowej na uzyskaną wartość wskaźnika krytycznego rozwarcia wierzchołka szczeliny CTOD w badaniach odporności na pękanie
PublicationW pracy podjęto problem określania ciągliwości materiału metodami mechaniki pękania, jako jednego z częściej wymaganych kryteriów dla konstrukcji okrętowych i oceanotechnicznych. Na podstawie rozważań i modeli numerycznych, studiowano problem wpływu parametrów geometrycznych próbki na wynik znormalizowanej próby określania krytycznego rozwarcia wierzchołka szczeliny - CTOD. W pierwszej części pracy dokonano przeglądu metod...
-
Differential Response of MDA-MB-231 and MCF-7 Breast Cancer Cells to In Vitro Inhibition with CTLA-4 and PD-1 through Cancer-Immune Cells Modified Interactions
Publication -
Dni Otwarte CTT PG
EventsPracownicy CTT zapraszają na konsultacje osoby, które zamierzają pozyskać projekty badawcze oraz tych, którzy już realizują projekty o potencjale komercjalizacyjnym.
-
Dni Otwarte CTT PG
EventsPracownicy CTT zapraszają na konsultacje osoby, które zamierzają pozyskać projekty badawcze oraz tych, którzy już realizują projekty o potencjale komercjalizacyjnym.
-
Plasmon and structure resonances in the scattering of light by a periodic chain of silver nanocylinders
Publication -
Grating Resonances on Periodic Arrays of Sub-wavelength Wires and Strips: From Discoveries to Photonic Device Applications
Publication -
New aspects of the use of Optical Theorem in the analysis of microcavity lasers
Publication -
Low-threshold lasing eigenmodes of an infinite periodic chain of quantum wires
Publication -
Optical theorem helps understand thresholds of lasing in open semiconductor microcavities
Publication -
Funkcjonowanie CTT w Stanach Zjednoczonych – webinarium
EventsCentrum Transferu Wiedzy i Technologii PG zaprasza do udziału w webinarium. Naszymi gośćmi będą przedstawicielki centrów transferu technologii z prestiżowych amerykańskich uniwersytetów.
-
Grating resonances on periodic arrays of sub-wavelength wires and strips: Historical narrative and possible applications
Publication -
Optical Theorem Helps Understand Thresholds of Lasing in Microcavities With Active Regions
Publication -
EH36 steel for shipbuilding - fracture documentation for CTOD test (plate thicnkness 60mm), a0/W = 0.6
Open Research DataThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
EH36 steel for shipbuilding - fracture documentation for CTOD test (plate thicnkness 40mm), a0/W = 0.5
Open Research DataThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
EH36 steel for shipbuilding - fracture documentation for CTOD test (plate thicnkness 30mm), a0/W = 0.6
Open Research DataThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
EH36 steel for shipbuilding - fracture documentation for CTOD test (plate thicnkness 30mm), a0/W = 0.5
Open Research DataThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
EH36 steel for shipbuilding - fracture documentation for CTOD test (plate thicnkness 40mm), a0/W = 0.6
Open Research DataThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
EH36 steel for shipbuilding - fracture documentation for CTOD test (plate thicnkness 50mm), a0/W = 0.6
Open Research DataThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
EH36 steel for shipbuilding - fracture documentation for CTOD test (plate thicnkness 50mm), a0/W = 0.5
Open Research DataThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
Technika łączności przy użyciu platform stratosferycznych. W: [CD-ROM] IXSympozjum Wojskowej Techniki Morskiej. Osiągnięcia i Perspektywiczne Zamie- rzenia w Dziedzinie Wojskowej Techniki Morskiej. Gdynia, 22-23.X.2003. Gdy- nia: Ośr. Bad.-Rozw. CTM**2003 [8 s.], 2 rys. bibliogr. 4 poz.
PublicationPrzedstawiono koncepcję realizacji łączności radiowej przy użyciu tzw. plat-form stratosferycznych HASP, wyniesionych techniką balonową na wysokość 21tysięcy km. Projekt ten przewiduje zawieszenie takich platform nad dużymiobszarami pozbawionymi infrastruktury telekomunikacyjnej, np. nad wybranymiakwenami morskimi, generującymi duże zapotrzebowanie na usługi telekomunika-cyjne, z szybką transmisją danych włącznie. Poruszono...
-
Bis(ć-di-tert-butylphosphido)bis[(triethylphospine)palladium(I)](Pd-Pd). A-cta Crist. Sec. E [online]**2003 vol. 59 [dostęp 31 May 2003] s. 376-377, 1 rys. 1 tab. bibliogr. 13 poz. Dost. w Intern. http://journals.iucr.org/e.Bis(ć-di-tert-butylphosphido)bis[(triethylphospine)palladium(I)](Pd-Pd).
PublicationBis.... powstaje w reakcji di-tert-butylfosfino-fosfanylideno-ĺ4-fosforanu zchlorkiem di-trietylofosfinopalladu(II) w obecności naftalidku sodu. Krystalizuje w grupie przestrzennej P1.
-
A decade of Poland`s integrated Road Safety Programme - economic develop-ment vs. road unsafety. W: [CD-ROM]. Conference proceedings. SORIC´02. 2nd Safety on Road Internationaload International Conference. Kingdom of Bah- rain, 21-23 October 2002. Bahrain: CTRS Univ. Bahrain**2002 [8 s. 5 rys. bibliogr. 5 poz. 10 lat Krajowego Programu Bezpieczeństwa Ruchu Drogowego w Polsce - rozwój ekonomiczny a niebezpieczeństwo ruchu.
PublicationReferat zawiera analizę doświadczeń z dziesięciu lat pracy oraz wdrożeń Kra-jowego Programu Bezpieczeństwa Ruchu Drogowego GAMBIT. Przedstawia również analizę przyczyn gwałtownego spadku liczby- śmiertelnych ofiar wypadków dro-gowych w Polsce w roku 2001.
-
Leszek Dąbrowski dr inż.
PeopleLeszek Dabrowski Senior Lecturer in the Chair of Machine Design and Automotive Engineering in the Department of Mechanical Engineering. He graduated in 1985 and obtained PhD in mechanical engineering, specializing in the field of tribology in 1997. His scientifical interests also include computational methods in engineering, biomechanics, medical engineering. His recent work focuses on the use of CT data in FEM and its application...
-
Józef Pacyna prof. dr hab. inż.
People -
Quantitative fluorescent determination of DNA – Ochratoxin a interactions supported by nitrogen-vacancy rich nanodiamonds
PublicationOchratoxin A (OTA) is a hazardous contaminant of a large variety of plant and animal originated food. Herein, we report an interaction of OTA with calf thymus DNA (ct DNA) on the nanodiamond surface. We employed multispectroscopic techniques to elucidate the binding mechanism of OTA with ct DNA. The fluorescence and UV–Vis spectroscopy results show that OTA binds to ds ct DNA and forms complexes. We obtained the binding constants...
-
Comparison of image pre-processing methods in liver segmentation task
PublicationAutomatic liver segmentation of Computed Tomography (CT) images is becoming increasingly important. Although there are many publications in this field there is little explanation why certain pre-processing methods were utilised. This paper presents a comparison of the commonly used approach of Hounsfield Units (HU) windowing, histogram equalisation, and a combination of these methods to try to ascertain what are the differences...
-
Monitoring the fracture process of concrete during splitting using integrated ultrasonic coda wave interferometry, digital image correlation and X-ray micro-computed tomography
PublicationThe paper deals with the continuous-time monitoring of mechanical degradation in concrete cubes under splitting. A series of experiments performed with integrated coda wave interferometry (CWI) and digital image correlation (DIC), supported with X-ray micro-computed tomography (micro-CT) is reported. DIC and micro-CT techniques were used to characterize the fracture process in detail. CWI method was proved to be effective in the...
-
Performance of a new commercial high-definition 3D patient specific quality assurance system for CyberKnife robotic radiotherapy and radiosurgery
PublicationConventional two dimensional and low-definition measurement techniques for dosimetric verification of radiotherapy treatment deliveries are no longer adequate in the era of hypofractionation and extremely high dose gradients. New quality assurance (QA) tools with 3D capability and high definition are urgently needed. The purpose of this study was to evaluate the performance of one of the first such commercial systems as applied...
-
Enhancing Renal Tumor Detection: Leveraging Artificial Neural Networks in Computed Tomography Analysis
PublicationRenal cell carcinoma is one of the most common cancers in Europe, with a total incidence rate of 18.4 cases per 100 000 population. There is currently significant overdiagnosis (11% to 30.9%) at times of planned surgery based on radiological studies. The purpose of this study was to create an artificial neural network (ANN) solution based on computed tomography (CT) images as an additional tool to improve the differentiation of...