Filters
total: 3926
-
Catalog
- Publications 2595 available results
- Journals 51 available results
- Conferences 7 available results
- People 40 available results
- Inventions 1 available results
- Projects 11 available results
- Research Teams 1 available results
- e-Learning Courses 26 available results
- Open Research Data 1194 available results
displaying 1000 best results Help
Search results for: SEMICONDUCTOR DEVICE MEASUREMENT
-
Operation of an ultra short fuse shunted by a semiconductor device: simulation and experiments.
PublicationW artykule przedstawiono ideę działania i wymagane cechy ultraszybkiego bezpiecznika w ograniczniku hybrydowym z równoległym elementem półprzewodnikowym. Eksperyment i modelowanie działanie bezpiecznika przeprowadzono dla spodziewanego prądu zwarciowego 2 kA. Symulacje wykonano przy użyciu programu polowego FLUX. Jego zastosowanie do modelowania ultrakrótkich bezpieczników zostało również przedstawione.
-
Device-independent quantum key distribution based on measurement inputs
PublicationWe provide an analysis of a family of device-independent quantum key distribution (QKD) protocols that has the following features. (a) The bits used for the secret key do not come from the results of the measurements on an entangled state but from the choices of settings. (b) Instead of a single security parameter (a violation of some Bell inequality) a set of them is used to estimate the level of trust in the secrecy of the key....
-
A Method of Lathe Checks Measurement; SMOF device and its software
Publication -
Low-power device simulator for micro-energy measurement methods testing
PublicationThe paper presents low-power device simulator designed for testing of micro-energy measurement methods. Such kind methods can be used for evaluation of power systems based on Energy Harvesting. The device allows to set the current consumption characteristic over the time, thus making possible playing the role of different types of low-power devices e.g. simulating sensor network node.
-
Experimental certification of an informationally complete quantum measurement in a device-independent protocol
PublicationMinimal informationally complete positive operator-valued measures (MIC-POVMs) are special kinds of measurement in quantum theory in which the statistics of their d2-outcomes are enough to reconstruct any d-dimensional quantum state. For this reason, MIC-POVMs are referred to as standard measurements for quantum information.Here, we report an experiment with entangled photon pairs that certifies, for what we believe is the first...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 24 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 24 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 53 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Measurement file of stainless stell shaft LSS1 and LSS2 with diameter 95,995 with 3d measurment device
Open Research Data3d point cloud consist of measured points on new stainless steel shaft used during testing hydrodynamic journal PEEK bearing.
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Automated measurement method for assessing thermal-dependent electronic characteristics of thin boron-doped diamond-graphene nanowall structures
PublicationThis paper investigates the electrical properties of boron-doped diamond-graphene (B:DG) nanostructures, focusing on their semiconductor characteristics. These nanostructures are synthesized on fused silica glass and Si wafer substrates to compare their behaviour on different surfaces. A specialized measurement system, incorporating Python-automated code, was developed for an in-depth analysis of electronic properties under various...
-
Implementation of constant component filter in measurements of random telegraph signal noise
PublicationNoise is generated in all semiconductor devices. The intensity of these fluctuations depends on used elements, manufacturing process, operating conditions and device type. The result noise is a superposition of different kinds of fluctuations like thermal noise, generation-recombination noise, 1/f noise, shot noise and Random Telegraph Signal (RTS) noise. The last one, RTS noise is observed as nonstationary impulse fluctuations....
-
A method of RTS noise identification in noise signals of semiconductor devices in the time domain
PublicationIn the paper a new method of Random Telegraph Signal (RTS) noise identification is presented. The method is based on a standardized histogram of instantaneous noise values and processing by Gram-Charlier series. To find a device generating RTS noise by the presented method one should count the number of significant coefficients of the Gram-Charlier series. This would allow to recognize the type of noise. There is always one (first)...
-
Ryszard Jan Barczyński dr hab. inż.
PeopleRyszard Jan Barczyński (b. 24 June 1957 in Gdańsk), Polish scientist, engineer, a specialist in solid state physics and electronic measurement techniques. In 1976, he obtained a high school diploma in the IV High School Tadeusz Kosciuszko in Torun. Higher education he graduated in 1981 at the Institute of Physics, Technical University of Gdansk in specialty of solid state physics, obtaining master's degree in engineering. Since...
-
Integrated circuit structure surface images obtained with contact capacitive imaging technique
Open Research DataThe measurements were done using NTEGRA Prima (NT-MDT) device. CSG 10Pt probe.
-
Piotr Płotka dr hab. inż.
PeoplePiotr Płotka received the M.Sc. and D.Eng. degrees in electronic engineering from the Gdansk University of Technology, Poland, in 1976 and 1985. In 2008 he received D.Sc. (Dr.Hab.) degree, also in electronic engineering, from the Institute of Electron Technology at Warsaw, Poland. From 1977 he was with Academy of Technology and Agriculture at Bydgoszcz, Poland and from 1981 with the Gdansk University of Technology. In cooperation...
-
MEASUREMENT
Journals -
Horizontally-split-drain MAGFET - a highly sensitive magnetic field sensor
PublicationWe propose a novel magnetic field sensitive semiconductor device, viz., Horizontally-Split-Drain Magnetic-Field Sensitive Field-Effect Transistor (HSDMAGFET) which can be used to measure or detect steady or variable magnetic fields. Operating principle of the transistor is based on one of the galvanomagnetic phenomena and a Gradual Channel Detachment Effect (GCDE) and is very similar to that of Popovic and Baltes's SDMAGFET. The...
-
A current-controlled FET
PublicationA novel semiconductor device, viz., Horizontally-Split-Drain Current-Controlled Field-Effect Transistor (HSDCCFET) with two control electrodes is proposed in this works. For the sake of brevity, the device can be called a CCFET. Operating principle of the proposed transistor is based on one of the galvanomagnetic phenomena, the Biot-Savart-Laplace law and a Gradual Channel Detachment Effect (GCDE). The transistor is dedicated...
-
Measurement Automation Monitoring
Journals -
Metrology and Measurement Systems
Journals -
Paweł Burdziakowski dr inż.
PeoplePaweł Burdziakowski, PhD, is a professional in low-altitude aerial photogrammetry and remote sensing, marine and aerial navigation. He is also a licensed flight instructor and software developer. His main areas of interest are digital photogrammetry, navigation of unmanned platforms and unmanned systems, including aerial, surface, underwater. He conducts research in algorithms and methods to improve the quality of spatial measurements...
-
HARDWARE AND SOFTWARE OF DIAGNOSTIC SYSTEM OF WHEELED TRACTORS = Hardwer i softwer systemu diagnostycznego ciągników kołowych
PublicationPodstawowym elementem systemu diagnostycznego jest komputer pokładowy Fujitsu FUTURO S100 z chłodzeniem pasywnym w wykonaniu odpornym na drgania i wstrząsy, z pamięcią Compact Flesh 16Gb. Do komputera dołączony jest monitor dotykowy NVOX LCD 10" VGA/FVAT. Oprogramowanie komputera obejmujesystem operacyjny Windows XP-2000, driver konwertera USB/DeviceNet oraz opracowany program diagnostyczny. Komputer połączony jest łączem USB z...
-
Validation of result of STM probe fabrication
Open Research DataThe scanning tunneling microscope [1] is a powerful research tool that allows, among other things, to obtain images with atomic resolution. A serious limitation of the described microscope is its limited applicability relating to conductive and semiconductor materials and the reproducibility of measurements depending on the preparation of the measuring...
-
A new nethod for RTS noise of semiconductor devices identification
PublicationIn the paper, a new method, called the noise scatterin pattern method (NSP method), for random telegraph signal noise identyfication in the inherent noise of semiconductor devices is described. A block diagram of a noise measurement system based on the NSP method is presented. Examples of patterns of the NSP method are presented.
-
Application of the Electronic Nose Technique to Differentiation between Model Mixtures with COPD Markers
PublicationABSTRACT The paper presents the potential of an electronic nose technique in the field of fast diagnostics of patients suspected of Chronic Obstructive Pulmonary Disease (COPD). The investigations were performed using a simple electronic nose prototype equipped with a set of six semiconductor sensors manufactured by FIGARO Co. They were aimed at verification of a possibility of differentiation between model reference mixtures with...
-
Materials for energy storage and conversion devices 2022/2023
e-Learning CoursesElectrodes: Metals as electrodes in aqueous and non-aqueous systems, metal nanoparticles. Collectors current. 3D, 2D, 1 D carbons, carbon nanomaterials. Organic semiconductors "Synthetic metals" - p-type, n-type. Inorganic semiconductors: oxides, selenides, sulfides, others. Intercalated electrodes. Mixed conductors (MIEC). Photo-active semiconductor materials. Electrolytes. Water electrolytes in commercial products. Electroactive...
-
Badanie wybranych właściwości wyłączników różnicowoprądowych typu F
PublicationW instalacjach elektrycznych niskiego napięcia instaluje się coraz więcej przekształtników energoelektronicznych (systemy fotowoltaiczne, instalacje ładowania pojazdów elektrycznych, układy napędowe o regulowanej prędkości obrotowej silnika), a mają one wpływ na dobór typu wyzwalania wyłączników różnicowoprądowych (AC, A, F lub B). W obwodach, w których pojawia się prąd różnicowy zawierający składowe o częstotliwości innej niż...
-
Semiconductor Devices
e-Learning Courseswesja angielskojęzyczna przedmiotu Przyrządy Półprzewodnikowe dla studentów z programu Erasmus
-
Gas sampling system for matrix of semiconductor gas sensors
PublicationSemiconductor gas sensors are popular commercial sensors applied in numerous gas detection systems. They are reliable, small, rugged and inexpensive. However, there are a few problem limiting the wider use of such sensors. Semiconductor gas sensor usually exhibits a low selectivity, low repeatability, drift of response, strong temperature and moisture influence on sensor properties. Sample flow rate is one of the parameters that...
-
Metody usuwania zakłóceń podczas pomiarów polowych widm Ramana
PublicationW pracy zostały scharakteryzowane źródła zakłóceń występujące podczas pomiarów widm Ramana w warunkach polowych oraz sposoby redukcji ich wpływu na jakość rejestrowanych widm. Zaprezentowano wpływ czasu integracji na jakość rejestrowanych widm w przypadkach, gdy szumy własne spektrometru mają składową typu 1/f, dominującą w zakresie małych częstotliwości. Przedstawiono także wyniki uzyskane podczas pomiarów z detekcją synchroniczną,...
-
Measurements and Measurement Systems [2021/22]
e-Learning CoursesThe aim of the course is to introduce theoretical and practical students with basic and advanced methods of measurement of various measured quantity and the design and function of the measurement systems.
-
MEASUREMENT SCIENCE & TECHNOLOGY
Journals -
Optoelectronic device for hematocrit measurements
PublicationAn optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed...
-
Auto adaptation of mobile device characteristics to various acoustic conditions
PublicationThe proposed methodology of auto adaptation of the mobile device characteristics to various acoustic conditions is presented in the paper. The first goal of this study was to determine the parameters of the acoustic path of the mobile device, for both transmitting (speaker) and receiver (microphone). Results of the measurement of characteristics of mobile devices were presented. Information about characteristics of individual parts...
-
SEMICONDUCTOR SCIENCE AND TECHNOLOGY
Journals -
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT
Journals -
Influence of vision measurement system spatial configuration on measurement uncertainty, based on the example of electric traction application
PublicationTechnical diagnostics plays a significant role in ensuring operational reliability of electrified rail transport. The most critical point in the transmission of electric energy to vehicles is the sliding contact of the current collector with the traction network. For this reason, work is currently being carried on new measuring methods, whose appliance allows for more complete diagnostics of the contact line and current collectors,...
-
Identification of inherent noise components of semiconductor devices on an example of optocouplers
PublicationIn the paper, a method of estimation of parameters of Gaussian and non-Gaussian components in the noise signal of semiconductor devices in a frequency domain is proposed. The method is based on composing estimators of two spectra, corresponding to noise (Gaussian component) and two-level RTS noise (non-Gaussian component). The proposed method can be applied for precise evaluation of the corner RTS frequency fRTS in the noise...