Filters
total: 1113
filtered: 848
-
Catalog
Chosen catalog filters
Search results for: IMPEDANCJA UDAROWA
-
EM-Driven Multi-Objective Design of Impedance Transformers By Pareto Ranking Bisection Algorithm
PublicationIn the paper, the problem of fast multi-objective optimization of compact impedance matching transformers is addressed by utilizing a novel Pareto ranking bisection algorithm. It approximates the Pareto front by dividing line segments connecting the designs found in the previous iterations, and refining the obtained candidate solutions by means of poll-type search involving Pareto ranking. The final Pareto set is obtained using...
-
Distribution of relaxation times as a method of separation and identification of complex processes measured by impedance spectroscopy
PublicationImpedance spectroscopy is one of the most commonly performed measurements to characterize electronic and electrochemical systems. Impedance spectra have limited resolution and many different processes may overlap what could be the reason of obstructions in its proper later analysis. Up to date, there are three approaches to solve this problem: examining impedance spectra itself, fitting spectra with equivalent circuits, and calculating...
-
A bisection‐based heuristic for rapid EM‐driven multiobjective design of compact impedance transformers
PublicationDesign of microwave structures is a multiobjective task where several conflicting requirements have to be considered at the same time. For contemporary circuits characterized by complex geometries, multiobjective optimization cannot be performed using standard population‐based algorithms due to high cost of electromagnetic (EM) evaluations. In this work, we propose a deterministic approach for fast EM‐driven multiobjective design...
-
New Method of Non-Linear Electrochemical Impedance Spectroscopy with an Amplitude-Modulated Perturbation Signal
PublicationThe paper presents a new method of non-linear electrochemical impedance spectroscopy (NLEIS), which allows fast and nondestructive evaluation of the corrosion rate and determination of the Tafel coefficients values for a corrosion system under investigation. This method employs amplitude modulation of the ac perturbation signal. The study demonstrated that it was possible to obtain impedance characteristic as a function of the...
-
Application of quartz crystal microbalance and dynamic impedance spectroscopy to the study of copper corrosion inhibitors
PublicationThe study investigates the application of Dynamic Electrochemical Impedance Spectroscopy (DEIS) and Electrochemical Quartz Crystal Microbalance (EQCM) techniques to examine the corrosion inhibition of copper by Benzotriazole and Sodium Folate in a 0.1 M NaCl solution. DEIS, an advanced version of Electrochemical Impedance Spectroscopy (EIS), allows for real-time monitoring of non-stationary electrochemical systems,...
-
Application of the short time Fourier transformation to the continuous frequency method of measurement of electrode impedance
PublicationPrzedstawiona została nowa metoda pomiaru impedancji elektrodowej. Wykorzystuje ona jako pobudzenie niestacjonarny sygnał napięciowy, którego częstotliwość jest liniową funkcją czasu. Zastosowanie transformacji STFT do analizy napięciowego sygnału pobudzenia i odpowiedzi prądowej umożliwia wyznaczenie widma impedancyjnego. Dokładność otrzymywanych wartości impedancji uwarunkowana jest wielkością okna i zastosowanej funkcji analizującej.
-
Evaluating the performance of organic coatings under mechanical stress using electrochemical impedance spectroscopy
PublicationMimo, iż znaczna liczba konstrukcji zabezpieczanych przy pomocy powłok poddawana jest cyklicznym naprężeniom mechanicznym, czynnik ten wydaje się być niedoceniany jako przyczyniający się do przyspieszonego niszczenia organicznych układów powłokowych. Celem pracy było zweryfikowanie czy powtarzające się naprężenia mechaniczne stanowią istotny element wpływający na skrócenie czasu eksploatacji systemów powłokowych. W tym celu układ:...
-
Using impedance spectroscopy to characterize and monitor protection aspects of organic coating systems on metal
PublicationOrganiczne powłoki ochronne stosowane są powszechnie do ochrony konstrukcji metalowych przed korozją i zużyciem mechanicznym. W pracy zaproponowano nowy typ sensora impedancyjnego, który może być zastosowany do ciągłej oceny właściwości barierowych i adhezyjnych systemów powłokowych w warunkach terenowych w sposób nieniszczący, bez konieczności stosowania naczyń z elektrolitem. Przedstawiono koncepcję czujnika oraz przykładowe...
-
DEIS evaluation of the relative effective surface area of AISI 304 stainless steel dissolution process in conditions of intergranulatar corrosion
PublicationWyniki przedstawione w tej pracy stanowią dalszą część badań dotyczących procesu roztwarzania wysokostopowej stali AISI 304 w warunkach zachodzenia korozji międzykrystalicznej z wykorzystaniem techniki dynamicznej elektrochemicznej spektroskopii impedancyjnej (DEIS). Po raz pierwszy zaprezentowano zmiany względnej powierzchni efektywnej procesu roztwarzania stali AISI 304 w warunkach zachodzenia korozji międzykrystalicznej w funkcji...
-
Pomiar impedancji pętli zwarciowej w obwodach z wyłącznikami różnicowoprądowymi i w obwodach zasilanych z UPS
PublicationW referacie przedstawiono teoretyczne podstawy pomiaru impedancji pętli zwarciowej oraz główne czynniki wpływające na jego dokładność. Omówiono pomiar impedancji pętli zwarciowej w obwodach chronionych wyłącznikami różnicowoprądowymi i zwrócono uwagę na problem zbędnego ich wyzwalania podczas tego pomiaru. Zaprezentowano specjalne metody pomiarowe, przeznaczone do obwodów z wyłącznikami różnicowoprądowymi. Przedstawiono również...
-
Pomiar impedancji pętli zwarciowej w obwodach chronionych wyłącznikami różnicowoprądowymi i w obwodach zasilanych z UPS
PublicationPrzedstawiono zasadę pomiaru impedancji pętli zwarciowej w instalacjach niskiego napięcia oraz omówiono jego specyfikę w obwodach chronionych wyłącznikami różnicowoprądowymi. Zaprezentowano specjalne metody pomiarowe, przeznaczone do obwodów z tymi wyłącznikami. Omówiono również problemy związane z wykonywaniem pomiaru impedancji pętli zwarciowej w obwodach zasilanych z UPS typu VFI.
-
W sprawie pomiaru impedancji pętli zwarciowej w układzie TN z wyłącznikami różnicowoprądowymi o IΔn ≤ 500 mA
PublicationUdzielono odpowiedzi na pytanie nadesłane do redakcji czasopisma INPE przez jednego z czytelników. Pytanie dotyczyło pomiaru impedancji pętli zwarciowej w układzie TN z wyłącznikami różnicowoprądowymi o IΔn ≤ 500 mA.
-
W sprawie pomiaru impedancji pętli zwarciowej w układzie TN z wyłącznikami różnicowoprądowymi o IΔn ≤ 500 mA
PublicationW rozdziale udzielono wyjaśnień na temat pomiaru impedancji pętli zwarciowej w układzie TN z wyłącznikami różnicowoprądowymi o IΔn ≤ 500 mA.
-
Wpływ błędów pomiaru okresu napięcia na dokładność wyznaczenia impedancji pętli zwarciowej w sieciach o napięciu odkształconym.
PublicationPrzedstawiono zagadnienie pomiaru impedancji pętli zwarciowej w sieciach o napięciu odkształconym. Omówiono metodę wykorzystującą wynik pomiaru napięcia przed i po załączeniu obciążenia pomiarowego oraz przesunięcie między tymi napięciami. Dokładność pomiaru w tej metodzie zależna jest od dokładności pomiaru okresu napięcia. Zaprezentowano analizę wpływu dwóch metod pomiaru okresu: cyfrową oraz przez próbkowanie sygnału z aproksymacją...
-
Dynamic electrochemical impedance spectroscopy of the adsorption and relaxation of polyaniline chains during potentiodynamic redox transformations
Publication -
Dynamic electrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses
Publication -
Enhanced capacitance of composite TiO2 nanotube/boron-doped diamond electrodes studied by impedance spectroscopy
Publication -
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Enhanced capacitance of composite TiO2 nanotube / boron-doped diamond electrodes studied by impedance spectroscopy
PublicationWe report on the novel composite nanostructures based on boron-doped diamond thin film grown on top of TiO2 nanotubes. The nanostructures made of BDD-modified titania nanotubes showed an increase in activity and performance when used as electrodes in electrochemical environments. The BDD thin films (~200-500 nm) were deposited using microwave plasma assisted chemical vapor deposition (MW PA CVD) onto anodically fabricated TiO2...
-
Impedance spectroscopy of BaTiO3 cubes suspended in lossy liquids as a physical model of two-phase system
PublicationTechniki spektroskopii impedancyjnej zostały wykorzystane do analizy modelu fizycznego w układzie dwufazowym w celu wyznaczanie stałej dielektrycznej dielektryka umieszczonego w cieczy. Badania eksperymentalne przeprowadzono z użyciem BaTiO3 jako materiału dielektrycznego, który został przygotowany jako kostki o jednakowej wielkości 2x2x1 mm3.
-
Dynamic electrochemical impedance spectroscopy of the adsorption and relaxation of polianiline chains during potentiodynamic redox transformations
PublicationZaprezentowano nowe podejście do analizy widm impedancyjnych uzyskanych dla warstwy przewodzącej polianiliny (PAni). Właściwości powyższej warstwy są często modelowane przy użyciu elementu stałofazowego (CPE), który w sposób dokładniejszy odzwierciedla wyniki eksperymentalne niż klasyczny element pojemnościowy (kondensator). W pracy zaproponowano nowy elektryczny obwód zastępczy oparty na modelu adsorpcyjnym Frumkin-Melik-Gaikazyan,...
-
Study of Direct Methanol Fuel Cell Process Dynamics Using Dynamic Electrochemical Impedance Spectroscopy
PublicationA new technique, which was developed to characterize the direct methanol fuel cell under work conditions, has been presented in this paper. The impedance measurements were made using dynamic electrochemical impedance spectroscopy research technique in the galvanostatic mode, using multiple sinusoidal excitation. Obtained results show, that together with an increase of the temperature and working load, the global impedance...
-
Development of the Mobile PoC Graphene-Based Biosensing Device Using Electrochemical Impedance Spectroscopy (EIS)
Publication -
A microcontroller system for measurement of three independent components in impedance sensors using a single square pulse
PublicationOpracowano nową metodę pomiaru w dziedzinie czasu i wyznaczania trzech składowych elementów modelu czujnika impedancyjnego oraz zaimplementowano ją w inteligentnym czujniku impedancji sterowanym 8-bitowym mikrokontrolerem. Metoda bazuje na pobudzeniu dzielnika napięciowego składającego się z rezystora pełniącego funkcję konwertera prąd na napięcie i z czujnika impedancji pojedynczym impulsem prostokątnym o czasie trwania T bezpośrednio...
-
Optimization of the Relative Humidity of Reactant Gases in Hydrogen Fuel Cells Using Dynamic Impedance Measurements
PublicationWater management is a key factor affecting the efficiency of proton exchange membrane fuel cells (PEMFCs). The currently used monitoring methods of PEMFCs provide limited information about which processes or components that humidity has a significant impact upon. Herein, we propose the use of a novel approach of impedance measurements using a multi-sinusoidal perturbation signal, which enables impedance measurements under dynamic...
-
On deterministic procedures for low-cost multi-objective design optimization of miniaturized impedance matching transformers
PublicationPurpose This paper aims to investigate deterministic strategies for low-cost multi-objective design optimization of compact microwave structures, specifically, impedance matching transformers. The considered methods involve surrogate modeling techniques and variable-fidelity electromagnetic (EM) simulations. In contrary to majority of conventional approaches, they do not rely on population-based metaheuristics, which permit lowering...
-
Surrogate modeling of impedance matching transformers by means of variable‐fidelity electromagnetic simulations and nested cokriging
PublicationAccurate performance evaluation of microwave components can be carried out using full‐wave electromagnetic (EM) simulation tools, routinely employed for circuit verification but also in the design process itself. Unfortunately, the computational cost of EM‐driven design may be high. This is especially pertinent to tasks entailing considerable number of simulations (eg, parametric optimization, statistical analysis). A possible...
-
The non-invasive evaluation of heart function in patients with an acute myocardial infarction: The role of impedance cardiography
PublicationBackground: The purpose of this study was to analyze hemodynamic changes in patients treated with percutaneous coronary intervention (PCI) at an early stage of acute myocardial infarction (AMI) and at one-month follow-up. Methods: Patients with AMI (n = 27) who underwent PCI were analyzed using impedance cardiography (ICG). ICG data were collected continuously (beat by beat) during the whole PCI procedure and thereafter at every...
-
Electrochemical behaviour of Cr coating in acidic sulphate solution studied by cyclic polarization and impedance spectroscopy
PublicationOdporność korozyjną powłok chromowych w 0.01 M H2SO4 zbadano metodami woltamperometrii cyklicznej i spektroskopii impedancyjnej. Stwierdzono, że właściwości ochronne powłoki chromowej w kontakcie z powietrzem wzrastają dzięki tworzeniu się warstwy tlenkowej zapełniającej defekty w powłoce. W trakcie polaryzacji anodowej następuje częściowe roztwarzanie tej warstwy i penetracja agresywnego środowiska do podłoża (stali), co powoduje...
-
Dynamic elektrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses.
PublicationDynamiczna elektrochemiczna spektroskopia impedancyjna umożliwia badanie podatności i odporności korozyjnej różnych materiałów konstrukcyjnych, a w szczególności określenie właściwości elektrochemicznych warstw pasywnych występujących na ich powierzchni. W wielu przypadkach pęknięcie warstwy pasywnej pod wpływem działania naprężeń rozciągających prowadzi do korozji naprężeniowej. Z tego względu badania pękania warstw pasywnych...
-
Dynamic electrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses.
PublicationDynamiczna Elektrochemiczna Spektroskopia Impedancyjna umożliwia badanie podatności i odporności korozyjnej różnych materiałów konstrukcyjnych, a w szczególności określenie właściwości elektrochemicznych warstw pasywnych występujących na ich powierzchni. W wielu przypadkach pęknięcie warstwy pasywnej pod wpływem działania naprężeń rozciągających prowadzi do korozji naprężeniowej. Z tego względu badania pękania warstw pasywnych...
-
Zastosowanie transformacji STFT z oknem analizującym o zmiennej długości w pomiarze impedancji elektrodowej metodą ciągłego skanowania częstotliwościowego
PublicationPrzedstawiona została nowa metoda pomiaru impedancji elektrodowej. Wykorzystuje ona jako pobudzenie niestacjonarny sygnał napięciowy, którego częstotliwość jest logarytmiczną funkcją czasu. Zastosowanie transformacji STFT do analizy napięciowego sygnału pobudzenia i odpowiedzi prądowej umożliwia wyznaczenie widma impedancyjnego.
-
The impedance method of monitoring the degradation of rubber linings in applications where progressive deterioration is the predominant failure mechanism
Publication -
Evaluation of cavitation erosion–corrosion degradation of mild steel by means of dynamic impedance spectroscopy in galvanostatic mode
Publication -
The fixed state in impedance measurements of a two-step electrode reaction proceeding with accompanying adsorption of an intermediate product
Publication -
Instantaneous impedance monitoring of AA 7075 aluminum alloy corrosion in borate buffer with admixed chloride ions
PublicationThe study presents a research capabilities of Dynamic Electrochemical Impedance Spectroscopy (DEIS) as a tool used for instantaneous on-line monitoring of corrosion processes on the example of AA 7075 aluminum alloy. A borate buffer with admixed chloride ions in a quantity ranging from 0.05 to 25 mM was used to represent different types of corrosion attack. The surface of samples specimens was evaluated before and after the tests...
-
Impedance plethysmography as a tool for assessing exertion-related blood flow changes in the lower limbs in healthy subjects
Publication -
Impedance spectroscopy studies on hybrid materials consisting of poly(3,4-ethylenedioxythiophene) and iron, cobalt and nickel hexacyanoferrate
PublicationBadania warstw polimeru pEDOT modyfikowanego heksacyjanożelazianami żelaza, kobaltu i niklu przeprowadzono za pomocą spektroskopii impedancyjnej (SI). Wykazano, że materiały hybrydowe charakteryzują się dobrą stabilnością. Warstwy testowano w zakresie temperatur od 283 do 313K. w kontakcie z wodnym roztworem KCl. Wysokie współczynniki dyfuzji wskazują na możliwości wykorzystania układów jako przewodników jonowych.
-
Evaluation of cavitation erosion-corrosion degradation of mild steel by means of Dynamic Impedance Spectroscopy in galvanostatic mode
PublicationPrzedstawiono wyniki badań degradacji stali węglowych na skutek oddziaływania erozji-korozji kawitacyjnej. Do analizy wykorzystano technikę Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej w trybie galwanostatycznym, bliżej odwzrorowującym warunki naturalne. Do oceny stopnia degradacji posłużyły również funkcja ubytku masy MDPR oraz obrazy mikroskopowe SEM. Potwierdzono wpływ łączonej degradacji erozyjno-korozyjnej na...
-
Electrochemical properties of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrodes in solid oxide cells: Impedance study of symmetrical electrodes
PublicationThis work evaluates porous Sr0.86Ti0.65Fe0.35O3 (STF35) as a possible oxygen electrode material for Solid Oxide Cells. The powder synthesis was performed by solid state method. Characterization included DC electrical conductivity study of sintered bulk samples and impedance spectroscopy study of symmetrical electrodes deposited on gadolinium doped ceria substrates. Measurements were carried out in atmospheres with different pO2...
-
Instantaneous Impedance Analysis of Non-Stationary Corrosion Process: a Case Study of Carbon Steel in 1M HCl
PublicationThe paper concerns the problem of evaluation of stationarity of carbon steel corrosion in 1M HCl. Comparison of corrosion rate with addition of corrosion inhibitor to the reference measurement is the most often used way of evaluating inhibitor efficiency. Such an approach is valid only if corrosion rate is a stationary process. Two complementary techniques were used simultaneously: volumetric analysis of evolved hydrogen and instantaneous...
-
Teoretyczny opis metody pomiaru chwilowego widma impedancyjnego. Theoretical description of the measuring of instantenous impedance spectra
PublicationPrzedstawiony został teoretyczny opis wyznaczania chwilowego widma impedancyjnego. Połączenie szumu pseudo-białego oraz metody krótkoczasowej transformacji Fouriera pozwala na wyznaczenie zmian widma impedancyjnego w funkcji czasu. Teoretyczne podstawy nowej metody pomiarowej wskazują na możliwość zastosowania jej do procesów niestacjonarnych.
-
New possibilities of the passive layer cracking dynamics detection using a new Dynamic Electrochemical Impedance Spectroscopy.
PublicationNowa metoda Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej opracowana w Katedrze Elektrochemii, Korozji i Inżynierii Materiałowej Politechniki Gdańskiej daje możliwości określania charakterystyki impedancyjnej w dziedzinie czasu podczas procesu pękania ochronnej warstwy pasywnej. Fakt ten jest związany z procedurą analizującą wspomnianej techniki, która umożliwia selektywną analizę czasowo-częstotliwościową uzyskanych...
-
Mikroprocesorowy miernik impedancji pętli zwarciowej eliminujący wpływ odkształcenia napięcia przez regulację argumentu obciążenia pomiarowego. - [przedruk rek nr 128902]
PublicationW artykule przedstawiono problematykę pomiaru impedancji pętli zwarciowej w sieciach o napięciu odkształconym. Zaproponowano metodę pomiaru impedancji pętli eliminującą wpływ odkształcenia napięcia i zbudowano mikroprocesorowy miernik, który ją wykorzystuje. W mierniku zastosowano impedancyjne obciążenie pomiarowe o stałej wartości modułu i regulowanym automatycznie argumencie. Przy zrównaniu argumentu impedancji obciążenia pomiarowego...
-
Dynamic Electrochemical Impedance Spectroscopy (DEIS) as a Tool for Analyzing Surface Oxidation Processes on Boron-Doped Diamond Electrodes
Publication -
Investigation of the electrochemical behaviour of AA1050 aluminium alloy in aqueous alkaline solutions using Dynamic Electrochemical Impedance Spectroscopy
PublicationThe paper presents the electrochemical behaviour of aluminium alloy AA1050 in aqueous alkaline media in the pH range 14–8.5. Electrochemical study was applied in order to obtain comprehensive information on the mechanism and kinetics of the process of anodic dissolution of aluminium, supplemented by monitoring of surface topography using an electron microscope. The corrosion rate of AA1050 increases with increasing concentration...
-
Dynamic Electrochemical Impedance Spectroscopy (DEIS) as a Tool for Analyzing Surface Oxidation Processes on Boron-Doped Diamond Electrodes
PublicationSurface oxidation processes play a key role in understanding electrochemical properties of boron-doped diamond (BDD) electrodes. The type of surface termination groups, which create the potential window of electrolytic water stability or hydrophobicity, influences such properties. In this study the kinetics of oxidation process under anodic polarization were studied in situ by means of Dynamic Electrochemical Impedance Spectroscopy...
-
Electrical and mechanical characterization of two-phase alloys by means of scanning probe microscopy in dynamic impedance spectroscopy mode
PublicationDynamic impedance spectroscopy, evaluated for measuring non-stationary systems, was used in combination with scanning probe microscope. Using this approach, localized impedance measurements in the AFM contact mode could be carried out. Additionally, impedance–force curves were made at each phase of investigated materials to illustrate the relation between impedance and the force applied to a probe. Therefore, correlation of electrical...
-
Design of Highly Selective Dual Band Band Stop Filter using Dual-Path Step Impedance Resonator
Publication -
Determination of occurrence of anodic excursion peaks by dynamic electrochemical impedance spectroscopy, atomic force microscopy and cyclic voltammetry
PublicationStruktura oraz skład warstw anodowych na ołowiu najbardziej zależy od; dodatków stopowych, stężenia kwasu siarkowego oraz od zakresu potencjału. Zjawisko powstawania pików "anodic excursion peaks" od zawsze było w centrum uwagi wielu naukowców. W tej pracy zachowanie się powyższego zjawiska (AEP) zostało zbadane metodami dynamicznej elektrochemicznej spektrokopii impedancyjnej, mikroskopu sił atomowych oraz chronowoltamperometrii....