Filters
total: 578
filtered: 424
-
Catalog
- Publications 424 available results
- Journals 3 available results
- Conferences 1 available results
- People 7 available results
- Inventions 5 available results
- Projects 1 available results
- Laboratories 1 available results
- Research Teams 1 available results
- e-Learning Courses 78 available results
- Open Research Data 57 available results
Chosen catalog filters
Search results for: capp
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublicationIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
Analysis of Ferroresonance Mitigation Effectiveness in Auxiliary Power Systems of High-Voltage Substations
PublicationFerroresonance in power networks is a dangerous phenomenon, which may result in overcurrents and overvoltages, causing damage to power equipment and the faulty operation of protection systems. For this reason, the possibility of the occurrence of ferroresonance has to be identified, and adequate methods need to be incorporated to eliminate or reduce its effects. The aim of this paper is to evaluate the effectiveness of ferroresonance...
-
Uproszczone modelowanie linii kablowych wysokiego napięcia a napięcia indukowane w żyłach powrotnych – studium przypadku
PublicationLinie kablowe, obok linii napowietrznych, są jednym z podstawowych elementów składowych systemów elektroenergetycznych. Stosowane są głównie na terenach zurbanizowanych, gdzie prowadzenie linii napowietrznych jest mocno utrudnione lub wręcz niemożliwe. Linie kablowe wysokiego napięcia budowane są głównie z wykorzystaniem kabli, które oprócz żyły roboczej mają również współosiową żyłę powrotną. Istnieje kilka układów pracy takich...
-
Overheating of underground power cable line due to its partial exposition to solar radiation
PublicationCurrent-carrying capacity of underground power cable lines depends, among others, on thermal resistivity of the soil and cables layout: trefoil formation, flat formation with or without spacing. If conditions for heat transfer in the ground are favorable, the current-carrying capacity is relatively high. Therefore, it generates risk of the power cables overheating, if part of the cable line is located vertically in the air, to...
-
Selection of energy storage units by genetic algorithm for mitigating voltage deviations
PublicationIn recent years, energy storage units have become very popular. They are applied both for economic and technical purposes. Unfortunately, the cost of such devices is still high and selecting their proper location and rated power have to be performed precisely. In this paper, a Genetic-Algorithm-based optimization method for selecting the best configuration of energy storage units in the power network is proposed. The presented...
-
Effect of solar radiation on current-carrying capacity of PVC-insulated power cables – the numerical point of view
PublicationPower cables are usually buried in the soil, which results in their relatively high current-carrying capacity. However, there are cases in which the starting/final section of a cable line runs along a pole of an overhead power line. Power cables can be directly exposed to solar radiation then, and this negatively influences their current-carrying capacity as well as estimated life of the cables’ insulation. An analysis of thermal...
-
Koncepcja przyłączenia elektrowni fotowoltaicznej na terenie działki nr 43 obręb 2 Nowy Staw do istniejącej sieci
PublicationW Pracy przedstawiono wstępną koncepcję przyłączenia elektrowni fotowoltaicznej do sieci średniego napięcia na terenie gminy Nowy Staw.
-
Evaluation Of Single Pole Auto-Reclosing Effectiveness With Nonlinear Secondary Arc Model
PublicationThe paper discusses two evaluation methods of single pole auto-reclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a non-linear secondary arc implementation is presented. The authors indicate, that precise representation of secondary electric arc leads to more...
-
Induced Sheath Voltages In 110 Kv Power Cables – Case Study
PublicationThe paper considers shock hazard due to induced sheath voltages in 110 kV power cables. Various configurations of the metallic sheaths bonding and earthing (single-point bonding, both-ends bonding, cross-bonding) are analysed. Taking into account shock hazard and ability of the system to power transfer an optimal configuration is proposed.
-
Study of the Operation of Synchronous Generator Voltage Regulator During the Creation of Post Blackout Start-up Path
PublicationThis paper presents the influence of automatic voltage regulator (AVR) of synchronous generator on the process of creation of post black-out start-up path. Two elements of AVR have a significant impact on this process: underexcitation limiter (UEL) and load compensation (LC). The authors present a theoretical investigation and simulation results that illustrate how the mentioned elements of AVR affect voltage levels in a power...
-
Induced sheath voltages in 110 kV power cables – case study
PublicationThis paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse...
-
Secondary arc modelling for single pole reclosing analyses
PublicationThe paper discusses two evaluation methods of single pole auto-reclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage calculation results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a nonlinear secondary arc model implementation is presented. The paper presents the study results for the three types of EHV transmission...
-
Evaluation of bearing and journal damage in MAN 9L40-54 engines installed on M/V STENA SCANDINAVICA ferry
PublicationThe following report was requested by Remontowa Shiprepair Yard (RSY) S.A. in Gdansk ´ (contract no. 4/2018/EX/U, dated 13.02.2018) and prepared based on the materials received from RSY, two on-board inspections and the participation of the contractors in three conferences with RSY representativesi. The goal of the analysis performed by the experts of Gdansk University of Technology was ´ to determine the character of the bearing...
-
Risk of power cables insulation failure due to the thermal effect of solar radiation
PublicationLow-voltage, as well as high-voltage power cable lines, are usually buried in the ground. The ampacity of the power cables in the ground mainly depends on the thermal resistivity of the soil, which may vary in a wide range. A common practice in power cable systems performance is to supply them from a pole of an overhead line. If so, a section of the line is located in free air and can be directly exposed to solar radiation. In...
-
Evaluation of fire hazard in electrical installations due to unfavorable ambient thermal conditions
PublicationEvaluation of fire hazard caused by electrical installations is a difficult and important topic, and it limits the possibility of loss of life or health of people, as well as the occurrence of significant property damage. In particular, this hazard was caused by power cables and especially photovoltaic (PV) installations. The authors proved that power cables directly exposed to strong solar radiation are likely to exceed maximum...
-
Voltage variations and their reduction in a rural low-voltage network with PV sources of energy
PublicationRenewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...
-
Wpływ warunków otoczenia na obciążalność prądową długotrwałą kabli elektroenergetycznych
PublicationObciążalność prądowa długotrwała przewodów i kabli elektroenergetycznych zależy m.in. od sposobu ich ułożenia i warunków otoczenia. Kabel elektroenergetyczny ułożony w zmiennych warunkach, np. ziemia – woda – powietrze ma obciążalność prądową długotrwałą wynikającą z najgorszych warunków otoczenia pod względem oddawania ciepła. W artykule zaprezentowano wyniki badań symulacyjnych dla linii kablowej niskiego napięcia umieszczonej...
-
Nonlinear secondary arc model use for evaluation of single pole auto-reclosing effectiveness
PublicationPurpose – The purpose of this paper is to discuss two evaluation methods of single pole autoreclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a nonlinear secondary arc implementation is presented. Design/methodology/approach – A computer simulation studies were...
-
EHV transmission lines wires location on line operation issues - case studies
PublicationTransmission lines towers construction affects the line parameters and influences on its operation in the future. Misguided design of the tower can lead to serious problems such as overvoltages, electric arc extinction difficulties, voltage asymmetry, resonance phenomena or increasing of magnetic field near the line. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors....
-
Synthesis of bimetallic Co–Pt/cellulose nanocomposites for catalytic reduction of p-nitrophenol
PublicationIn this study, bimetallic nanoparticles (NPs) of Co–Pt anchored on cellulose nanofibers (CNFs) for catalytic applications were synthesized via a sonochemical approach. The electro-spinning technique was employed for the synthesis of CNFs from cellulose acetate. The thorough characterization of synthesised Co–Pt/CNF nanocomposites was performed with the help of scanning electron microscopy (SEM), Fourier transform infra-red (FT-IR)...
-
Informal Settlements and International Migrants: The city of Rome (Italy) as Case Study
PublicationToday, urbanization is happening at an unprecedentedly rapid rate, owing heavily to the influx of migrants. Empirical evidence shows the development of informal settlements in cities as a result of migration, including Rome. Furthermore, information on informal settlements is either insufficient or inadequate, which makes it challenging for architects, urban planners, and policymakers to form viable solutions to deal with the situations...
-
Restrained differential of a graph
PublicationGiven a graph $G=(V(G), E(G))$ and a vertex $v\in V(G)$, the {open neighbourhood} of $v$ is defined to be $N(v)=\{u\in V(G) :\, uv\in E(G)\}$. The {external neighbourhood} of a set $S\subseteq V(G)$ is defined as $S_e=\left(\cup_{v\in S}N(v)\right)\setminus S$, while the \emph{restrained external neighbourhood} of $S$ is defined as $S_r=\{v\in S_e : N(v)\cap S_e\neq \varnothing\}$. The restrained differential of a graph $G$ is...
-
Telomere uncapping by common oxidative guanine lesions: Insights from atomistic models
PublicationOxidative damage to DNA is widely known to contribute to aging and disease. This relationship has been extensively studied for telomeres – structures that cap chromosome ends – due to their role in cell proliferation and senescence, and exceptional susceptibility to oxidation. Indeed, the repetitive telomeric DNA sequence contains the 5′-GGG-3′ motif that has the lowest ionization potential of all trinucleotides. Accordingly, experiments...
-
A mechanistically approached review upon assorted cell lines stimulated by athermal electromagnetic irradiation
PublicationThe probable influence of electromagnetic irradiation on cancer treatment has been deduced from the interaction of artificial electromagnetic emissions with biological organisms. Nonetheless, the suspected health effects induced by electromagnetic-based technology imply that such a treatment may contaminate the adjacent healthy cells. Thus, gaining mechanistic insights into the problem is required to avoid athermal health hazards....
-
Modelling long-term technological transition of Polish power system using MARKAL: Emission trade impact
PublicationThe need for technological transition of electricity production becomes a global problem. However, in coal-dominated Polish power system this need is even more crucial than anywhere, since technical lifetime of the most domestic power plants is ending. In this paper, the impact of the EU Emission Trading Scheme (EU ETS) for CO2 combined with sulfur dioxide (SO2) and nitrogen oxides (NOx) emission trading mechanism on power technology...
-
Novel anticancer strategy aimed at targeting shelterin complexes by the induction of structural changes in telomeric DNA: hitting two birds with one stone.
PublicationThe ends of chromosomes in mammals are composed of telomeric DNA containing TTAGGG repeats, which bind specific proteins called shelterins. This telomeric DNA together with shelterins form a cap that protects the ends of chromosomes from being recognized as sites of DNA damage and from chromosomal fusions. Many very successful antitumor drugs used in the treatment of cancer patients bind to DNA, some of them with a prominent sequence...
-
DC and AC Conductivity, Biosolubility and Thermal Properties of Mg-Doped Na2O–CaO–P2O5 Glasses
PublicationBioactive glasses have recently been extensively used to replace, regenerate, and repair hard tissues in the human body because of their ability to bond with living tissue. In this work, the effects of replacing Na2O with MgO on the electrical, biosolubility, and thermal properties of the target glass 10Na2O–60P2O5–30CaO (in mol%) were investigated. The electrical properties of the glasses were studied with the impedance spectroscopy...
-
Harmonics produced by traction substations – computer modelling and experimental verification
PublicationVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion include traction rectifiers. This paper presents results of the computer investigation of...
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Higher harmonics produced by traction substations – computer modelling and experimental verification
PublicationVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers, although the rms value of load current does not exceed their current-carrying capacity. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion...
-
WPŁYW GENERACJI ROZPROSZONEJ NA STRATY MOCY CZYNNEJ W SIECIACH DYSTRYBUCYJNYCH WN I SN
PublicationW referacie przedstawiono wpływ lokalizacji generacji rozproszonej na pracę sieci dystrybucyjnej WN i SN. W przypadku sieci SN rozpatrzono przypadki lokalizacji źródła blisko GPZ oraz w głębi sieci z uwzględnieniem jej topologii: sieć promieniowa oraz dwustronnie zasilana. Rozpatrzono również aspekty wpływu źródeł na rozpływy mocy, straty mocy, poziomy napięć oraz pracę regulatora transformatora w GPZ. W przypadku sieci WN przeanalizowano...
-
Availability of UAV Fleet Evaluation Based on Multi-State System
PublicationUnmanned Aerial Vehicle (UAV) applications are extended extremely. Some applications need to use several UAVs for a general mission which can be considered a UAV fleet. One of the important characteristics for the evaluation of a UAV or UAV fleet is reliability. There are studies in which methods for analysis of their reliability are considered. Reliability analysis of UAV fleets is less frequently studied, although a single UAV...
-
Estimation of the Maximum Permissible PV Power to be Connected to the MV Grid
PublicationIn recent decades, a significant increase in the share of renewable energy sources in power grids at various voltage levels has been observed. A number of articles have been published highlighting emerging problems in low-voltage grids with a large share of prosumers and in medium- and high-voltage grids to which photovoltaic (PV) plants are connected. The article analyzes the medium-voltage grid in terms of the possibility of...
-
Study of Soil Temperature and Moisture Changes in a Physical Model of an Underground Cable Line
PublicationThe ampacity of power cables is highly dependent on the thermal resistivity of the soil in which they are laid. The lower it is, the higher this ampacity. The thermal resistivity of the soil decreases as its moisture increases. Therefore, it is preferable that the soil around the cables has high moisture. Unfortunately, the heat generated in heavily loaded cables causes the migration of moisture from the surrounding soil, which...
-
Wykorzystanie logiki rozmytej do regulacji napięcia w systemie elektroenergetycznym z wybranymi odnawialnymi źródłami energii
PublicationW ostatnich latach w krajowym systemie elektroenergetycznym liczba i moc odnawialnych źródeł energii znacząco wzrosły. Źródła te można wykorzystać nie tylko do produkcji tzw. czystej energii elektrycznej, ale również do poprawy warunków napięciowych w tym systemie. W artykule przedstawiono koncepcję układu regulacji napięcia w systemie elektroenergetycznym z przyłączonymi w pewnym obszarze: farmą wiatrową, farmą fotowoltaiczną,...
-
Voltage control in a power system with renewable sources of energy
PublicationIntensive development of distributed generation in power systems, caused by the European Union energy policy, gives possibility for improving safety in power delivery as well as optimizing the costs of the systems functioning. In this context, distributed generation can be used for voltage control in power systems – it can be performed by the control of reactive power of each source of energy or a group of energy sources. This...
-
Integrated algorithm for selecting the location and control of energy storage units to improve the voltage level in distribution grids
PublicationThis paper refers to the issue that mainly appears in distribution grids, where renewable energy sources (RES) are widely installed. In such grids, one of the main problems is the coordination of energy production time with demand time, especially if photovoltaic energy sources are present. To face this problem, battery energy storage units (ESU) can be installed. In recent years, more and more attention has been paid to optimizing...
-
Energy Efficiency and Economic Policy: Comprehensive Theoretical, Empirical, and Policy Review
PublicationIn this paper, we analyze the role of economic policy in prompting energy efficiency. This study reviews three aspects, theoretical, empirical, and existing policies to evaluate the relationship of energy efficiency and economic policy. This study furthermore identifies the existing issues from a policy perspective in energy efficiency. Although not all public policies may be justified, it suggests that these types of financial...
-
Analiza wpływu wybranych odnawialnych źródeł energii na straty mocy czynnej i biernej w systemie elektroenergetycznym
PublicationMoc zainstalowana oraz produkcja energii elektrycznej z odnawialnych źródeł energii od kilkunastu lat systematycznie w Polsce wzrasta. Należy spodziewać się, że tendencja ta w najbliższych latach zostanie utrzymana. Dość dużym zainteresowaniem cieszą się źródła wiatrowe oraz źródła fotowoltaiczne, co sprawia, że przy znacznych ich mocach zainstalowanych konieczne staje się badanie wpływu tych źródeł na system elektroenergetyczny....
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Fire-Retardant Flexible Foamed Polyurethane (PU)-Based Composites: Armed and Charmed Ground Tire Rubber (GTR) Particles
PublicationInadequate fire resistance of polymers raises questions about their advanced applications. Flexible polyurethane (PU) foams have myriad applications but inherently suffer from very high flammability. Because of the dependency of the ultimate properties (mechanical and damping performance) of PU foams on their cellular structure, reinforcement of PU with additives brings about further concerns. Though they are highly flammable and...
-
DEPO: A dynamic energy‐performance optimizer tool for automatic power capping for energy efficient high‐performance computing
PublicationIn the article we propose an automatic power capping software tool DEPO that allows one to perform runtime optimization of performance and energy related metrics. For an assumed application model with an initialization phase followed by a running phase with uniform compute and memory intensity, the tool performs automatic tuning engaging one of the two exploration algorithms—linear search (LS) and golden section search (GSS), finds...
-
The influence of food phytochemicals on cyclic phosphodiesterase 4 (PDE4) activity
PublicationCyclic phosphodiesterase 4 (PDE4) belongs to family of cyclic phosphodiesterases, which are expressed predominantly in inflammatory cells, airway smooth muscles, cardiovascular tissues and brain. Inhibitors of this family of enzymes found medicinal applications as antidepressants, antiinflamatory drugs (mainly in airway diseases) or antiasthmatics (Ibudilast). PDE4 inhibitors are also being tested for preventing the development...
-
Modeling external carbon addition in combined N-P activated sludge systems with an extension of the IWA Activated Sludge Models
PublicationThe aim of this study was to expand the IWA Activated Sludge Model No. 2d (ASM2d) to account for a newly defined readily biodegradable substrate that can be consumed by polyphosphate accumulating organisms (PAOs) under anoxic and aerobic conditions, but not under anaerobic conditions. The model change was to add a new substrate component and process terms for its use by PAOs and other heterotrophic bacteria under anoxic and aerobic...
-
Modeling external carbon addition in combined N-P activated sludge systems with an extension of the IWA Activated Sludge Models
PublicationThe aim of this study was to expand the IWA Activated Sludge Model No. 2d (ASM2d) to account for a newly defined readily biodegradable substrate that can be consumed by polyphosphate accumulating organisms (PAOs) under anoxic and aerobic conditions, but not under anaerobic conditions. The model change was to add a new substrate component and process terms for its use by PAOs and other heterotrophic bacteria under anoxic and aerobic...
-
Dual-Activity Fluoroquinolone-Transportan 10 Conjugates offer alternative Leukemia therapy during Hematopoietic Cell Transplantation
PublicationHematopoietic cell transplantation (HCT) is often considered a last resort leukemia treatment, fraught with limited success due to microbial infections, a leading cause of mortality in leukemia patients. To address this critical issue, we explored a novel approach by synthesizing antileukemic agents containing antibacterial substances. This innovative strategy involves conjugating fluoroquinolone antibiotics, such as ciprofloxacin...
-
The effect of road restraint systems on the level of road safety - Polish experience
PublicationRoadside accidents happen when a vehicle runs off the road. The majority of these accidents are very severe because leaving the road is usually followed by hitting a solid obstacle (tree, pole, support, culvert front wall, barrier). Roadsides are some of the most important issues of road safety. They have been studied for years to identify roadside hazards and the effectiveness of road safety measures such as restraint systems....
-
Layer-by-layer polymer deposited fabrics with superior flame retardancy and electrical conductivity
PublicationSmart and multifunctional textiles and fabrics are progressively developing, such that multifunctional fabrics are becoming more widespread. We elaborated herein multi-layered flax fabrics with superior flame retardancy and conductivity, which revealed fireproof feature while keeping conductivity during burning. The flax fabric was reinforced by layer-by-layer (LbL) deposition of sodium polyacrylate (SPA), polyethylenimine (PEI),...
-
Crystalline Silicon (c-Si)-Based Tunnel Oxide Passivated Contact (TOPCon) Solar Cells: A Review
Publication