Search results for: INTERFEROMETR FABRY-PEROT
-
Computer Support of Analysis of Optical Spectra Measurements
PublicationThe verification of measurement errors has a big impact on the assessment of the accuracy of conducted measurements and obtained results. In many cases, computer simulation results are compared with measurement results in order to evaluate measurement errors. The purpose of our research was to check the accuracy of measurements made with a Fabry–Perot interferometer working in the transmission mode. In the measurement setup, a...
-
The Influence of PEDOT to PSS Ratio on the Optical Properties of PEDOT:PSS Thin Solid Films - Insight from Spectroscopic Ellipsometry
Publication -
Differences in Electrochemically Deposited PEDOT(PSS) Films on Au and Pt Substrate Electrodes: A Quartz Crystal Microbalance Study
Publication -
Electrodes consisting of PEDOT modified by Prussian Blue analogues deposited onto titania nanotubes – Their highly improved capacitance
PublicationIn this work we present the outstanding energy storage of prepared inorganic-organic heterojunction where hydrogenated ordered titania nanotubes (H-TiO2NT) were modified by the hybrid made of poly(3,4-ethylenedioxythiophene) (pEDOT) and iron hexacyanoferrate centres (Fehcf, Prussian Blue). The material TiO2NT/pEDOT:Fechf was obtained electrochemically by means of: anodization, hydrogenation and finally, electropolymerization of...
-
Electrochemical characterization of a composite comprising PEDOT/PSS and N doped TiO2 performed in aqueous and non-aqueous electrolytes
PublicationNitrogen doped titania (N-TiO2) was used as an inorganic component of composite electrodes containing poly(3,4-ethylenedioxythiophene) with poly(4-styrenesulphonate) PEDOT/PSS/N-TiO2. The composite materials were obtained by direct electrodeposition from an N-TiO2 suspension containing polyelectrolyte (NaPSS) and monomer EDOT. The electrodes were electrochemically tested in aqueous and non-aqueous electrolytes using cyclic voltammetry...
-
Distance measurement by the low coherent interferometer with NND layer (the source wavelegth 1310 nm)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Long-Period Gratings and Microcavity In-Line Mach Zehnder Interferometers as Highly Sensitive Optical Fiber Platforms for Bacteria Sensing
PublicationSelected optical fiber sensors offer extraordinary sensitivity to changes in external refractive (RI), which make them promising for label-free biosensing. In this work the most sensitive ones, namely long-period gratings working at (DTP-LPG) and micro-cavity in-line Mach-Zehnder interferometers (µIMZI) are discussed for application in bacteria sensing. We describe their working principles and RI sensitivity when operating in water...
-
Solid-Contact pH Sensor without CO2Interference with a Superhydrophobic PEDOT-C14as Solid Contact: The Ultimate “Water Layer” Test
Publication -
Interferometric optical fiber sensors with active stabilization of the operating point using a tunable semiconductor laser. Optical Fibres and Their Applications VIII.
PublicationW pracy przedstawiono wyniki badań światłowodowych interferometrycznych sensorów siły wykonanych w konfiguracji interferometru Michelsona i wykorzystujących aktywną stabilizację punktu pracy przy pomocy zmiany długości fali źródła. Porównano dwie klasy omawianych sensorów a następnie zrealizowano sensor. W konstrukcji sensora zastosowano modulator z pośrednim pomiarem siły. Mierzona siła jest zamieniana na ciśnienie hydrostatyczne,...
-
Monitoring the fracture process of concrete during splitting using integrated ultrasonic coda wave interferometry, digital image correlation and X-ray micro-computed tomography
PublicationThe paper deals with the continuous-time monitoring of mechanical degradation in concrete cubes under splitting. A series of experiments performed with integrated coda wave interferometry (CWI) and digital image correlation (DIC), supported with X-ray micro-computed tomography (micro-CT) is reported. DIC and micro-CT techniques were used to characterize the fracture process in detail. CWI method was proved to be effective in the...
-
Titania nanotubes infiltrated with conducting polymer PEDOT modified by Prussian Blue – a novel type of organic-inorganic heterojunction characterised with enhanced photoactivity.
PublicationA highly ordered p–n heterojunction was formed based on titania nanotubes containing a conducting polymer with Prussian blue matrix. The study demonstrates, for the first time, cases when a composite based on titania array scaffolding and Prussian blue embedded in PEDOT exhibits reversible FeII/FeIII redox activity. Highly enhanced photoactivity and capacitance of the obtained material are depicted in comparison to pristine titania....
-
Fabrication and photoactivity of organic-inorganic systems based on titania nanotubes and PEDOT containing redox centres formed by different Prussian Blue analogues
PublicationHerein, the heterojunction composed of an inorganic substrate: ordered hydrogenated titania nanotubes (H-TiO2NTs) and a deposited organic film: poly(3,4-ethylenedioxythiophene) (PEDOT) is reported. The conducting polymer is modified with different transition metal haxacyanoferrates (Mehcf), wherein as metal: copper, iron, cobalt and nickel are introduced. The presence of various metal centres provides characteristic redox activity...
-
Correction: Titania nanotubes infiltrated with the conducting polymer PEDOT modified by Prussian blue – a novel type of organic–inorganic heterojunction characterised with enhanced photoactivity
Publication -
Application of fiber optic sensors using Machine Learning algorithms for temperature measurement of lithium-ion batteries
PublicationOptical fiber sensorsusing low-coherence interferometry require processing ofthe output spectrum or interferogramto quickly and accurately determine the instantaneous value of the measured quantity, such as temperature.Methods based on machine learning are a good candidate for this application. The application of four such methods in an optical fiber temperature sensoris demonstrated.Using aZnO-coated...
-
Maximum Power Point Technique (MPPT) for PV System Based on Improved Pert and Observe (P&O) Method with PI Controller
PublicationPhotovoltaic power generation system has key rule in electricity production. Although, it is clean renewable energy with unlimited resources but it has some drawbacks in efficiency. In order to maximize the efficiency, PV array must drive at maximum power point. For the reason so, several algorithms are used in PV system to track MPP and reduce the...
-
The influence of polarization of titania nanotubes modified by a hybrid system made of a conducting polymer PEDOT and Prussian Blue redox network on the Raman spectroscopy response and photoelectrochemical properties
PublicationIn this work we show the impact of applied potential on network vibrations and photoelectrochemical properties of a composite material containing hydrogenated titania nanotubes and poly (3,4-ethylenedioxythiophene) with iron hexacyanoferrate (H-TiO2/pEDOT:Fehcf) acting as a redox centre. For this purpose, Raman spectroscopy measurements under the working electrode (WE) polarization were carried out, allowing investigation of changes...
-
Paweł Wierzba dr hab. inż.
PeopleDr Paweł Wierzba, E.E. M.Sc. E.E. received from WETI PG 1994 PhD in optoelectronics (with honours) from WETI PG 2001 Research Stays at VTT Technical Research Centre of Finland from 1997 to 2000 Finnish Academy Scholarship at VTT Technical Research Centre of Finland (12 months) 2002-3 Research interest area covers optical and optical fiber meaurement methods, technology of selected ceramic and liquid crystalline materials relevant...
-
Modyfikowane nanodiamentowe warstwy do sensorów z detekcją optyczną i elektrochemiczną
PublicationW rozprawie doktorskiej przedstawiono opracowanie parametrów procesów syntezy osadzania z fazy gazowej wspomaganego plazmą mikrofalową (MWPACVD) do wytwarzania warstw nanodiamentowych o niskim współczynniku absorpcji optycznej i wysokiej przewodności elektrycznej. Warstwy te są przeznaczone do sensorów z detekcją optyczną i elektrochemiczną stosowanych w układzie interferometru Mach-Zehndera do badania in situ modyfikacji elektrod...
-
Global Complex Roots and Poles Finding Algorithm in C × R Domain
PublicationAn algorithm to find the roots and poles of a complex function depending on two arguments (one complex and one real) is proposed. Such problems are common in many fields of science for instance in electromagnetism, acoustics, stability analyses, spectroscopy, optics, and elementary particle physics. The proposed technique belongs to the class of global algorithms, gives a full picture of solutions in a fixed region ⊂ C × R and...
-
Thermal Transitions and Structural Characteristics of Poly(3,4-ethylenedioxythiophene/cucurbit[7]uril) Polypseudorotaxane and Polyrotaxane Thin Films
PublicationHerein, we report the thermal transitions and structural properties of poly(3,4-ethylenedioxythiophene/cucurbit[7]uril) pseudopolyrotaxane (PEDOT∙CB7-PS) and polyrotaxane (PEDOT∙CB7-PR) thin films compared with those of pristine PEDOT. The structural characteristics were investigated by using variable-temperature spectroscopic ellipsometry (VTSE), differential scanning calorimetry (DSC), X-ray diffraction (XRD) and atomic force...
-
Organic-inorganic composites consisted of poly(3,4-ethylenedioxythiophene)and Prussian Blue analogues
PublicationThe organic-inorganic material consisted of poly(3,4-ethylenedioxythiophene) (pEDOT) and copper hexacyanoferrate (Cuhcf) was synthesized. The pEDOT film with Fe(CN)63−/4− as counter-ions potentiodynamically polarized in aqueous CuCl2 electrolyte brings about stable hybrid material (pEDOT/Cuhcf) performing single redox activity of FeII/III at a formal potential Ef = 0.61 V (vs. Ag/AgCl/0.1 M KCl) and less clearly shaped two redox...
-
Chapter 8. New composite materials for electrochemical capacitors
PublicationW pracy zaprezentowano materiały hybrydowe składające się z polimeru przewodzącego elektronowo połączonego z nieorganiczną siecią typu redoks. Te materiały to poli(3,4-etylenodioksytiofen) modyfikowany heksacyjanożelazianem (II/III) żelaza (pEDOT/Fehcf), kobaltu (pEDOT/Cohcf) i niklu (pEDOT/Nihcf).Materiały elektrodowe scharakteryzowano metodami elektrochemicznymi w elektrolitach niewodnych. Otrzymane materiały hybrydowe cechują...
-
Preparation and Characterization of Microsphere ZnO ALD Coating Dedicated for the Fiber-Optic Refractive Index Sensor
PublicationWe report the fabrication of a novel fiber-optic sensor device, based on the use of a microsphere conformally coated with a thin layer of zinc oxide (ZnO) by atomic layer deposition (ALD), and its use as a refractive index sensor. The microsphere was prepared on the tip of a single-mode optical fiber, on which a conformal ZnO thin film of 200 nm was deposited using an ALD process based on diethyl zinc (DEZ) and water at 100 °C....
-
Reliability and Validity of Optoelectronic Method for Biophotonical Measurements
PublicationReliability and validity of measurements is of utmost importance when assessing measuring capability of instruments developed for research. In order to perform an experiment which is legitimate, used instruments must be both reliable and valid. Reliability estimates the degree of precision of measurement, the extent to which a measurement is internally consistent. Validity is the usefulness of an instrument to perform accurate...
-
Graphene oxide, reduced graphene oxide and composite thin films NO2 sensing properties
PublicationA graphene oxide (GO), reduced graphene oxide (RGO) and poly(3,4-ethylenedioxytiophene)-reduced graphene oxide (PEDOT-RGO composite) gas sensors were successfully fabricated using an electrodeposition method. The electrodeposition was carried out in aqueous GO dispersions. To obtain RGO and PEDOT-RGO, the electrochemical reduction of GO and PEDOT-GO was carried out in 0.1 M KCl at a constant potential of −0.85 V. The GO, RGO and PEDOT-RGO...
-
Graphene oxide, reduced graphene oxide and composite thin films NO2 sensing properties
PublicationA graphene oxide (GO), reduced graphene oxide (RGO) and poly(3,4-ethylenedioxytiophene)- reduced graphene oxide (PEDOT-RGO composite) gas sensors were successfully fabricated using an electrodeposition method. The electrodeposition was carried out in aqueous GO dispersions. In order to obtain RGO and PEDOT-RGO, the electrochemical reduction of GO and PEDOT-GO was carried out in 0.1 M KCl at constant potential of −0.85 V. The GO, RGO...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Gas sensors based on conducting polymers-recent developments
PublicationThis work discusses sensing performance dependence of PEDOT polymer and its composites on the counter ions used in the polymerization process. The sensors based on PEDOT-RGO composite show reversible response to NO2, while on PEDOT/LiClO4 irreversible. As a result, PEDOT-RGO could be used as a typical gas sensor, while sensor based PEDOT/LiClO4 could be used as an integrating gas sensor, also known as an accumulating gas sensor....
-
Conducting Polymer Microelectrodes Anchored to Hydrogel Films
PublicationArtykuł prezentuje wytwarzanie organicznych hydrożeli z mikroelektrodami poli(3,4-ethylenedioxythiophene, PEDOT), które wykazują obniżoną rezystywność 100 Ω/□. Proces przygotowania rozpoczyna się elektroosadzania przewodzącego PEDOT (ok. 20 S/cm) na mikroelektrodach Pt. Elektrolityczne wiąże się film PEDOT z hydrożelem. Tak wytworzona struktura jest odrywana elektrycznie pd podłoża.
-
Aleksandra Parteka dr hab. inż.
PeopleAbout me: I am an associate professor and head of doctoral studies at the Faculty of Management and Economics, Gdansk University of Technology (GdanskTech, Poland). I got my MSc degree in Economics from Gdansk University of Technology (2003) and Universita’ Politecnica delle Marche (2005), as well as MA degree in Contemporary European Studies from Sussex University (2006, with distinction). I received my PhD in Economics...
-
Capacitance Enhancement by Incorporation of Functionalised Carbon Nanotubes into Poly(3,4-Ethylenedioxythiophene)/Graphene Oxide Composites
PublicationThis paper reports on the role of oxidised carbon nanotubes (oxMWCNTs) present in poly-3,4-ethylenedioxytiophene (PEDOT)/graphene oxide (GOx) composite. The final ternary composites (pEDOT/GOx/oxMWCNTs) are synthesised by an electrodeposition process from the suspension-containing monomer, oxidised carbon nanotubes and graphene oxide. Dissociated functional groups on the surface of graphene oxide play a role of counter-ions for the...
-
High-Resolution, Broad-Range Detection Setup for Polarimetric Optical Fiber Sensors
PublicationA common-path polarization interferometer using a Wollaston prism and an area detector for the measurement of retardation or optical path difference is presented. Employing a moderate-resolution 1280 by 1024 pixel monochrome camera, it offers a measurement range of approximately 780 radians at 830 nm and 1350 radians at 515 nm while maintaining a high measurement resolution. Retardation introduced by a zero-order waveplate or a...
-
Low-coherence method of hematocrit measurement
PublicationDuring the last thirty years low-coherence measurement methods have gained popularity because of their unique advantages. Low-coherence interferometry, low-coherence reflectometry and low-coherence optical tomography offer resolution and dynamic range of measurement at the range of classical optical techniques. Moreover, they enable measurements of the absolute value of the optical path differences, which is still an unsolved problem...
-
In-situ optical diagnostics of boron-doped diamond films growth
PublicationInterferometry is a desirable method for in-situ measurement of thin, dielectric film growth, as it don't modify conditions of film deposition. Here we present interferometrical measurements of thickness of doped diamond films during Chemical Vapor Deposition (CVD) process. For this purpose we used a semiconductor laser with a 405nm wavelength. Additional ex-situ measurement using spectral interferometry and ellipsometry...
-
Poly(3,4-ethynenedioxythiophene)-Prussian Blue hybrid material evidence of direct chemical interaction betwenn PB andpEDOT
PublicationPrzedstawiono syntezę materiału złożonego z poli(3,4-etylenodioksytiofenu) oraz analogu błękitu pruskiego. Sieć struktury BP utworzona została wewnątrz matrycy polimerowej pEDOT-u za pomocą metody polaryzacji multicyklicznej. Chemiczne oddziaływania Fe z BP oraz siarki z pEDOT zostały potwierdzone metodą XPS. Obecność BP potwierdzono FTiR - stwierdzono obecność drgań rozciągających Fe-C oraz Fe-N. Metoda cyklowoltamperometryczna...
-
Optical Investigation of Hematocrit Level in Human Blood
PublicationW artykule przedstawiono możliwości wykorzystania metod optoelektronicznych, takich jak: spektroskopia Ramana i interferometria niskokoherencyjna do pomiaru poziomu hematokrytu ludzkiej krwi.
-
Emulsion cleaning of metal surfaces contaminated with fresh and oxidized printing ink.
PublicationWykonano badania usuwania farby drukarskiej, stosowanej do druku offsetowego za pomocą emulsji terpentyny i hexanu w wodzie.
-
Badania naprężeń własnych laserowo przetapianej stali X20Cr13 pod wpływem kawitacji.
PublicationPraca prezentuje badania wpływu obciążeń kawitacyjnych przetapianej laserowo stali X20Cr13 na wielkość naprężeń własnych. Do wyznaczania wielkości naprężeń własnych zastosowano metodę zautomatyzowanej interferometrii siatkowej.
-
Hybrid electrodes composed of electroactive polymer and metal hexacyanoferrates in non-aqueous electrolytes
PublicationMateriały hybrydowe złożone z polimeru elektroaktywnego poli(3,4-etylenodioksytiofenu) (pEDOT) i heksacyjanożelazianów wybranych metali Mehcf (Me = Fe, Co, Ni) zostały poddane testom w elektrolitach niewodnych składających się z mieszaniny rozpuszczalników węglan etylenu (EC) : węglan propylenu (PC) w stosunku objętościowym 1:1 oraz wybranych soli: KPF6 i LiPF6. Właściwości elektrochemiczne materiałów badane były metodami woltamperometrii...
-
Theoretical and experimental investigation of Optical Coherent Tomography topologies
PublicationW artykule przedstawiono teoretyczną i eksperymentalną analizę konfiguracji interferometrów w układach koherentnego tomografu optycznego. Zaprezentowano zrealizowany układ, którego specjalnie zaprojektowana konfiguracja pozawala na analizę zmian polaryzacji sygnału pomiarowego.
-
Eine Eeue Technik zur Präzisen Rissfortschrittsmessung im DCB oder im Keilversuch = A novel technique for precise crack length measurement in the DCB or wedge test
PublicationDiverse methods have been tried to study crack length, most basic relying on direct, or microscopic, observation of the crack tip position. Optical correlation, both lasermoiré and speckle interferometry, a single strain gauge and displacement sensorshave also been employed. Crack length measurement is, however, delicate. We present a novel method making use of strain gauges attached to one of the adherends.
-
Emulsion cleaning of metal surfaces contaminated with fresh and oxidizedprinting ink
PublicationWykonano badania usuwania farby drukarskiej, stosowanej do druku offsetowego, za pomocą emulsji terpentyny i hexanu w wodzie. Wyznaczono kinetykę procesu i wytypowano najkorzystniejszy skład emulsji.
-
Organic-inorganic materials for fast charging-discharging processes in energy storage devices
PublicationPraca dotyczy materiału kompozytowego złożonego z poli(3,4-etylenodioksytiofenu) i heksacyjanokobaltanu żelaza. Materiał został otrzymany elektrochemicznie bezpośrednio na elektrodzie tytanowej metodą jednoetapowa z zawiesiny zawierającej monomer (EDOT) oraz Fe3[Co(CN)6]2 w postaci proszku. Warstwy pEDOT/FehcCo otrzymane potencjostatycznie ładunkiem od 0,6 do 1,5 C/cm2 charakteryzują się różną grubością (od 1,9 do 4 μm) zależną...
-
Zastosowanie elementów optyki zintegrowanej wykonanych w technice zol-żel w biochemicznych sensorach światłowodowych.
PublicationW pracy przedstawiono zasadę działania światłowodowych sensorów biochemicznych wykorzystujących interferometrię polaryzacyjną. Zaproponowano wykorzystanie materiałów hybrydowych wykonanych w technologii zol-żel w konstrukcji jednorazowych przetworników pomiarowych. Omówiono technologię wytwarzania tych materiałów i wybrane zastosowania tych sensorów.
-
1D portable optical coherence tomography system
Publication—Imaging methods are an expanding branch of technology, which involves data acquisition and analysis of images for research and diagnostics. This paper has been devoted to the description of the optical design for a one-dimensional, portable optical coherence tomography (OCT) system. The Mach-Zehnder interferometer has been designed in the presented study. The description of the construction and applied hardware solutions have...
-
Rola i znaczenie architektury przemysłowej w krajobrazie kulturowym miasta
PublicationArtykuł dotyczy zagadnień krajobrazu miejskiego i jego specyfiki w odniesieniu do architektury przemysłowej. Szczególną uwagę poświęcono w nim kwestiom historycznych założeń architektoniocznych i urbanistycznych dawnych fabryk i zespołów produkcyjnych, ich obecnego oraz przyszłego wpływu na architekturę miasta.
-
Dependence of biological sensing on temperature based on investigation of SARS-CoV-2
Open Research DataPresented dataset is the result of an investigation of the attachment of SARS-CoV-2 specific IgG in the temepratures relevant in biology. The samples were measured during a period of 15 minutes, at 5°C, 25°C and 55°C. The measurements were performed using the microspher-based fiber-optic sensor, as an interferometer. The broadband optical light source...
-
Electrochemical synthesis and characterization of nanocomposites based on poly(3,4-ethylenedioxythiophene) and functionalized carbon nanotubes
PublicationThis work is focused on new composite materials consisting of poly(3,4-ethylenedioxythiophene) (pEDOT) and functionalized multi-walled carbon nanotubes synthesized electrochemically. Three types of composites were synthesized: the first one containing carbon nanotubes with carboxyl groups (covalent functionalization), the second one containing oxidized carbon nanotubes ox-MWCNTs (with different oxygen-rich polar groups) (covalent...
-
Impedance spectroscopy studies on hybrid materials consisting of poly(3,4-ethylenedioxythiophene) and iron, cobalt and nickel hexacyanoferrate
PublicationBadania warstw polimeru pEDOT modyfikowanego heksacyjanożelazianami żelaza, kobaltu i niklu przeprowadzono za pomocą spektroskopii impedancyjnej (SI). Wykazano, że materiały hybrydowe charakteryzują się dobrą stabilnością. Warstwy testowano w zakresie temperatur od 283 do 313K. w kontakcie z wodnym roztworem KCl. Wysokie współczynniki dyfuzji wskazują na możliwości wykorzystania układów jako przewodników jonowych.