Filters
total: 800
-
Catalog
Search results for: TI CAVITIES
-
Hydroxyapatite coatings on porous ti and ti alloys
PublicationDeposition of hydroxyapatite coating on porous Ti and Ti alloys with electrochemical and biomimetic deposition approach is presented. The enhancement of phosphates deposition by well oriented and uniform titanium oxide nanotube array on the surface of titanium substrate is discussed.
-
Self-Organized Nanotubular Oxide Layers on Ti and Ti Alloys
PublicationTo improve bioactivity of titanium and titanium, the implant surface modification by formation of self-organized TiO2 nanotube arrays with electrochemical techniques is presented. The influence of electrolyte composition and deposition parameters during anodization is characterized. The enhancement of phosphates deposition by titanium nanotubular structure is discussed. The calcium phosphate ceramics is shown to be uniformly deposited...
-
Optimization of Self-Organized TiO2 Nanotube Geometry on Ti and Ti Alloys Using Fuzzy Logic Reasoning
PublicationThe geometry of self-organized TiO2 nanotubes, obtained by electrochemicalanodization, has been determined by using fuzzy reasoning approach. The efficiency of TiO2nanotubular layer in biomedical applications depends on geometry and available surface area ofnanotubes, which can be determined by their diameter and length. The structure of nanotubesdepends on processing parameters of electrochemical anodization, like applied potential,anodization...
-
Surface modifications of ti and its alloys
PublicationThis article reviews the various surface modification techniques pertaining to titanium and titanium alloys including physical treatment, mechanical treatment, and chemical and electrochemical treatment. The proper surface modification expands the use of titanium and its alloys in the biomedical field for long-term implants retaining the excellent properties of substrate material and improving the specific surface properties required...
-
Structure and properties of the Ti+Ti(C,N) coatings obtained in the PVD process on sintered high speed steel
Publication -
An approach for evaluating trust in it infrastructures
PublicationW artykule zademonstrowano metodę oceny poziomu zaufania do systemu TI w oparciu o podejście funkcji przekonania.
-
Nonreciprocal cavities and the time-bandwidth limit: comment
PublicationIn their paper in Optica 6, 104 (2019), Mann et al. claim that linear, time-invariant nonreciprocal structures cannot overcome the time-bandwidth limit and do not exhibit an advantage over their reciprocal counterparts, specifically with regard to their time-bandwidth performance. In this Comment, we argue that these conclusions are unfounded. On the basis of both rigorous full-wave simulations and insightful physical justifications,...
-
Decomposing Cavities in Digital Volumes into Products of Cycles
Publication -
New laser-enhanced surface treatment of Ti bioalloy
PublicationPrzedstawiono wyniki badan mikrostruktury i korozji w roztworze Ringera stopu Ti6Al4V, który był poddawany nadtapianiu laserem CO2 w powietrzu, wodzie i ciekłym azocie. Stwierdzono znaczący wpływ warunków obróbki na mikrostrukturę, mikrotwardość i głębokość zmodyfikowanej warstwy wierzchniej.
-
CITIES
Journals -
Mechanical Properties and Residual Stress Measurements of Grade IV Titanium and Ti-6Al-4V and Ti-13Nb-13Zr Titanium Alloys after Laser Treatment
PublicationNowadays, surface engineering focuses on research into materials for medical applications. Titanium and its alloys are prominent, especially Ti-6Al-4V and Ti-13Nb-13Zr. Samples made of pure grade IV titanium and the titanium alloys Ti-6Al-4V and Ti-13Nb-13Zr were modified via laser treatment with laser beam frequency f = 25 Hz and laser beam power P = 1000 W during a laser pulse with duration t = 1 ms. Subsequently, to analyze...
-
Light-improved glucose sensing on ordered Au-Ti heterostructure
PublicationNon-enzymatic electrochemical platforms sensitive towards glucose presence have attracted a worldwide attention during last decades. We report on influence of solar light onto response of gold-titanium heterostructures prepared via controllable approach. The material based on Au nanoparticles orderly distributed over the structured titanium foil was obtained by electrochemical anodization followed by chemical etching, magnetron...
-
Low-temperature spectroscopic and scintillation characterisation of Ti-doped Al2O3
Publication -
Effects of Sr/Ti stoichiometry in SrTiO3-based SOFC anodes
PublicationScharakteryzowano wpływ stechiometrii Sr/Ti na właściwości strukturalne, elektryczne i mechaniczne anod na bazie tytanianu strontu. Wyjaśniono genezę niektórych zjawisk w oparciu o chemię defektów związków niestechiometrycznych na bazie istniejących pozycji literaturowych.
-
Surface cracking of laser melted Ti-6Al-4V alloy
PublicationOpisano charakterystyczne cechy pękania powierzchniowego obserwowanego po nadtapianiu laserem CO2 i Nd:YAG stopu Ti-6Al-4V. Obserwowano pęknięcia niezależnie od sposobu nadtapiania, penetrujące głęboko strefę przetopioną i w niewielkim stopniu zależne od sposobu nadtapiania. Przypisano obserwowane zjawisko przemianie martenzytycznej i (lub) naprężeniom cieplnym powstającym podczas gwałtownego chłodzenia.
-
Environmental degradation of Ti alloys in artificial saliva and a role of fluorides
PublicationThe titanium and its alloys are potentially prone to hydrogen embrittlement, including those proposed for dental implants. The research has been aimed to assess a susceptibility to environment-enhanced degradation of the Ti-13Zr-13Nb alloy in artificial saliva with or without hydrofluoric acid, subject or not to cathodic polarisation. The results have shown that even if artificial saliva is safe environment, both cathodic polarization...
-
STRUKTURA I TRANSPORT ELEKTRYCZNY UKŁADU Li-Ti-O
PublicationTytanian litu Li1+xTi2-xO4 (0 ≤ x ≤ 1/3) jest tlenkiem, który dzięki swym unikalnym właściwościom od połowy lat 70 pozostaje źródłem zainteresowania i obiektem badań naukowców. Jedną z najciekawszych właściwości tego związku jest przejście w stan nadprzewodzący poniżej temperatury około 13 K i jej silna zależność od stechiometrii układu. Oprócz nadprzewodnictwa wyróżniają go ciekawe właściwości elektrochemiczne oraz fotokatalityczne,...
-
Selective Laser Melting of Ti Alloy for Manufacturing The Prosthetic Elements
PublicationThe selective laser melting (SLM) is the additive manufacturing method of custom-designed parts. The used materials and the applications are various, including medicine. The titanium and its alloys are materials for which the dimensional quality, surface smoothness and no or extremely low porosity are difficult to reach. In this paper, the successful attempt to obtain by SLM the individually designed prosthetic bridges is described....
-
Smart Cities
Journals -
Cities and Health
Journals -
Theory versus experiment for vacuum Rabi oscillations in lossy cavities
PublicationThe 1996 experiment by Brune et al. [Phys. Rev. Lett. 76, 1800 (1996)] on vacuum Rabi oscillation is analyzed by means of alternative models of atom-reservoir interaction. Agreement with experimental Rabi oscillation data can be obtained if one defines jump operators in the dressed-state basis and takes into account thermal fluctuations between dressed states belonging to the same manifold. Such low-frequency transitions could...
-
Comparison of Properties of the Hybrid and Bilayer MWCNTs—Hydroxyapatite Coatings on Ti Alloy
PublicationCarbon nanotubes are proposed for reinforcement of the hydroxyapatite coatings to improve their adhesion, resistance to mechanical loads, biocompatibility, bioactivity, corrosion resistance, and antibacterial protection. So far, research has shown that all these properties are highly susceptible to the composition and microstructure of coatings. The present research is aimed at studies of multi-wall carbon nanotubes in three different...
-
Optimal Features of Porosity of Ti Alloys Considering their Bioactivity and Mechanical Properties
PublicationW artykule przedstawiono wpływ porowatości i rozmiaru porów tytanu i jego stopów, użytych, jako materiały ortopedyczne, na bioaktywność i własności mechaniczne struktur porowatych. Optymalne cechy porowatych rusztowań tytanowych umożliwiają rekonstrukcję i regenerację tkanki kostnej w zastosowaniach przenoszących obciażenie.
-
Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublicationAbstrakt artykułu pt. ''Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity''. The paper describes techniques to improve the bioactivity of titanium and ehnahnce the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotubular oxide layer.
-
Porous Selective Laser Melted Ti and Ti6Al4V Materials for Medical Applications
Publication -
Nanotubular oxide layers and hydroxyapatite coatings on ‘Ti–13Zr–13Nb’ alloy
PublicationThe presented research was aimed to determine the mechanical properties of the nanotubular oxide layer covered with hydroxyapatite coating. The Ti–13Zr–13Nb alloy was oxidised in 1M phosphoric acid with an addition of 0?5% HF for HF solution at 20 V voltage. The electrochemically assisted deposition of hydroxyapatite was performed at cyclic polarisation in NH4H2PO4 and CaCl2 solution at 80uC. The mechanical properties were determined...
-
Influence of microstructure on properties of 18Cr-10Ni-Ti stainless steel products.
PublicationBadano wpływ mikrostruktury na właściwości mechaniczne i odporność korozyjną wyrobów ze stali austenitycznej 18Cr-10Ni-Ti po przesycaniu z temperatury 1050 C. Wykazano, że węgliki TiC w ziarnach i na granicach ziaren/bliźniaków powodują znaczne obniżenie wydłużenia stali. Węgliki TiC na granicach ziaren/bliźniaków obniżają odporność na korozję międzykrystaliczną i sprzyjają powstawaniu uszkodzeń korozyjnych podczas hutniczej operacji...
-
XPS measurement of the Fe-Ti based materials
Open Research DataThe mono‐ and bimetal‐modified (Pd, Cu) titanium(IV) oxide and iron oxide (III) photocatalysts were prepared by chemical reduction method and characterized using XPS method. The composition of elements incorporated in the surface layer of mono- and bimetallic photocatalysts was determined by XPS analysis, as well as the valence state of elements. Measurements...
-
SEM micrographs of Ti tooth implant corrosion
Open Research DataThe dataset contains micrographs made with a scanning electron microscope (SEM) Hitachi S-3400N of the tooth implant removed after inflammation. The inflammation was induced by the increased corrosion rate of the titanium screw. The reason for the corrosion to occur was the appearance of the concentration cell of different aeration for various areas...
-
Thermoluminescence kinetics of undoped and doped (Ti, Cu, Ce) lithium aluminate crystals
Publication -
Radio-photoluminescence of highly irradiated Lif:Mg,Ti and Lif:Mg,Cu,P detectors
Publication -
Sliding Wear Performance of AlCrN Coating on TiB2/Ti Composites at High Temperatures
Publication -
The possibility of an use of laser treatment to improve the behaviour of the Ti-6Al-4V alloy
PublicationPrezentowana praca miała na celu stworzenie warunków ultraszybkiego chłodzenia przetopionej warstwy w obecności azotu tak, aby otrzymać twardą i gruba warstwę wierzchnią na stopie Ti-6Al-4V , najczęściej używanm stopie Ti, zawierającą struktury martenzytu i azotku tytanu.
-
The phase composition of the surface layer of laser melted Ti-6Al-4V bioalloy
PublicationZastosowanie metody obróbki laserowej stopów Ti zwiekszyły twardość i odporność stopu na korozję. Jednakże uzyskane warstwy były stosunkowo cieńkie. W pracy zastosowano laser o dużej mocy dla stopu schłodzonego w ciekłym azocie, aby uzyskać grubszą warstwę, która w strefie zewnętrznej złożona będzie z tlenku i azotku tytanu, ważnych faz w biostopach.
-
Porowate nanostruktury anatazu wytwarzane z Ti oraz TiO2 metodą PLD
PublicationNiniejsza praca dotyczy wytwarzania cienkich warstw dwutlenku tytanu metodą PLD. Za pomocą technik spektroskopowych zbadany został wpływ wartości ciśnienia gazu osłonowego na otrzymywane struktury krystaliczne w warstwach. Obserwowano także zależność uzyskanych faz krystalicznych od rodzaju odparowywanego materiału.
-
Cyclic behaviour modelling of additively manufactured Ti-6Al-4V lattice structures
PublicationThe present work is concerned with the numerical modelling of the cyclic behaviour of Ti-6Al-4V lattice structures. In the study, diamond structures of titanium alloy produced by the additive laser powder bed fusion (LPBF) method with different degrees of relative density were used. Realistic geometric models of the studied mesostructures were generated using computed microtomography, taking into account the imperfections of the...
-
Influence of Laser Treatment on Microstructure of Surface Layer of the Ti-6Al-4V Alloy
PublicationPrzedstawiono mikrostrukturę powierzchni, przekroju i przełomu warstwy wierzchniej stopu Ti-6Al-4V uzyskanej po nadtapianiu laserem w różnym środowisku. Stwierdzono wzrost mikrotwardości stopu w warstwie nadtopionej, rozdrobnienie ziarna, a także tworzenie azotków tytanu i mikropęknięć skutkiem obecności znacznych naprężeń własnych. Grubość wytworzonych warstw osiągała wartość 1,5 mm.
-
Evaluation of Wear Resistance of Ti alloys used for elements friction of knee endoprosthesis
PublicationThe paper presents research results of resistance to abrasive wear of titanium alloys: Ti6Al4V (commonly used) and Til3Nb13Zr (alloy of new generation) in association with polyethylene (UHMW-PE) predisposed for elements on pair of the knee endoprosthesis. The results were analysed from the point of possibility of an use of new generation titanium alloys as components of such implants. The tests of resistance to abrasive wear of...
-
Synthesis and properties of HoT2Al20 (T = Ti, V, Cr) intermetallic cage compounds
PublicationPolycrystalline samples of HoT2Al20 (T = Ti, V, Cr) intermetallics were synthesized using a step-wise arc-melting technique. All three compounds adopt the CeCr2Al20-type crystal structure with Ho atoms positioned inside oversized icosahedral cages formed by Al atoms. The structure of HoV2Al20 compound is reported. The materials properties were studied by means of electrical resistivity, magnetic susceptibility, and specific heat...
-
Nanostructuring of thin Au films deposited on ordered Ti templates for applications in SERS
PublicationIn this work the results on thermal nanostructuring of the Au films on Ti templates as well as morphology and optical properties of the obtained structures are reported. The bimetal nanostructures are fabricated in a multi-step process. First, the titania nanotubes are produced on the surface of Ti foil by anodization in an ethylene glycol-water solution containing fluoride ions. This is followed by chemical etching in oxalic acid...
-
Prosthetic Elements Made of the Ti-13Zr-13Nb Alloy by Selective Laser Melting
PublicationThe fabrication of the prosthetic foundations and bridges from the Ti-13Zr-13Nb alloy is described. The process was started from CAD/CAM design of 3D models of the foundations based on scanning of patient`s mouth. Next, 3D models were transformed into *.stl files for the manufacturing stage and then the manufacturing process by means of the selective laser melting with the SLM Realizer 100 equipment was made. The intrinsic structure...
-
Ti-Fe2O3/In2O3 as photoactive material: The role of the substrate in photoelectrochemical water oxidation
PublicationThe layers of Ti-Fe2O3/In2O3 were prepared on the different substrates using hydrothermal method: Ti/TiO2 nanotubes, Ti foil, FTO and FTO/TiO2. Materials were characterized using scanning electron microscopy, XRD, Raman, UV-Vis, and X-ray photoelectron spectroscopy and tested as photoanodes for water oxidation under illumination. The formation of heterojunction on the TiO2 nanotubes increases photocurrent of water oxidation at...
-
Mechanical Behavior of Bi-Layer and Dispersion Coatings Composed of Several Nanostructures on Ti Substrate
PublicationThree coatings suitable for biomedical applications, including the dispersion coating composed of multi-wall carbon nanotubes (MWCNTs), MWCNTs/TiO2 bi-layer coating, and MWCNTs-Cu dispersion coating, were fabricated by electrophoretic deposition (EPD) on Ti Grade II substrate. Optical microscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy, and nanoindentation were applied to study topography, chemical, and...
-
Influence of Two-Stage Anodization on Properties of the Oxide Coatings on the Ti–13Nb–13Zr Alloy
PublicationThe increasing demand for titanium and its alloys used for implants results in need of such innovative surface treatment that may jointly increase corrosion resistance and biocompatibility, and demonstrate antibacterial protection at no cytotoxicity. The purpose of this research was to characterize the effect of two-stage anodization, performed for 30 min in phosphoric acid, at the presence of hydrofluoric acid in the second stage....
-
Nanoindentation tests titanium alloy Ti-6Al-4V after interference laser treatment
PublicationThe study aimed was to assess selected mechanical properties of surface layers obtained after interference laser treatment – DLIL of titanium alloy Ti-6Al-4V used for implants. The samples were melted in still air at room temperature, for this purpose Nd:YAG laser was used, the number of laser shots was variable. Next, nanoindentation tests were performed, based on which Young’s modulus and nanohardness in the obtained surface...
-
Laser-assisted approach for improved performance of Au-Ti based glucose sensing electrodes
PublicationThis paper focuses on the synthesis route and electrochemical properties of electrocatalytic material based on gold nanoparticles (NPs) embedded in a structured titanium template obtained via optimized anodization, chemical etching and laser processing. SEM inspection reveals the presence of Au NPs (60–90 nm in diameter) sited in the titanium foil cavities. Performed electrochemical measurements enable nomination of the set of working...
-
Investigation of machinability of Ti–B-SiCp reinforced Cu hybrid composites in dry turning
Publication -
Evaluation of the Microstructure and Magnetic Properties of Fe73Me5Y3B19 (Where Me = Ti or Nb) Amorphous Alloys
Publication -
Structural and electrical properties of Sr(Ti,Fe)O3-δ materials for SOFC cathodes
PublicationW niniejszym artykule, dwa związki SrTiO3 domieszkowanego Fe przebadano pod względem przydatności na katody w tlenkowych ogniwach paliwowych. SrTi0.65Fe0.35O3 i SrTi0.5Fe0.5O3 zostały przebadane pod względem reaktywności chemicznej z elektrolitem YSZ. Stwierdzono, że przewodnictwo elektryczne tych związków jest stosunkowo niskie: 0,4 S/cm i 2 S/cm odpowiednio dla STF35 i STF50.
-
Powder metallurgy of the porous Ti-13Nb-13Zr alloy of different powder grain size
PublicationThe objective of the present project was to determine the effects of powder granulation (fraction of grain size) for the Ti-13Nb-13Zr alloy, produced by powder metallurgy, on its porosity, grain cohesion, compressive strength, and Young`s modulus. Two powder fractions, 45–105 µm, and 106–250 µm were applied. The 50 mass pct of NH4HCO3 was added as a space holder. The specimens were in compaction stage uniaxially pressed at pressure...
-
Wpływ nadtapiania laserowego w warunkach kriogenicznych na strukturę warstwy wierzchniej stopu Ti-6Al-4V = Effect of laser melting at cryogenic conditions on structure of the surface layer of the Ti-6Al-4V alloy
PublicationWykonano nadtapianie laserowe stopu Ti-6Al-4V zanurzonego w środowisku ciekłego azotu. Badania mikroskopowe wykazały znaczący wpływ parametrów nadtapiania na grubość, mikrostrukturę i mikrotwardośc warstwy wierzchniej.
-
Sustainable Cities and Society
Journals -
Frontiers in Sustainable Cities
Journals -
IET Smart Cities
Journals -
Future Cities and Environment
Journals -
A Flexible Nafion Coated Enzyme‐free Glucose Sensor Based on Au‐dimpled Ti Structures
PublicationThe detection of glucose at low concentrations using electrochemical sensors is of great importance due to the possibility of using different human body fluids than blood, such as e.g. urine, saliva, sweat or tears. The interest behind those biofluids is related to their utility in non-invasive sugar determination. In this work, we present flexible, fully biocompatible electrode material based on Au nanoparticles immobilized onto...
-
Fluorine ions in photocatalysts’ synthesis: an obstacle or an ally? The investigation of photocatalysts in Ti-O-F system
PublicationTitanium(IV) oxide (TiO2) is one of the most promising photocatalysts, which is expected to be applied in the photocatalytic degradation of xenobiotics. For sustainable development and green chemistry approach recently, much effort has been paid to enhance TiO2 photocatalytic activity in UV-vis light by modifying its structure. The photocatalytic process’s complexity cannot be simply described as electron-hole pairs generations...
-
Manipulating Electrical Properties of Nanopatterned Double-Barrier Schottky Junctions in Ti/TiOx/Fe Systems
Publication -
The isomerization of α-pinene over the Ti-SBA-15 catalyst—the influence of catalyst content and temperature
Publication -
Influence of the Titanium Content in the Ti-MCM-41 Catalyst on the Course of the α-Pinene Isomerization Process
Publication -
Rozwój materiałów tytanowych na implanty aloplastyczne = Development of Ti-based materials for alloplastic implants
PublicationThe article is aimed at demonstraiting the previous results and current research work in the area made by Advanced Biomaterials Research Group at the Faculty of Mechanical Engineering. The paper concentrated on the developement of Ti-based biomaterials with improved biocompatibility and bioactivity.
-
Improvement of machinability of Ti and its alloys using cooling-lubrication techniques: a review and future prospect
Publication -
Growth and properties of Ti-Cu films with respect to plasma parameters in dual-magnetron sputtering discharges
Publication -
Crystal structure and physical properties of Mg6Cu16Si7-typeM6Ni16Si7, for M = Mg, Sc, Ti, Nb, and Ta
PublicationW pracy dyskutowana jest synteza i struktura krystalograficzna, określona poprzez proszkową dyfrakcję rentgenowską, dla pięciu związków M6Ni16Si7, gdzie M = Mg, Sc, Ti, Nb, and Ta. Wszystkie te związki krystalizują w strukturze typu Mg6Cu16Si7.
-
Proton-Electron Hole Interactions in Sr(Ti,Fe)O3−δ Mixed-Conducting Perovskites
PublicationOxides in which total electrical conductivity is determined by the partial conductivities of three types of charge carriers i.e. holes/ electrons, oxygen ions, and protons are key components of well-functioning proton ceramic fuel cells. Apart from electrochemical properties also easily modified microstructure is an important feature of the electrodes. In the paper, a group of SrTi1−xFexO3−δ (STF, x = 0.2–0.8) perovskites prepared...
-
THE USE OF THE Ti-13Zr-13Nb ALLOY POWDER FOR MANUFACTURING OF PROSTHETIC PARTS BY SELECTIVE LASER MELTING
PublicationThe 3D printing is a manufacturing technique belonging to the additive methods able to prepare the designed parts for various purposes. The present reasearch was aimed to fabricate the prosthetic foundations and bridges made of the new Ti-13Zr-13Nb alloy by the selective laser melting (SLM) of a metal powder. The scanning electron examinations and micro scanning tomography were used to investigate the surface quality and intrinsic...
-
Smart Blue Cities
PublicationThis paper presents the concept of Smart Cities from the perspective of those located by water, considering if there are more major differences in the way the concept is implemented in coastal cities, as opposed to those located anywhere else. It proves possible to point to such differences, in relation to the three key areas of mobility, the environment and living. Further consideration is given to specific legal and cross-cultural...
-
Injectable Platelet-Rich Fibrin (I-PRF) Administered to Temporomandibular Joint Cavities: A Scoping Review
Publication -
Yield surface identification of CP-Ti and its evolution reflecting pre-deformation under complex loading
Publication -
Core/shell structured Ti/Si/C composite for high-performance zinc-ion hybrid capacitor
Publication -
Tailoring the Stability of Ti-Doped Sr2Fe1.4TixMo0.6−xO6−δ Electrode Materials for Solid Oxide Fuel Cells
Publication -
Crystal structure and physical properties of Mg6Cu16Si7-type M6Ni16Si7, for M=Mg, Sc, Ti, Nb, and Ta
Publication -
Korozyjne pękanie naprężeniowe stali 18Cr-10Ni-Ti w systemie chłodzenia za wodorowym reaktorem.
PublicationPrzedstawiono mechanizm korozyjnego pękania napręzeniowego stali austenitycznej 18Cr-10Ni-Ti w systemie chłodzenia za reaktorem instalacji hydrorafinacji olejów przepracowanych.
-
Novel composite of Zn/Ti-layered double hydroxide coupled with MXene for the efficient photocatalytic degradation of pharmaceuticals
PublicationIn the present study, a hybrid photocatalyst of Zn/Ti layered double hydroxide (LDH) coupled with MXene – Ti3C2 was synthesized for the first time and applied in photocatalytic degradation of acetaminophen and ibuprofen, two commonly present in the natural environment and prone to accumulate in the aquatic ecosystem pharmaceuticals. The effect of MXene content (0.5 wt%, 2.5 wt%, and 5 wt%) on the photocatalytic activity of LDH/MXene...
-
Determinants of the surface quality, density and dimensional correctness in selective laser melting of the Ti-13Zr-13Nb alloy
PublicationSelective laser melting is widely used for custom-designed elements. Successful manufacturing depends on laser treatment parameters and material features. This research aimed to determine the effects of laser power, scan time and hatch distance on surface quality, relative density and dimensional precision for cuboids made of the Ti-13Zr-13Nb alloy. The influence of energy density, energy flux and pre-heating was seen to be decisive...
-
Theory versus experiment for vacuum Rabi oscillations in lossy cavities. II. Direct test of uniqueness of vacuum
PublicationThe paper continues the analysis of vacuum Rabi oscillations we started in part I [Phys. Rev. A 79, 033836 (2009)]. Here we concentrate on experimental consequences for cavity QED of two different classes of representations of harmonic-oscillator Lie algebras. The zero-temperature master equation, derived in part I for irreducible representations of the algebra, is reformulated in a reducible representation that models electromagnetic...
-
The Administration of Hyaluronic Acid into the Temporomandibular Joints’ Cavities Increases the Mandible’s Mobility: A Systematic Review and Meta-Analysis
Publication -
Metal (Mo, W, Ti) Carbide Catalysts: Synthesis and Application as Alternative Catalysts for Dry Reforming of Hydrocarbons—A Review
PublicationDry reforming of hydrocarbons (DRH) is a pro-environmental method for syngas production. It owes its pro-environmental character to the use of carbon dioxide, which is one of the main greenhouse gases. Currently used nickel catalysts on oxide supports suffer from rapid deactivation due to sintering of active metal particles or the deposition of carbon deposits blocking the flow of gases through the reaction tube. In this view,...
-
Experimental and theoretical investigation of the reactivity of [(BDI*)Ti(Cl){η2-P(SiMe3)-PiPr2}] towards selected ketones
PublicationIn this work, we report a new type of reactivity of [(BDI*)Ti(Cl){η2-P(SiMe3)-PiPr2}] (1) towards ketones (BDI* = 2,6-diisopropylphenyl-β-methyldiketiminate ligand). In the reaction of 1 with acetone, cyclopentanone or cyclohexanone, a ketone moiety is inserted into Ti–Pphosphanyl or Ti–Pphosphido bonds to form complexes with a new C–P–P moiety, providing [(BDI*)Ti(Cl){η2-P(SiMe3)-PiPr2-C(Me)2O}] (2a), [(BDI*)Ti(Cl){η2-OC(Me)2P(SiMe3)-PiPr2}]...
-
Epoxidation of natural limonene extracted from orange peels with hydrogen peroxide over Ti-MCM-41 catalyst
Publication -
Characterization and Wear Response of Magnetron Sputtered W–B and W–Ti–B Coatings on WC–Co Tools
Publication -
Adhesion of AlCrN coating deposited on TiB2/Ti composites sintered by SPS dedicated for high temperature tribological applications
Publication -
Ocena odporności na zużycie ścierne stopów Ti na elementy pary trącej endoprotez stawu kolanowego
PublicationNajczęściej stosowanym biomateriałem tytanowym na elementy endoprotez stawu kolanowego jest stop Ti6Al4V. Z uwagi na zawartość wanadu, zaliczanego do pierwiastków o dużej toksyczności podejmowane są działania w kierunku zastąpienia wskazanego stopu - stopami bezwanadowymi. Jednym z najbardziej obiecujących jest stop Ti13Nb13Zr zawierający w swoim składzie jedynie pierwiastki witalne, niewywołujące stanów zapalnych i odczynów...
-
Optimization of biocorrosion resistance and mechanical properties of PM Ti–XAl–2Fe–3Cu alloys by response surface methodology
PublicationIn the current study, the biocorrosion resistance and mechanical properties of the Ti–XAl–2Fe–3Cu (wt%) (X = 6, 4, 2 wt%) alloy produced by powder compact extrusion of blended elemental powders were optimized by using the response surface methodology in order to gain the best combination of processing parameters. To run the optimization process, central composite design with three equal levels of oxygen, hydrogen and aluminum was...
-
Effect of electron count and chemical complexity in the Ta-Nb-Hf-Zr-Ti high-entropy alloy superconductor
PublicationHigh-entropy alloys are made from random mixtures of principal elements on simple lattices, stabilized by a high mixing entropy. The recently discovered body-centered cubic (BCC) Ta-Nb-Hf-Zr-Ti high-entropy alloy superconductor appears to display properties of both simple crystalline intermetallics and amorphous materials; e.g., it has a well-defined superconducting transition along with an exceptional robustness against disorder....
-
Zbadanie właściwości strukturalnych i elektrycznych niestechiometrycznych, domieszkowanych związków typu Srx(Ti,Fe)O3-δ
PublicationNiniejsza rozprawa doktorska zatytułowana: „Zbadanie właściwości strukturalnych i elektrycznych niestechiometrycznych, domieszkowanych związków typu Srx(Ti,Fe)O3-δ” przedstawia wyniki badań właściwości fizykochemicznych domieszkowanego tytanianu strontu wykazującego mieszane przewodnictwo jonowo-elektronowe, w celu poszerzenia o nim wiedzy i określenia jego przydatności w urządzeniach elektrochemicznych. Przebadano szereg związków...
-
Synthesis and properties of porous Sr 0.96 Y 0.04 Ti 1−x Nb x O 3
PublicationA series of porous, single phase Sr0.96Y0.04Ti1-xNbxO3 samples was obtained using a wet synthesis method (modified citrate sol-gel) method. Temperature-programmed reduction (TPR) and temperature-programmed oxidation (TPO) measurements have shown high stability of the obtained material in variable (oxidizing/reducing) atmospheres. All samples exhibit high conductivity in hydrogen atmosphere with the highest value (around 1S/cm)...
-
Seismic Response Analysis of Knee-Braced Steel Frames Using Ni-Ti Shape Memory Alloys (SMAs)
PublicationShape Memory Alloys (SMAs) are known as active materials that can be widely used for structural purposes due to their flag-shape behavior under loading and reloading. Their unique characteristics provided a potential solution for civil engi-neers especially to model buildings with the capability of dissipating seismic en-ergy. In this study, the main purpose is to explore the seismic behavior of Knee-Braced Frames (KBFs) and...
-
Green, blue and energy in cities
PublicationThe article refers to the implementation of blue-green infrastructure in cities, with particular emphasis on the aspect of rainwater and energy management. The article presents the advantages of water and greenery in the city and gives examples of engineering solutions used, both the more popular (including green and biosolar roofs), as well as experimental solutions, which are an interesting and necessary alternative in the era...
-
Application of a hybrid finite difference-mode matching method to the analysis of circular cavities loaded with cylindrical metallic objects
PublicationW artykule przedstawiono badania rezonatorów cylindrycznych zawierających obiekty cylindryczne o dowolnym przekroju poprzecznym z wykorzystaniem metody hybrydowej stanowiącej połączenie metody różnic skończonych z metodą dopasowania rodzajów. W ramach badań określono częstotliwości rezonansowe dla wybranych struktur rezonatorów. Wyniki numeryczne zostały zweryfikowane eksperymentalnie.
-
<title>FPGA-based multichannel optical concentrator SIMCON 4.0 for TESLA cavities LLRF control system</title>
Publication -
Bandwidth-Controllable Third-Order Band Pass Filter Using Substrate Integrated Full- and Semi-Circular Cavities
PublicationThe article presents a novel circular substrate integrated waveguide (SIW) bandpass filter (BPF) with controllable bandwidth. The proposed BPF is configured using two microstrip feedlines, semi- circular SIW cavities, capacitive slots, and inductive vias. The circular cavity is bisected into two halves, with the two copies thereof being cascaded. Two bisected and cascaded structures obtained this way are subsequently connected...
-
Solvent Impact on the Diversity of Products in the Reaction of Lithium Diphenylphosphide and a Ti(III) Complex Supported by a tBu2P–P(SiMe3) Ligand
PublicationWe present two important trends in the reactivity ofthe titanium complex [MeNacNacTi(Cl){η2-P(SiMe3)-PtBu2}](MeNacNac− = [Ar]NC(Me)CHC(Me)N[Ar]; Ar = 2,6-iPr2Ph)with nucleophilic reagents RLi (R = Ph2P,tBuO, (Me3Si)2N, andtBu2N) depending on the reaction medium. Reaction in nonpolarsolvent (toluene) leads to three main products: via an autoredoxprocess and nucleophilic substitution at the Ti-atom to afford theTi(IV) complex [MeNacNacTi(R){η2-P-PtBu2}]...
-
Electrochemical glucose sensor based on the glucose oxidase entrapped in chitosan immobilized onto laser-processed Au-Ti electrode
PublicationThe study on novel electrode material composed of structured titanium foil with embedded Au nanoparticles and modified with chitosan with entrapped glucose oxidase is presented. To confirm the successful immobilization of glucose oxidase FT-IR analysis was performed. The response of electrodes were tested towards glucose in the presence of different interference compounds and biological fluids. The prepared material exhibits excellent...
-
Structural and Material Determinants Influencing the Behavior of Porous Ti and Its Alloys Made by Additive Manufacturing Techniques for Biomedical Applications
PublicationOne of the biggest challenges in tissue engineering is the manufacturing of porous structures that are customized in size and shape and that mimic natural bone structure. Additive manufacturing is known as a sufficient method to produce 3D porous structures used as bone substitutes in large segmental bone defects. The literature indicates that the mechanical and biological properties of scaffolds highly depend on geometrical features...
-
The optimization of enzyme immobilization at Au-Ti nanotextured platform and its impact onto the response towards glucose in neutral media
PublicationThe market of non-invasive glucose sensors is drastically growing due to increasing number of people suffering from diabetes. Therefore, there is a significant need for any improvement in the field of biosensors that can be used for monitoring glucose level in human body. In recent years the emphasis is put onto the modification of electrode material with enzymes possessing recognition centre specific towards particular molecules....
-
Synthesis, Characterization, and Catalytic Applications of the Ti-SBA-16 Porous Material in the Selective and Green Isomerizations of Limonene and S-Carvone
Publication -
Evaluation of the relative thermoluminescence efficiency of LiF:Mg,Ti and LiF:Mg,Cu,P TL detectors to low-energy heavy ions
Publication -
Ti-doped Sr2Fe1.4-xTixMo0.6O6-δ double perovskites with improved stability as anode materials for Solid Oxide Fuel Cells
Publication -
Correlation between structural and electrical properties in highly porous (Y,Sr)(Ti,Nb)O3-delta SOFC anodes
PublicationIn order to find a relationship between structural and electrical properties, niobium and yttrium doped SrTiO3 ceramics were prepared via solid-state reaction. The samples were sintered in hydrogen and air conditions. The samples were also fabricated with a pore-former to obtain highly porous specimens. The electrical properties of Nb-doped SrTiO3 samples and yttrium and niobium co-doped SrTiO3 were compared. The comparable electrical...