Filters
total: 3361
-
Catalog
- Publications 2507 available results
- Journals 52 available results
- Conferences 12 available results
- Publishing Houses 2 available results
- People 159 available results
- Inventions 2 available results
- Projects 16 available results
- Research Teams 3 available results
- Research Equipment 1 available results
- e-Learning Courses 90 available results
- Events 8 available results
- Open Research Data 509 available results
displaying 1000 best results Help
Search results for: biophotnic sensor
-
SENSORS
Journals -
The SARS‐CoV ‐2 specific IgG antibodies biophotonic sensor
PublicationIn this paper, we present the design and the principle of operation of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) specific immunoglobulin G (IgG) biophotonic sensor, which is based on the single-mode telecommunication fiber. We fabricated the sensor head at the face of the single mode fiber-28. Due to the process of bio-functionalization, our sensor has the ability to selectively detect the SARS-CoV-2 specific...
-
Biophotonic low-coherence sensors with boron-doped diamond thin layer
PublicationLow-coherence sensors using Fabry-Perot interferometers are finding new applications in biophotonic sensing, especially due to the rapid technological advances in the development of new materials. In this paper we discuss the possibility of using boron-doped nanodiamond layers to protect mirror in a Fabry-Perot interferometer. A low-coherence sensor using Fabry-Perot interferometer with a boron-doped nanodiamond (B-NCD) thin protective...
-
Journal of Sensors and Sensor Systems
Journals -
e-mentor
Journals -
Sztuczny sensor smaku a zmysł smaku
PublicationOmówiono klasy smaku i działanie zmysłu smaku, który odgrywa ogromną rolę w ocenie jakości żywności metodami organoleptycznymi. Metody te nie są w pełni obiektywne, stąd poszukuje się sztucznego sensora smaku. Przedstawiono szereg rozwiązań prowadzących do opracowania sensora smaku na większą skalę. Omówiono wybrane potencjometryczne i woltamperometryczne sensory smaku, a także ich handlowe modele.
-
SENSORS AND ACTUATORS B-CHEMICAL
Journals -
Journal of Biophotonics
Journals -
A special issue on Biophotonics in Europe
Publication -
Application of electrochemical sensors and sensor matrixes for measurement of odorous chemical compounds
PublicationIn this paper describes the principle of operation of the electrochemical sensors and the sensor matrixes comprised of electrochemical sensors intended for measurement of odorous compounds. Critical comparison of these sensors’ advantages and disadvantages has been made. The fields of economy contributing to release of odours and the potential sources of their emission have been identified. Commercially available electrochemical...
-
IEEE SENSORS JOURNAL
Journals -
Sensors and Sensor’s Fusion in Autonomous Vehicles
PublicationAutonomous vehicle navigation has been at the center of several major developments, both in civilian and defense applications. New technologies such as multisensory data fusion, big data processing, and deep learning are changing the quality of areas of applications, improving the sensors and systems used. New ideas such as 3D radar, 3D sonar, LiDAR, and others are based on autonomous vehicle revolutionary development. The Special...
-
Chapter 11 – Application of Chemical Sensors and Sensor Matrixes to Air Quality Evaluation
PublicationIndoor and outdoor air quality is one of the key factors influencing human health. However, air quality evaluation is not easy task. Air is a complex system, which is subjected to changes even within short period of time. Progress in analytical methods and analytical tools provides increasingly more reliable information on the condition and quality of indoor and outdoor air. This progress, however, generates an increase in the...
-
On the sensitivity, selectivity, sensory information and optimalsize of resistive chemical sensors
PublicationWykorzystano pojęcia teorii informacji do określenia możliwości poprawy selektywności i czujności rezystancyjnych sensorów gazu. Podano ogólne rozważania dotyczące limitu selektywnoœci dla tych sensorów. Porównano iloraz sygnału do szumów oraz pojemność kanału informacyjnego dla sensorów chemicznych wykorzystujących jako sygnał zjawiska fluktuacyjne z klasycznymi sensorami charakteryzowanymi jedną wartością. Ogólne rozważania wsparto...
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublicationIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
TASTE QUALITIES ESTIMATION BY TASTE SENSE AND ELECTROCHEMICAL SENSORS
PublicationThe principles of taste sense and kinds of tastes (sweet, salty, sour, bitter, umami and fat) have been described. Food quality estimation by taste sense: organoleptic testing and sensory analysis has been presented. The principle of operation of potentiom etric sensor composed of several Ion Selective Electrodes or All Solid State Electrodes with polymeric membranes and macromolecular chemical compounds sensitive to substances...
-
A measurement method for lossy capacitive relative humidity sensors based on a direct sensor-to-microcontroller interface circuit
PublicationA new time-domain measurement method for determining the capacitance and resistance values of lossy relative humidity capacitive sensors is presented. The method is based on a direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators and timers. The interface circuit consists only of four reference resistors (two reference resistors if a microcontroller includes a voltage reference source),...
-
SENSORS AND ACTUATORS A-PHYSICAL
Journals -
Time-domain measurement methods for R, L and C sensors based on aversatile direct sensor-to-microcontroller interface circuit
PublicationtIn the paper new time-domain measurement methods for determining values of resistive (R), inductive(L) and capacitive (C) sensors based on a versatile direct sensor-to-microcontroller interface for microcon-trollers with internal analog-to-digital converters (ADCs) and analog comparators (ACs) are presented.The interface circuit consists of a reference resistor Rrworking as a voltage divider, a given R, L or C sensorand a microcontroller...
-
Sensor Review
Journals -
BIOINFO Sensor Networks
Journals -
ACS Sensors
Journals -
Photonic Sensors
Journals -
Sensors International
Journals -
Measurement: Sensors
Journals -
SENSORS AND MATERIALS
Journals -
Fibre-Optic pH Sensor
Publication -
Electrocatalytic nitrogen dioxide sensor.
PublicationOpisano konstrukcję i właściwości elektrokatalitycznego czujnika gazów na bazie domieszkowanego samarem tlenku ceru. Pomiary przeprowadzono w mieszaninie syntetycznego powietrza i dwutlenku azotu. Kształt odpowiedzi prądowo - napięciowej zależy od stężenia NO2.
-
IET Wireless Sensor Systems
Journals -
International Journal of Sensor Networks
Journals -
ACM Transactions on Sensor Networks
Journals -
Sensor Letters
Journals -
<title>Correction of fiber optic ion sensor readings using a fiber optic temperature sensor</title>
Publication -
Hardware-Software Implementation of a Sensor Network for CityTraffic Monitoring Using the FPGA- and ASIC-Based Sensor Nodes
PublicationArtykuł opisuje prototypową sieć sensorową do monitorowania ruchu pojazdów w mieście. Węzły sieci sensorowej, wyposażone w kamerę o niskiej rozdzielczości, obserwują ulice i wykrywają poruszające się obiekty. Detekcja obiektów jest realizowana w oparciu o własny algorytm segmentacji obrazów, wykorzystujący podwójne odejmowanie tła, wykrywanie krawędzi i cieni, działający na dedykowanym systemie mikroelektronicznym typu ''System...
-
Journal of Sensors
Journals -
Electrocatalytic gas sensor response analysis
PublicationW pracy przedstawiono i porównano metody analizy odpowiedzi elektrokatalitycznych czujników gazów toksycznych. Opisane metody pozwalają na ekstrakcje z odpowiediz czujników informacji o rodzaju gazu oraz o jego stężeniu.
-
Spectroscopic and Wireless Sensor of Hematocrit Level
Publication -
Element sensor based on microplasma generators
Publication -
Nanocrystalline undoped ceria oxygen sensor.
PublicationW pracy przedstawiono wyniki badań struktury i elektrycznych właściwości nanokrystalicznego czujnika na bazie niedomieszkowanego tlenku ceru. Zbadano wpływ ciśnienia parcjalnego tlenu na rezystancję cienkowarstwowego tlenku ceru. Konduktancja tlenku ceru w zakresie stężeń tlenu od 10ppm do 100% ma charakter eksponecjalny z parametrem -0.25. Zbadano szybkość odpowiedzi oraz wpływ dwutlenku azotu oraz dwutlenku siarki na odpowiedź...
-
Sztuczny sensor smaku a zmysł smaku
PublicationOmówiono klasy smaku i działanie zmysłu smaku, który odgrywa ogromną rolę w ocenie jakości żywności metodami organoleptycznymi. Metody te nie są w pełni obiektywne, stąd poszukiwanie sztucznego sensora smaku. Przedstawiono szereg rozwiązań prowadzących do opracowania sensora smaku na większą skalę. Omówiono wybrane potencjometryczne i woltamperometryczne sensory smaku, a także ich handlowe modele.
-
Hydrogen sulphide electrocatalytic gas sensor
PublicationIn this article measurement results of the electrocatalytic gas sensor in different concentrations of hydrogen sulphide are presented. Working principle of such sensor is based on electric current acquisition, while voltage ramp is applied to the sensor. During voltage sweep oxidation and reduction reactions occurs on the sensor electrodes. Obtained current-voltage plot has unique shape connected...
-
Electrocatalytic gas sensor with reference layer
PublicationIn recent years electrochemical gas sensors based on solid state electrolytes have been intensively developed. They are easy to obtain, use and relative durable. Nasicon is one of the most promising materials, which have been used in construction of gas sensors. Most of these devices work in potentiometric or amperometric mode. However, some works are dedicated to sensors working in electrocatalytic mode. Principle of operation...
-
Spectroscopic wireless sensor of hematocrit level
PublicationAn optical method for hematocrit measurement is presented. The sensor, designed and developed by authors, consists of a spectroscopic set-up and a microcontroller. The work of the sensor is based on measurement of intensity of two selected spectral bands. Tests confirmed the ability of the sensor to determine the hematocrit level with appropriate measurement accuracy. Measurement results can be transmitted via wireless module to...
-
Spectroscopic and wireless sensor of hematocrit level
PublicationAn optical method for hematocrit measurement has been presented. the sensor, designed and developed by authors, consists of spectroscopic set-up controlled by a microcontroller. measurement results are sent via wireless module. experiment has confirmed the ability of the sensor to determine the hematocrit with appropriate measurementaccuracy.
-
Electrocatalytic Gas Sensor with Reference Layer
PublicationThis paper presents studies of gas sensors prepared in ceramic technology with Nasicon as a solid electrolyte. Sensors work in the voltammetric mode thus based on the excitation of a sensor with a periodic potential signal while current response is recorded. The main aim is to investigate a Bi8Nb2O17 reference layer influence on sensor properties. Sensors I-V characteristics in different concentration of nitrogen dioxide have been...
-
Selectivity of amperometric sulfur dioxide sensor.
PublicationW pracy przedstawiono wartości współczynników selektywności amperometrycznego czujnika ditlenku siarki względem siarkowodoru. Obliczenia wykonane zostały w oparciu o krzywe kalibracyjne wyznaczone dla zaprezentowanego wcześniej przez nas amperometrycznego czujnika ditlenku siarki. Analiza krzywych kalibracyjnych pod względem czułości oznaczenia oraz analiza wartości amperometrycznych współczynników selektywności odgrywa dużą pomocniczą...
-
Optimal Sensor Placement for Damage Detection
PublicationW pracy przedstawiono dwie konfiguracje czujników PZT do detekcji uszkodzeń w płytach. Omówion zalety i wady obu konfiguracji.
-
Identification of defected sensors in an array of amperometric gas sensors
PublicationPurpose Amperometric gas sensors are commonly used in air quality monitoring in long-term measurements. Baseline shift of sensor responses and power failure may occur over time, which is an obstacle for reliable operation of the entire system. The purpose of this study is to check the possibility of using PCA method to detect defected samples, identify faulty sensor and correct the responses of the sensor identified as faulty. Design/methodology/approach In...
-
Sensors and Actuators Reports
Journals -
IEEE Sensors Letters
Journals