Application of RCD and AFDD in low-voltage electrical installations for protection against fire
PublikacjaThe paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.
-
Fire Protection and Materials Flammability Control by Artificial Intelligence
PublikacjaFire safety has become a major challenge of materials developers because of the massive production of organic materials, often combustibles, and their use for different purposes. In this sense, fire safety is critically considered in the development of engineering materials [1, 2]. The multiplicity of parameters contributing to the development of formulation of flame-retardant materials from one side and the sustainability concerns...
-
A design concept of fire protection system for an ecological floating dock
PublikacjaW artykule przedstawiono możliwe do wystąpienia na doku pływającym zagrożenie pożarowe oraz projekt koncepcyjny systemu zabezpieczenia przeciwpożarowego. Projekt ten obejmuje: istalację gaśniczą wodno-hydrantową i pianową do ochrony pokładu głównego oraz instalację CO2 do ochrony siłowni, rozdzielni elektrycznej i tunelu kablowego, a także instalację wykrywania i sygnalizacji pożaru.
-
Protection of bridges against stray current corrosion
PublikacjaA case study of Siennicki Bridge stray current corrosion hazard is presented. A corrosion risk was caused by incorrectly designed tram line traction which goes over the bridge. No dielectric insulation between running rails and bridge steel construction was used. A variety of protection methods against stray currents are described. Characteristics of the endangered bridge were described. Impressed current cathodic protection system...
-
Protection system against electromagnetic leak of information
PublikacjaW pracy omówiono problem zabezpieczenia przed ulotem elektromagnetycznym informacji. Scharakteryzowano obowiązujace w tym względzie wybrane dokumenty normatywne. Opisano stosowane sposoby zapobiegania ulotowi informacji oraz prezentowano metodykę badawczą. Przedstawiono wybrane wyniki pomiarowe.
-
Reliable Anycast and Unicast Routing: Protection against Attacks
PublikacjaObecne sieci są przeważnie chronione przed awariami losowymi, a topologie sieci są w większości uznawane za regularne. Znane mechanizmy ochrony dotyczą typowo transmisji unicast (jeden-do-jednego). Jednakże w związku z obserwowaną konwergencją technologii/usług, inne odmiany transmisji (np. anycast - jeden-do-jednego-z-wielu) nabierają znaczenia. Co więcej, okazuje się, iż często awarie nie mają losowego charakteru, a topologie...
-
Issues related to noise and protection against noise against the background of hazards present in the working environment
PublikacjaNoise is one of the physical factors that poses the greatest threat in the working environment. In order to reduce the noise exposure, noise reduction at the source should be considered. Next, the engineering and administrative controls are being developed. Finally, hearing protectors are used. Issues related to protection against noise are part of the topics in the field of occupational...
-
Chromatographic Examinations of Tea's Protection Against Lipid Oxidative Modifications
Publikacja -
Efficiency of Electret Polycarbonate Nonwovens in Respiratory Protection Against Nanoparticles
Publikacja -
Potential of ASH technology for protection against chemical and biological attacks
PublikacjaTechnologia wykorzystująca reaktor cyklonowy dzięki dużej wydajności posiada szczególne predyspozycje do usuwania lub niszczenia składników broni chemicznej i biologicznej ze strumieni gazów o dużym natężeniu przepływu, pochodzących z systemów ogrzewania, wentylacji i klimatyzacji, bez powodowania znacznych spadków ciśnienia. Reaktor cyklonowy posiada znaczne mniejsze rozmiary, około 10% objętości tradycyjnych systemów oczyszczania...
-
Protection of surface water against contamination by wetland systems in Poland
PublikacjaOpisano systemy hydrofitowe stosowane do usuwania zanieczyszczeń z wód powierzchniowych zasilanych wodami opadowymi. Po wprowadzeniu systemów stwierdzono znaczną poprawę jakości wód analizowanych cieków.
-
Sweet grass protection against oxidative stress formation in the rat brain
Publikacja -
Network Protection Against Node Attacks Based on Probabilistic Availability Measures
Publikacja -
System of protection against electric shock for circuits with power electronics converters
PublikacjaModern low voltage circuits are very often equipped with power electronics converters, therefore in these circuits non-sinusoidal earth currents (touch currents) may occur. For non-sinusoidal currents safety criteria should be modified. This paper presents these modified criteria and a computer system of protection against electric shock which can be implemented in circuits with power electronics converters. The system is based...
-
Highly Dissipative Materials for Damage Protection against Earthquake-Induced Structural Pounding
PublikacjaIt is a common situation that seismic excitations may lead to collisions between adjacent civil engineering structures. This phenomenon, called earthquake-induced structural pounding, may result in serious damage or even the total collapse of the colliding structures. Filling the gap between two buildings erected close to one another by using visco-elastic materials can be considered to be one of the most effective methods to avoid...
-
Green Tea Protection Against Age-Dependent Ethanol-Induced Oxidative Stress
Publikacja -
Argon plasma-modified bacterial cellulose filters for protection against respiratory pathogens
Publikacja -
LabVIEW-based intelligent system of protection against electric shock for photovoltaic installations
PublikacjaEvaluation of shock hazard in installations with photovoltaic sources of energy is more complicated than in a conventional low voltage system. In case of earth fault in photovoltaic generators, that are connected to the AC power public grid, a composite waveform of earth fault current in the installation may occur. For composite waveforms, the safety criteria should be modified. The paper considers the effect of the composite waveforms...
-
Protection against electric shock in electrical installations with low voltage generating sets
PublikacjaW referacie przedstawiono zasady ochrony przeciwporażeniowej, zgodne z wymaganiami międzynarodowymi, w sytuacji kiedy instalacja elektryczna jest zasilana z niskonapięciowych zespołów prądotwórczych. Zwrócono uwagę na dobór zabezpieczeń przeciwporażeniowych oraz na wymiarowanie uziemień.
-
Protection Against Electric Shock Using Residual Current Devices in Circuits with Electronic Equipment
PublikacjaW artykule przedstawiono problematykę stosowania wyłączników różnicowoprądowych w obwodach z urządzeniami elektronicznymi, które powodują, że prąd różnicowy ma zmienną częstotliwość lub jest odkształcony. Wyniki badań wskazują, że częstotliwość obiegająca od znamionowej oraz zawartość wyższych harmonicznych w prądzie różnicowym niekorzystnie wpływa na skuteczność ochrony przeciwporażeniowej przy zastosowaniu wyłączników różnicowoprądowych....
-
Microbial Consortia for Plant Protection against Diseases: More than the Sum of Its Parts
Publikacja -
Distributed protection against non-cooperative node behavior in multi-hop wireless networks
PublikacjaAn important security problem in today's distributed data networks is the prevention of non-cooperative behavior i.e., attacks consisting in the modification of standard node operation to gain unfair advantage over other system nodes. Such a behavior is currently feasible in many types of computer networks whose communication protocols are designed to maximize the network performance assuming full node cooperation. Moreover, it...
-
The consequences of applying a new Polish Water Law Act for protection against urban flooding
PublikacjaPrevious legal regulations did not create conditions for a comprehensive solution to the problems of the urban melioration complex. For over 20 years, urban flooding caused by atmospheric precipitation has been systematically recurring in Poland. The article was elaborated on the experience resulting from the 2001 and 2016 floods in Gdansk (Poland). The newly adopted Water Law Act creates a foundation for a systemic solution...
-
The effect of PWM frequency on the effectiveness of protection against electric shock using residual current devices
PublikacjaW referacie przedstawiono analizę widmową odkształconego prądu ziemnozwarciowego z obwodu silnika o regulowanej prędkości obrotowej za pomocą przemiennika częstotliwości. Oszacowano wpływ tego odkształcenia na próg fibrylacji serca. Analizowano skuteczność ochrony przeciwporażeniowej wykorzystującej wyłączniki różnicowoprądowe przy różnych wartościach częstotliwości PWM przemiennika. Przedstawiono charakterystykę działania zaproponowanego...
-
The effect of PWM frequency on the effectiveness of protection against electric shock using residual current devices
PublikacjaW artykule przedstawiono analizę widmową odkształconego prądu ziemnozwarciowego z obwodu silnika o regulowanej prędkości obrotowej za pomocą przemiennika częstotliwości. Oceniono skuteczność ochrony przeciwporażeniowej wykorzystującej wyłączniki różnicowoprądowe przy różnych wartościach częstotliwości PWM przemiennika. Przedstawiono charakterystykę działania proponowanego wyłącznika różnicowoprądowego.
-
Metrological analysis of an computerized system of protection against electric shock in circuits with variable speed drives
PublikacjaDrive systems, that can be operated at variable speed, are equipped with power electronics converters. This causes distortion of the earth current, and consequently the need to take into account the use of proper protective devices in relation to earth current harmonics. This paper presents a system for protection against electric shock in circuits with power electronics converters and metrological analysis indicating the requirements...
-
Preliminary Evaluation of the Ergonomic Properties of Gloves for Protection Against Mineral Oils Based on Manual Dexterity Tests
Publikacja -
Expert opinion on the effectiveness of protection against electric shock in case of fault in an installation for electric vehicles charging
PublikacjaThe opinion concerns the use of residual current devices for protection against electric shock by automatic disconnection of supply in a Norwegian installation intended for charging of electric vehicles.
-
Evaluation of long‑term immunity and protection against T. gondii after immunization with multivalent recombinant chimeric T. gondii proteins
PublikacjaToxoplasmosis caused by the opportunistic, cosmopolitan protozoan Toxoplasma gondii is one of the most common parasitoses in the world. Although it may prove dangerous or even fatal for immunocompromised individuals, immunoprophylaxis for humans is still nonexistent. Thus, the aim of the current work was to assess the ability of two immunogenic recombinant chimeric T. gondii proteins, SAG2-GRA1-ROP1 (SGR) and SAG1-MIC1-MAG1-GRA2...
-
A Review of Crop Protection Methods against the Twospotted Spider Mite—Tetranychus urticae Koch (Acari: Tetranychidae)—With Special Reference to Alternative Methods
Publikacja -
Aspects of Tests and Assessment of Filtering Materials Used for Respiratory Protection Against Bioaerosols. Part II: Sweat in the Environment, Microorganisms in the Form of a Bioaerosol
Publikacja -
Aspects of Tests and Assessment of Filtering Materials Used for Respiratory Protection Against Bioaerosols. Part I: Type of Active Substance, Contact Time, Microorganism Species
Publikacja -
A Pertussis Outer Membrane Vesicle-Based Vaccine Induces Lung-Resident Memory CD4 T Cells and Protection Against Bordetella pertussis, Including Pertactin Deficient Strains
Publikacja -
Residual Current Devices: Selection, Operation, and Testing
PublikacjaIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...
-
Theoretical modelling of efficient fire safety water networks by certified domination
PublikacjaThis paper explores a new way of designing water supply networks for fire safety using ideas from graph theory, focusing on a method called certified domination. Ensuring a good water supply is crucial for fire safety in communities, this study looks at the rules and problems in Poland for how much water is needed to fight fires in different areas and how this can be achieved at a lowest possible cost. We present a way to plan...
-
Fire-Retardant Flexible Foamed Polyurethane (PU)-Based Composites: Armed and Charmed Ground Tire Rubber (GTR) Particles
PublikacjaInadequate fire resistance of polymers raises questions about their advanced applications. Flexible polyurethane (PU) foams have myriad applications but inherently suffer from very high flammability. Because of the dependency of the ultimate properties (mechanical and damping performance) of PU foams on their cellular structure, reinforcement of PU with additives brings about further concerns. Though they are highly flammable and...
-
Electrical safety in low-voltage DC microgrids with B-type residual current devices
PublikacjaResidual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...
-
PV installations and the safety of residential buildings
PublikacjaThe dynamic development of the photovoltaic industry entails threats that have a direct impact on the safety of residential buildings. Appropriate design of a PV installation can be a challenge due to the multifaceted nature of this issue. The designer should take into account issues related to the selection of electrical parameters of the installation, adapting lightning and surge protection in accordance...
-
Graphene Reinforced Phenolic Foams
PublikacjaPhenolic foams (PF) belong to the polymeric materials, which are very attractive from the point of many possible applications such as insulation or fire protection materials. This chapter attempts to explain the influence of graphene and graphene derivatives on the phenolic foams. This work briefly presents different graphene nanoparticles introduced to the phenolic foams matrix, in terms of impact on the thermal, mechanical, and...
-
Re-use of historic wooden verandas in Sopot, Poland
PublikacjaSopot is the best-known seaside resort in Poland. The city is unique with regard not only to its location and natural values, but also its interesting architecture, which dates back to the end of the 19th and the beginning of the 20th century. Wooden verandas are one of the characteristic features of Sopot architecture. Their origin is associated with the Swiss style, which was fashionable at the turn of the 20th century and quite...
-
Modernization and adaptation of historical interiors
PublikacjaModernization of the historical building's interior entails the need to take many decisions, often conflicting. Operational requirements, protection of the architectural heritage, fire-safety recommendations, construction regulations, all these aspects involve a whole set of problems that require a rational solution, respecting ambient architectural and historical value, as well as the needs arising from the planned transformation....
-
Uziemienia w zespołach elektrowni wiatrowych
PublikacjaW pracy jest omawiana problematyka budowy systemów uziemień na farmach elektrowni wiatrowych. Uziemienia poszczególnych elektrowni są wykorzystywane jako elementy systemu ochrony odgromowej oraz układu ochrony od porażeń otoczenia elektrowni wiatrowej. Farmy elektrowni są często umieszczane na gruntach o wysokiej rezystywności, co utrudnia realizację skutecznych systemów uziemień elektrowni. Trudność może napotykać zwłaszcza wykonanie...
-
Geokompozyty drenażowe w odwodnieniach drogowych i kolejowych
PublikacjaZagadnienie zagospodarowania wód opadowych i gruntowych w rejonie konstrukcji drogowych i kolejowych stanowi istotny element bezpiecznej i efektywnej eksploatacji tych obiektów. Odpowiednie wykorzystanie geokompozytów drenażowych zapewnia bezproblemową pracę konstrukcji oraz właściwą ochronę przed uszkodzeniami wynikającymi z niekontrolowanego oddziaływania wody.
-
Korozja w środowisku ropy naftowej. Czynniki i monitorowanie
PublikacjaPrzedstawiono analizy właściwości ropy naftowej z punktu widzenia zawartych w niej czynników korozyjnych oraz ich wpływu na korozję stali w trakcie procesu destylacji ropy naftowej. Krytycznej analizie poddane zostały możliwości oferowane przez współczesne techniki pomiarowe. Wskazano na istotność prowadzenia kompleksowego programu oceny ropy, monitorowania korozji oraz stosowania ochrony inhibitorowej w celu ochrony instalacji...
-
Polityka i porządek prawny w polskiej energetyce na tle polityki Unii Europejskiej
PublikacjaW artykule przeanalizowano rozwój wspólnotowego rynku energii elektrycznej, polityk ę energetyczną Polski i UE, sytuację i działania Polski na wspólnotowym rynku energii elektrycznej, a następnie przeanalizowano nowe regulacje prawne dla współpracy rozproszonych źródeł energii elektrycznej i sieci inteligentnych z systemem krajowym, dla zwrotu energii odzyskiwanej z systemów elektromechanicznych do zasilającej...
-
Hydrauliczna wiarygodność wyników pomiarów terenowych stosowanych do identyfikacji oporności hydraulicznej przewymiarowanych sieci wodociągowych
PublikacjaPublikacja zawiera zalecenia metodyczne dotyczące identyfikacji oporności hydraulicznej w przewymiarowanych sieciach wodociągowych na tle spotykanych nieprawidłowości. Krytycznie oceniono wyniki pomiarów terenowych, które zastosowano do tarowania komputerowych modeli przepływów (KMP) pomimo, że nie spełniały kryterium hydraulicznej wiarygodności. Ponadto zaproponowano spadek hydrauliczny jako obiektywny wskaźnik wiarygodności pomiarów,...
-
O problemie kolmatacji geowłóknin stosowanych w drenażach
PublikacjaSystemy drenażowe występujące przy obiektach drogowych są niezwykle istotnym elementem tych budowli. Jednym z materiałów, które obecnie powszechnie stosowane są w systemach drenażowych są geowłókniny. Ich zadaniem jest zabezpieczenie odwadnianego gruntu przed procesem sufozji, jak również ochrona drenażu przed zamuleniem przy jednoczesnym zachowaniu wodoprzepuszczalności. Typową trwałość drenażu, w zależności od rozwiązań, szacować...
-
Cząsteczki mikroRNA - nowy biologicznie aktywny składnik mleka kobiecego
PublikacjaCząsteczki mikroRNA są krótkimi, niekodującymi oligonukleotydami odpowiadającymi za potranskrypcyjną regulację ekspresji genów. W wyniku ich aktywności kontrolowanych jest wiele procesów komórkowych oraz szlaków sygnalizacyjnych. Od 2010 roku wiadomo, że wchodzą one w skład mleka kobiecego, które obecnie uznaje się za jedno z najbogatszych pokarmowych źródeł mikroRNA. Funkcje tych cząsteczek w organizmie karmionego mlekiem matki...
-
STANY NIEUSTALONE TOWARZYSZĄCE POMIAROWI IMPEDANCJI PĘTLI ZWARCIA W OBWODACH WYJŚCIOWYCH ZASILACZY BEZPRZERWOWYCH UPS
PublikacjaW pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem...
-
Time-current tripping curves of arc fault detection devices
PublikacjaTripping curves of arc fault detection devices, in accordance with PN-EN 62606 “General requirements for arc fault detection devices” have been presented in the paper. Consequently the most fundamental differences in arc fault detection devices tripping compared to circuit-breakers and residual current devices have been indicated.