Filtry
wszystkich: 3140
wybranych: 2586
-
Katalog
- Publikacje 2586 wyników po odfiltrowaniu
- Czasopisma 80 wyników po odfiltrowaniu
- Konferencje 5 wyników po odfiltrowaniu
- Osoby 91 wyników po odfiltrowaniu
- Projekty 3 wyników po odfiltrowaniu
- Kursy Online 74 wyników po odfiltrowaniu
- Wydarzenia 24 wyników po odfiltrowaniu
- Oferty 1 wyników po odfiltrowaniu
- Dane Badawcze 276 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: overhead power lines
-
Structural reliability of overhead power lines by means of Monte Carlo Method and RSM
PublikacjaThe article discusses the issue of reliability assessment of overhead power lines by means of both Monte Carlo Method and Response Surface Method. The suspension tower OS24 ON150+10 is considered, as the weakest element of the line. A comparison is made between deterministic and probabilistic approaches to wind and icing loading. The PDFs for wind and icing loads are proposed. Reliability is assessed for both critical atmospheric...
-
Case studies of resonance phenomena in high voltage overhead power lines with shunt reactors
PublikacjaMisguided design of the towers of power transmission lines can lead to serious problems such as voltage asymmetry, overvoltages, electric arc extinction difficulties or resonance – in case of double circuit line with shunt reactors. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors.
-
Structural Health Monitoring of Overhead Power Transmission Lines
PublikacjaStructural Health Monitoring (SHM) is a novel and continuously developing branch of science and technology that draws attention of scientists all over the world. It creates opportunities to detect, localize and identify structural damage of various types such as: line breakage, permissible sag, bolt loosening, fatigue cracking or insulator contamination. On the other hand the methods used to estimate the remaining operational...
-
Impulse Measurements of Tower Earthings of Overhead Transmission Lines
PublikacjaPrzepisy wymagają okresowego badania uziemień słupów elektroenergetycznych linii przesyłowych. pomiary takie metodami klasycznymi niskiej częstotliwości wymagają odłączania uziomów od konstrukcji słupa, co wiąże się z wyłączaniem linii. wykorzstanie metody udarowej do oceny uziemień nie wymaga odłączania uziomów i może byc przeprowadzane podczas pracy linii.
-
Analysis and Detection of Faults at Insulated Conductors of Overhead Medium Voltage Lines
PublikacjaThe paper dealt with the issue of breakdowns detection of isolated hanging wires on the medium-voltage transmission. The main aim of article is to describe the function of created breakdowns detector and evaluation its. The breakdowns detector is created based in indicators of faults such as touch between tree limbs and insulated wire, touch tree limbs with several phases or fall insulated wire on the ground. Breakdowns detector...
-
Computer-Aided Calculations of Earth Potential Rise in High Voltage Overhead Lines
PublikacjaHigh voltage overhead power lines with earth wires comprise towers made of conductive material. Some towers are in locations where people can be expected to be either for a long time or for a short time but very frequently. Evaluation of shock hazard near such towers requires calculation of line-to-earth short-circuit current, earth current and especially earth potential rise. Number of towers in high voltage power lines can exceed...
-
Application of 3D graphic software and GIS in visual impact assessment of high-voltage overhead transmission lines
Publikacja -
Damage Detection Strategies in Structural Health Monitoring of Overhead Power Transmission System
PublikacjaOverhead power transmission lines, their supporting towers, insulators and other elements create a highly distributed system that is vulnerable to damage. Typical damage scenarios cover cracking of foundation, breakage of insulators, loosening of rivets, as well as cracking and breakage of lines. Such scenarios may result from various factors: groundings, lightning strikes, floods, earthquakes, aeolian vibrations, conductors galloping,...
-
The Issues of Reactive Power Compensation in High-voltage Transmission Lines
PublikacjaThis paper discusses the selection of compensation shunt reactors for a double-circuit 400 kV transmission line using the example of the newly built Elk Bis – Alytus transmission line. The analysis takes into account various conditions of the power system. The published results relate to voltage levels in steady states and during switching processes and short circuits.
-
Magnetic and capacitive couplings influence on power losses in double circuit high voltage overhead transmission line
PublikacjaPurpose – The paper aims to discuss problems of power and energy losses in a double-circuit overhead transmission line. It was observed from energymeters’ readings, that in such a line, active power losses can be measured as “negative”. The “negative” active power losses appear when the active power injected to the circuit is lower than the active power received at the circuit end. The purpose of this paper is to explain this phenomenon. Theoretical...
-
Design of power cable lines partially exposed to direct solar radiation – special aspects
PublikacjaPower cable lines are usually buried in the ground. However, in some cases, their ending sections are mounted along the supports of overhead lines. This leads to a situation where the cables are exposed to direct solar radiation and, consequentially, overheat. The paper presents the advanced computer modelling of power cables’ heating, considering their insolation as well as the effect of wind. The temperature and current-carrying...
-
Magnetic and capacitive couplings influence on power and energy measurement in double circuit high voltage overhead transmission line
PublikacjaThe paper discusses influence of magnetic and capacitive couplings on power and energy measurement in case of double circuit high voltage overhead transmission line. There are presented and discussed various factors influencing the power flow among the line‟s circuits. Mathematical model based calculations results are compared to the real transmission line measurements.
-
The impact of the overhead line's power supply system spatial differentiation on the energy consumption of trolleybus transport: planning and economic aspects
PublikacjaNowadays the issue of electric energy saving in public transport is becoming a key area of interest, which is connected both with a growth in environmental awareness of the society and an increase in the prices of fuel and electricity. It can be achieved by reducing of the transmission losses in supply system or by the improving of the usage of the regenerative breaking. The spatial differentiation of the energy supply system of...
-
The Finite Elements Method application to assesment the impact of turbulence generated by wind turbines on their lacation inclose proximity of overhead high voltage power transmissionlines
PublikacjaThe paper presents selected aspects of construction of wind turbines location concerning aerodynamic impact on power lines. Reaserch is based on the source data concerning the aerodynamic impact of a wind farm consisting of 8 turbines and 400 kV power line, an analysis of the possibility of wind farm locating in the immediate vicinity of the line was carried out. There are serious problems with locating higher capacity wind farms...
-
Modelling of MV and HV Cable Lines
PublikacjaOverhead and cable lines are fundamental elements of power systems. Participation of cable lines is smaller and their percentage decreases as voltage is increased. HV cable lines are often built with the use of cables which are composed of coaxial metallic sheaths. Such cables are also often used in MV networks. The sheath may operate in different confgurations. In the case of Polish MV network the sheaths are earthed at both ends....
-
Overheating of underground power cable line due to its partial exposition to solar radiation
PublikacjaCurrent-carrying capacity of underground power cable lines depends, among others, on thermal resistivity of the soil and cables layout: trefoil formation, flat formation with or without spacing. If conditions for heat transfer in the ground are favorable, the current-carrying capacity is relatively high. Therefore, it generates risk of the power cables overheating, if part of the cable line is located vertically in the air, to...
-
Risk of power cables insulation failure due to the thermal effect of solar radiation
PublikacjaLow-voltage, as well as high-voltage power cable lines, are usually buried in the ground. The ampacity of the power cables in the ground mainly depends on the thermal resistivity of the soil, which may vary in a wide range. A common practice in power cable systems performance is to supply them from a pole of an overhead line. If so, a section of the line is located in free air and can be directly exposed to solar radiation. In...
-
Sustainable Use of the Catenary by Trolleybuses with Auxiliary Power Sources on the Example of Gdynia
PublikacjaThe current developments in onboard power source technology, in particular, traction batteries, open up new potential in trolleybus transport and also make it possible to introduce electric buses. Thus far, trolleybus transport has required the presence of overhead lines (OHL). Introducing trolleybuses with onboard batteries makes it possible to grow the zero-emissions transport network in places with limited power supply capabilities...
-
Trolleybus with traction batteries for autonomous running
PublikacjaIn 2009 the transport company of city Gdynia (Poland) introduced in the operation trolleybuses fitted with traction batteries. This solution was designed for emergency situations, such as: damage of overhead lines or power loss. Transport company also considering the use of batteries in regular use. The article presents the operational experiences gained during the current operation. Furthermore, there are presented new trends...
-
Trolleybuses with traction batteries for autonomous running
PublikacjaIn 2009 the transport company of city Gdynia (Poland) introducet in the operation trolleybuses fitted with traction batteries. This solution was designed for emergency situations, such as: damage of overhead lines or power loss. Transport company also considering the use of batteries in regular use. The article presents the operational experiences gained during the current operation. Furthermore, there are presented new trends...
-
Earth wires currents calculation by tableau analysis
PublikacjaThe paper presents a new method to compute a phase-to-earth fault current distribution in overhead transmission line. The method is based on the tableau analysis of an unbalanced, multi-wire model of a transmission line. It allows for the calculation of current distribution in overhead earth wires along the transmission line. Additionally, it may be used to calculate currents in a tower’s earthing system as well as voltages over...
-
Sieć sensorowa do rejestracji drgań górnej sieci trakcyjnej w celach diagnostyki eksploatacyjnej
PublikacjaWraz ze wzrostem prędkości kolejowych pojazdów elektrycznych zwiększają się wymagania utrzymania sieci trakcyjnej w odpowiednim stanie technicznym. Ciągły monitoring i diagnostyka pozwalają wykrywać pogarszającą się jakość odbioru prądu z sieci jezdnej. Jedną z metod jest umieszczenie czujników przyspieszenia na przewodzie jezdnym. Analiza przebiegu przyspieszenia pozwala określić jakość współpracy sieci jezdnej z pantografem....
-
Comparison of thresholding algorithms for automatic overhead line detection procedure
PublikacjaThe article presents an overview of the thresholding algorithms. It compares the algorithms proposed by Pun, Kittler, Niblack, Huang, Rosenfeld, Remesh, Lloyd, Riddler, Otsu, Yanni, Kapur and Jawahar. Additionally, it was tested how the tuning of the Pun, Jawahar and Niblack methods affects the thresholding efficiency and proposed a combination of the Pun algorithm with a priori algorithm. All presented algorithms have been implemented...
-
Storage electric multiple units on partially electrified suburban railway lines
PublikacjaThe paper presents possible environmental, energy and economical gains implied by replacing conventional traction vehicles with independent powered electric multiple units (IPEMU) on partially electrified suburban railways. IPEMUs can operate in two modes of power supply – using overhead catenary or onboard battery storage. Appropriate computer simulations were carried out in the Matlab program, indicating the parameters of storage...
-
Analysis of energy efficiency of suburban railway transport network
PublikacjaRising numbers of agglomeration residents cause increased need for people movement on daily basis. Because of congestion of local roads, air pollution and limited parking space, providing mass transit based on electric traction is reasonable. While the electric rail vehicles are considered highly efficient in themselves, they need to be analyzed as a part of a transport network, because energy consumption depends on operating conditions...
-
Ensuring sustainable development of urban public transport: A case study of the trolleybus system in Gdynia and Sopot (Poland)
PublikacjaElectromobility is a vital tool in reducing the environmental impact of transportation. A technologically mature means of public transport is the trolleybus. Based on a case study of the Polish cities of Gdynia and Sopot, this paper explores the factors that influence the development of the trolleybus system. Recent developments of in-motion charging (IMC) technology are analysed what provides a new analytical framework for the...
-
Verification of a Novel Method of Detecting Faults in Medium-Voltage Systems with Covered Conductors
PublikacjaThis paper describes the use of new methods of detecting faults in medium-voltage overhead lines built of covered conductors. The methods mainly address such faults as falling of a conductor, contacting a conductor with a tree branch, or falling a tree branch across three phases of a medium-voltage conductor. These faults cannot be detected by current digital relay protection systems. Therefore, a new system that can detect the...
-
EHV transmission lines wires location on line operation issues - case studies
PublikacjaTransmission lines towers construction affects the line parameters and influences on its operation in the future. Misguided design of the tower can lead to serious problems such as overvoltages, electric arc extinction difficulties, voltage asymmetry, resonance phenomena or increasing of magnetic field near the line. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors....
-
Possibilities for Developing Electromobility by Using Autonomously Powered Trolleybuses Based on the Example of Gdynia
PublikacjaTrolleybus transport refers to contemporary challenges related to a reduction in emissions of greenhouse gases and CO2 into the atmosphere formulated by international institutions, such as the United Nations, the Organisation for Security and Co-operation in Europe, or the European Union. Departure from fossil fuels in urban transport is one of the key challenges for the coming years. Trolleybuses are an important tool in this...
-
Modelowanie matematyczne górnej sieci trakcyjnej dla potrzeb diagnostyki odbieraków prądu
PublikacjaGórna sieć trakcyjna jest obecnie najbardziej skutecznym sposobem zasilania kolejowych pojazdów elektrycznych. Wzrost prędkości pojazdów zwiększa pobór mocy i wymaga zapewnienia właściwej współpracy odbieraków prądu pojazdów z siecią jezdną. Metody modelowania i projektowania wspomaganego komputerowo dla górnej sieci trakcyjnej są obecnie na całym świecie szeroko rozwijane. W artykule przedstawiono nowy model matematyczny elementów...
-
Nowa metoda diagnostyki stanu technicznego nakładek stykowych
PublikacjaThe current collection system, which consists of the overhead contact line and a current collector, is particularly important in electric rail vehicles, where their reliability is concerned. Faultless current collection is conditioned not only by suitable construction of these elements but also by their proper maintenance. Retaining permanent electrical contact is essential in DC systems, where current demand is relatively high. In...
-
Nowa metoda obliczania rozpływu prądów zwarciowych w przewodach odgromowych linii wysokiego napięcia
PublikacjaReferat przedstawia nowatorską metodę obliczania wartości prądów płynących w przewodach odgromowych w czasie zwarć, pozwalającą na dobór przewodów odgromowych pod względem wytrzymałości cieplnej. Proponowana metoda charakteryzuje się większą dokładnością i większą uniwersalnością niż powszechnie stosowane metody, pozwalając tym samym na dobór przewodów odgromowych z mniejszym ryzykiem niepewności. Prezentowana metoda obliczeniowa...
-
Przesył energii elektrycznej - potrzeby,progi i bariery
PublikacjaW artykule przeanalizowano stan aktualny i kierunki rozwoju krajowego systemu przesy ł owego w kontek ś cie potrzeb gospodarki krajowej. Przedstawiono znaczenie sieci przesy ł owych oraz rol ę operatorów systemu przesy ł owego i systemów dystrybucyjnych w sektorze energetycznym. Oceniono mo ż liwo ś ci rozwoju przy uwzgl ę dnieniu aktualnych prognoz zapotrzebowania na energi ę , wytyczono potencjalne...
-
Wpływ wprowadzenia norm europejskich na konstrukcję wsporczych napowietrznych linii elektroenergetycznych
PublikacjaKonstrukcje wsporcze linii elektroenergetycznych były i są projektowane zgodnie ze specjalistycznymi normami, innymi niż stosowane w budownictwie. Dotyczą one zarówno oddziaływań środowiskowych, takich jak temperatura, wiatr, oblodzenie i oddziaływania stałe (naciąg, przewodów, osprzęt), jak i zasad wymiarowania. W artykule przedstawiono wyniki analiz porównawczych dotyczących wpływu zmian wprowadzanych w normach europejskich na...
-
Zastosowanie specjalnego uziemienia żył powrotnych w liniach kablowych SN
PublikacjaW artykule porównano metody uziemiania żył powrotnych kabli średniego napięcia. Głównym kryterium oceny poszczególnych rozwiązań było ograniczenie strat w przesyle energii elektrycznej oraz zapewnienie ochrony przeciwprzepięciowej osłon kabli. Na podstawie symulacji kabli zamodelowanych w programie CYMCAP i otrzymanych wyników obciążalności prądowej i strat w linii zaprezentowano metodę krzyżowania żył powrotnych (CB – cross-bonding...
-
Porównanie działania transformatora symetryzującego (zygzak) z aktywnym energoelektronicznym symetryzatorem prądów fazowych linii niskiego napięcia
PublikacjaNa potrzeby planowania sieci niskiego napięcia operatorzy systemów dystrybucyjnych (OSD) zakładają symetryczne warunki obciążenia linii. Z roku na rok, rośnie liczba rozproszonych systemów fotowoltaicznych (PV) zainstalowanych w sieciach niskiego napięcia, których większość to małe jednofazowe systemy dachowe. Dodatkowo, do niesymetrii obciążenia przyczyniają się instalowane masowo pompy ciepła i ładowane jednofazowo samochody...
-
Wielopoziomowy przekształtnik trakcyjny SiC z izolacją od sieci 3kV DC realizowaną za pomocą transformatorów 30kHz do napędów EZT
PublikacjaW referacie przedstawiono wielopoziomowy izolowany kaskadowy przekształtnik DC-AC z tranzystorami SiC MOSFET 1,2kV, przeznaczony do napędów elektrycznych zespołów trakcyjnych (EZT). Zaproponowana konstrukcja przekształtnika, przeznaczonego do pracy przy zasilaniu z sieci trakcyjnej 3kV DC, spełnia założenia energoelektronicznego transformatora trakcyjnego (z ang. Power Electronic Traction Transformer). Budowa modułowa z niskonapięciowych...
-
The issue of uncertainty of visual measurement techniques for long distance measurements based on the example of applying electric traction elements in diagnostics and monitoring
PublikacjaRail transport is the most economical and energy-effective in the field of land transport, in particular electrified. In order to ensure efficient and reliable operation of electrified rail transport, the issues of monitoring and diagnostics of the traction infrastructure and vehicles are extremely important. The most critical point in the transmission of electric energy to the vehicle is the sliding contact of the current collector...
-
Możliwości zastosowania zasobnikowych jednostek trakcyjnych na liniach kolejowych na przykładzie Pomorskiej Kolei Metropolitalnej
PublikacjaW artykule zwrócono uwagę, że zasobniki stosowane głównie do rekuperacji energii, mogą być również wykorzystane do zasilania pociągów na niezelektryfikowanych i zelektryfikowanych odcinkach linii kolejowych. Innowacyjność tego rozwiązania wykazano na podstawie dwóch aplikacji kolejowych elektrycznych zasobnikowych jednostek trakcyjnych: pierwszej funkcjonującej od 2014 roku na linii Utsunomiya – Karasuyama w Japonii oraz drugiej,...
-
Mathematical modelling of the overhead contact line for the purpose of diagnostics of pantographs
PublikacjaThe overhead contact line (OCL) is the most effective way for supplying railway electric vehicles. The increase of the speed of the vehicles increases power consumption and requires ensuring proper cooperation of pantographs with OCL. The paper describes the novel mathematical model of the OCL system and the simulation results. The primary objective is a more accurate analysis to increase the reliability of the evaluation of monitoring...
-
Overhead wires detection by FPGA real-time image processing
PublikacjaThe paper presents design and hardware implementation of real-time image filtering for overhead wires detection divided on image processing and results presentation blocks. The image processing block was separated from the whole implementation, and its delay and hardware complexity was analysed. Also the maximum frequency of image processing of the proposed implementation was estimated.
-
Resonance problems in UHV transmission lines
PublikacjaThe paper presents resonance phenomena observed in 400 kV transmission lines in the Polish power system. Two events are analysed, when shunt reactors used for reactive power compensation, caused overvoltages and overcurrent protection tripping as a result of resonance. An oscillographic fault recordings from protection devices are compared to time domain simulation results. The obtained simulation results match fault recordings,...
-
Rozpoznawanie oraz lokalizacja w obrazie przewodów linii wysokiego napięcia
PublikacjaW pracy przedstawiono opracowany algorytm rozpoznawania oraz lokalizacji przewodów linii wysokiego napięcia na podstawie obrazu horyzontalnego. Procedura detekcji przewodu została podzielona na trzy etapy. Pierwszy etap zawiera algorytm wykrywania krawędzi wykazujący największą czułość na krawędzie poziome, a jednocześnie brak czułości na krawędzie pionowe. Efektem jest znaczna redukcja liczby wykrytych krawędzi w porównaniu do...
-
ROBOT TYPU QUADROCOPTER STEROWANY MIKROKONTROLERAMI O NIEWIELKIEJ MOCY OBLICZENIOWEJ
PublikacjaWspółczesna robotyka rozwija się bardzo dynamicznie. Coraz więcej osób prywatnych i inżynierów konstruuje różnego rodzaju pojazdy mobilne. Dlatego autorzy niniejszego referatu postawili sobie następującą tezę: możliwa jest budowa latającego robota mobilnego na bazie kontrolera o niskiej mocy obliczeniowej oraz prostego regulatora, i podjęli się jej udowodnienia.
-
Method of lines for physiologically structured models with diffusion
PublikacjaWe deal with a size-structured model with diffusion. Partial differential equations are approximated by a large system of ordinary differential equations. Due to a maximum principle for this approximation method its solutions preserve positivity and boundedness. We formulate theorems on stability of the method of lines and provide suitable numerical experiments.
-
THE APPLICATION OF KALMAN FILTERING TO PREDICT VERTICAL RAIL AXIS DISPLACEMENTS OF THE OVERHEAD CRANE BEING A COMPONENT OF SEAPORT TRANSPORT STRUCTURE
PublikacjaAs the devices designed to transport materials, the overhead cranes should meet certain geometric requirements for their operation to be safe. The presently available geodetic equipment, in particular total stations, provides opportunities for precise 3D measurements of coordinates of the controlled points. These coordinates make a basis for correcting the height of crane runway axes. The paper presents a method to calculate position...
-
Calculations of Short-Circuit Current Flows in Earth Wires of HV Lines
PublikacjaThis paper presents a method which enables calculating flows of short-circuit currents in earth wires of high voltage transmission lines, and its implementation in the form of a computer programme. The algorithm enables performing calculations for a double-fed line and starconnected lines (three terminal lines). The developed programme enables verifying dimensioning of earth wires in the context of their short-circuit thermal withstand...
-
Power and energy measurement problems in transmission line between Poland-Lithuania
PublikacjaThe paper discusses problem of power and energy metering in double circuit overhead transmission line. Considerations are based on example of transmission line connecting Polish substation Bis Elk and Lithuanian substation Alytus.
-
Incomplete Cross-Bonding in the MV Line. Experience from the Operation of MV Single Cable Lines
PublikacjaCable lines are one of the basic components of power systems. Medium and high voltage cables mainly comprise a metallic sheath, which is concentric to the main core conductor. There are several operating schemes of such cable lines, which differ in the place of earthing of sheaths and the possible use of the sheaths and/or conductors crossing. The sheaths cross-bonding is typically done in two places of one cable line section,...
-
Interior Point Method Evaluation for Reactive Power Flow Optimization in the Power System
PublikacjaThe paper verifies the performance of an interior point method in reactive power flow optimization in the power system. The study was conducted on a 28 node CIGRE system, using the interior point method optimization procedures implemented in Power Factory software.