ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drills at the feet, grounding the bathtub - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on the measuring electrodes, drl outside the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on both sides, measuring electrodes on the front and back of the bathtub- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the water, measuring electrodes on the sides of the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath mass on the other - the person is moving- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl outside the bathtub on both sides- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in water, front and back measuring electrodes - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on measuring electrodes, drl in water - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath, the mass of the system on the other- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - conversation during measurement, electrodes on the sides of the bathtub, drl in water - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the bathtub, electrodes on the sides of the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, bath simulation - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - buttocks electrodes, reinforcement 2x smaller, drl on knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Raman data of deuterium and hydrogen grown boron-doped diamond
Dane BadawczeRaman spectra were recorded at room temperature using a micro-Raman spectrometer (Invia, Renishaw) equipped with an edge filter with different excitation wavelengths and lasers: UV λ = 325 nm (HeCd), blue λ = 488 nm (Ar+), green λ = 514 nm (Ar+), and IR λ = 785 nm (IR diode) and 50× microscope objective. To avoid sample heating, the radiation power...
-
Temperature Fiber-Optic Sensor with ZnO ALD Coating
PublikacjaThis study presents a microsphere-based fiber-optic sensor with a ZnO Atomic Layer Deposition (ALD) coating thickness of 100 nm for temperature measurements. Metrological properties of the sensor were investigated over the temperature range of 100 °C to 300 °C, with a 10 °C step. An interferometric signal is used to control whether the microstructure is whole. Spectrum shift of a reflected signal is used to ascertain changes in...
-
Ice Load Characteristics on Floating Photovoltaic Platform
PublikacjaNowadays, based upon human needs and preferring perpetual types of energy, photovoltaic system (PV) is a suitable alternative and more frequently used in northern countries, which are recently more attracted by solar power. The new floating type of the structure is installed in the water bodies instead of land. One of the main elements in floating photovoltaic structures is the forces imposed on the panels. In the northern regions,...
-
Correlation–polarization effects in electron/positron scattering from acetylene: A comparison of computational models
PublikacjaDifferent computational methods are employed to evaluate elastic (rotationally summed) integral and differential cross sections for low energy (below about 10 eV) positron scattering off gas-phase C2H2 molecules. The computations are carried out at the static and static-plus-polarization levels for describing the interaction forces and the correlation–polarization contributions are found to be an essential component for the correct...
-
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors_part_2
Dane BadawczeThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
Spectroscopic wireless sensor of hematocrit level
PublikacjaAn optical method for hematocrit measurement is presented. The sensor, designed and developed by authors, consists of a spectroscopic set-up and a microcontroller. The work of the sensor is based on measurement of intensity of two selected spectral bands. Tests confirmed the ability of the sensor to determine the hematocrit level with appropriate measurement accuracy. Measurement results can be transmitted via wireless module to...
-
Curlicues generated by circle homeomorphisms
PublikacjaWe investigate the curves in the complex plane which are generated by sequences of real numbers being the lifts of the points on the orbit of an orientation preserving circle homeomorphism. Geometrical properties of these curves such as boundedness, superficiality, local discrete radius of curvature are linked with dynamical properties of the circle homeomorphism which generates them: rotation number and its continued fraction...
-
An Analysis of Elliptical-Rectangular Patch Structure on Multilayer Elliptic Cylinders
PublikacjaThe resonance frequency problem of an ellipticalrectangular patch mounted on multilayered dielectric coated elliptic conducting cylinder, is investigated in this paper. A fullwave analysis and a moment-method calculation are employed. The analysis is carried out considering the expansion of the field as a series of Mathieu functions. An additional theorem for Mathieu functions is utilized to investigate the non-confocal ellipse...
-
An Analysis of Multistrip Line Configuration on Elliptical Cylinder
PublikacjaA configuration of multistrip lines mounted on a multilayer dielectric coated elliptic cylinder is investigated in this paper. A full-wave analysis and a moment-method calculation are employed. The analysis is carried out considering the expansion of the field as a series of Mathieu functions. Both open and shielded lines are considered in the analysis. Propagation coefficients and characteristic impedances are calculated for the...
-
Reduction of the Multipath Propagation Effect in a Hydroacoustic Channel Using Filtration in Cepstrum
PublikacjaDuring data transmission in a hydroacoustic channel, one of the problems is the multipath propagation effect, which leads to a decrease in the transmission parameters and sometimes completely prevents it. Therefore, we have attempted to develop a method, which is based on a recorded hydroacoustic signal, that allows us to recreate the original (generated) signal by eliminating the multipath effect. In our method, we use cepstral...
-
Investigation of the temperature modulation parameters on semiconductor gas sensor response
PublikacjaIn this work we present the results of the investigation of the sensing properties of semiconductor gas sensors with a sinusoidally modulated temperature in the presence of synthetic air (SA) and three volatile air pollutants, i.e. NH3, NO2 and SO2. The measurements were performed for different average sensor heater temperatures and the amplitude of the modulation signal. In addition, the extraction of features from the sensor...
-
Measurements of the optical and thermal properties of the 2D black phosphorus coating
PublikacjaBlack phosphorus is a 2D material, which properties are still being discovered. In this paper, the sensitivity to the temperature of a few-layer black phosphorus coating deposited, on the surface of a microsphere-based fiber-optic sensor, by a dip-coating method is presented. The coating was investigated after 2, 3, and 5 deposition cycles and during temperature growth from 50 °C to 300 °C in an interferometric setup. The intensity...
-
Design of OFDM-based radio communication systems for coast-to-sea and coast-to-air propagation environments
PublikacjaIn the paper the study of radio communication system design process for systems based on OFDM transmission is considered. The signal propagation model for 1.4 GHz frequency band is discussed, and the study of signal propagation characteristics, important from the point of view of OFDM system design, is presented. The methodology of OFDM interface design is proposed and some characteristics of the OFDM-based radio communication...
-
ECG measurement in the bathtub - drl on one side of the bathtub, the other side of the bathtub is grounded and the system ground is grounded- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Gas Detection Using Resistive Gas Sensors And Radial Basis Function Neural Networks
PublikacjaWe present a use of Radial Basis Function (RBF) neural networks and Fluctuation Enhanced Sensing (FES) method in gas detection system utilizing a prototype resistive WO3 gas sensing layer with gold nanoparticles. We investigated accuracy of gas detection for three different preprocessing methods: no preprocessing, Principal Component Analysis (PCA) and wavelet transformation. Low frequency noise voltage observed in resistive gas...
-
Detection and Direction-of-Arrival Estimation of Weak Spread Spectrum Signals Received with Antenna Array
PublikacjaThis paper presents a method for the joint detection and direction of arrival (DOA) estimation of low probability of detection (LPD) signals. The proposed approach is based on using the antenna array to receive spread-spectrum signals hidden below the noise floor. Array processing exploits the spatial correlation between phase-delayed copies of the signal and allows us to evaluate the parameter used to make the decision about the...
-
Heart rate PPG signals with acceleration captured at wrist during small and moderate body movements
Dane BadawczeHeart rate PPG signals with acceleration captured at wrist during small and moderate body movements
-
Instantaneous complex frequency for pipeline pitch estimation
PublikacjaIn the paper a pipeline algorithm for estimating the pitch of speech signal is proposed. The algorithm uses instantaneous complex frequencies estimated for four waveforms obtained by filtering the original speech signal through four bandpass complex Hilbert filters. The imaginary parts of ICFs from each channel give four candidates for pitch estimates. The decision regarding the final estimate is made based on the real parts of...
-
Superresolution algorithm to video surveillance system
PublikacjaAn application of a multiframe SR (superresolution) algorithm applied to video monitoring is described. The video signal generated by various types of video cameras with different parameters and signal distortions which may be very problematic for superresolution algorithms. The paper focuses on disadvantages in video signal which occur in video surveillance systems. Especially motion estimation and its influence on superresolution...
-
Comparison of Acoustic and Visual Voice Activity Detection for Noisy Speech Recognition
PublikacjaThe problem of accurate differentiating between the speaker utterance and the noise parts in a speech signal is considered. The influence of utilizing a voice activity detection in speech signals on the accuracy of the automatic speech recognition (ASR) system is presented. The examined methods of voice activity detection are based on acoustic and visual modalities. The problem of detecting the voice activity in clean and noisy...
-
Nonreciprocal properties of elliptical ferrite coupled line junction
PublikacjaIn this paper the nonreciprocal properties of el-liptical ferrite coupled line (EFCL) junction are examined. In the analysis the technique combining spectral-domain approach (SDA) with coupled-mode method (CMM) is applied. The nu-merical results concerning gyromagnetic coupling coefficient of ferrite coupled lines and scattering matrix of EFCL junction are presented. The obtained results are validated with the use of commercial...
-
Discussion on “Coupled effective stress analysis of insertion problems in geotechnics with the Particle Finite Element Method” by L. Monforte, M. Arroyo, J.M. Carbonell, and A. Gens
PublikacjaAddressed here is the Particle Finite Element Method (PFEM) modelling of undrained CPTu penetration with regard to a reference analytical solution based on the Spherical Cavity Expansion Method (SCEM). Also discussed is the choice of the soil model and its parameters. The effect of cone interface friction on CPTu simulation is analyzed in a series of penetration tests using Arbitrary Lagrangian-Eulerian (ALE) and Updated Lagrangian...
-
Rzadka reprezentacja sygnału niestacjonarnego w technice oszczędnego próbkowania
PublikacjaPrzedstawiono zastosowanie techniki oszczędnego próbkowania do rekonstrukcji sygnału niestacjonarnego na podstawie skompresowanych próbek w dziedzinie czas-częstotliwość. Zastosowano nadmiarowy algorytm z różnymi słownikami aby znaleźć rzadką reprezentację sygnału. Wyniki symulacji potwierdzają, że zastosowanie oszczędnego próbkowania pozwala na rekonstrukcję sygnału niestacjonarnego z małej liczby losowo pobranych próbek, z niewielką...
-
Fully Adaptive Savitzky-Golay Type Smoothers
PublikacjaThe problem of adaptive signal smoothing is consid-ered and solved using the weighted basis function approach. Inthe special case of polynomial basis and uniform weighting theproposed method reduces down to the celebrated Savitzky-Golaysmoother. Data adaptiveness is achieved via parallel estimation.It is shown that for the polynomial and harmonic bases andcosinusoidal weighting sequences, the competing signal estimatescan be computed...
-
Audio content analysis in the urban area telemonitoring system
PublikacjaArtykuł przedstawia możliwości rozwinięcie monitoringu miejskiego o automatyczną analizę dźwięku. Przedstawiono metody parametryzacji dźwięku, które możliwe są do zastosowania w takim systemie oraz omówiono aspekty techniczne implementacji. W kolejnej części przedstawiono system decyzyjny oparty na drzewach zastosowany w systemie. System ten rozpoznaje dźwięki niebezpieczne (strzał, rozbita szyba, krzyk) wśród dźwięków zarejestrowanych...
-
Position Estimation in Corridors Along the Coupled Mode of Radiating Cables
PublikacjaRadiating cables are mostly used to provide radio communication in tunnels or corridors, but they can also be used to estimate the position of a mobile terminal along the cable. In this paper, a measuring receiver’s position was estimated by measuring the difference in the direct signal’s reception time, which was generated by a transmitter connected to one end of the radiating cable, and the delayed signal retransmitted from another...
-
Quality Evaluation of Novel DTD Algorithm Based on Audio Watermarking
PublikacjaEcho cancellers typically employ a doubletalk detection (DTD) algorithm in order to keep the adaptive filter from diverging in the presence of near-end speech signal or other disruptive sounds in the microphone signal. A novel doubletalk detection algorithm based on techniques similar to those used for audio signal watermarking was introduced by the authors. The application of the described DTD algorithm within acoustic echo cancellation...
-
Atomic Force Microscope data post-processing algorithm for higher harmonics imaging
PublikacjaPrevious works have proved that higher harmonics topography imaging using atomic force microscope (AFM) can significantly enhanced its measurement capabilities. Integrated tools dedicated to most of microscopes allow to visualize the investigated surface only by one selected harmonic. Because of the different characteristics of a sample, scanning tip and the environment, appropriate harmonic selection is time consuming and requires...
-
Ultrasonic spectroscopy of silicon single crystal
PublikacjaSpecimens of Si single crystals with different crystal orientation [100] and [110] were studied by the electro-ultrasonic spectroscopy (EUS) and Resonant Ultrasonic Spectroscopy (RUS). A silicon single crystal is an anisotropic crystal, so its properties are different in different directions in the material relative to the crystal orientation. EUS is based on interaction of two signals: electric AC signal and ultrasonic signal,...
-
Implementation of DIFAR Processing in ASW Dipping Sonar
PublikacjaThis paper presents the implementation of the signal processing algorithm used by buoy DIFAR (Directional Frequency Analysis and Recording), that is fully operational on Polish Navy anti-submarine warfare (ASW) helicopters and ships, applied to dipping sonars for detection and tracking of submarines. The development of the DSP algorithms was a part of the modernization of sonars conducted at the Gdansk University of Technology....