Filtry
wszystkich: 1836
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: TITANIUM OXIDE LAYERS
-
Evaluation of La 2 Ni 0.5 Cu 0.5 O 4+δ and Pr 2 Ni 0.5 Cu 0.5 O 4+δ Ruddlesden-Popper-type layered oxides as cathode materials for solid oxide fuel cells
Publikacja -
Wpływ procesu redukcji na właściwości strukturalne i mechaniczne szkieł tlenkowych z grupy (Pb,Bi)-(Si,Ge)-O = Influence of reduction process on the structural and mechanical properties of (Pb,Bi)-(Si,Ge)-O oxide glasses
PublikacjaThe effect of the reduction process in H2 at 380 °C on the microstructure and elemental composition of a glass Bi0.4Pb0.2Si0.4Ox has been investigated. It has been shown that after reduction a clearly separated top layer with a thickness of approx. 50 µm was formed on the surface of the sample. This layer is depleted of oxygen and has higher electrical conductivity than the interior of the glass. It has also been found that some...
-
Sol-gel derived lithium titanate powders measured by XPS method
Dane BadawczeFor sol-gel synthesis lithium acetate dehydrate from Alfa Aesar GmbH &Co and titanium (IV) butoxide 97% from Aldrich were used as reagents. Copper (II) nitrate from Alfa Aesar was used as a source of Cu dopant. It was added in the proper weight to get an x index equal 0, 0.1 and 0.2. In the first step lithium acetate and copper nitrate were dissolved...
-
Modeling DAC Application Execution Time
PublikacjaAn application written in the Divide And Conquer paradigm is more difficult to model than SPMD application because of complex algorithm, causing use of many coefficients in a computational complexity function. Processors are divided into various layers, each layer contains different number of processors. Data packets processed in different layers and transferred between layers have different length. Moreover first layer processors use...
-
Powłoki na osnowie pierwiastkowego węgla przeznaczone na implanty tytanowe
PublikacjaRozprawa miała na celu modyfikację podłoża z tytanu II oraz stopu Ti13Nb13Zr poprzez osadzenie elektroforetyczne (EPD) powłok na bazie wielościennych nanorurek węglowych (MWCNTs) z dodatkami wielkości nanometrycznej, przeznaczonych na pokrycia trzpieni endoprotez stawu biodrowego. Przygotowano trzy rodzaje powłok MWCNTs: z dodatkiem nanomiedzi (MWCNTs/Cu), nanosrebra (MWCNTs/Ag) oraz tlenku tytanu (MWCNTs/TiO2), osadzone w procesie...
-
XPS study of the lithium titanate doped by copper
Dane BadawczeLithium titanate doped by copper was measured by X-ray photoemission spectroscopy. For sol-gel synthesis lithium acetate dehydrate from Alfa Aesar GmbH &Co and titanium (IV) butoxide 97% from Aldrich were used as reagents. Copper (II) nitrate from Alfa Aesar was used as a source of Cu dopant. It was added in the proper weight to get an x index equal...
-
Maciej Jerzy Głowacki
OsobyMaciej Jerzy Głowacki jest absolwentem Politechniki Gdańskiej. Ukończył z wyróżnieniem studia inżynierskie na Wydziale Mechanicznym (2017) oraz studia magisterskie na Wydziale Elektroniki, Telekomunikacji i Informatyki (2018). Od 2014 roku jest nieprzerwanie zaangażowany w działalność badawczą prowadzoną w Katedrze Metrologii i Optoelektroniki. W pracy naukowej zajmował się m. in. nanoszeniem antybakteryjnych powłok hydroksyapatytowych...
-
The study of the influence of ZnO nanoparticles on pyocyanin production - the optimization of production and the study of the physiological response of the cells
Dane BadawczeThis dataset presents the in-depth analysis of the influence of zinc oxide nanoparticles on pyocyanin production.
-
Degradation of implantable materials – in vivo and in vitro research
PublikacjaThe article concerns the biological and electrochemical degradation of metallic implants in vivo and in vitro studies. The in vivo research dealt with degradation of plates used to join bones, as well as endoprostheses. The most common damages were: metalosis, breaking in the microstructure changes, breaking in area of holes, as well as plastic deformation throughout the length of an implant. The material used for the research...
-
Impact response of novel layered two stage fibrous composite slabs with different support type
PublikacjaThe performance of novel Layered Two Stage Fibrous Composite slabs (LTSFC) was pioneered under falling mass collisions using a combined experimental and numerical study. Such LTSFC slabs consist of three layers with and without the insertion of glass fibre mesh between the layers. LTSFC techniques were used to fabricate the composite slabs with three layers including 3%, 1.5%, and 3% of fibre content for the top, middle, and...
-
Depth profile of the gold-silver bimetallic structures
Dane BadawczeSilver and gold bimetallic layers were deposited on a silicon substrate by magnetron sputtering method. Both, Au and Ag layers had 3 nm of thickness. That prepared nanostructures were measured by XPS method. To obtain a depth profile of chemical composition, an Argon ion (Ar+) gun was used for etching surface of sample. Each cycle of etching takes 30...
-
Cavitation Erosion Resistance of Austenitic Stainless Steel after Glow-Discharge Nitriding Process
PublikacjaThis paper presents investigation of cavitation erosion resistance of nitrided austenitic stainless steel X5CrNi18-10. The diffusion layers were produced by using different parameters of atmosphere (N2:H2). The microstructure, chemical composition and phase identification of the modified layer were examined using scanning electron microscopy, glow-discharge optical emission spectrometer and X-ray diffractometry, respectively. Cavitation...
-
Evaluation of Wear Resistance of Ti alloys used for elements friction of knee endoprosthesis
PublikacjaThe paper presents research results of resistance to abrasive wear of titanium alloys: Ti6Al4V (commonly used) and Til3Nb13Zr (alloy of new generation) in association with polyethylene (UHMW-PE) predisposed for elements on pair of the knee endoprosthesis. The results were analysed from the point of possibility of an use of new generation titanium alloys as components of such implants. The tests of resistance to abrasive wear of...
-
Corrosion degradation of spacers – examination of changes in bone cement coating.
PublikacjaSpacer is a special implant used at the time of infection after endoprosthetic surgery. It consists of a metal core and bone cement coating with an antibiotic. In the human body spacers are exposed to degradation processes. This paper looks at the effect of corrosion on spacers. Electrochemical corrosion tests were performer on titanium pins with bone cement coating in two solutions: Ringer’s solution and artificial...
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublikacjaThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
Sczepność międzywarstwowa w nowobudowanych nawierzchniach w Polsce
PublikacjaW artykule przedstawiono analizę wyników badań sczepności międzywarstwowej warstw asfaltowych przeprowadzonych na podstawie danych z monitoringu właściwości fizyko-mechanicznych warstw asfaltowych z lat 2012-2013. Monitoring prowadziły Laboratoria Drogowe oddziałów GDDKiA w ramach własnych badań kontrolnych podczas realizowanych inwestycji. Analizie poddano 7043 wyników badań sczepności międzywarstwowej badanych próbek, odwierconych...
-
Chromogeniczne pochodne azoli jako składniki warstw receptorowych czujników optycznych
PublikacjaGłównym celem badań prowadzonych w ramach studium doktoranckiego była synteza oraz badanie właściwości chromogenicznych pochodnych azoli, makrocyklicznych i acyklicznych, jako składników warstw receptorowych czujników optycznych. Otrzymane związki zawierają w swojej strukturze resztę heterocykliczną – azol, który może uczestniczyć w tworzeniu kompleksów z jonami metali ciężkich oraz co najmniej jedno ugrupowanie azowe. Obecność...
-
Biocompatibility and bioactivity of bearing loaded metallic implants
PublikacjaPresentation of developed titanium alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behavior for bearing loaded implants, e.g. hip joint and knee joint endoproshtesis.
-
Ammonium <i>O</i>,<i>O</i>'-diethyl dithiophosphate
PublikacjaIn the title compound, NH4+·(C2H5O)2PS2−, the ammonium cation is connected by four charge-assisted N−H···S hydrogen bonds to four tetrahedral O,O'-diethyl dithiophosphate anions, forming layers parallel to (100). The polar and non-polar constituents of the layers are stacked alternately along [100]. Interlacing of the external ethyl groups...
-
High temperature X-Ray difractogramms of multicomponent orthoniobate
Dane BadawczeHigh-temperature XRD of calcium-doped (La0.2Nd0.2Sm0.2Gd0.2Eu0.2)1-xCaxNbO4-δ (x = 0.05) ortho-niobate. The oxide undergoes the transition between monoclinic and tetragonal structures.
-
Microstructure and Properties of Electroless Ni-P/Si3N4 Nanocomposite Coatings Deposited on the AW-7075 Aluminum Alloy
PublikacjaThe article presents the results of mechanical and tribological tests of Ni-P/Si3N4 nanocomposite coatings deposited on the AW-7075 aluminum alloy using the chemical reduction method. The influence of the chemical composition on the Vickers microhardness determined by the DSI method was examined. The nanocomposite layers were made of Si3N4 silicon nitride in a polydisperse powder with a particle size ranging from 20 to 25 nm. The...
-
Radar technique in application of interlayer identification connections
PublikacjaOne of important issues in pavement construction is to ensure that layers applied directly one on top of the other make up a continuous whole and form an integral construction complex. An appropriate interlayer connection plays here significant role ensuring proper transmission of distortions generated by wheels of vehicles to lower layers and preventing water penetration between the layers. In case of damaged pavements where lack...
-
Finite element models used in diagnostics of transverse cracks in bridge approach pavement
Dane BadawczeTransverse cracks in the asphalt pavement were observed on bridge structures next to single-module expansion joints with a 5 meter approach slab set at the depth of 1 m. The finite element (FE) models of the approach pavement were created to investigate the reasons of premature cracking and crack initiation mechanism over the back edge of the abutment...
-
Magdalena Szuflita-Żurawska
OsobyMagdalena Szuflita-Żurawska jest kierownikiem Sekcji Informacji Naukowo-Technicznej na Politechnice Gdańskiej oraz Liderem Centrum Kompetencji Otwartej Nauki przy Bibliotece Politechniki Gdańskiej. Jej główne zainteresowania badawcze koncentrują się w obszarze komunikacji naukowej oraz otwartych danych badawczych, a także motywacji i produktywności naukowej. Jest odpowiedzialna między innymi za prowadzenie szkoleń dla pracowników...
-
Nitrogen dioxide gas-sensing detection with GO modified CuO thin films
PublikacjaGas sensors have been continuously developed over the last few decades for several applications including air quality monitoring, automotive industry and recently for medical use. Gas sensors are usually based on metal oxides (MOXs), such as SnO2, TiO2, ZnO, WO3, CuO. Recently, new materials such as graphene oxide and heterostructures of graphene oxide and metal oxides are utilized for gassensing applications.
-
STUDY OF CuO AND V2O5 EFFECT ON IR SPECTRA OF POLYCRYSTALLINE BISMUTH NIOBATE
PublikacjaBismuth niobate (BiNbO4) ceramics were fabricated by mixed oxide method and sintered by presureless sintering method. BiNbO4 ceramics doped with V2O5 additive in amount 0.125 wt%, 0.250 wt% and 1 wt% of was sintered at T = 910°C whereas BiNbO4 ceramics doped with 2 wt% of CuO additive was sintered at T = 890°C and T = 910°C. It was found that V2O5 additive improved morphology of the ceramic samples. However, the chemical composition...
-
Comparison of elastic and viscoelastic analysis of asphalt pavement at high temperature
PublikacjaThere are many various rheological models which are used for modeling of asphalt layers in flexible pavement structures. It can be expected that the use of various models may affect different results of mechanical pavement calculations and analysis. The paper presents comparison of the use of Burgers’ and Huet-Sayegh’s viscoelastic models and Hooke’s elastic model to calculate pavement deflections and strains at the bottom of asphalt...
-
Properties of Barium Cerate-Zirconate Thin Films
PublikacjaIn this work, we review several experimental results showing the electrical properties of barium cerate-zirconate thin films and discuss them in view of the possible influence of various factors on their properties. Most of the presented Ba(Ce, Zr, Y)O3 thin films were formed by the pulsed laser deposition (PLD) technique, however thin films prepared using other methods, like RF magnetron sputtering, electron-beam deposition, powder...
-
Charge-based deep level transient spectroscopy of B-doped and undoped polycrystalline diamond films
PublikacjaThe undoped and B-doped polycrystalline diamond thin film was synthesized by hot filament chemical vapor deposition and microwave plasma, respectively. The structural characterization was performed by scanning electron microscopy, X-ray diffraction and Raman spectroscopy. The electrical properties of synthesized diamond layer were characterized by dc-conductivity method and charge deep level transient spectroscopy. The B-doped...
-
Network-assisted processing of advanced IoT applications: challenges and proof-of-concept application
PublikacjaRecent advances in the area of the Internet of Things shows that devices are usually resource-constrained. To enable advanced applications on these devices, it is necessary to enhance their performance by leveraging external computing resources available in the network. This work presents a study of computational platforms to increase the performance of these devices based on the Mobile Cloud Computing (MCC) paradigm. The main...
-
Biophotonic low-coherence sensors with boron-doped diamond thin layer
PublikacjaLow-coherence sensors using Fabry-Perot interferometers are finding new applications in biophotonic sensing, especially due to the rapid technological advances in the development of new materials. In this paper we discuss the possibility of using boron-doped nanodiamond layers to protect mirror in a Fabry-Perot interferometer. A low-coherence sensor using Fabry-Perot interferometer with a boron-doped nanodiamond (B-NCD) thin protective...
-
Obrony prac doktorskich na Wydziale Chemicznym
WydarzeniaDn. 26.04.2022 r. o godz. 8.30 w Audytorium 1.4 Wydziału Chemicznego PG (budynek nr 5) odbędzie się w trybie hybrydowym obrona pracy doktorskiej mgr inż. Karoliny Grajewskiej.
-
ARGENTUM Injectable nanocomposite for an instantaneous fixation of titanium implants in a bone with effective antibacterial properties
ProjektyProjekt realizowany w Zakład Technologii Biomateriałów zgodnie z porozumieniem DEC-38/2020/IDUB/I.3.3 z dnia 2020-11-17
-
X-ray diffraction spectra of modification of TiO2 nanotubes by graphene - strontium and cobalt molybdate perovskite
Dane BadawczeData show XRD results for strontium and cobalt molybdate-modified nanotubes that were also decorated with graphene oxide. The crystalline phases were characterized by X-ray diffractometer (Philips X”Pert with detector X’Celerator Scientific).
-
Application of optical microsphere in fiber optic sensors for measurement of electrochemical processes
Dane Badawczeinvestigation of the electrochemical processes using micro-sphere fiber-optic sensor with a zinc oxide (ZnO) coating applied by Atomic Layer Deposition method (ALD). The measurements were performed in 1M KNO3 during a decomposition of Bisphenol-A
-
Classification of submandibular salivary stones based on ultrastructural studies
PublikacjaIntroduction: Sialolithiasis remains a clinical problem with unclear etiopathogenesis, lack of prevention methods, and only surgical treatment. Materials and methods: An ultrastructure examination of submandibular sialoliths obtained from patients with chronic sialolithiasis was conducted using a scanning electron microscope and X‐ray photoelectron spectroscopy. Results: Based on the results, we divided sialoliths into three types:...
-
Bioactive core material for porous load-bearing implants
PublikacjaSo far state of knowledge on biodegradable materials is reviewed. Among a variety of investigated materials, those composed of polymers and ceramics may be considered as only candidates for a core material in porous titanium alloy. The collagen and chitosan among natural polymers, polyhydroxy acids among synthetic polymers, and hydroxyapatite and tricalcium phosphate among ceramics are proposed for further research. Three essential...
-
The reductivity of the transition metals - calculations
Dane BadawczeThe dataset includes the reduction enthalpy and Gibbs energy simulated for Co, Cu, Fe, La, Mo, Ni, Sr, Ti, and W from oxide form into metallic form in hydrogen. Simulations were performed using HSC Chemistry software.
-
Microwave-assisted synthesis of a TiO2-CuO heterojunction with enhanced photocatalytic activity against tetracycline
PublikacjaA microwave method was used for the synthesis of TiO2-CuO oxide systems. A detailed investigation was made of the effect of the molar ratio of components (TiO2:CuO=9:1, 7:3, 5:5, 3:7, 1:9) on the crystalline structure and morphology. Transmission electron microscopy (TEM) confirmed the presence of octahedral and rod-shaped titania particles and sheet copper(II) oxide particles; moreover, HRTEM analysis indicated the presence of...
-
Effect of Bi2O3 Excess on Morphology and Structure of BiNbO4 Ceramics
PublikacjaGoal of the present research was to fabricate BiNbO4 ceramics from the mixture of powders by the solid state reaction route and pressureless sintering at various temperatures (TS =8700C and TS =9100C) and study microstructure, phase composition and crystalline structure of BiNbO4 ceramics. Four batches were fabricated and examined, namely the one fabricated from the stoichiometric mixture of reagent – grade oxide powders, viz....
-
Deposition and Electrical and Structural Properties of La0.6Sr0.4CoO3 Thin Films for Application in High-Temperature Electrochemical Cells
PublikacjaLow-temperature deposition of electroceramic thin films allows the construction of new devices and their integration with existing large-scale fabrication methods. Developing a suitable low-cost deposition method is important to further advance the development of microdevices. In this work, we deposited a 1-lm-thick La0.6Sr0.4CoO3d (LSC) perovskite with high electrical conductivity on sapphire substrates at 400C and analyzed its...
-
Optimalization of TiO2 nanotube geometry using fuzzy reasoning approach
PublikacjaThe geometry of TiO2 nanotube layer on titanium, obtained by electrochemical anodization, has been determined by using fuzzy reasoning approach. A proposed method showed the possibility of nanotube array architecture optimization by choosing an appropriate anodization condition. A fuzzy logic controller (FLC) was utilized using Matlab Software.
-
Wpływ zawartości grafitu na właściwości mechaniczne warstw hybrydowych Ni-P/Si3N4/grafit osadzonych na stopie AW-7075 metodą redukcji chemicznej.
PublikacjaPrzedstawiono wpływ obecności grafitu jako fazy dyspersyjnej na właściwości mechaniczne warstw hybrydowych Ni-P/Si3N4/grafit, które osadzono metodą redukcji chemicznej na stopie glinu AW-7075. Wykonano badania morfologii powierzchni warstw metodą mikroskopii świetlnej i skaningowej. Dalszą część pracy stanowiły badania mechaniczne, czyli pomiary mikrotwardości warstw oraz ich adhezji do aluminiowego podłoża, a także analizy wpływu...
-
BET adsorption-desorption isotherm of nano-CeO2 impregnated with Cu
Dane BadawczeThe dataset includes the isotherms of adortion and desorption of N2 at LN2 temperature. The sorption isotherms were obtained using Quatachrome NovaTouch LX1 equippment. The catalyts powder composed of nanoCeO2 impreganted with Cu oxide nanoparticles with the usage of BCD (Beta-cyclodextrins) and without addition.
-
BET adsorption-desorption isotherm of nano-CeO2 impregnated with Co
Dane BadawczeThe dataset includes the isotherms of adortion and desorption of N2 at LN2 temperature. The sorption isotherms were obtained using Quatachrome NovaTouch LX1 equippment. The catalyts powder composed of nanoCeO2 impreganted with Co oxide nanoparticles with the usage of BCD (Beta-cyclodextrins) and without addition.
-
BET adsorption-desorption isotherm of nano-CeO2 impregnated with Mn
Dane BadawczeThe dataset includes the isotherms of adortion and desorption of N2 at LN2 temperature. The sorption isotherms were obtained using Quatachrome NovaTouch LX1 equippment. The catalyts powder composed of nanoCeO2 impreganted with Mn oxide nanoparticles with the usage of BCD (Beta-cyclodextrins) and without addition.
-
BET adsorption-desorption isotherm of nano-CeO2 impregnated with Ni
Dane BadawczeThe dataset includes the isotherms of adortion and desorption of N2 at LN2 temperature. The sorption isotherms were obtained using Quatachrome NovaTouch LX1 equippment. The catalyts powder composed of nanoCeO2 impreganted with Ni oxide nanoparticles with the usage of BCD (Beta-cyclodextrins) and without addition.
-
BET adsorption-desorption isotherm of nano-CeO2 impregnated with Fe
Dane BadawczeThe dataset includes the isotherms of adortion and desorption of N2 at LN2 temperature. The sorption isotherms were obtained using Quatachrome NovaTouch LX1 equippment. The catalyts powder composed of nanoCeO2 impreganted with Fe oxide nanoparticles with the usage of BCD (Beta-cyclodextrins) and without addition.
-
Ocena odporności na zużycie ścierne stopów Ti na elementy pary trącej endoprotez stawu kolanowego
PublikacjaNajczęściej stosowanym biomateriałem tytanowym na elementy endoprotez stawu kolanowego jest stop Ti6Al4V. Z uwagi na zawartość wanadu, zaliczanego do pierwiastków o dużej toksyczności podejmowane są działania w kierunku zastąpienia wskazanego stopu - stopami bezwanadowymi. Jednym z najbardziej obiecujących jest stop Ti13Nb13Zr zawierający w swoim składzie jedynie pierwiastki witalne, niewywołujące stanów zapalnych i odczynów...
-
Structural and Transportation Properties of Strontium Titanate Composites with Ion Conductive Oxides
PublikacjaThis paper has been written based on the author’s doctoral dissertation “Structural and transportation properties of strontium and titanate composites with ion conductive oxides”, prepared under the supervision of Prof. Dr. Hab. Eng. Bogusław Kusz at the Department of Solid State Physics of Gdańsk University of Technology. It reports the idea of the thesis and conclusions from the study. Niobium doped strontium titanate (Sr(Ti,Nb)O3)...