Filtry
wszystkich: 108
Wyniki wyszukiwania dla: METODA IMPLANT
-
Mechanics of mesh implanted into abdominal wall under repetitive load. Experimental and numerical study
PublikacjaThere are a number of papers discussing medical and mechanical aspects of ventral hernia management. Despite intensive work on the problem understanding, recurrences of the sickness still happen too often. For that reason new aspects of the problem must be considered. In this paper, a change in the abdominal implant’s stiffness is discussed, which is caused by cyclic loading. Such loading influence abdominal implant e.g. while...
-
Polynomial Chaos Expansion in Bio- and Structural Mechanics
PublikacjaThis thesis presents a probabilistic approach to modelling the mechanics of materials and structures where the modelled performance is influenced by uncertainty in the input parameters. The work is interdisciplinary and the methods described are applied to medical and civil engineering problems. The motivation for this work was the necessity of mechanics-based approaches in the modelling and simulation of implants used in the repair...
-
Investigation of abdomen surface deformation due to life excitation: implications for implant selection and orientation in laparoscopic ventral hernia repair
PublikacjaVentral hernia is a common medical problem. Statistically there are around 10% recurrences of the sickness. The authors' former investigation proved edges of the hernia orifice displacements to be one of the factors causing recurrence. Thus, experimental investigation of the abdomen surface deformation due to some normal activities of people is studied.The extreme strains, their localization and directions are identified. The acquired...
-
Is mesh fixation necessary in laparoendoscopic techniques for M3 inguinal defects? An experimental study.
Publikacjarepairs, in case of large direct hernias (M3) mesh fixation is recommended to reduce recurrence risk. Despite lack of highquality evidence, the recommendation was upgraded to strong by expert panel. The authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials. Method The authors conducted...
-
Influence of Ultrasound on the Characteristics of CaP Coatings Generated Via the Micro-arc Oxidation Process in Relation to Biomedical Engineering
PublikacjaOver the past decade, bone tissue engineering has been at the core of attention because of an increasing number of implant surgeries. The purpose of this study was to obtain coatings on titanium (Ti) implants with improved properties in terms of biomedical applications and to investigate the effect of ultrasound (US) on these properties during the micro-arc oxidation (MAO) process. The influence of various process parameters, such...
-
pH-dependent composite coatings for controlled drug delivery system - Review
PublikacjaNowadays in case of long-term implants, the most common postoperative complications are bacterial infections, which in consequence may provoke loos- ening of the implants in the primary phase of stabilization. Bacterial infections are currently the most frequent cause of revision surgery of the implants such as hip joint endoprosthesis, knee joint endoprosthesis and dental implants. In order to provide the local and long-term antibacterial...
-
Cough influence on fascia-mesh system built for a hernia repair - an experimental research
PublikacjaAn experimental approach to identify stronger and weaker fixation schemes in laparoscopic ventral hernia repair is presented in the paper. Two types of implants, whose mechanical properties are significantly different and five kinds of connectors are considered. Physical models of operated hernia have been built using those materials and porcine abdominal tissue. The models have been subjected to dynamic impulse load, similar to...
-
Investigations of Titanium Implants Covered with Hydroxyapatite Layer
PublikacjaTo reduce unfavorable phenomena occurring after introducing an implant into human body various modifications of the surface are suggested. Such modifications may have significant impact on biocompatibility of metallic materials. The titanium and it's alloys are commonly used for joint and dental implants due to their high endurance, low plasticity modulus, good corrosion resistance as well as biocompatibility. Special attention...
-
Pękanie złączy w czasie spawania i eksploatacji.
PublikacjaBadano wpływ poziomu nasycenia wodorem złączy spawanych elektrodami otulonymi na naprężenia krytyczne podczas pękania opóźnionego złączy ze stali kadłubowej. Przedstawiono możliwość określenia współczynnika intensywności naprężeń na podstawie uzyskanych wyników próby skłonności do pękania opóźnionego w próbie implant. Wartość współczynnika intensywności naprężeń określono także dla implantów jednorodnych, wykonanych z materiału...
-
Allergic reactions as a defense of the organism to the influence of implants components made of stainless steel
PublikacjaDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Allergic Reactions as a Defense of the Organism to the Influence of Implants Components Made of Stainless Steel
PublikacjaDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Pękanie opóźnione złączy spawanych
PublikacjaPrzedstawiono badania eksperymentalne i szacunki skłonności do pękania opóźnionego złączy spawanych elektrodami otulonymi EB146 na stali kadłubowej gat. AH36. Badania prowadzono przy użyciu metody kołkowej na zbudowanym, zautomatyzowanym stanowisku pomiarowym IMPLANT 02 dla elektrod generujących różne poziomy wodoru dyfundującego (2,88-15,5 mlH/100g Fe) w złączu spawanym z użyciem technologii stosowanej w przemyśle okrętowym. Wykazano...
-
Resistance to cold cracking of steel joints of P460NL1 steel
PublikacjaPrzedstawiono wyniki badań odporności na zimne pękanie złączy spawanych ze stali przeznaczonej do pracy pod ciśnieniem. Badano równoczesny wpływ zawartości wodoru dyfundującego i energii liniowej na naprężenie krytyczne w próbie implant dla złączy spawanych elektrodami otulonymi i drutem proszkowym w osłonie gazów ochronnych. Stwierdzono wpływ energii liniowej jak i zawartości wodoru dyfundującego na odporność na zimne pękanie...
-
Dynamics of mechanical model of implant-tissue system in ventral hernia repair
PublikacjaThe paper deals with a finite element modelling of implants in the problem of ventral hernia repair. The synthetic mesh implanted in the abdomen during surgery is here modelled as a membrane structure. Thesystem undergoes the internal abdominal pressure that occurs during the postoperative cough, the load identified in the literature as the main cause of the connection failure and hernia recurrence. The model can be used to estimate...
-
Kryteria oceny skłonności do pękania opóźnionego
PublikacjaPrzedstawiono wyniki badań skłonności do pękania opóźnionego określanego metodą kołkową (implant) dla złącza spawanego ręcznie elektrodami otulonymi gatunku EB146 na stali kadłubowej AH36. Określono naprężenia krytyczne i parametr pękania alfa dla kontrolowanej zawartości wodoru dyfundującego w zakresie 2,88-15,55 ml/100gFe. Wyniki badań porównano z szacunkami skłonności do pękania opartymi o metodę Ito-Besseyo i temperaturę niezbędnego...
-
Ocena kryteriów skłonności do pękania zimnego złączy spawanych.
PublikacjaPrzedstawiono wyniki badań skłonności do pękania opóźnionego określanego metodą kołkową (implant) dla złącza spawanego ręcznie elektrodami otulonymi gatunku EB146 na stali kadłubowej AH36. Określono naprężenia krytyczne dla kontrolowanej zawartości wodoru dyfundującego w zak-resie 2,88-15,55 ml/100gFe. Wyniki badań porównano z szacunkami skłonności do pękania opartymi o metodę Ito-Besseyo i temperaturę niezbędnego podgrza-nia wstępnego...
-
Stiffness change of abdominal prosthesis Optomesh™ under cyclic loading
PublikacjaAbdominal prostheses are used in humans for abdominal wall strengthening or reconstruction. From the mechanical point of view they are membranes, so their basic mechanical property is tensile stiffness. This property is experimentally identified for a selected implant, OptomeshTM. The obtained results are described herein. Uni-axial simple and cyclic tension tests are a basis for the analysis. Both kinds of tests allowed to distinguish...
-
Formation of Porous Structure of the Metallic Materials Used on Bone Implants
PublikacjaResearch on improvement of structure and fabrication methods of the bone implants are carried out for many years. Research are aimed to shape the structures, that will have a Young's modulus value similar to the value of the human bones Young's modulus. Depending on theporosity, Young's moduli can even be tailored to match the modulus of bone closer than solid metals can, thus reducing the problems associated with stress shielding...
-
Coatings in arthroplasty [online]
PublikacjaThe modern coatings used in arthroplasty for long term implants are reviewed. The phosphate coatingsare the most popular technique to improve the bone-implant interfacial strength and promote theosseointegration. The plasma spraying, electrophoretic precipitation, powder metallurgy, ion beamsputtering, high velocity oxy-fuel (HVOF) combustion spraying, sol-gel technique, biomimeticdeposition are mostly used to obtain the phosphate,...
-
Badania bioaktywności z wykorzystaniem komórek kościotwórczych na tytanie pokrytym chitozanem = Bioactivity studies using osteogenic cells on titanium coated with chitosan
PublikacjaChitosan is a natural polymer from the group of polysaccharides, which has found wide application in biomedical applications to induce bioactivity of implant. The studies described were carried out test imposition of chitosan membranes with varying degrees of deacetylation on the surface of titanium, and then check the bioactivity of the material in vitro, using osteogenic cells MC3T3-E1. Titanium surface before imposition of...
-
The determinants of morphology and properties of the nanohydroxyapatite coating deposited on the Ti13Zr13Nb alloy by electrophoretic techniqe
PublikacjaThe titanium and its alloys belong at present to the most preferred and commonly applied biomaterials for load- bearing implants. The surfaces of biomaterials are subjected to modification, including the hydroxyapatite coatings deposited in order to ensure corrosion resistance and better joining between an implant and a bone through the possibility of ingrowth bone into the coating. In this paper, the morphology and properties...
-
Graphene Production and Biomedical Applications: A Review
PublikacjaGraphene is a two-dimensional nanomaterial composed of carbon atoms with sp2 hybrid orbitals. Both graphene and graphene-based composite have gained broad interest among researchers because of their outstanding physiochemical, mechanical, and biological properties. Graphene production techniques are divided into top-down and bottom-up synthesis methods, of which chemical vapor deposition (CVD) is the most popular. The biomedical...
-
Global sensitivity analysis of membrane model of abdominal wall with surgical mesh
PublikacjaThe paper addresses the issue of ventral hernia repair. Finite Element simulations can be helpful in the optimization of hernia parameters. A membrane abdominal wall model is proposed in two variants: a healthy one and including hernia defect repaired by implant. The models include many uncertainties, e.g. due to variability of abdominal wall, intraabdominal pressure value etc. Measuring mechanical properties with high accuracy...
-
The Effect of Surface Modification of Ti13Zr13Nb Alloy on Adhesion of Antibiotic and Nanosilver-Loaded Bone Cement Coatings Dedicated for Application as Spacers
PublikacjaSpacers, in terms of instruments used in revision surgery for the local treatment of postoperative infection, are usually made of metal rod covered by antibiotic-loaded bone cement. One of the main limitations of this temporary implant is the debonding effect of metal–bone cement interface, leading to aseptic loosening. Material selection, as well as surface treatment, should be evaluated in order to minimize the risk of fraction...
-
Wpływ warunków spawania na skłonność do tworzenia pęknięć zimnych przy spawaniu pod wodą
PublikacjaPrzedmiotem pracy było określenie skłonności do tworzenia pęknięć zimnych złączy spawanych ze stali 18G2A wykonanych pod wodą metodą lokalnej komory suchej. Problem rozwiązano przy zastosowaniu teorii planowania badań. Określono ilościowy wpływ parametrów spawania: wydatku gazu osłonowego oraz energii liniowej spawania na naprężenia krytyczne z próby implant, wskaźnik skłonności do tworzenia pęknięć zimnych, twardość maksymalną...
-
Recent advances in electrochemically surface treated titanium and its alloys for biomedical applications: A review of anodic and plasma electrolytic oxidation methods
PublikacjaNowadays, titanium and its alloys are widely used materials in implantology. Nevertheless, the greatest challenge is still its appropriate surface treatment in order to induce optimal properties, which facilitates formation of a permanent bond between the implant and human tissue. The use of electrochemical treatment such as anodic oxidation or plasma electrolytic oxidation allows for the production of porous coating that mimics...
-
Titania Nanotubes/Hydroxyapatite Nanocomposites Produced with the Use of the Atomic Layer Deposition Technique: Estimation of Bioactivity and Nanomechanical Properties
PublikacjaTitanium dioxide nanotubes/hydroxyapatite nanocomposites were produced on a titanium alloy (Ti6Al4V/TNT/HA) and studied as a biocompatible coating for an implant surface modification. As a novel approach for this type of nanocomposite fabrication, the atomic layer deposition (ALD) method with an extremely low number of cycles was used to enrich titania nanotubes (TNT) with a very thin hydroxyapatite coating. X-ray diffraction (XRD)...
-
EXAMINATION OF SOL-GEL DERIVED HYDROXYAPATITE ENHANCED WITH SILVER NANOPARTICLES USING OCT AND RAMAN SPECTROSCOPY
PublikacjaHydroxyapatite (HAp) has been attracting widespread interest in medical applications. In a form of coating, it enables to create a durable bond between an implant and surrounding bone tissues. With addition of silver nanoparticles HAp should also provide antibacterial activity. The aim of this research was to evaluate the composition of hydroxyapatite with silver nanoparticles in a non-destructive and non-contact way. For control measurements...
-
Effect of double thermal and electrochemical oxidation on titanium alloys for medical applications
PublikacjaThe research focuses on the development and characterization of innovative thin hybrid oxide coatings obtained in subsequent processes of thermal (TO) and electrochemical (EO) oxidation. Four different surface modifications were investigated and the microstructure was determined, the mechanical, chemical and biological properties of the Ti-13Nb-13Zr alloy were assessed using scanning electron microscopy, X-ray dispersion analysis,...
-
A Probe into the Corrosion Behavior of a WE43B Magnesium Alloy in a Simulated Body Fluid using Dynamic Electrochemical Impedance Spectroscopy
PublikacjaWE43B is one of the newest Mg alloys with practical application in biomedical implant technology. This work attempts to scrutinize the corrosion characteristics of WE43B alloy in a simulated body fluid (SBF) at a typical body temperature. The dynamic-electrochemical impedance spectroscopy with the capacity to track changes on surfaces in a dynamic corrosive system is used in combination with other classical techniques namely, linear...
-
Degradation of implantable materials – in vivo and in vitro research
PublikacjaThe article concerns the biological and electrochemical degradation of metallic implants in vivo and in vitro studies. The in vivo research dealt with degradation of plates used to join bones, as well as endoprostheses. The most common damages were: metalosis, breaking in the microstructure changes, breaking in area of holes, as well as plastic deformation throughout the length of an implant. The material used for the research...
-
Introduction to the RSC Advances themed collection on nano and microscale modifications of biomaterials
PublikacjaThe dramatically increasing development of novel biomaterials, their manufacturing techniques, and surface modications, as well as their application in in vivo tests and clinical trials, is evident. It is interesting to note in what a relatively short time the well-known long-term implants have become medical standard: titanium dental implants started in 1965, and total hip arthroplasty (not very successful) was rst attempted...
-
High meniscal slope angle as a risk factor for meniscal allograft extrusion
PublikacjaA meniscal graft extrusion is still an unresolved problem that affects most patients after a meniscal transplantation. Despite the advances in surgical techniques, together with the improved methods for a meniscal allograft sizing, success is only observed in up to 75% of patients after they experience a meniscal allograft transplantation. Because a meniscal extrusion is associated with a cartilage deterioration and the progression...
-
Antimicrobal and ostheointegration activity of bone cement contains nanometals
PublikacjaPurpose: One of the major problems in bone surgery are infections – especially thoseoccurring in the course of the operating on the patients with lowered immunity system,because they carry the danger of complications. In the Mechanical Department of TechnicalUniversity of Gdansk, there has been carried the research with the use of bone cement andmetal nanoparticles.Design/methodology/approach: The bone cement was used without supplement...
-
Corrosion degradation of spacers – examination of changes in bone cement coating.
PublikacjaSpacer is a special implant used at the time of infection after endoprosthetic surgery. It consists of a metal core and bone cement coating with an antibiotic. In the human body spacers are exposed to degradation processes. This paper looks at the effect of corrosion on spacers. Electrochemical corrosion tests were performer on titanium pins with bone cement coating in two solutions: Ringer’s solution and artificial...
-
Sensitivity analysis based on non-intrusive regression-based polynomial chaos expansion for surgical mesh modelling
PublikacjaThe modelling of a system containing implants used in ventral hernia repair and human tissue suffers from many uncertainties. Thus, a probabilistic approach is needed. The goal of this study is to define an efficient numerical method to solve non-linear biomechanical models supporting the surgeon in decisions about ventral hernia repair. The model parameters are subject to substantial variability owing to, e.g., abdominal wall...
-
Biomechanical testing of bioactive bone cements – a comparison of the impact of modifiers: antibiotics and nanometals
PublikacjaApart from its bone filler and fracture stabilizing function, bone cement can be used as a carrier of bioactive substances, and such modified bone cement can protect the implant against microorganisms, treat local infections and combat bacteria introduced during the surgical procedure. In this paper, the effects of modifying antibiotics and nanosilver on the biomechanical properties of bone cement were examined. The following tests...
-
Assessment of the usefulness of bacterial cellulose produced by Gluconacetobacter xylinus E25 as a new biological implant
PublikacjaBionanocellulose (BNC) is a clear polymer produced by the bacterium Gluconacetobacter xylinus. In our current study, “Research on the use of bacterial nanocellulose (BNC) in regenerative medicine as a function of the biological implants in cardiac and vascular surgery”, we carried out material analysis, biochemical analysis, in vitro tests and in vivo animal model testing. In stage 1 of the project, we carried out physical and...
-
Antibacterial Activity and Cytocompatibility of Bone Cement Enriched with Antibiotic, Nanosilver, and Nanocopper for Bone Regeneration
PublikacjaBacterial infections due to bone replacement surgeries require modifications of bone cement with antibacterial components. This study aimed to investigate whether the incorporation of gentamicin or nanometals into bone cement may reduce and to what extent bacterial growth without the loss of overall cytocompatibility and adverse effects in vitro. The bone cement Cemex was used as the base material, modified either with gentamicin...
-
The Effect of Marginal Zn2+ Excess Released from Titanium Coating on Differentiation of Human Osteoblastic Cells
PublikacjaComposite coatings based on chitosan and zinc nanoparticles (ZnNPs) were successfully produced on Ti13Zr13Nb substrates by cathodic electrophoretic deposition (EPD). The unfavorable phenomenon of water electrolysis-induced nonuniformity was reduced by applying a low voltage (20 V) and a short deposition time (1 min). Surface analysis (roughness and hydrophilicity) reveals the potential of these coatings for enhancing cell attachment...
-
In vivo performance of intraperitoneal onlay mesh after ventral hernia repair
PublikacjaBackground: Ventral hernia repair needs to be improved since recurrence, postoperative pain and other complications are still reported in many patients. The behavior of implants in vivo is not sufficiently understood to design a surgical mesh mechanically compatible with the human abdominal wall. Methods: This analysis was based on radiological pictures of patients who underwent laparoscopic ventral hernia repair. The pictures...
-
Problematyka implantacji protez piersiowych - przegląd literatury
PublikacjaOperacje związane z wykorzystaniem implantów piersi są jednymi z najczęściej przeprowadzanych zabiegów chirurgii plastycznej, dlatego istotne jest, aby zminimalizować ryzyko powikłań. Do najczęściej występujących zalicza się: obrzęk, wysięk, krwiaki, problemy z gojeniem ran oraz infekcje. Zakłada się, że infekcja jest głównym czynnikiem prowadzącym do degradacji implantu. Agresywne środowisko gospodarza, ciągłe zmiany pH i temperatury...
-
Investigation on Filaments for 3D Printing of Nasal Septum Cartilage Implant
PublikacjaSeptoplasty is a widely used method in treating deviated septum. Although it is successfully implemented, there are problems with excessive bleeding, septal perforation, or infections. The use of anatomically shaped implants could help overcome these problems. This paper focuses on assessing the possibility of the usage of a nasal septum cartilage implant 3D printed from various market-available filaments. Five different types...
-
Properties of New Composite Materials Based on Hydroxyapatite Ceramic and Cross-Linked Gelatin for Biomedical Applications
PublikacjaThe main aim of the research was to develop a new biocompatible and injectable composite with the potential for application as a bone-to-implant bonding material or as a bone substitute. A composite based on hydroxyapatite, gelatin, and two various types of commercially available transglutaminase (TgBDF/TgSNF), as a cross-linking agent, was proposed. To evaluate the impacts of composite content and processing parameters on various...
-
Research of chitosan coatings deposited by electrophoretic deposition method at various voltage and time parameters
PublikacjaThe aim of this research is to estimate the electrophoretic deposition main parameters, such as voltage and time duration, that will provide optimal characteristics of the surface layer. Chitosan coatings were synthesized on biomedical Ti13Zr13Nb alloys at 20 V and 30 V and with deposit times of 2min, 5 min, 10 min, and 15 min. Evaluation of the coating was performed by using Scanning Electron Microscope (SEM), Energy-Dispersive...
-
Comprehensive Evaluation of the Biological Properties of Surface-Modified Titanium Alloy Implants
PublikacjaAn increasing interest in the fabrication of implants made of titanium and its alloys results from their capacity to be integrated into the bone system. This integration is facilitated by different modifications of the implant surface. Here, we assessed the bioactivity of amorphous titania nanoporous and nanotubular coatings (TNTs), produced by electrochemical oxidation of Ti6Al4V orthopedic implants’ surface. The chemical composition...
-
The mechanisms of degradation of titanium dental implants
PublikacjaTitanium dental implants show very good properties, unfortunately there are still issues regarding material wear due to corrosion, implant loosening, as well as biological factors—allergic reactions and inflammation leading to rejection of the implanted material. In order to avoid performing reimplantation operations, changes in the chemical composition and/or modifications of the surface layer of the materials are used. This research...
-
Green engineered biomaterials for bone repair and regeneration: Printing technologies and fracture analysis
PublikacjaDespite the exceptional self-regeneration properties of bone, severe injuries often require additional surgical intervention such as using artificial bone constructs. These structures need to meet a number of criteria regarding their structure, performance, alongside the rate and the mechanism of erosion and fracture when implanted, for stimulating the regeneration of defected bone and, more critically providing support in the...
-
Mechanical behaviour of knit synthetic mesh used in hernia surgery
PublikacjaPurpose: There is a discussion in literature concerning mechanical properties and modelling of surgical meshes. An important feature of elastic modulus dependency on load history is taken into account in this paper, as implants are subjected to variable loading during human activity. The example of DynaMesh®-IPOM surgical implant is studied. Methods: The analysis is based on failure tension tests and cyclic loading and unloading...
-
Mechanical Properties and Residual Stress Measurements of Grade IV Titanium and Ti-6Al-4V and Ti-13Nb-13Zr Titanium Alloys after Laser Treatment
PublikacjaNowadays, surface engineering focuses on research into materials for medical applications. Titanium and its alloys are prominent, especially Ti-6Al-4V and Ti-13Nb-13Zr. Samples made of pure grade IV titanium and the titanium alloys Ti-6Al-4V and Ti-13Nb-13Zr were modified via laser treatment with laser beam frequency f = 25 Hz and laser beam power P = 1000 W during a laser pulse with duration t = 1 ms. Subsequently, to analyze...