Filtry
wszystkich: 264
-
Katalog
Wyniki wyszukiwania dla: gębicki jacek
-
Analysis of odor interactions in ternary gas mixtures using electronic nose
PublikacjaIn recent years there has been a noticeable increase in interest in the use of electronic noses in analytical chemistry. These devices perform a holistic analysis of the gas mixtures composition, without the separation and identification of its individual components. For this reason e-noses are increasingly replacing the conventional olfactometers, due to the significantly shorter analysis time and possible automation. In the work...
-
Determination of Odour Interactions of Three-Component Gas Mixtures Using an Electronic Nose
PublikacjaThe paper presents an application of an electronic nose prototype comprised of six TGS-type sensors and one PID-type sensor to identify odour interaction phenomena in odorous three-component mixtures. The investigation encompassed eight odorous mixtures—toluene-acetone-triethylamine and formaldehyde-butyric acid-pinene — characterized by different odour intensity and hedonic tone. A principal component regression (PCR) calibration...
-
Monitoring and efficiency assessment of biofilter air deodorization using electronic nose prototype
PublikacjaBiofiltration is one of the techniques used to reduce odorants in the air. It is based on the aerobic degradation of pollutants by microorganisms located in the filter bed. The research presents the possibility of using the electronic nose prototype for monitoring and efficiency assessment of air biofiltration. The study was conducted using model gas mixtures containing representatives of three groups of chemical compounds: n-hexane...
-
Application of fuzzy logic to determine the odour intensity of model gas mixtures using electronic nose
PublikacjaThe paper presents the possibility of application of fuzzy logic to determine the odour intensity of model, ternary gas mixtures (α-pinene, toluene and triethylamine) using electronic nose prototype. The results obtained using fuzzy logic algorithms were compared with the values obtained using multiple linear regression (MLR) model and sensory analysis. As the results of the studies, it was found the electronic nose prototype along...
-
Quality evaluation of agricultural distillates using different types of electronic noses
PublikacjaThe paper presents the results of investigation on quality evaluation of agricultural distillates using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with TGS type semiconductor sensors. HERACLES II included two chromatographic columns with different polarity of stationary phase and two FID detectors. In case of the prototype volatile fraction...
-
Comparison of different types of electronic nose instruments for evaluation of odour nuisance from landfill
PublikacjaThe paper presents and compares the results of investigation on classification of atmospheric air samples collected in a vicinity of municipal landfill with respect to their odour nuisance. The research was conducted using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with six semiconductor sensors of TGS type. Classification of the air...
-
Comparison of Quality Evaluation of Agricultural Distillates Using Prototype of Electronic Nose and Fast/Flash GC
PublikacjaThe paper presents the results of investigation on quality evaluation of agricultural distillates using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co.. In case of the prototype volatile fraction of the agricultural distillate was prepared via barbotage process. HERACLES II analysed the...
-
Monitoring of Odour Nuisance from Landfill Using Electronic Nose
PublikacjaThe paper presents the results of investigation on classification of atmospheric air samples collected in a vicinity of municipal landfill with respect to their odour nuisance. The research was conducted using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type –HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co.. Classification of the air samples...
-
Studies on origin of Polish honeys by two-dimensional gas chromatography Ocena pochodzenia surowcowego polskich miodów przy użyciu dwuwymiarowej chromatografii gazowej
PublikacjaPolish acacia, linden, rapessed and buckwheat-derived honeys and a honydew were analysed for presence of hydrocarbons, alcs., ketones and esters by 2-dimensional gas chromatog. to establish the markers for the honey origin. PrOH was found characteristic for acacia honey, Me(CH2)11OH for linden honey, Me(CH2)6CHOMe for honeydew and Me(CH2)8COOEt for the rapeseed honey. Wykorzystano technikę dwuwymiarowej chromatografii gazowej sprzężonej...
-
ODOUR IMPACT OF MUNICIPAL LANDFILL MONITORED WITH ULTRA-FAST GAS CHROMATOGRAPHY = ODDZIAŁYWANIE ZAPACHOWE SKŁADOWISKA ODPADÓW KOMUNALNYCH MONITOROWANE ZA POMOCĄ ULTRA SZYBKIEJ CHROMATOGRAFII GAZOWEJ
PublikacjaPrzedstawiono wyniki badań klasyfikacji próbek powietrza atmosferycznego pobranych wokół miejskiego składowiska odpadów komunalnych w okresie zimowym i letnim pod kątem uciążliwości zapachowej. Badania przeprowadzono przy pomocy komercyjnego elektronicznego nosa typu Fast/Flash GC - HERACLES II. Klasyfikację próbek powietrza atmosferycznego pobranych z różnych kierunków względem wysypiska śmieci przeprowadzano przy użyciu dyskryminacyjnej...
-
Use of electronic nose for quality assessment of agricultural ethanol distillates Wykorzystanie elektronicznego nosa do oceny jakości etanolowych destylatów rolniczych
PublikacjaPrzedstawiono wyniki badań oceny jakości destylatów rolniczych za pomocą prototypu elektronicznego nosa, wyposażonego w zestaw 6 półprzewodnikowych czujników. Frakcję lotną próbek destylatu rolniczego wytwarzano za pomocą procesu barbotażu. Klasyfikację próbek do odpowiedniej klasy jakości, przeprowadzano przy użyciu funkcji dyskryminacyjnych: liniowej i kwadratowej wspartej metodą kroswalidacji. Na podstawie przeprowadzonych...
-
OCENA JAKOŚCI DESTYLATÓW ROLNICZYCH WYKONANYCH ZA POMOCĄ PROTOTYPU ELEKTRONICZNEGO NOSA I FAST/FLASH GC
PublikacjaPrzedstawiono wyniki badań oceny jakości destylatów rolniczych przy pomocy prototypu elektronicznego nosa i komercyjnego elektronicznego nosa typu Fast/Flash GC - HERACLES II. Prototyp był wyposażony w zestaw sześciu półprzewodnikowych czujników firmy FIGARO. HERACLES II wyposażony był w dwie kolumny chromatograficzne z różną polarnością fazy stacjonarnej oraz dwa detektory FID. Frakcję lotną próbek destylatu rolniczego wytwarzano...
-
UCIĄŻLIWOŚĆ ZAPACHOWA Z WYSYPISKA ŚMIECI MONITOROWANA ZA POMOCĄ RÓŻNYCH TYPÓW ELEKTRONICZNEGO NOSA
PublikacjaPrzedstawiono wyniki badań klasyfikacji próbek powietrza atmosferycznego pobranych wokół miejskiego wysypiska śmieci pod kątem uciążliwości zapachowej. Badania przeprowadzono przy pomocy prototypu elektronicznego nosa i komercyjnego elektronicznego nosa typu Fast/Flash GC - HERACLES II. Prototyp był wyposażony w zestaw sześciu półprzewodnikowych czujników firmy FIGARO. Klasyfikację próbek powietrza w zależności od kierunku pobrania...
-
Measurement techniques for assessing the olfactory impact of municipal sewage treatment plants
PublikacjaThe study presents information about the measurement techniques used for the assessment of air quality in terms of the olfactory intensity resulting from the operation of municipal sewage treatment plants. Advantages and disadvantages of the measurement techniques used are presented. Sources of malodourous substance emission from sewage treatment plants were described, and the malodourous substances emitted were characterised....
-
Technologies for deodorization of malodorous gases
PublikacjaThere is an increasing number of citizens’complaints about odor nuisance due to production or service activity. High socialawareness imposes pressure on entrepreneurs and service providers forcing them to undertake effective steps aimed at minimi-zation of the effects of their activity, also with respect to emission of malodorous substances. The article presents informationabout various technologies used for gas deodorization....
-
Evaluation of Health Hazard Due to Emission of Volatile Organic Compounds from Various Processing Units of Wastewater Treatment Plant
PublikacjaThe paper describes an attempt at health risk assessment and odour concentration determination in the most important units of a wastewater treatment plant. The cancer risk (CR) and hazard index (HI) parameters in selected measurement locations were calculated based on the results of chromatographic analyses (GCxGC-TOF-MS) and the United States Environmental Protection Agency (US EPA) guidelines. No exceedance of the CR and HI acceptable...
-
Analysis of odour interactions in model gas mixtures using electronic nose and fuzzy logic
PublikacjaMeasurement and monitoring of air quality in terms of odour nuisance is an important problem. Although the source of these nuisances is different (e.g. wastewater treatment plants, municipal landfills), their common feature is that they are a complex mixture of odorants with different odour thresholds. An additional problem is occurrence of the odour interactions between mixture components. From a practical point of view, it would...
-
Sorbents modified by deep eutectic solvents in microextraction techniques
PublikacjaIn recent years, considerable attention has been directed towards the employment of green solvents, specifically deep eutectic solvents (DES), in liquid phase microextraction techniques. However, comprehensive and organized knowledge regarding the modification of sorbent surface structures with DES remains limited. Therefore, this paper reviews the application of DES in modifying and improving the properties of sorbents for microextraction...
-
Równoważność metod pomiarowych ciągłych i odniesienia stosowanych do oznaczania pm10
PublikacjaW pracy przedstawiono wyniki testu terenowego przeprowadzonego na terenie Gdańska w okresie od 01-01-2010 do 31-12-2010 i od 01-01-2011 do 31-12-2011 w celu wykazania równoważności wskazań analizatora Eberline FH 62-1 w stosunku do wagowej metody odniesienia. Przedyskutowano występowanie różnic wskazań wartości stężeń pyłu PM10 w zależności od pory roku dla obu metod pomiarowych. Przedstawiono sposób określania równoważności tych...
-
Quality Evaluation of Agricultural Distillates Using an Electronic Nose
PublikacjaThe paper presents the application of an electronic nose instrument to fast evaluation of agricultural distillates differing in quality. The investigations were carried out using a prototype of electronic nose equipped with a set of six semiconductor sensors by FIGARO Co., an electronic circuit converting signal into digital form and a set of thermostats able to provide gradient temperature characteristics to a gas mixture. A volatile fraction...
-
The Use of Sensory Analysis Techniques to Assess the Quality of Indoor Air
PublikacjaThe quality of indoor air is one of the significant elements that influences people's well-being and health inside buildings. Emissions of pollutants, which may cause odor nuisance, are the main reason for people's complaints regarding the quality of indoor air. As a result, it is necessary to perform tests aimed at identifying the sources of odors inside buildings. The article contains basic information on the characteristics...
-
Monitoring of odour nuisance on the adjacent areas to the landfill using fast GC and sensory analysis
PublikacjaThe paper shows the results of investigation on classification of the atmospheric air samples collected in a vicinity of the landfill during August and September period have been presented. The studies was conducted by the use of Fast GC HERACLES II from AlphaMOS company and sensory analysis. About 86% of the atmospheric air samples ollected were classified correctly using PCA and LDA. Based on a classification of the atmospheric...
-
Direct Analysis of Samples of Various Origin and Composition Using Specific Types of Mass Spectrometry
PublikacjaOne of the major sources of error that occur during chemical analysis utilizing the more conventional and established analytical techniques is the possibility of losing part of the analytes during the sample preparation stage. Unfortunately, this sample preparation stage is required to improve analytical sensitivity and precision. Direct techniques have helped to shorten or even bypass the sample preparation stage; and in this...
-
Electronic Noses in Medical Diagnostics
PublikacjaElectronic nose technology is being developed in order to identify aromas in a way parallel to the biologic olfaction. When applied to the field of medicine, such device should be able to identify and discriminate between different diseases. In recent years this kind of approach finds application in medical diagnostics, and especially in disease screening. Despite the fact that devices utilizing chemical sensor arrays are not routinely...
-
Determination of Odour Interactions in Gaseous Mixtures Using Electronic Nose Methods with Artificial Neural Networks
PublikacjaThis paper presents application of an electronic nose prototype comprised of eight sensors, five TGS-type sensors, two electrochemical sensors and one PID-type sensor, to identify odour interaction phenomenon in two-, three-, four- and five-component odorous mixtures. Typical chemical compounds, such as toluene, acetone, triethylamine, α-pinene and n-butanol, present near municipal landfills and sewage treatment plants were subjected...
-
Instrumental measurement of odour nuisance in city agglomeration using electronic nose
PublikacjaThe paper describes an operation principle of odour nuisance monitoring network in a city agglomeration. Moreover, it presents the results of investigation on ambient air quality with respect to odour obtained during six-month period. The investigation was carried out using a network comprised of six prototypes of electronic nose and Nasal Ranger field olfactometers employed as a reference method. The monitoring network consisted...
-
Complementary use of GCxGC–TOF–MS and statistics for differentiation of variety in biosolid samples
PublikacjaFormation of biosolid cakes, which are one of the main wastes generated in wastewater treatment plants, is connected with emission of many hazardous chemical compounds, including odoriferous ones. To optimize particular processes of biosolid cake processing, it is necessary to assess chemical composition of the gas mixtures containing the compounds released from the cakes. The paper proposes application of two-dimensional gas chromatography...
-
Devices for the production of reference gas mixtures
PublikacjaFor many years there has been growing demand for gaseous reference materials, which is connected with development in many fields of science and technology. As a result, new methodological and instrumental solutions appear that can be used for this purpose. Appropriate quality assurance/quality control (QA/QC) must be used to make sure that measurement data are a reliable source of information. Reference materials are a significant...
-
Urządzenia do wytwarzania gazowych mieszanin wzorcowych
PublikacjaW ostatnich latach obserwuje się zwiększone zainteresowanie kontrolą jakości powietrza atmosferycznego wewnętrznego oraz atmosfery na stanowiskach pracy. Nieocenioną rolę dla tego w typu działań odgrywają materiały odniesienia. W tym artykule przedstawiono zastosowanie gazowych mieszanin wzorcowych, które są specyficznym rodzajem materiałów odniesienia, oraz opisano metody ich otrzymywania. Dokonano również charakterystyki rozwiązań...
-
Urządzenie do wytwarzania gazowych mieszanin wzorcowych z wykorzystaniem procesu barbotażu oraz permeacji
PublikacjaReference gas mixtures are classified to reference materials and are mainly used for quality monitoring and identification of impurities in atmospheric air. They can be also used for calibration of measuring devices. Nowadays, there is a need to develop a new techniques for the preparation of reference gas mixtures [1, 2]. In this paper the design and the operating principles of instrument based on the use of barbotage and permeation...
-
Application of an Electronic Nose Instrument to Fast Classification of Polish Honey Types
PublikacjaThe paper presents practical utilization of an electronic nose prototype, based on the FIGARO semiconductor sensors, in fast classification of Polish honey types—acacia flower, linden flower, rape, buckwheat and honeydew ones. A set of thermostating modules of the prototype provided gradient temperature characteristics of barbotage-prepared gas mixtures and stable measurement conditions. Three chemometric data analysis methods...
-
Bezpośrednia analiza próbek z wykorzystaniem techniki spektrometrii mas. Cz. I. Rozwiązania metodyczne w zakresie spektrometrii mas umożliwiające bezpośrednią analizę próbek
PublikacjaTechnika spektrometrii mas stanowi jedno z najważniejszych narzędzi analitycznych, wykorzystywanych do identyfikacji, określania struktury chemicznej oraz oznaczania stężeń wielu związków chemicznych. Aby zidentyfikować obecne w próbkach rzeczywistych anality, konieczne jest jednak z reguły ich wstępne rozdzielenie, toteż spektrometry mas pełnią najczęściej rolę detektora np. w przypadku technik łączonych, gdy na etapie rozdzielania...
-
Bezpośrednia analiza próbek z wykorzystaniem techniki spektrometrii mas. Cz. II. Technika PTR – MS – ciekawe rozwiązanie metodyczne w zakresie spektrometrii mas
PublikacjaTechnika spektrometrii mas stanowi niezwykle istotne narzędzie badawcze, umożliwiające uzyskanie wielu cennych informacji, dotyczących składu chemicznego wielu próbek rzeczywistych pochodzenia biologicznego, farmaceutycznego i spożywczego. Spektrometr mas zazwyczaj pełni role detektora w przypadku stosowania połączenia z urządzeniami chromatograficznymi (GC, LC). Dzięki zastosowaniu pewnych modyfikacji aparaturowych i metodycznych,...
-
Wykorzystanie substancji znacznikowych w badaniach stanu środowiska
PublikacjaMonitoring środowiska stanowi jeden z głównych obszarów analityki chemicznych, którego rozwój obserwuje się na przestrzeni ostatnich lat. Dzięki temu możliwe jest rozwiązywanie problemów związanych ze zmianami zachodzącymi w różnych ekosystemach z uwzględnieniem poszanowania środowiska. Jedną z form uzyskiwania miarodajnych informacji na temat stanu środowiska może być stosowanie substancji znacznikowych, których stosowanie umożliwia...
-
Determination of Odor Air Quality Index (OAQII) Using Gas Sensor Matrix
PublikacjaThis article presents a new way to determine odor nuisance based on the proposed odor air quality index (OAQII), using an instrumental method. This indicator relates the most important odor features, such as intensity, hedonic tone and odor concentration. The research was conducted at the compost screening yard of the municipal treatment plant in Central Poland, on which a self-constructed gas sensor array was placed. It consisted...
-
Alternative methods for dark fermentation course analysis
PublikacjaDark fermentation course analysis is crucial, as complexed matrix of gaseous components may be formed and revealed during the process. The paper considers key issues related to the microbiological process in which complex organic substances are transformed into hydrogen. For the purposes of hydrogen generation, the application of wastewater mixed sludge pre-treated according to Faloye method (Faloye et al. in Int J Hydrog Energy...
-
Pyrolysis Combined with the Dry Reforming of Waste Plastics as a Potential Method for Resource Recovery—A Review of Process Parameters and Catalysts
Publikacja: Emissions of greenhouse gases and growing amounts of waste plastic are serious environmental threats that need urgent attention. The current methods dedicated to waste plastic recycling are still insufficient and it is necessary to search for new technologies for waste plastic management. The pyrolysis-catalytic dry reforming (PCDR) of waste plastic is a promising pro-environmental way employed for the reduction of both CO2 and...
-
Application of a Gas Sensor Array to Effectiveness Monitoring of Air Contaminated with Toluene Vapors Absorption Process
PublikacjaThis article demonstrates the application of a gas sensor array to monitor the effectiveness of the absorption process of air stream purification from odorous compounds (toluene vapors). A self-constructed matrix consisting of five commercially available gas sensors was used. Multiple linear regression (MLR) was selected as the statistical technique used to calibrate the matrice. Gas chromatography coupled with a flame ionization...
-
Spatial aspects of urban air quality management: Estimating the impact of micro-scale urban form on pollution dispersion
PublikacjaUrban planning and design solutions affect urban ventilation conditions, thus mitigating the effects of atmospheric pollution. However, these findings are not being implemented in the planning practice to a sufficient extent, partly due to the lack of specific guidelines. Moreover, many urban air quality monitoring (AQM) sites have low represnentativeness and thus do not provide comprehensive data for effective urban air pollution control...
-
Processing of Biomass Prior to Hydrogen Fermentation and Post-Fermentative Broth Management
PublikacjaUsing bioconversion and simultaneous value-added product generation requires purifica- tion of the gaseous and the liquid streams before, during, and after the bioconversion process. The effect of diversified process parameters on the efficiency of biohydrogen generation via biological pro- cesses is a broad object of research. Biomass-based raw materials are often applied in investigations regarding biohydrogen generation using...
-
Bio-inspired approaches for explosives detection
PublikacjaDue to unique abilities of the animals regarding analysis of complex gas substances, they still remain a gold standard in analysis of explosives. Unusual capabilities of biological chemosensory systems, including both vertebrates and invertebrates, stimulate elaboration of the devices mimicking their activity and operation parameters as precisely as possible. The electronic analogues are a subject of investigation in many research...
-
Electrochemical sensor for measurement of volatile organic compounds in air
PublikacjaPrzedstawiono rezultaty badań prototypowego czujnika do oznaczania mrówczanu etylu i formaldehydu w powietrzu. Określono czułość wskazań czujnika i jego granice oznaczalności wykorzystując jako techniki detekcyjne pulsową woltamperometrię różnicową (DPV) oraz woltamperometrię fali prostokątnej (SWV). Elektrodę roboczą i przeciwelektrodę stanowiły elektrody z Pt. Elektrolitem wewnętrznym była ciecz jonowa (chlorek 1-heksylo,3-metyloimidazolinowy)....
-
Microplastics removal from aqueous environment by metal organic frameworks
PublikacjaThis paper provides an overview of recent research performed on the applications of metal–organic frameworks (MOFs) for microplastics (MPs) removal from aqueous environments. MPs pollution has become a major environmental concern due to its negative impacts on aquatic ecosystems and human health. Therefore, developing effective and sustainable methods for removing them from aqueous environments is crucial. In recent years, MOFs...
-
Ocena skuteczności usuwania wybranych związków odorowych z powietrza z wykorzystaniem biofiltra ze złożem zraszanym
PublikacjaW pracy omówiono najczęściej stosowane metody dezodoryzacji powietrza, zwracając uwagę na zróżnicowane właściwości chemiczne różnych grup związków zapachowych. Omówiono techniki biofiltracyjne, wskazując aktualne trendy rozwojowe. Przedstawiono wyniki badań dotyczących jednoczesnego usuwania (a)-pinenu i cykloheksanu, uzyskując wartości stopnia usunięcia wymienionych związków powyżej 80%.
-
Zastosowanie niskokosztowych czujników PM10 do monitoringu jakości powietrza atmosferycznego
PublikacjaW pracy przedstawiono wyniki testu terenowego przeprowadzonego na terenie Gdańska w okresie od 7 do 24 lutego 2018 w celu wykazania wiarygodności uzyskiwanych wyników za pomocą komercyjnych czujników PM10 działających na zasadzie laserowego licznika cząstek w stosunku do metody odniesienia.
-
Monitoring of n-butanol vapors biofiltration process using an electronic nose combined with calibration models
PublikacjaMalodours, by definition, are generally unpleasant, nuisance smells that are a mixture of volatile chemical compounds which can be perceptible even at low concentrations. Due to the more frequent occurrence of odour nuisance associated with the odour sensations, and thus the need to remove them from the air, deodorization techniques are commonly used. Biofiltration is one of the methods of reducing odorants in the air stream. In...
-
Electronic nose as a tool for differentiation of volatile organic compounds = Elektroniczny nos jako instrument do rozróżniania lotnych związków organicznych
PublikacjaW pracy porównano dwie metody analizy zapachów lotnych związków organicznych: klasyczną analizę opartą na percepcji ludzkiego węchu i technikę elektronicznego nosa. W przeprowadzonych badaniach za pomocą klasycznej analizy brało udział 8 ochotników w okresie 2 tygodni. Do instrumentalnej metody analizy zapachu wykorzystano zaprojektowany przez autorów prototypowy 6-cio czujnikowy elektroniczny nos. Przeprowadzone badania z wykorzystaniem...
-
Prototype of electrochemical sensor for measurements of volatile organic compounds in gases
PublikacjaThe paper presents a laboratory prototype of an electrochemical sensor for measurements of volatile organic compounds (VOCs) in gases, utilizing ionic liquids and commercial screen printed electrodes by DropSens. The following ionic liquids have been tested as the electrolyte and redox reaction environment: 1-butyl, 3-methylimidazolium dicyanoamide ([BMIM][N(CN)2]), 1-octyl, 3-methylimidazolium tetrafluoroborate ([OMIM][BF4]),...
-
Effect of oxygenation time on signal of a sensor based on ionic liquids
PublikacjaThe paper presents an oxygen sensor based on ionic liquids and solid electrodes. The following ionic liquids have been employed: [BMIM][BF4], [HMIM][Cl], [BMIM][N(CN2)]. Minimum time of the sensor exposure to analyte, after which the signal (current intensity) was stable, has been evaluated. An impact of volumetric flow rate of analyte on the sensor exposure time and signal has been determined. A product of permeability coefficient...
-
IDENTIFICATION OF ODOR OF VOLATILE ORGANIC COMPOUNDS USING CLASSICAL SENSORY ANALYSIS AND ELECTRONIC NOSE TECHNIQUE
PublikacjaThe paper compares two methods of analysis of odour of volatile organic compounds: classical sensory analysis and electronic nose technique. Eight volunteers participated in the classical sensory analysis investigations, which lasted two weeks. An instrumental odour analysis involved a prototype of 6-sensor electronic nose designed by the authors. The research performed with this device provided higher reproducibility and reliability...