Filtry
wszystkich: 14021
-
Katalog
- Publikacje 10565 wyników po odfiltrowaniu
- Czasopisma 87 wyników po odfiltrowaniu
- Konferencje 15 wyników po odfiltrowaniu
- Wydawnictwa 1 wyników po odfiltrowaniu
- Osoby 120 wyników po odfiltrowaniu
- Projekty 1 wyników po odfiltrowaniu
- Aparatura Badawcza 1 wyników po odfiltrowaniu
- Kursy Online 91 wyników po odfiltrowaniu
- Wydarzenia 8 wyników po odfiltrowaniu
- Dane Badawcze 3132 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: BLOOD PRESSURE, PULSE TRANSIT TIME, NONINVASIVE MEASUREMENTS, SAMPLING FREQUENCY, LOW PASS FILTER
-
The measurement of input power of power supply in network disturbed by low frequency distortions
PublikacjaIn the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elements of studied device responsible for input power increase are pointed
-
Blood equivalent phantom vs whole human blood, a comparative study
PublikacjaPreclinical research of biomedical optoelectronic devices is often performed with the use of blood phantoms — a simpli¯ed physical model of blood. The aim of this study is the comparison and distinction between blood phantoms as well as whole human blood measurements. We show how the use of such phantoms may in°uence the incorrect interpretation of measured signal. On the other hand, we highlight how the use of blood phantoms enables...
-
Microstrip line with short-circuited edge as a high-pass filter operating up to millimeter-wave frequencies
PublikacjaPrzedstawiono prosty planarny filtr górnoprzepustowy wykorzystujący linię mikropaskową ze zwartym brzegiem. Układy zaprojektowano w taki sposób, aby pasmo przepustowe rozpoczynało się w zakresie K lub Ka. Wykonano dwa prototypy: na podłożu w postaci warstwy dielektrycznej wykonanej z ceramiki alundowej oraz na podłożu organicznym o niskiej przenikalności elektrycznej. Wykazano dużą zgodność teoretycznych i pomierzonych charakterystyk...
-
Audible noise in ship’s electrical drive systems with frequency converters
Dane BadawczeThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
Multi-layered tissue head phantoms for noninvasive optical diagnostics
PublikacjaExtensive research in the area of optical sensing for medical diagnostics requires development of tissue phantoms with optical properties similar to those of living human tissues. Development and improvement of in vivo optical measurement systems requires the use of stable tissue phantoms with known characteristics, which are mainly used for calibration of such systems and testing their performance over time. Optical and mechanical...
-
Multifunctional Bandpass Filter/Displacement Sensor Component
PublikacjaThis paper presents the design and realization of a multifunctional bandpassfilter/displacement-sensor using an edge-coupled microstrip bandpass filter loaded by a pair of split ring resonators (SRRs). It is shown that while the structure acts as a bandpass filter at its operating frequency, the phase of the reflection coefficient from a movable loading resonator at the resonance frequency of the resonator can be used for displacement...
-
Inhomogeneity of low-noise wearing courses evaluated by tire/road noise measurements using the close-proximity method
PublikacjaPerforming numerous analyses of tire/road noise measurements on low-noise pavements during the last several years, the authors observed significant inhomogeneity of the wearing course in numerous cases, while similar problems were almost non-existent when dense pavements were measured. Three main causes of low-noise pavement inhomogeneity can be defined. The first one is imperfections in the technology used for asphalt mix production...
-
Nonlinear generation of non-acoustic modes by low-frequency sound in a vibrationally relaxing gas
PublikacjaTwo dynamic equations referring to a weakly nonlinear and weakly dispersive flow of a gas in which molecular vibrational relaxation takes place. are derived. The first one governs an excess temperature associated with the thermal mode, and the second one describes variations in vibrational energy. Both quantities refer to non-wave types of gas motion. These variations are caused by the nonlinear transfer of acoustic energy into...
-
A hybrid, coupled reactors based 18-pulse diode rectifier with active power filter
Publikacja -
Temporal Changes in Complexity of Cardiovascular Regulation during Head-Up Tilt Test by Entropic Measures of Fluctuations of Heart Period Intervals and Systolic Blood Pressure
PublikacjaTemporal changes in complexity of cardiovascular regulation during head-up tilt test by entropic measures of fluctuations of heart period intervals and systolic blood pressure
-
A new time-frequency detection method of stray current field interferenceon metal structures.
PublikacjaA new detection method has been presented of stray current field interference on underground metal structures. The method employs short time Fourier transformation (STFT). This method of analysis allows determination of signal spectral power density changes (e.g., structure potential) in the function of time. In the paper results have been presented of total time–frequency analysis of a pipeline potential in a stray current field...
-
Modelling of Asphalt Mixes under Long Time Creep at Low Temperatures
PublikacjaProper description of asphalt mixtures behavior under long time load is one of the most important factors in analyses of strain and stress relations at low temperatures both from traffic and environmental loads. For example different models of thermal stress accumulation require different approaches of description of asphalt concrete. But in all cases it is required to describe its behavior under long time loading, which in some...
-
A Case for Less Intensive Blood Pressure Control: It Matters to Achieve Target Blood Pressure Early and Sustained Below 140/90mmHg
Publikacja -
Five-phase induction motor drive with sine-wave filter
PublikacjaThe paper presents closed loop ac drive with 5 phase induction motor operating with voltage source inverter and sine wave filter. The motor supply voltages and currents have sinusoidal shape. For well known adjustable electric drives the field oriented control method with flux and speed co ntrol can be applied. In the presence of output filter both control and estimation algorithms should be modified due to sine wave filter installation....
-
Filter-Hilbert Method for Automatic Correction of Non-Anechoic Antenna Measurements with Embedded Self-Calibration Mechanism
PublikacjaOne of the most important steps in the process of antenna development involves measurements of its prototype. Far-field performance of radiators is normally characterized in strictly controlled environments such as anechoic chambers which can ensure certification-grade accuracy. Unfortunately, they are also characterized by high construction costs which might not be justified for low-budget research and/or teaching-related activities....
-
Noninvasive method for rotor fault diagnosis in inverter fed induction motor drive
PublikacjaThis article presents a proposal, simulation and experimental results of a noninvasive rotor fault diagnosis method for the inverter fed induction motor drive. Comparing to reported methods the proposed one does not require any load, rotor brake, slip, mechanical or electrical system physical modification e.g. machine disassembly and can be applied regardless the rotor speed measurement or estimation method.
-
The Low-frequency Noise of SiC MESFETs
PublikacjaPrzedstawiono system do pomiaru szumów małoczestotliwościowych tranzystorów SiC MESFET oraz przykładowe wyniki pomiarów.
-
Asphalt concrete subjected to long-time loading at low temperatures – Deviations from the time-temperature superposition principle
PublikacjaThe article presents the observed deviations from the time-temperature superposition principle of asphalt concretes, tested in the bending beam creep test at low temperatures for a long time of loading. In almost all tested asphalt concretes, deviations appeared after 500 s of loading at the temperature of -10 C. Some types of bitumen presented deviations at other temperatures – usually the harder the grade of the bitumen, the...
-
A Nyquist filter of fractional delay
PublikacjaIn the paper a novel discrete-time FIR fractonal delay specjal filter is investigated. This is a Nyquist filter which, besides the traditional its attribute (interymbol interference (ISI) free property), has the ability to compensate for subsample transmission delay involved, for example, in multipath propagation channel. The performance of the filter is analysed and illustrated.
-
The current amplifier in low frequency noise measurements; Absolute calibration and rigorous 1/f noise extraction for MOSFET´s
PublikacjaPrzedstawiono budowę wzmacniacza prądowego i sposób obliczania szumów wyjściowych przy dołączonym do wejścia rezystorze wzorcowym. Przedstawiono wyniki eksperymentów potwierdzających prawidłowość przyjętego sposobu postępowania. Zaproponowano metodę wyznaczania składowej 1/f szumów drenu tranzystora MOSFET.
-
Modeling of Cardiac Component of Subarachnoid Space Changes in Apnoea Resulting as a Function of Blood Pressure and Blood Flow Parameters - Two Mechanizm of Regulation
PublikacjaExperiments were performed in a group of 19 healthy, non-smoking volunteers. The experiment consisted of three apnoeas, sequentially: 30 s apnoea, 60 s apnoea and maximal, that could be done, apnoea. The breath-hold was separated for 5 minutes rest. The following parameters were measured and obtained for further analysis: blood parameters, artery diameter of the internal carotid artery, end-tidal CO2 in expired air, the cardiac...
-
High frequency dynamics of an isotropic Timoshenko periodic beam by the use of the Time-domain Spectral Finite Element Method
PublikacjaIn this work results of numerical simulations and experimental measurements related to the high frequency dynamics of an aluminium Timoshenko periodic beam are presented. It was assumed by the authors that the source of beam structural periodicity comes from periodical alterations to its geometry due to the presence of appropriately arranged drill-holes. As a consequence of these alterations dynamic characteristics of the beam...
-
On the use of a charge balancing method for low energy measurements
PublikacjaThe paper presents the method for the estimation of the energy consumption of the low-power microcontroller-based devices. Due to high dynamics of the changes of the supply current of the tested devices during the operational cycle, the consumed energy estimation is not easy. In order to avoid disadvantages of known methods, the charge balancing method was employed similarly like in some types of A/D converters.
-
Analysis of the Accuracy of Pulse Estimation Using Smart Watches
PublikacjaThe purpose of this paper is to perform an analysis of the accuracy of the pulse estimation by comparing readings from a smartwatch with readings from medical devices. The study required writing applications that allow continuous pulse measurement. As a result, two applications were created for the smartwatch. The first one is dedicated to Android Wear devices, while the other one is compatible with Tizen watches. The next step...
-
Characterization of Corrosion-Induced Fracture in Reinforced Concrete Beams Using Electrical Potential, Ultrasound and Low-Frequency Vibration
PublikacjaThe paper deals with the non-destructive experimental testing of the reinforced concrete beams under progressive corrosion. A series of experiments using electrical potential, ultrasound and low-frequency vibrations techniques are reported. Electrical potential and natural frequencies were used to characterise and monitor the corrosion process at its initial state. The P-wave velocity measurements were proved to be effective in...
-
Relationship between heart rate variability, blood pressure and arterial wall properties during air and oxygen breathing in healthy subjects
PublikacjaPrevious studies reported that normobaric hyperoxia influences heart rate, arterial pressure, cardiac output and systemic vascular resistance, but the mechanisms underlying these changes are still not fully understood. Several factors are considered including degeneration of endothelium-derived nitric oxide by reactive oxygen species, the impact of oxygen-free radicals on tissues and alterations of autonomic nervous system function....
-
Optoelectronic device for hematocrit measurements
PublikacjaAn optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed...
-
Directed pulse dynamics
PublikacjaIntroducing a projection method into a one-dimensional model of a pulse propagation in isotropic media, we derive and investigate a system of equation describing dynamics ultrashort pulses of opposite directions ofpropagation and ones with interaction of directed pulses with different polarization.
-
Non-invasive blood glucose monitoring with Raman spectroscopy: prospects for device miniaturization
PublikacjaThe number of patients with diabetes has reached over 350 million, and still continues to increase. The need for regular blood glucose monitoring sparks the interest in the development of modern detection technologies. One of those methods, which allows for noninvasive measurements, is Raman spectroscopy. The ability of infrared light to penetrate deep into tissues allows for obtaining measurements through the skin without its...
-
Validation of atmospheric aerosols parallel sampling in a multifold device
PublikacjaIn this work, particulate matter was collected using an active sampling system consisting of a PM10 (<10 μm) inlet coupled to a multifold device containing six channels, connected to a vacuum pump. Each channel was equipped with a filter holder fitted with adequately chosen filters. The system was fixed on a metallic structure, which was placed on the roof of the laboratory building, at the Faculty of Sciences, in Lisbon. Sampling...
-
Quasi-discrete modelling of PMSM phase currents in drives with low switching-to-fundamental frequency ratio
PublikacjaThis study proposes a new quasi-discrete approach to modelling the permanent magnet synchronous motor (PMSM). The quasi-discrete modelling reflects the impact of continuous rotor movement, which takes place during a control cycle, on the shape of motor current waveforms. This provides much improvement in current modelling accuracy under inverter low switching-to-fundamental frequency operation. The proposed approach may be used...
-
In-ADC, Rank-Order Filter for Digital Pixel Sensors
PublikacjaThis paper presents a new implementation of the rank-order filter, which is established on a parallel-operated array of single-slope (SS) analog-to-digital converters (ADCs). The SS ADCs use an “on-the-ramp processing” technique, i.e., filtration is performed along with analog-to-digital conversion, so the final states of the converters represent a filtered image. A proof-of-concept 64 × 64 array of SS ADCs, integrated with MOS...
-
Numerical solutions for blood flow in elastic vessels
PublikacjaWe consider the differential–algebraic system for the blood flow and pressure in the systemic arteries. By the operator splitting method, we transform the system into the hyperbolic one, introduce the bicharacteristics, and perform the time–space nonuniform discretization, obtaining the innovative difference scheme. Our results are illustrated with numerical experiments.
-
The instantaneous frequency rate spectogram
PublikacjaAn accelerogram of the instantaneous phase of signal components referred to as an instantaneous frequency rate spectrogram (IFRS) is presented as a joint time-frequency distribution. The distribution is directly obtained by processing the short-time Fourier transform (STFT) locally. A novel approach to amplitude demodulation based upon the reassignment method is introduced as a useful by-product. Additionally, an estimator of energy...
-
Flow Maps and Flow Patterns of R1233zd(E) in a Circular Minichannel at Low, Medium and High Values of Saturation Pressure
PublikacjaThere is a gap in knowledge regarding the flow pattern of low-boiling working fluids in the range of high saturation temperatures (above 120°C) and medium and high reduced pressures (0.5-0.9). Data are present in the literature for similar values of reduced pressures, but for lower values of saturation temperature. This is due to the existing refrigeration applications of these working fluids. At high values of reduced pressure,...
-
Oxygen partial pressure and temperature dependence of low frequency capacitance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Dane BadawczeThis dataset contains values of low frequency capacitance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Oxygen partial pressure and temperature dependence of low frequency resistance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Dane BadawczeThis dataset contains values of low frequency resistance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Application of time-frequency methods for analysis of dynamic silo flow
PublikacjaW artykule przedstawiono możliwość stosowania metod czasowo-częstotliwościowych w analizie dynamicznego przepływu materiału sypkiego w silosie. W pracy omówiono wyniki FT (Fourier Transform), STFT (Short Time Fourier Transform) oraz WT (Wavelet Transform)
-
Self-Testing of Analog Parts Terminated by ADCs Based on Multiple Sampling of Time Responses
PublikacjaA new approach for self-testing of analog parts terminated by analog-to-digital converters in mixed-signal electronic microsystems controlled by microcontrollers is presented. It is based upon a new fault diagnosis method using a transformation of the set of voltage samples of the time response of a tested analog part to a square impulse into localization curves placed in a multidimensional measurement space. The method can be used...
-
Laboratory Load Model Based on 150 kVA Power Frequency Converter and Simulink Real-Time – Concept, mplementation, Experiments
PublikacjaFirst section of the paper provides technical specification of laboratory load model basing on 150 kVA power frequency converter and Simulink Real-Time platform. Assumptions, as well as control algorithm structure is presented. Theoretical considerations based on criteria which load types may be simulated using discussed laboratory setup, are described. As described model contains transformer with thyristor-controlled tap changer,...
-
Effect of CPAP on Blood Pressure in Patients With OSA/Hypopnea
Publikacja -
Asymmetric features of short-term blood pressure variability
Publikacja -
Analysis of correlation between heart rate and blood pressure
PublikacjaW artykule przedstawiono analizę korelacji pomiędzy częstością akcji serca (HR) i ciśnieniem krwi (BP). Wykorzystano rzeczywiste pomiary ciśnienia skurczowego i rozkurczowego krwi zmierzonego metodą inwazyjną w tętnicy promieniowej. Ze względu na możliwe zaszumienie sygnału przeanalizowano także dane po filtracji filttrem uśredniającycm oraz wykonano analizę trendów sygnałów. Wyniki analizy zarówno danych pomiarowych jak i filtrowanych...
-
Impact of surface skin temperature change on blood flow characteristics in palm
PublikacjaHeating a human palm during 3 minutes period causes changes in superficial skin temperature and leads to thermoregulation system response. The response time and level of flow characteristics change depend on the subject hand size and health of his vascular tree. A solution of Pennes bioheat propagation model was analyzed in order to see how much heat has to be transferred into the tissue to extort the observable reaction. The reflective...
-
Impact of aeration conditions on the removal of low concentrations of nitrogen in a tertiary partially aerated biological filter
PublikacjaA submerged biological aerated filter (BAF) partially aerated was used to study the removal of low concentrations of ammonia nitrogen (0.3 g N/m3 to 30.5 g N/m3) typically found in nutrient enriched river and lake waters, and treated effluents. Four series of experiments were performed with a synthetic wastewater at ammonia loading rates between 6 g N/m3 d and 903 g N/m3 d and C/N ratios from 2 to 20. The results showed that ammonia...
-
Joint time–frequency analysis of electrochemical noise
Publikacja -
On the joint time-frequency characteristics of chemical oscillations
PublikacjaZaprezentowano rezultaty analizy czasowo-częstotliwościowej rejestrów potencjałowych oscylacyjnej reakcji Biełousowa-Żabotyńskiego (BŻ). Wybraną reprezentację czasowo-częstotliwościową w postaci algorytmu STFT zastosowano do analizy typowych przebiegów reakcji BŻ, prowadzonej w układzie zamkniętym. Zaprezentowano spektrogramy STFT ukazujące czasowo-częstotliwościową strukturę oscylacji regularnych, mieszanych i chaotycznych. Na...
-
Sympathetic Activation Does Not Affect the Cardiac and Respiratory Contribution to the Relationship between Blood Pressure and Pial Artery Pulsation Oscillations in Healthy Subjects
PublikacjaUsing a novel method called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) and subarachnoid width (sas-TQ) in humans, we assessed the influence of sympathetic activation on the cardiac and respiratory contribution to blood pressure (BP) cc-TQ oscillations in healthy subjects. The pial artery and subarachnoid width response to handgrip...
-
Design of mm-wave MIC frequency multiplayers and mixers using simple microstrip high-pass filters
PublikacjaPrzedyskutowano podstawowe wymagania dotyczące impedancji elementów półprzewodnikowych wykorzystywanych w mieszaczach i powielaczach częstotliwości projektowanych dla zakresu fal milimetrowych. Określono typy układów filtrujących niezbędnych w różnych częściach układów, podkreślając znaczenie filtrów górnoprzepustowych. Mikropaskowy filtr ze zwartym brzegiem został wykonany i zaimplementowany w mieszaczu pracującym w zakresie 20-40GHz.
-
Application of passive sampling techniques as a usable tool in the field of environmental quality monitoring
PublikacjaAnalysis of literature data published for the past 20 years leads to the conclusion, that passive sampling technique has been developing very quickly and is commonly used in the field of monitoring pollutants in air, water and soil environment. The popularity of application of passive sampling techniques in analytical and environmental chemistry results from its many advantages e.g.: Simplicity in use, low costs of exploitation,...