Filtry
wszystkich: 4229
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: GOLD ELECTRODES EFFECT
-
Electrodes criticality: the impact of CRMs in the leachate electrochemical oxidation
Publikacja -
Equilibration Time of Solid Contact Ion-Selective Electrodes
Publikacja -
Electrochemical oxidation of PFOA and PFOS in landfill leachates at low and highly boron-doped diamond electrodes
PublikacjaPolyfluorinated alkyl substances (PFASs) may reach landfill leachates (LLs) due to improper waste management. In this study perfluorooctanoate (PFOA) and perfluorooctane sulphonate (PFOS) were used as representatives of PFASs in the decomposition on boron-doped diamond electrodes (BDDs) with high (10k ppm) and low (0.5k ppm) boron doping concentrations. The result shows that although better COD removal efficacies are obtained on...
-
Electrochemical stability of TiO2 nanotubes deposited with silver and gold nanoparticles in aqueous environment
Publikacja -
Gold-modified paper as microfluidic substrates with reduced biofouling in potentiometric ion sensing
Publikacja -
The recovery of cyanide from gold leach = Odzysk cyjanku w ługowaniu złota
PublikacjaW artykule omówiono nową technologię odzyskiwania lub degradacji cyjanków z wykorzystaniem reaktora z wirującymi płynami. Testy polowe i próby laboratoryjne wykazały, że ta technologia może znaleźć zastosowanie do odpędzania i ponownej absorpcji HCN z wody procesowej powstającej w kopalni złota.
-
The effect of flaxseed addition on the quality and basic composition of wheat bread
Dane BadawczeThe dataset includes the effect of flaxseed addition on the properties of toasted bread bakery products such as basic composition, moisture content immediately after baking and after a defined time, porosity, acidity and total baking loss. The following bread variants were investigated: control bread, bread with 8% and 12% flaxseed addition and competitive...
-
Performance of electrochemical immunoassays for clinical diagnostics of SARS-CoV-2 based on selective nucleocapsid N protein detection: Boron-doped diamond, gold and glassy carbon evaluation
PublikacjaThe 21st century has already brought us a plethora of new threats related to viruses that emerge in humans after zoonotic transmission or drastically change their geographic distribution or prevalence. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was first spotted at the end of 2019 to rapidly spread in southwest Asia and later cause a global pandemic, which paralyzes the world since then. We have designed novel...
-
Amperometric sensing of chemical oxygen demand at glassy carbon and silicon electrodes modified with boron-doped diamond
Publikacja.A boron-doped diamond (BDD) sensor is proposed for effective detection of chemical oxygen demand (COD) by means of amperometric technique. Boron-doped diamond thin films, acting as active sensors, were deposited on both silicon wafer and glassy carbon (GC) substrates by microwave plasma assisted chemical vapour deposition. SEM micrographs showed that BDD–Si displays triangle-faceted crystallites ca. 0.5–3 μm in size, while BDD–GC...
-
The effect of wax foundation addition to PCL filaments on mechanical properties.
Dane BadawczeThe dataset includes the effect of wax foundation addition on the basic mechanical properties of the filaments. PCL and wax foundation addition at 10 and 15% were used for extrusion. The mechanical properties of the resulting filaments were evaluated by a double compression test using an Instron model 5543 universal testing machine. Parameters such...
-
Electrodes consisting of PEDOT modified by Prussian Blue analogues deposited onto titania nanotubes – Their highly improved capacitance
PublikacjaIn this work we present the outstanding energy storage of prepared inorganic-organic heterojunction where hydrogenated ordered titania nanotubes (H-TiO2NT) were modified by the hybrid made of poly(3,4-ethylenedioxythiophene) (pEDOT) and iron hexacyanoferrate centres (Fehcf, Prussian Blue). The material TiO2NT/pEDOT:Fechf was obtained electrochemically by means of: anodization, hydrogenation and finally, electropolymerization of...
-
Effect of oxygenation time on signal of a sensor based on ionic liquids
PublikacjaThe paper presents an oxygen sensor based on ionic liquids and solid electrodes. The following ionic liquids have been employed: [BMIM][BF4], [HMIM][Cl], [BMIM][N(CN2)]. Minimum time of the sensor exposure to analyte, after which the signal (current intensity) was stable, has been evaluated. An impact of volumetric flow rate of analyte on the sensor exposure time and signal has been determined. A product of permeability coefficient...
-
FE investigations of the effect of fluctuating local tensile strength on coupled energetic-statistical size effect in concrete beams
PublikacjaThe effect of fluctuating local tensile strength on a coupled energetic-statistical size effect in plain concrete beams under bending was numerically investigated. First, the influence of varying autocorrelation length of the random field describing a spatial variation of local tensile strength was studied. Next, the influence of the coefficient of variation of local tensile strength was analyzed. The numerical FE investigations...
-
Pitting corrosion characterization by electrochemical noise measurements on asymmetric electrodes
PublikacjaKorozja wżerowa stali nierdzewnych może być wykryta za pomocą obserwacji charakterystycznych sygnałów prądowych, jakie płyną między dwiema elektrodami metalowymi. W artykule proponuje się wyznaczanie funkcji bispektrum dla układu dwóch elektrod o istotnie różnej powierzchni narażonej na występowanie korozji. Proponowana metoda została zastosowana do analizy korozji wżerowej stali 0H18N9 powstającej pod wpływem 1M roztworu FeCl3...
-
Portable reactor with LTCC electrodes for production of plasma activated water
Publikacja -
Kinetic Description of the Membrane–Solution Interface for Ion-Selective Electrodes
Publikacja -
Lead(II)-selective ionophores for ion-selective electrodes: A review
Publikacja -
Electrospun Nanofiber Electrodes with in situ Exsolved Nanocatalysts for Symmetrical SOCs
Publikacja -
Electrospun Nanofiber Electrodes with in situ Exsolved Nanocatalysts for Symmetrical SOCs
Publikacja -
Nano-engineered diamond-based materials for supercapacitor electrodes: A review
PublikacjaOwing to the popularity of carbon-based supercapacitors, diamond has also been examined as a potential candidate with unique advantages such as a wide electrochemical potential window and stable capacitive behavior in both aqueous and non-aqueous electrolytes. Moreover, its chemical stability in harsh environments at extreme applied potential and current provides rare opportunities for designing new supercapacitors. Owing to the...
-
Tuning of the Electrochemical Properties of Transparent Fluorine-doped Tin Oxide Electrodes by Microwave Pulsed-plasma Polymerized Allylamine
PublikacjaWe report here the dry, one-step, and low-temperature modification of FTO surfaces using pulsed plasma polymerization of allylamine (PPAAm). PPAAm/FTO surfaces were characterized by X-ray photoelectron spectroscopy, spectroscopic ellipsometry, and contact angles to understand the morphological, structural, and optical properties. FTO were coated with a very thin layer of adherent cross-linked, pinhole-, and additive-free allylamine...
-
The Werther Effect, the Papageno Effect or No Effect? A Literature Review
Publikacja -
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, bath simulation - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Visible-light-induced photocatalysis through surface Plasmon excitation of gold on titania surfaces
PublikacjaPietnascie komercyjnych probek tlenku tytanu(IV) zostalo zmodyfikowanych zlotem za pomoca fotodepozycji oraz scharakteryzowanych. Fotoaktywnosci proszkow Au/TiO2 zostaly przebadane dla fotodegradacji kwasu octowego i 2-propanolu podczas naswietlania promieniowaniem widzialnym oraz ultrafioletowym. Wykazano, ze fotokatalityczne aktywnosci scisle zaleza od wlasciwosci nanoczastek zlota i tlenku tytanu. Analizy spektrum działania...
-
Fermented juices as reducing and capping agents for the biosynthesis of size-defined spherical gold nanoparticles
Publikacja -
Structure and electrochemical reactivity of new sulphur–silicon podands adsorbed on silver or gold surfaces
Publikacja -
Study of oxygen electrode reactions on symmetrical porous SrTi0.30Fe0.70O3-δ electrodes on Ce0.8Gd0.2O1.9 electrolyte at 800 °C–500 °C
PublikacjaIron doped strontium titanates (SrTi1-xFexO3-δ) are an interesting mixed ionic-electronic conductor model used to study basic oxygen reduction/oxidation reactions. In this work, we performed an impedance spectroscopy study on symmetrical porous SrTi0.30Fe0.70O3-δ (STF70) electrodes on a ceriabased electrolyte. The sample was measured in varying oxygen concentration: from 0.3% to 100% in 800 °C - 500 °C temperature range. Low polarisation...
-
Study on surface termination of boron-doped diamond electrodes under anodic polarization in H2SO4 by means of dynamic impedance technique
PublikacjaAnodic oxidation is a popular way to modify termination bonds at boron doped diamond electrodes altering their electrochemical and physicochemical properties. Our studies, performed with dynamic electrochemical impedance spectroscopy technique, supported with X-ray photoelectron spectroscopy and ellipsometry analysis prove its utility in continuous on-line monitoring of impedance changes on the electrode surface under polarization...
-
Multifrequency Nanoscale Impedance Microscopy (m-NIM): A novel approach towards detection of selective and subtle modifications on the surface of polycrystalline boron-doped diamond electrodes
PublikacjaIn this paper, we describe the modification of Nanoscale Impedance Microscopy (NIM), namely, a combination of contact-mode atomic force microscopy with local impedance measurements. The postulated approach is based on the application of multifrequency voltage perturbation instead of standard frequency-by-frequency analysis, which among others offers more time-efficient and accurate determination of the resultant impedance spectra...
-
Effect of electrode waterproof coating on quality of underwater wet welded joints
PublikacjaIn this paper, the effects of different hydrophobic coatings on the surface of covered electrodes on the quality of wet welded carbon steel joints were discussed. Commonly available hydrophobic substances used in industrial applications were selected for the research. The aim of using waterproof coatings was to check the possibility to decreasing the susceptibility of highstrength low-alloy S460N steel to cold cracking. During...
-
Solid-contact lead(II) ion-selective electrodes for potentiometric determination of lead(II) in presence of high concentrations of Na(I), Cu(II), Cd(II), Zn(II), Ca(II) and Mg(II)
PublikacjaLead and its compounds are a serious threat to the environment. Monitoring of this toxic heavy metal is a driving force for the continuous development of novel lead(II) ionophores to be applied in ion-selective electrodes. In this work a highly selective lead(II) ionophore, namely 25,26,27,28-tetrakis(piperidinylthiocarbonylmethylene)-p-tert-butylcalix[4]arene, was used in solid-contact ion-selective electrodes for determination...
-
Applying the Lombard Effect to Speech-in-Noise Communication
PublikacjaThis study explored how the Lombard effect, a natural or artificial increase in speech loudness in noisy environments, can improve speech-in-noise communication. This study consisted of several experiments that measured the impact of different types of noise on synthesizing the Lombard effect. The main steps were as follows: first, a dataset of speech samples with and without the Lombard effect was collected in a controlled setting;...
-
Effects of thermal history on the performance of low-temperature solid oxide fuel cells with Sm0.2Ce0.8O2-δ electrolyte and LiNi0.81Co0.15Al0.04O2 electrodes
PublikacjaIn this study, low-temperature solid oxide fuel cells with an ∼560 μm thick Sm0.2Ce0.8O2−δ (SDC) electrolyte and ∼890 μm thick LiNi0.81Co0.15Al0.04O2−δ (NCAL) electrodes are constructed and characterized under three experimental conditions. The cell with an NCAL cathode pre-reduced under an H2 atmosphere at 550 °C presents the best electrochemical performance. This is ascribed to facts that the reduction reaction generating Ni–Co...
-
ECG measurement in the bathtub - electrodes at the feet, drl behind the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on measuring electrodes, drl in water - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
The possibility of application of the potentiometric sensor with all-solid-state electrodes containing lipid-polymer membranes for classification of tested black leaf teas in terms of their quality
PublikacjaPotentiometric sensor with all-solid-state electrodes containing lipid-polymer membranes for a set of black leaf teas coming from four countries (China, India, Sri Lanka and Kenia) classification was applied. The tested tea samples were reassigned to quality classes marked with numbers I–V according to the information available. The sensor results of tea samples are presented in the form of radar charts. It was observed that, in...
-
Electrochemical oxidation of ionic liquids at highly boron doped diamond electrodes
Publikacja -
Preparation and characterisation of visible light responsive iodine doped TiO2 electrodes
PublikacjaPraca przedstawia charakterystykę domieszkowanego jodem ditlenku tytanu (I-TiO2) otrzymanego na drodze hydrotermicznej syntezy, gdzie prekursor stanowiły komplesy tytanu (IV) z ligandami zawierającymi atom jodu. Struktura nowego materiału została opisana za pomocą technik XPS, XRD, UV-vis i FT-IR-ATR. Badania te potwierdziły, że otrzymany proszek I-TiO2 ma zmniejszoną przerwę energetyczną. Praca prezentuje również badania elektrochemiczne...
-
On stability of iodine doped TiO2 electrodes in pH varied aqueous electrolytes
PublikacjaW pracy przedstaiono charakterystykę elektrochemiczną warstwy domieszkowanego jodem TiO2 na podłożu platynowym. Wyniki badań prowadzone w elektrolitach o różnym pH pozowoliły na określenie właściwości na granicy faz elektroda - elektrolit. Wyznaczono zależność potencjału pasma płaskiego od pH elektrolitu, a charakter otrzymanej funkcji potwirdził stabilność proszku I-TiO2 w kontakcie s roztworem.
-
Enzymatic electrodes nanostructured with functionalized carbon nanotubes for biofuel cell applications
PublikacjaNanostructured bioelectrodes were designed and assembled into a biofuel cell with no separating membrane.
-
Investigation of sour substances by a set of all-solid-state membrane electrodes
PublikacjaTestowano elektrody typu all solid state (ASS) w roztworach elektrolitów zawierających substancje o smaku kwaśnym. Elektrody typu ASS zawierają dwa typy membran. Badano wpływ grubości membrany oraz stosunku związek lipofilowy/ chlorek poliwinilu na odpowiedzi elektrod. Stwierdzono, że grubość elektro aktywnego polimeru, nie ma wpływu na czułość i stabilność elektrod w przeciwieństwie do grubości membrany składającej się ze związku...
-
Plasticized PVC Membrane Modified Electrodes: Voltammetry of Highly Hydrophobic Compounds
Publikacja -
Electrochemical oxidation of ionic liquids at highly boron doped diamond electrodes
PublikacjaUtlenianie elektrochemiczne przy zastosowaniu elektrod diamentowych wysoko domieszkowanych borem (BDD) było badane pod względem przydatności do utylizacji roztworów zawierających ciecze jonowe (ILs). Dwustronne elektrody Si/BDD przygotowano metodą chemicznego osadzania z fazy lotnej wspomaganego plazmą (MW PE CVD). Badanie przy użyciu skaningowej mikroskopii elektronowej (SEM) potwierdziło, że wytworzone warstwy były ciągłe i miały...