wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: accuracy
-
Head movement compensation algorithm in multi-display communication by gaze
PublikacjaAn influence of head movements on the gaze estimation accuracy when using a head mounted eye tracking system is discussed in the paper. This issue has been examined for a multi-display environment. It was found that head movement (rotation) to some extent does not influence on the gaze estimation accuracy seriously. Acceptable results were obtained when using eye-tracker to communicate with a computer via in two displays simultaneously.
-
Experimental Study of Silent Sonar
PublikacjaStealth is a frequent requirement in military applications and involves the use of devices whose signals are difficult to intercept or identify by the enemy. The silent sonar concept was studied and developed at the Department of Marine Electronic Systems of the Gdansk University of Technology. The work included a detailed theoretical analysis, computer simulations and some experimental research. The results of the theoretical...
-
Approximate Cramér–Rao bound on Doppler error in correlation-processing relatively narrowband noise radar
PublikacjaThe paper studies limitations on accuracy of Doppler estimation in continuous-wave noise radar with correlation processing. Second order properties of output of the correlation receiver are evaluated and an approximate Cram´er-Rao bound on errors of Doppler measurement is derived. The accuracy of Doppler measurements is found to be affected by the following factors: power spectral density of noise signal, frequency response of the...
-
Measurements of drive system properties of the "Magnetic SpeedLine" ultra-fast robot prototype for IML labeling
Dane BadawczeTests of the drive system of the ultra-fast robot "SpeedLine magnetic" for labeling with the IML method were carried out in order to analyze the influence of the operating parameters of the drive system on the correctness and quality of the drive system.
-
THE RESEARCH ON EGNOS SYSTEM IN CONTEXT OF THE ABILITY TO DETERMINE THE SHIP’S HULL SPATIAL ORIENTATION
PublikacjaThe European Geostationary Navigation Overlay Service (EGNOS) thanks to geostationary satellites covers an area of whole Europe, including Baltic and North Sea. It allows to fix the coordinates of object position with typical absolute accuracy of 1,5 m. Previous research have shown that relative accuracy is usually higher than absolute one [Nowak A., 2010, Nowak A., 2011], so probably it could be possible to use EGNOS to determine...
-
Verification of GNSS Measurements of the Railway Track Using Standard Techniques for Determining Coordinates
PublikacjaThe problem of the reproduction of the railway geometric layout in the global spatial system is currently solved in the form of measurements that use geodetic railway networks and also, in recent years, efficient methods of mobile positioning (mainly satellite and inert). The team of authors from the Gdańsk University of Technology and the Maritime University in Gdynia as part of the research project InnoSatTrack is looking for...
-
The analysis of the determination of points positions using photogrammetric methods
PublikacjaThis article was created as a result of research conducted within the master thesis. The purpose of the research was to analyze the accuracy of determining the actual position of the photographed points according to the calculated parameters. The accuracy of photos alignment was determined as parameters, which determine their external and internal orientation. In order to determine the location of the determined points, it was...
-
Framework for extracting rails and setting-out railway line axis based on UAV photogrammetric measurements
PublikacjaTechnical diagnostics enables assessing the current technical condition of a railway line and adjacent infrastructure, and forecasting its changes over a specific time horizon. One of its elements is the periodic monitoring of rail position and their geometry. This article presents a new framework for the setting-out of a railway track axis. The process presented in the manuscript is based on the specific filtration and extraction...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 140 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 160 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 180 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Analysis of spatial changes in the town of Puck with its surroundings in the years 1926, 1940, 1974, 1985, 2000, 2020 on the basis of topographic maps using the BDOT10K database
Dane BadawczeSpatial changes over time are extremely valuable due to the possibility of modeling forecasts. This dataset shows how Puck has evolved over a specific period of time. Thanks to this presentation of the data set, it is possible to easily recreate the appearance of the city in particular years.
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 200 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-0optic sensor - 250 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 210 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 300 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 270 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 190 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 260 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 290 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 170 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 280 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 150 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 230 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 240 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
The surface of a fragment of the structure of an integrated circuit in the semi-contact mode.
Dane BadawczeThe surface of a fragment of the structure of an integrated circuit. Topographic measurements in the semi-contact mode. NTEGRA Prima (NT-MDT) device. NSG 01 probe.
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.2
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.1
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Prognozowanie ostrzegawcze w małej firmie
PublikacjaW artykule pokazano możliwości zastosowania prostych metod prognostycznych do ostrzegania w małej firmie przed niekorzystnymi zjawiskami. Przedmiotem badań jest sprzedaż, a ze względu na występowanie w szeregu czasowym sezonowości, w celu wyznaczenia sygnałów ostrzegawczych dokonano porównań trendów prognozowanych i rzeczywistych w okresach jednoimiennych za pomocą pierwszych różnic. Do prognozowania sprzedaży wykorzystano proste...
-
Non-Contact Temperature Measurements Dataset
PublikacjaThe dataset titled The influence of the distance of the pyrometer from the surface of the radiating object on the accuracy of measurements contains temperature measurements using a selection of four commercially available pyrometers (CHY 314P, TM-F03B, TFA 31.1125 and AB-8855) as a function of the measuring distance. The dataset allows a comparison of the accuracy and measuring precision of the devices, which are very important...
-
Investigation of tracking systems properties in CAVE-type virtual reality systems
PublikacjaIn recent years, many scientific and industrial centers in the world developed a virtual reality systems or laboratories. One of the most advanced solutions are Immersive 3D Visualization Lab (I3DVL), a CAVE-type (Cave Automatic Virtual Environment) laboratory. It contains two CAVE-type installations: six-screen installation arranged in a form of a cube, and four-screen installation, a simplified version of the previous one. The...
-
Wpływ automatycznej kalibracji wizyjnego systemu pozycjonowania na dokładność lokalizacji elementu roboczego
PublikacjaW artykule przedstawiono strukturę i działanie automatycznego wizyjnego systemu pozycjonowania (PVS), który został zainstalowany na maszynie waterjet (WJ). Ponadto przeprowadzono analizę wpływu kalibracji na działanie PVS. Podstawę systemu stanowią dwie kamery internetowe zamontowane na przemysłowej maszynie WJ. W połączeniu z algorytmem identyfikacji, system przeznaczony jest do pozycjonowania WJ z dużą dokładnością. W tym celu...
-
A model development and experimental verification for a vapour microturbine with a permanent magnet synchronous generator
PublikacjaVapour microturbines with permanent magnet synchronous generators are implemented in micropower plants for dispersed power generation systems. The dynamic model of such a microturbine set was developed and presented. The developed relations result from the generic equations. Experimental data for two different working medium were used for model verification. A microturbine set model was tested during the changes in the parameters...
-
Adaptive filtering approach to dynamic weighing: a checkweigher case study
PublikacjaDynamic weighing, i.e., weighing of objects in motion, with out stopping them on the weighing platform, allows one to increase the rate of operation of automatic weighing systems used in industrial production processes without compromising their accuracy. The paper extends and compares two approaches to dynamic weighing, based on system identification and variable-bandwidth filtering, respectively. Experiments, carried on a conveyor...
-
Customization of UWB 3D-RTLS Based on the New Uncertainty Model of the AoA Ranging Technique
PublikacjaThe increased potential and effectiveness of Real-time Locating Systems (RTLSs) substantially influence their application spectrum. They are widely used, inter alia, in the industrial sector, healthcare, home care, and in logistic and security applications. The research aims to develop an analytical method to customize UWB-based RTLS, in order to improve their localization performance in terms of accuracy and precision. The analytical...
-
Performance analysis of an rfid-based 3d indoor positioning system combining scene analysis and neural network methods
PublikacjaThe main purpose of this research is to improve localization accuracy of an active Radio Frequency Identification, RFID tag, in 3D indoor space. The paper presents a new RFID based 3D Indoor Positioning System which shows performance improvement. The proposed positioning system combines two methods: the Scene Analysis technique and Artificial Neural Network. The results of both simulation using Log-Distance Path Loss Model and...
-
High-precision bearing estimation for active sonar with cylindrical array performed by interpolated array transformation
PublikacjaThe article presents a method for improving the accuracy of bearing in multibeam sonar with a cylindrical array. The antenna’s non-linear shape and the resulting non-uniform sampling of the signal in space, mean that known methods of high-resolution spectral analysis cannot be used. In order to apply an algorithm from this group, a linear virtual antenna must be produced. The paper presents a technique of mapping a cylindrical...
-
Verification of Satellite Railway Track Position Measurements Making Use of Standard Co-Ordinate Determination Techniques
PublikacjaThe article presents the results of satellite railway track position measurements performed by a multidisciplinary research team, the members of which represented Gdansk University of Technology and Gdynia Maritime University. Measuring methods are described which were used for reconstructing the railway track axis position and diagnosing railway track geometry deformations. As well as that, the description of the novel method...
-
A low complexity double-talk detector based on the signal envelope
PublikacjaA new algorithm for double-talk detection, intended for use in the acoustic echo canceller for voice communication applications, is proposed. The communication system developed by the authors required the use of a double-talk detection algorithm with low complexity and good accuracy. The authors propose an approach to doubletalk detection based on the signal envelopes. For each of three signals: the far-end speech, the microphone...
-
AngioScore: An artificial intelligence tool to assess coronary artery lesions
PublikacjaThe functionality scope of the AngioScore tool in semi-automatic assessment of stenoses according to the SYNTAX scale was presented. An evaluation of the preliminary accuracy of AngioScore in lesion assessment was performed.
-
Projektowanie i eksploatacja dróg szynowych z wykorzystaniem mobilnych pomiarów satelitarnych
PublikacjaNiniejsza monografia zawiera szczegółowy opis aktywnych sieci geodezyjnych GNSS oraz modelowania dokładności określania pozycji w pomiarach satelitarnych. Omówiono również opracowaną technikę mobilnych pomiarów satelitarnych toru kolejowego oraz aplikacje związane z jej zastosowaniem w projektowaniu i eksploatacji dróg szynowych. Autorzy zawarli w pracy wyniki swoich badań, wykonywanych na przestrzeni lat 2009–2015. Badania przeprowadzono...
-
Vocalic Segments Classification Assisted by Mouth Motion Capture
PublikacjaVisual features convey important information for automatic speech recognition (ASR), especially in noisy environment. The purpose of this study is to evaluate to what extent visual data (i.e. lip reading) can enhance recognition accuracy in the multi-modal approach. For that purpose motion capture markers were placed on speakers' faces to obtain lips tracking data during speaking. Different parameterizations strategies were tested...
-
Segmentation Quality Refinement in Large-Scale Medical Image Dataset with Crowd-Sourced Annotations
PublikacjaDeployment of different techniques of deep learning including Convolutional Neural Networks (CNN) in image classification systems has accomplished outstanding results. However, the advantages and potential impact of such a system can be completely negated if it does not reach a target accuracy. To achieve high classification accuracy with low variance in medical image classification system, there is needed the large size of the...
-
An analytical four-layer horizontal electric current dipole model for analysing underwater electric potential in shallow seawater
PublikacjaThe paper presents a new analytical four‑layer (air–water–bottom–non‑conductive layer) horizontal electric dipole model which allows an accurate approximation of ship’s Underwater Electric Potential (UEP) from a sufficient depth in shallow coastal marine waters. The numerical methods, usually Finite Element Method (FEM) or Boundary Elements Method (BEM), are typically used to estimate the electric field and the distribution of...
-
Method for determining of shallow water depths based on data recorded by UAV/USV vehicles and processed using the SVR algorithm
PublikacjaBathymetric measurements in waters shallower than 1 m are necessary to monitor seafloor relief changes in the coastal zone. This is especially important for ensuring the safety of navigation, navigation efficiency, as well as during the design and monitoring of hydrotechnical structures. Therefore, the aim of this article is to present a method for determining of shallow water depths based on data recorded by Unmanned Aerial Vehicle...
-
Economical wood sawing with circular saw blades
PublikacjaMaterial- and energy-saving belong to the basic requirements which are imposed on the contemporary manufacturing processes. Since realization of those processes gives measurable profits not only economical but also ecological. In case of wood sawing with circular saw blades material- and energy-savings are dependent on total overall set of teeth (theoretical kerf) and teeth position accuracy in relation to the workpiece. Hence,...
-
Direction-of-Arrival Estimation Methods in Interferometric Echo Sounding
PublikacjaNowadays, there are two leading sea sounding technologies: the multibeam echo sounder and the multiphase echo sounder (also known as phase-dierence side scan sonar or bathymetric side scan sonar). Both solutions have their advantages and disadvantages, and they can be perceived as complementary to each other. The article reviews the development of interferometric echo sounding array configurations and the various methods applied...
-
Portable Electronic Nose Based on Electrochemical Sensors for Food Quality Assessment
PublikacjaThe steady increase in global consumption puts a strain on agriculture and might lead to a decrease in food quality. Currently used techniques of food analysis are often labour-intensive and time-consuming and require extensive sample preparation. For that reason, there is a demand for novel methods that could be used for rapid food quality assessment. A technique based on the use of an array of chemical sensors for holistic analysis...