Uncertainty of the liquid mass flow measurement using the orifice plate
PublikacjaThe article presents an estimation of measurement uncertainty of a liquid mass flow using the orifice plate. This subject is essential because of the widespread use of this type of flow meters. Not only the quantitative estimation but also the qualitative results of those measurements are important. To achieve these results the authors of the paper propose to use the theory of uncertainty. The article shows the analysis of the...
-
Methodology of estimating temperature measurement uncertainty in a system for endurance tests.
PublikacjaThe team consisting of the article authors developed a non-invasive method and a system for measuring temperature during an endurance test. A thermocouple which provided the required accuracy of changes in temperature dynamics measurements was used for the purpose of the required research. The paper presents the methodology for estimating uncertainty of temperature measurement done with the presented system, using a method based...
-
Measurement of engine and vehicle parameters using onboard CAN network
PublikacjaWspółczesne samochody wyposażane są w dużą liczbę układów elektronicznych, które wymagają wzajemnej wymiany informacji. Techniczne problemy niezależnego łączenia ze sobą dużej liczby sterowników doprowadziły do powstania pokładowych sieci wymiany danych. Do najpopularniejszych z nich zalicza się obecnie system CAN. W pracy przedstawiono metodę rozpoznawania ramek wiadomości transmitowanych w pokładowej sieci CAN pojazdu przez sterowniki....
-
The Goertzel filter-bank usage in the non-stationary impedance measurement.
PublikacjaArtykuł prezentuje metodę pomiaru parametrów impedancyjnych w warunkach niestacjonarnych bazującą na próbkowaniu sygnałów pomiarowych i przetwarzaniu cyfrowym. Zaproponowano i przeanalizowano zastosowanie banku filtrów Goertzela. Porównano zaproponowane podejście z tradycyjnie stosowaną metodą STDFT. Przedstawiono wynik symulacji i pomiarów.
-
Measurement of transverse force with polarization-maintaining side-hole fibers.
PublikacjaW pracy badano możliwości wykorzystania przenoszących stan polaryzacji światłowodów typu Side-Hole do pomiaru siły działającej prostopadle do osi symetrii światłowodu. Na podstawie wyników modelowania stwierdzono, ze niektóre światłowody tego typu charakteryzują się większą czułością aniżeli standardowe światłowody przenoszące stan polaryzacji. W wyniku przeprowadzonych pomiarów potwierdzono wyniki modelowania.
-
Portable computer measurement system of machine tools in wood industry
PublikacjaW pracy przedstawiono przenośny system diagnostyczny przeznaczony do oceny pracy obrabiarek skrawających i urządzeń przemysłu drzewnego. Ocena procesu obróbczego odbywa się na podstawie pomiaru wielkości mechanicznych, takich jak: prędkość obrotowa , przemieszczenia oraz przyspieszenia. Korzystanie z programów komputerowych, w które system jest wyposażony, pozwala użytkownikowi maszyn na przeprowadzanie szczegółowych analiz, dzięki...
-
The influence of parameters of input probe on the error of high impedance measurement
PublikacjaW artykule przedstawiono sondę do pomiaru wysokich impedancji w zakresie 1kohm<|Zx|<100Gohm przeznaczoną do dołączenia do analizatorów typu gain-phase. Przeanalizowano wpływ parametrów sondy (pojemności pasożytnicze, toleranca rezystorów określających wzmocnienie wzmacniacza) na dokładność wyznaczenia modułu i argumentu zespolonego stosunku sygnałów wydzielonych w sondzie. Zamieszczono wyniki symulacji i pomiarów, pozwalające na...
-
Filtering of interference signals of grounding resistance measurement with subharmonic method
PublikacjaOmówiono metodę filtracji zakłóceń o częstotliwości sieciowej wraz z wyższymi harmonicznymi poprzez zastosowanie metody szczególnego próbkowania z podharmonicznym sygnałem pomiarowym.
-
Microsystem for measurement of impedance sensors parameters.Optoelectronic and electronic sensors V.
PublikacjaW artykule przedstawiono mikrosystem do pomiaru parametrów impedancyjnych czujników o module impedancji z przedziału 100ohm-1Gohm. Zastosowana w mikrosystemie technika cyfrowego przetwarzania sygnałów, pozwoliła na uzyskanie szerokiego zakresu częstotliwości pomiarowych, zwłaszcza bardzo niskich od 100uHz do 1MHz, przy zachowaniu prostej konstrukcji zapewniającej jego niską cenę. Mikrosystem zrealizowano w formie przyrządu...
-
Measurement of benzene concentration in urban air using passive sampling
PublikacjaAbstract The concentration of benzene in urban air in theTri-City area of Poland (Gdańsk-Sopot-Gdynia, andTczew) was assessed using diffusive passive samplers (Rad-iello). Samples were collected during a four-year monitoringcampaign (2007-2010) at selected monitoring stations man-aged by the Agency of Regional Air Quality Monitoring inthe Gdańsk Metropolitan Area (ARMAAG) Foundation.The performance of the passive samplers was investigatedin...
-
Evaluation of the fast impedance spectroscopy method in the laboratory measurement system
PublikacjaIn this paper the method for fast impedancespectroscopy of technical objects with very high impedance(|Zx| ≥ 1 GΩ) is evaluated by means of simulation and practicalexperiment. The method is based on excitation of an object, witha square pulse and measurements of voltage and currentresponses with DAQ card. The object impedance spectrum isobtained with use of continuous Fourier transform. Someimprovements of the method concerned...
-
Comparison of modelling and measurement results of spectra emitted by a programmable lamp
PublikacjaNowadays artificial light with an optimized spectrum is used in many different applications. For instance, it is widely used in museums and exhibitions to illuminate the art. Moreover, such light stimulates the growth of plants, or can be applied in industry and healthcare. To achieve the best results for each application, the adjusting of a dedicated spectrum is required, which is a complicated task. The ongoing research is focused...
-
Uncertainty estimation of loop impedance measurement determined by the vector method
PublikacjaThis article presents a detailed analysis of uncertainty estimation of loop impedance measurement determined by the vector method. The analysis includes the following estimates: resistance variance, voltage variance and time measurement variance. This paper presents a methodology for estimating the combined standard uncertainty of loop impedance by the vector method. The vector method allows to determine loop impedance based on...
-
Evaluation of Street Lighting Efficiency Using a Mobile Measurement System
PublikacjaThe issue concerns the initial stage of work on a method for performing a rapid assessment of the energy efficiency and illuminance of a street lighting installation. The proposed method is based on simultaneous measurement of illuminance from three lux meters placed on the roof of the vehicle. The data are acquired in road traffic, while the vehicle is driving. The proposed solution will allow in the future to quickly and reproducibly...
-
Nondestructive global corrosion measurement using guided wavefield data
PublikacjaMetallic structures often face degradation, and corrosion ranks among the most prevalent forms of deterioration. Accurate quantification of corrosion is crucial, especially for structures exposed to harsh environmental conditions, such as marine vessels and offshore installations. Because the traditional measurement methods based on scanning by ultrasonic gauge are time-consuming and provide only rough information on the thickness...
-
Simple Measurement Method for Resistive Sensors Based on ADCs of Microcontrollers
PublikacjaA new, complete measurement method for resistance measurement of resistive sensors for systems based on microcontrollers equipped with analog-to-digital converters (ADCs) is proposed. The interface circuit consists of only four resistors, including a resistive sensor and a reference resistor, connected directly to the microcontroller pins. It is activated only during measurements, which significantly reduces power consumption....
-
LOW COST MEASUREMENT MODULE FOR MATRIX OF AMPEROMETRIC GAS SENSOR
PublikacjaThis paper describes an amperometric sensor module for gas concentration measurement. A module can be used for many types of electrochemical gas sensors without major hardware changes. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 configurable via I2C interface is used. The concept of a measuring system composed of several modules dedicated for a gas sensors...
-
Quality of Analytical Results: Classifiying Errors and Estimating Measurement Uncertainty
PublikacjaThe most important parameter of each analytical result is its reliability. An analytical result is not a constant value; each result has two properties, error and uncertainty. The sources of both these parameters have to be known and their values determined (estimated). All analytical results are obtained by applying an appropriate measuring procedure. The need for reliable results requires application of reliable analytical procedures,...
-
MEASUREMENT O F HEALTHCARE SYSTEM EFFICIENCY IN OECD COUNTRIES
PublikacjaIncreased spending on healthcare systems in many countries tends to attract attention to their efficiency. The aim of this paper is to evaluate the efficiency of healthcare systems in the OECD countries and indicate causes of inefficiency by applying Data Envelopment Analysis (DEA) and using additive and super-efficiency models. The homogeneity of the sample is assessed and outliers are excluded. A ranking is established on the...
-
Time-of-flight fiber optic sensors for strain and temperature measurement
PublikacjaW pracy przedstawiono światłowodowy sensor czasu przelotu do pomiaru odkształceń i temperatury mogący pracować zarówno w modzie transmisyjnym, jak i odbiciowym. W pomiarach czasu przelotu wykorzystano krótkie impulsy światłowodowe wprowadzane do jednodomowego światłowodu. Pod wpływem czynników zewnętrznych (temperatura, odkształcenie, siła rozciągająca) zmieniała się droga optyczna w światłowodzie, co powodowało zmiany czasu przelotu...
-
COMPREHENSIVE MONITORING OF CHANGES IN THE GEOMETRIC STRUCTURE OF A HISTORIC BUILDING THE "SALA BHP" IN GDAŃSK
PublikacjaThe article presents selected results of the analysis of the comprehensive monitoring of the historical building of the “Sala BHP” in Gdansk. The necessity of monitoring was caused by scratches on its structural and finishing elements that occurred in the previous period. A preliminarily assumed factor that could cause the expansion of existing damages and the possible formation of new ones was the planned implementation of...
-
System setup and software for cyclic, staircase and square wave voltammetry measurements
PublikacjaHardware dedicated for electrochemical measurement sometimes does not allow performing certain voltammetry experiments. Staircase and square wave voltammetry, techniques which have many advantages comparing with standard voltammetric techniques, are rarely implemented in software controlling electrochemical measuring equipment. These methods, however, can be relatively easy realized with some addition...
-
Programmable dynamically changing RC model for evaluation of Dynamic EIS methods and instrumentation
PublikacjaThe paper concerns the RC equivalent circuit of electrochemical cell with the impedance changed during the experiment. The model was constructed using the digital potentiometers controlled by the microcontroller. This solution allows to control the model impedance by the software means. By creating adequate changes of the impedance spectrum as a time function, the different impedance measurement method can be tested to find out...
-
Power and energy measurement problems in transmission line between Poland-Lithuania
PublikacjaThe paper discusses problem of power and energy metering in double circuit overhead transmission line. Considerations are based on example of transmission line connecting Polish substation Bis Elk and Lithuanian substation Alytus.
-
Comparison of the measurement techniques employed for evaluation of ambient air odour quality
PublikacjaThe paper presents the results of investigation on ambient air odour quality in a vicinity of the industrial sewage treatment plant being a part of the crude oil processing plant. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. The field...
-
A review of design approaches for the implementation of low-frequency noise measurement systems
PublikacjaElectronic noise has its roots in the fundamental physical interactions between matter and charged particles, carrying information about the phenomena that occur at the microscopic level. Therefore, Low-Frequency Noise Measurements (LFNM) are a well-established technique for the characterization of electron devices and materials and, compared to other techniques, they offer the advantage of being non-destructive and of providing...
-
Experimental certification of an informationally complete quantum measurement in a device-independent protocol
PublikacjaMinimal informationally complete positive operator-valued measures (MIC-POVMs) are special kinds of measurement in quantum theory in which the statistics of their d2-outcomes are enough to reconstruct any d-dimensional quantum state. For this reason, MIC-POVMs are referred to as standard measurements for quantum information.Here, we report an experiment with entangled photon pairs that certifies, for what we believe is the first...
-
Selection of measurement frequency in Mott–Schottky analysis of passive layer on nickel
Publikacja -
3D MONITORING � IDENTIFICATION OF MEASUREMENT PROBLEMS AT LARGER MOVEMENTS OF THE TRACKED POINTS
Publikacja -
Shaping coherence function of sources used in low-coherent measurement techniques
Publikacja -
Analysis of Vibration and Acoustic Signals for Noncontact Measurement of Engine Rotation Speed
PublikacjaThe non-contact measurement of engine speed can be realized by analyzing engine vibration frequency. However, the vibration signal is distorted by harmonics and noise in the measurement. This paper presents a novel method for the measurement of engine rotation speed by using the cross-correlation of vibration and acoustic signals. This method can enhance the same frequency components in engine vibration and acoustic signal. After...
-
Installation of GNSS receivers on a mobile railway platform – methodology and measurement aspects
PublikacjaDetermining the course of a railway track axis using satellite methods relies on ensuring the precise assembly of GNSS receivers in dedicated measuring devices. Depending on the number of receivers, solutions that are based on placing the apparatus directly above the railway track axis (as well as in eccentric positions) are used to indirectly obtain data to form the basis of the desired results. This publication describes the...
-
Shaping of coherence function of sources used in low-coherent measurement techniques
PublikacjaW artykule przedstawiono zależność pomiędzy charakterystyką widmową źródła i ekwiwalentną długością drogi koherencji źródła. Wyniki analizy teoretycznej i symulacji komputerowych wykazały, że użycie źródła syntezowanego wpływa na zmniejszenie wartości ekwiwalentnej długości drogi koherencji. Dodatkowo wykazano, że zmniejszenie ekwiwalentnej długości drogi koherencji można otrzymać poprzez odpowiednie kształtowanie funkcji koherencji...
-
Application of acoustic emission metod for measurement of joint gap and cartilage surfaces
PublikacjaW artykule przedstawiono zastosowanie emisji akustycznej do lokalizacji wczesnych uszkodzeń stawu biodrowego lub kolanowego człowieka. Ponadto metoda ta służy do pomiaru wysokości szczeliny stawu oraz struktury geometrycznej powierzchni chrząstki stawowej. Jest to metoda nieinwazyjna. Pomiary metodą emisji akustycznej stosujemy na ogół w materiałach, w których energia sprężysta zmienia się nagle. Takie zmiany energii mogą być...
-
Shaping coherence function of sources used in low-coherent measurement techniques
PublikacjaW niskokoherencyjnych technikach pomiarowych kształt funkcji koherencji wykorzystywanego źródła ma bezpośredni wpływ na parametry metrologiczne układu pomiarowego. Z tego względu, w wielu aplikacjach niezbędne jest użycie metod pozwalających na zmianę kształtu tej funkcji. W artykule przeanalizowano możliwości kształtowania funkcji koherencji, a przedstawione analizy teoretyczne i wyniki symulacji komputerowych wskazują, że kształtowanie...
-
Structural waveguide co-doped with Yb3+/Tm3+for measurement of chlorophyll concentration
Publikacja -
Measurement and analysis of absolute quantum yield of Rhodamine B doped PMMA
Publikacja -
Portable computer diagnostics system PSD - the measurement potentiality and application examples
PublikacjaOpisano system diagnostyczny do pomiarów statycznych i dynamicznych wszelkiego typu maszyn stosowanych w przemyśle drzewnym. ocena stanu maszyny może byc dokonywana na podstawie wyników pomiaru bicia osiowego i promieniowego wrzecion, pił tarczowych, przemieszczeń poprzecznych piły tasmowej itp.. System jest wyposażony w specjalne oprogramowanie i pozwala m. in. na przeprowadzanie szczegółowych analiz tj. wykonywanie FFT lub filtrowanie...
-
Measurement of rare probes with the silicon tracking system of the CBM experiment at FAIR
Publikacja -
Chapter 6 : Non-intrusive measurement techniques in bubble dynamics investigation
PublikacjaPrzedstawiono wyniki badań dynamiki pęcherzyków parowych i gazowych przy użyciu nieinwazyjnych metod optycznych i akustycznych.
-
P-674 Automatizing ovarian follicle counting and measurement with artificial intelligence
Publikacja -
Investigation on accelerated impedance spectrum measurement method with multisine signal stimulation
PublikacjaThe paper presents an investigation on the accelerated impedance spectrum measurement method, oriented at parameter identification of technical objects modelled by a linear equivalent circuit, e.g. anticorrosion coatings.The method is based on multisine signal stimulation of an object and response analysis by triangle window filterbanks.It has several advantages, as compared with conventional point-by-point spectrum measurement....
-
Installation of GNSS receivers on a mobile railway platform – methodology and measurement aspects
Publikacja -
3D Monitoring - Identification of measurement problems at larger movements of the tracked points
PublikacjaAuthors identified the problems associated with the determination of the controlled points coordinates by use of automated Total Station placed behind transparent barrier. Important thing in the mentioned analysis was a large change of controlled points position and not stable Total Station’s stand (because of stand’s thermal drift). This two elements, combined with measurement made through glass plate determine the need for impact...
-
Low-power device simulator for micro-energy measurement methods testing
PublikacjaThe paper presents low-power device simulator designed for testing of micro-energy measurement methods. Such kind methods can be used for evaluation of power systems based on Energy Harvesting. The device allows to set the current consumption characteristic over the time, thus making possible playing the role of different types of low-power devices e.g. simulating sensor network node.
-
Evaluation of expanded uncertainty of instantaneous power measurement in a bearing diagnostic system.
PublikacjaThe paper presents the issues concerning the estimation of the expanded uncertainty in the system for the diagnosis of rolling bearings, consisting of transducers: voltage and current voltage, which is used for diagnostic bearing motors method based on the measurement and analysis of the instantaneous power signal consumed by the induction motor. It presents the methodology for assessing the measurement uncertainty and presents...
-
Measurement of Impulse Response of Shallow Water Communication Channel by Correlation Method
PublikacjaPerformances of underwater acoustic communication (UAC) systems are strongly related to specific propagation conditions of the underwater channel; conditions that can additionally change in time due to the movement of the acoustic system transmitter and receiver or to reflection by underwater objects of the transmitted signal. The time-varying impulse response is a comprehensive description of dynamically changing transmission...
-
Measurement of the Development of a Learning IT Organization Supported by a Model of Knowledge Acquisition and Processing
PublikacjaThe paper presents a model of knowledge acquisition and processing for the development of learning organizations. The theory of a learning organization provides neither metrics nor tools to measure its development The authors' studies in this field are based on their experience gathered after projects realized in real IT organizations. The authors have described the construction of the model and the methods of its verification...
-
Electrodes array for contactless ECG measurement of a bathing person - a sensitivity analysis
PublikacjaAn applicability of a remote (contactless) electrocardiogram (ECG) measurements in a bathtub is presented in the paper. Possibility of ECG measurements in shallowly filled tube with a water was examined. A bathing person was, both, sitting and lying during experiments performed. The problem became non-trivial when the bathing person was moving in reference to a fixed set of electrodes and located at the longer walls of the bathtub....
-
Nanocrystalline diamond sheets as protective coatings for fiber-optic measurement head
PublikacjaFiber-optic sensors find numerous applications in science and industry, but their full potential is limited because of the risk of damaging the measurement head, in particular, due to the vulnerability of unprotected tips of the fiber to mechanical damage and aggressive chemical agents. In this paper, we report the first use of a new nanocrystalline diamond structure in a fiber-optic measurement head as a protective coating of...