Wyniki wyszukiwania dla: MEASUREMENT METHODS
-
Selected aspects of two-phase flow studies using different visualization techniques in minichannels
PublikacjaThe subject of the study is to present the possibility of the use of visualization techniques in the researches on two-phase flows, carried out by the authors for many years. These works included as follows: heat transfer during the flow boiling, boiling crises and condensation in flow. The issue of the heat transfer intensification during the flow boiling through the channels of small diameters was analyzed. All this work focused...
-
An Instantaneous Engine Speed Estimation Method Using Multiple Matching Synchrosqueezing Transform
PublikacjaInstantaneous rotational speed measurement of the engine is crucial in routine inspection and maintenance of an automobile engine. Since the contact measurement of rotational speed is not always available, the vibration measurement has been used for noncontact rotational speed estimation methods. Unfortunately, the accuracy of the noncontact estimation methods by analyzing engine vibration frequency is not satisfactory due to the...
-
Noninvasive method for rotor fault diagnosis in inverter fed induction motor drive
PublikacjaThis article presents a proposal, simulation and experimental results of a noninvasive rotor fault diagnosis method for the inverter fed induction motor drive. Comparing to reported methods the proposed one does not require any load, rotor brake, slip, mechanical or electrical system physical modification e.g. machine disassembly and can be applied regardless the rotor speed measurement or estimation method.
-
Thermal, electrical, and magnetic properties of Fe2O3–PbO–SiO2 glass prepared by traditional melt-quenching and twin roller fast-cooling methods
PublikacjaIn this study, Fe–Pb–Si oxide glasses containing between 12.5 and 17.5 mol% Fe2O3 were prepared using two different methods comprising traditional melt-quenching and twin roller fast-cooling techniques. The topography and structure of the materials obtained were characterized by X-ray powder diffraction and scanning electron microscopy. All of the materials were found to be amorphous. The topography of most of the glasses comprised...
-
MCSA with Normalized Triple Covariance as a bearings diagnostic indicator in an induction motor
PublikacjaStatistics of bearing failures in induction motors indicate, that they constitute more than 40% of IM damage, therefore bearing diagnosis is very important. Vibration methods for bearing diagnostics have one major disadvantage - they require the availability of the machine for sensors installation. This is the reason for seeking new methods based on motor supply current analysis. Diagnosis of induction motors, conducted remotely...
-
Pomiar sił w wantach mostu podwieszonego
PublikacjaW artykule przedstawiono metodę oraz wyniki badań sił w wantach Mostu III Tysiąclecia im. Jana Pawła II w Gdańsku. Do identyfikacji sił wykorzystano trzy metody: wibracyjną; z wykorzystaniem siłownika jednosplotowego (lift-off) oraz pomiaru strzałki ugięcia. Przedstawione wyniki badań dowodzą, że wszystkie metody mogą być z powodzeniem wykorzystywane do identyfikacji rzeczywistej siły w wancie. Każda z metod ma jednak ograniczenia...
-
Modelling of spirometry - the application for diagnostic purposes
PublikacjaThe process of the tissue oxygen supply is the fundamental process of the human life. The lung functioning consists of three processes: the ventilation, the perfusion and the diffusion. The paper deals with one of these processes which is the ventilation process. The quality of the pulmonary ventilation has a strong influence on the patient's health condition. Numerous limitations are imposed on conditions of the lung quality measurement,...
-
Bezczujnikowe sterowanie trakcyjnym silnikiem IPMSM małej mocy
PublikacjaThis paper describes an algorithm for estimation of IPMSM angular rotor position. The algorithm uses derivatives of motor phase currents resulting from PWM modulation to obtain the rotor position. Control of the IPMSM electromagnetic torque requires a precise estimation of the rotor angular position throughout the wide speed range. This involves using a set of estimation methods switched with the dependence on the actual rotor...
-
Reducing of energy consumption in public transport - results of experimental exploitation of super capacitor energy bank in Gdynia trolleybus system
PublikacjaPaper presents the result of test exploitation supercapacitor energy bank in Gdynia trolleybus system. In the first part of the article the basics of the regenerative breaking are presented and the construction and control strategy of the supercapacitor bank are described. The area of research and method of measurement are explained. In the second part of paper the results of tests and measurements are described. Emphasis was placed...
-
Electrochemical capacitor temperature fluctuations during charging/discharging processes
PublikacjaThepaperpresentsaproposalofusingadditionalstatisticalparameterssuchas:standarddeviation,variance, maximum and minimum increases of the observed value that were determined during measurements of temperature fields created on the surface of the tested electrochemical capacitor. The measurements were carriedoutusingthermographicmethodsinordertosupportassessmentoftheconditionofelectrochemical capacitorunderclassicdurabilitytestsbasedonmethodsofdeterminationofcapacityandequivalentseries...
-
Waveguide model of the hearing aid earmold system
PublikacjaBackground The earmold system of the Behind-The-Ear hearing aid is an acoustic system that modifies the spectrum of the propagated sound waves. Improper selection of the earmold system may result in deterioration of sound quality and speech intelligibility. Computer modeling methods may be useful in the process of hearing aid fitting, allowing physician to examine various earmold system configurations and choose the optimum one...
-
Waveguide model of the hearing aid earmold system
PublikacjaBackground The earmold system of the Behind-The-Ear hearing aid is an acoustic system that modifies the spectrum of the propagated sound waves. Improper selection of the earmold system may result in deterioration of sound quality and speech intelligibility. Computer modeling methods may be useful in the process of hearing aid fitting, allowing physician to examine various earmold system configurations and choose the optimum one...
-
The differential impact of a density of Polish pine wood on cutting forces with its origin region taken into consideration
PublikacjaIn the article the dependence of cutting forces in a function the density of wood with regard to the wood origin are presented. Samples used in experiment were with Scotch pine (Pinus sylvestris L.) originating from four provenances in Poland (Figure 1). Wood density was measured by two methods: stereometric method (global density) and radiometric method (local density). Stereometric method consists in measurements the volume...
-
Strouhal Number Measurement for Novel Biomimetic Folding Fins Using an Image Processing Method
Publikacja -
Application of the Least Squares Method to the approximation of equally spaced samples in frequency measurement approach
Publikacja -
The Influence of Noise Level on the Value of Uncertainty in a Measurement System Containing an Analog-to-Digital Converter
Publikacja -
Analysis of occurrence of guided disorders in selected railway equipment — impact of load on measurement results
Publikacja -
Feature-Based Characterisation of Turned Surface Topography with Suppression of High-Frequency Measurement Errors
Publikacja -
Measurement of temperature-dependent viscosity and thermal conductivity of alumina and titania thermal oil nanofluids
PublikacjaThe results of simultaneous measurements of dynamic viscosity, thermal conductivity, electrical conductivity and pH of two nanofluids, i.e. thermal oil/Al2O3 and thermal oil/TiO2 are presented. Thermal oil was selected as a base liquid because of possible application in ORC systems as an intermediate heating agent. Nanoparticles were tested at the concentration of 0.1%, 1% and 5% by weight within temperature range from 20°C to...
-
Factory Acceptance Test – Strain Gauge Measurement, Report no: WOiO /II/123/2014
PublikacjaTested object was 40 meters long jib and its foundation, placed in Gdansk Shiprepair Yard, manufactured by KMK. The contruction was dedicated to the passenger cruise vessel "Quantum of the Seas" The Strain Gauge measurement in different location and load situation was done in order to validate calculation finite element models used during strength analysis for project. The expertise contains: methodology of the measurements, description...
-
Factory Acceptance Test – Strain Gauge Measurement - Report no: WOiO /II/88/2014
PublikacjaTested object was 40 meters long jib and its foundation, placed in Gdansk Shiprepair Yard, manufactured by KMK. The contruction was dedicated to the passenger cruise vessel "North Star" The Strain Gauge measurement in different location and load situation was done in order to validate calculation finite element models used during strength analysis for project. The expertise contains: methodology of the measurements, description...
-
Electrochemical sensor for measurement of volatile organic compounds employing square wave perturbation voltage
PublikacjaThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde in air. Sensitivity and limit of quantification of the sensor were determined for different internal electrolyte using the square wave voltammetry (SWV) as a detection technique. The working and counter electrodes were made of platinum. Ionic liquids 1-hexyl, 3-methylimidazolium chloride,1-hexyl, 3-methylimidazolium bis (trifluoromethanesulfonyl)...
-
The critical rotational speed of circular saw: simple measurement method and its practical implementations.
PublikacjaProducenci pił tarczowych są zobligowani do podawania ich dopuszczalnych prędkości obrotowych. Jednakże, umieszczane przez nich prędkości na piłach są często bliskie prędkościom krytycznym lub je przewyższają. Przecinanie takimi narzędziami może być więc niebezpieczne dla obsługującego. Praca przedstawia prostą metodologię wyznaczania prędkości obrotowych krytycznych pił tarczowych. Badania były prowadzone z wykorzystaniem technik...
-
Method using bilinear transformation for measurement of impedance parameters of a multielement two-terminal network
PublikacjaArtykuł przedstawia metodę identyfikacji parametrów impedancyjnych obiektów modelowanych dwójnikami. Metoda wykorzystuje właściwości przekształcenia biliniowego pozwalającego na przedstawienie impedancji obiektu jako funkcji każdego z parametrów obwodu zastępczego z osobna. Odwrotne przekształcenie biliniowe pozwala na wyznaczenie wartości każdego parametru na podstawie pomiaru impedancji na jednej częstotliwości dobranej dla...
-
Measurement of selected characteristics of low-coherence optical signal sources for optical coherence tomography
Publikacja -
Optimal Placement of Phasor Measurement Unit in Power System using Meta-Heuristic Algorithms
PublikacjaThe phasor measurement units (PMUs) play an important and vital role in power system monitoring and controlling, since they provide the power system phasors stamped with a common real time reference through a global positioning system (GPS). Indeed, from economical point of view it is not possible to set PMUs in all system buses due to the high cost and the requirement of more complex communication...
-
Interlaboratory comparison of methodologies for the measurement of urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine
Publikacja -
3D Sound Intensity Measurement Around Organ Pipes Using Acoustic Vector Sensors
PublikacjaThe aim of the presented paper was to obtain and visualize sound intensity distribution of radiated acoustic energy around the organ pipes. The experimental setup consisted of the multichannel acoustic vector sensor and the specialized Cartesian robot. Measurements were performed in free field with spatial resolution of 0.1 [m]. Two organ pipes, i.e. wooden and metal were measured during the ex-periment. The organ pipes were activated...
-
Impedance Measurement and Selection of Electrochemical Equivalent Circuit of a Working PEM Fuel Cell Cathode
PublikacjaThe dynamic impedance analysis of direct methanolfuel cell (DMFC) cathode supplied with pure oxygen is pre-sented. Presented results were obtained during dynamic chang-es of the current density in working fuel cell. Investigation ofthe occurring processes at cathode was carried with dynamicelectrochemical impedance spectroscopy (DEIS). A discussionwas conducted based on the determined correlation parameterχ2. It was shown that...
-
Dynamic mass measurement in checkweighers using a discrete time-variant low-pass filter
PublikacjaConveyor belt type checkweighers are complex mechanical systems consisting of a weighing sensor (strain gauge load cell, electrodynamically compensated load cell), packages (of different shapes, made of different materials) and a transport system (motors, gears, rollers). Disturbances generated by the vibrating parts of such a system are reflected in the signal power spectra in a form of strong spectral peaks, located usually in...
-
Using On-line Measurement by Electronic Nose and Computer Simulations for Real-time Control at WWTP
PublikacjaContinuous investigation of wastewater quality can be carried out by a device called an e-nose. One important feature of the proposed real-time control system for WWTP is that using on-line measurements by e-nose together (Figure 1) with technological sets picked on this basis by means of computer models, it is possible to change treatment process parameters, depending on the current quality of wastewater. It can be used for the...
-
Measurement of dynamic pulsations in bulk solid during silo discharging using ECT method
PublikacjaW pracy przedstawiono wyniki pomiarów pulsacji materiału sypkiego pomieroznych z zastosowaniem metody pomiarowej ECT. Analizę dynamicznych zmian koncetracji przperowadzono dla podstawowych(surowych) danych pomiarowych oraz danych zrekonstruowanych
-
The concept of estimation of elevator shaft control measurement results in the local 3D coordinate system.
PublikacjaGeodetic control measurements play an important part because they provide information about the current state of repair of the construction, which has a direct impact on the safety assessment of its exploitation. Authors in this paper have focused on control measurements of the elevator shaft. The article discusses the problem of determining the deviation of elevator shaft walls from the vertical plane in the local 3D coordinate...
-
Discussion of Derivability of Local Residual Stress Level from Magnetic Stray Field Measurement
PublikacjaThe NDT procedure dubbed ‘metal magnetic memory’ method and the related ISO 24497 standard has found wide industrial acceptance in some countries, mainly in Russia and China. The method has been claimed by some researchers (Roskosz and Bieniek in NDT&E Int 45:55–62, 2012; Wilson et al. in Sens Actuators A 135:381–387, 2007) as having potential for quantitative determination of local residual stress state in engineering structures,...
-
MEASUREMENT OF TEMPERATURE-DEPENDENT VISCOSITY AND THERMAL CONDUCTIVITY OF ALUMINA AND TITANIA THERMAL OIL NANOFLUIDS
PublikacjaIn this study results of simultaneous measurements of dynamic viscosity, thermal conductivity, electrical conductivity and pH of two nanofluids, i.e. thermal oil/Al2O3 and thermal oil/TiO2 are presented. Thermal oil is selected as a base liquid because of possible application in ORC systems as an intermediate heating agent. Nanoparticles were tested at the concentration of 0.1%, 1% and 5% by weight within temperature range from...
-
Performance of DS-CDMA Radionavigation Receiver with Subsample Time Measurement Resolution in Various Environments
PublikacjaThis paper presents results of investigation of position estimation performance in TDOA radionavigation system with receiver containing code tracking loop with subsample time measurement resolution. Position estimation accuracy was evaluated using real signals from CDMA base stations, recorded during measurement campaigns in various environments: on sea, flat terrain and hilly terrain.
-
Frequency measurement research with weight averaging of pulse output signal of voltage-to-frequency converter
PublikacjaThe paper presents the essence and investigation of the efficiency of weight averaging of a pulse output signal of voltage-to-frequency converter. The effect of counting and the influence of interference on the result of weight averaging of frequency modulated pulses are analyzed. It is shown that from the point of view of counting error reduction, the best are polynomial weight functions. In the case of high interferences whose...
-
Application of the short time Fourier transformation to the continuous frequency method of measurement of electrode impedance
PublikacjaPrzedstawiona została nowa metoda pomiaru impedancji elektrodowej. Wykorzystuje ona jako pobudzenie niestacjonarny sygnał napięciowy, którego częstotliwość jest liniową funkcją czasu. Zastosowanie transformacji STFT do analizy napięciowego sygnału pobudzenia i odpowiedzi prądowej umożliwia wyznaczenie widma impedancyjnego. Dokładność otrzymywanych wartości impedancji uwarunkowana jest wielkością okna i zastosowanej funkcji analizującej.
-
Measurement of relative tool displacement to the workpiece for the assesment of influences of machining errors on surface profiles
PublikacjaZaprezentowano układ pomiarowy promieniowego i osiowego przemieszczenia narzędzia względem przedmiotu dla identyfikacji oddziaływań układu obróbkowego na formowanie struktury geometrycznej powierzchni toczonej. Zawiera on dwa analogowe tory pomiarowe przemieszczeń względnych z bezstykowymi przetwornikami i przetwarzaniem a/c oraz cyfrowy tor pomiaru obrotu przedmiotu, jego znacznik i interfejs z komputerem. Pomierzono sygnały przemieszczeń...
-
Measurement of pulse signal period from incremental encorder by counters of Multifunctuin DAQ devices.
PublikacjaW artykule omówiono parametry liczników znajdujących się na wielofunkcyjnych kartach akwizycji sygnałów pomiarowych. Przedstawiono przygotowane w środowisku programowania Lab VIEW aplikacje wykorzystujące te liczniki. Służą one do pomiaru i rejestracji długości zadanej liczby okresów mierzonego sygnału oraz liczby okresów uzależnionej od ich długości (metoda zliczania zależnego z wydłużonym czasem pomiaru). Aplikacje te zostały...
-
Ellipse-fitting algorithm implementation in the impedance measurement system based on DAQ card with FPGA
PublikacjaThe paper presents an implementation of the ellipse-fitting algorithm in the impedance measurement system based on DAQ card equipped with FPGA chip. The method implementation was tested by simulation means as well as experimentally in the designed and presented measurement system. Finally, the limit values of sampling parameters which assures satisfying accuracy were given.
-
Measurement of selected characteristics of low-coherence optical signal sources for optical coherence tomography
PublikacjaOCT to nowa metoda badania wewnętrznych struktur materiałów. Wśród wielu technik detekcji sygnału optycznego wykorzystywanych w OCT najpopularniejszą i najbardziej obiecującą jest OLCR (Opticla-Low Coherence Reflectomerty - reflektometria niskokoherentna). OLCR wykorzystuje szerokopasmowe źródła, których parametry, jak np.: charakterystyka widmowa, charakterystyka szumowa, determinują właściwości metrologiczne systemu OCT. W artykule...
-
Determination of the uncertainty of mass flow measurement using the orifice for different values of the Reynolds number
PublikacjaStandard orifice flowmeters are widely used in the chemical and energy industry. Therefore, it is essential to know how accurate the measurements made with these instruments are. The paper presents an estimation of measurement uncertainty of a liquid mass flow using the orifice plate. The authors will present the influence of ranges of the Reynolds number on the estimated uncertainty, obtained on the basis of simulation and laboratory...
-
Measurement system for nonlinear surface spectroscopy by atomic force microscopy for corrosion processes monitoring
PublikacjaIn addition to traditional imaging the surface, atomic force microscopy (AFM) enables wide variety of additional measurements. One of them is higher harmonic imaging. In tapping mode the nonlinear contact between tip and specimen results in higher frequency vibrations. More information available from the higher harmonics analysis proves to be helpful for more detailed imaging. Such visualization is especially useful for heterogeneous...
-
The Influence of Camera and Optical System Parameters on the Uncertainty of Object Location Measurement in Vision Systems
PublikacjaThe article presents the influence of the camera and its optical system on the uncertainty of object position measurement in vision systems. The aim of the article is to present the methodology for estimating the combined standard uncertainty of measuring the object position with a vision camera treated as a measuring device. The identification of factors affecting the location measurement uncertainty and the determination of their...
-
Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset
PublikacjaThe dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.
-
Measurement of Seafloor Acoustic Backscatter Angular Dependence at 150 kHz Using a Multibeam Echosounder
PublikacjaAcoustic seafloor measurements with multibeam echosounders (MBESs) are currently often used for submarine habitat mapping, but the MBESs are usually not acoustically calibrated for backscattering strength (BBS) and cannot be used to infer absolute seafloor angular dependence. We present a study outlining the calibration and showing absolute backscattering strength values measured at a frequency of 150 kHz at around 10–20 m water...
-
Testing of Software for the Planning of a Linear Object GNSS Measurement Campaign under Simulated Conditions
PublikacjaThe precision of a linear object measurement using satellite techniques is determined by the number and the relative position of the visible satellites by the receiver. The status of the visible constellation is described by DOP. The obtained geometric coefficient values are dependent on many variables. When determining these values, field obstacles at the receiver location and satellite positions changing with time must be taken...
-
STUDY OF ARRAY OF MEMS INERTIAL MEASUREMENT UNITS UNDER QUASI-STATIONARY AND DYNAMIC CONDITIONS
PublikacjaA measurement system includes all components in a chain of hardware and software that leads from a measured variable to processed data. In that context, the type and quality of the sensors or measuring devices are critical to any measurement system. MEMS/IMU sensors lag behind leading technologies in this respect, but the MEMS/IMU performance rapidly changes while is relatively inexpensive. For this reason, the paper proposes...
-
A Measurement System for Quasi-Spectral Determination of Absorption and Scattering Parameters of Veterinary Tissue Phantoms
PublikacjaThis paper describes the construction of a system for the quasi-spectral determination of absorption and scattering parameters of animal tissue phantoms. Several tissue phantoms, including one reference and two modified for examination, were prepared from polydimethylsiloxane (PDMS). The phantoms were measured using a system based on an integrating sphere and the light sources of wavelengths commonly used for the treatment of various...