Experimental Investigation of the Performance of an Innovative Implantable Left Ventricular Assist Device—Proof of Concept
PublikacjaThis paper presents the results of experimental performance of an innovative left ventricular assist device working on a specially designed test stand. The introduced invention is mainly applied for supporting the heart in patients with end-stage heart failure accompanied by mitral valve regurgitation and pulmonary hypertension. Moreover, the developed device has the form of a flexible balloon forming an intracardiac inert gas-filled...
-
Innovative Implantable Left Ventricular Assist Device—Performance under Various Resistances and Operating Frequency Conditions
PublikacjaThis paper presents the operation of an innovative left ventricular assist device under various resistances and operating frequencies. The operating principle of the device is based on pulsatile blood flow, which is forced by a suction–discharge device pumping helium into a set of intra-cardiac balloons. In this way, the ejection fraction of the left ventricle is increased, and the mitral valve is additionally occluded. What is...
-
COMPOSITE MATERIAL SELECTION FOR A PATIENT TRANSFER ASSIST DEVICE
PublikacjaLaminates - layered composites containing at least two elements (matrix and reinforcement) widely used in industry have also found their usage in medicine. Their main feature is the ability to modify the material in order to obtain the required properties. Depending on the needs, we can modify reinforcement, type of resin or the method of bonding substrates. Commonly used fibers are: carbon fiber, glass and aramid fibers; resins...
-
Effect of Vascular Lumen Reduction on the Performance and Energy Consumption of an Innovative Implantable LVAD
PublikacjaThis paper presents the results of a study on the effect of vascular lumen reduction on the performance of an innovative implantable LVAD (left ventricular assist device). It details the pressures in the individual cardiac chambers as a function of device frequency. In addition, mass flow rates and energy consumption of the device are examined, varying with lumen reduction and operating frequency. While the lumen reduction of the...
-
Methods of navigation in the mobile application supporting movement of the blind
PublikacjaThis paper presents conclusions from the last development phase of the “Voice Maps” project. Authors specify newly found available options for navigation in affordable system for the blind with all their related aspects. System uses dedicated geographical data, built-in smartphone GPS receivers and DGPS external device in order to assist blind users in their everyday travelling. Authors also discuss new methods to improve positioning...
-
LTE and NB-IoT Performance Estimation Based on Indicators Measured by the Radio Module
PublikacjaMonitoring the operating parameters of power grids is extremely important for their proper functioning as well as for ensuring the security of the entire infrastructure. As the idea of the Internet of Things becomes more ubiquitous, there are tools for monitoring the state of the complex electrical grid and means to control it. There are also developed new measuring devices and transmission technologies allowing for the transfer...
-
Optoelectronic device for hematocrit measurements
PublikacjaAn optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed...
-
Degradation of implantable materials – in vivo and in vitro research
PublikacjaThe article concerns the biological and electrochemical degradation of metallic implants in vivo and in vitro studies. The in vivo research dealt with degradation of plates used to join bones, as well as endoprostheses. The most common damages were: metalosis, breaking in the microstructure changes, breaking in area of holes, as well as plastic deformation throughout the length of an implant. The material used for the research...
-
Device for spoofing in global positioning system
PublikacjaThis article describes the device which may be used to generate false GPS signals and emit them into radio communication channel. Such attack is called GPS spoofing. Each GPS receiver which remains in the range of a spoofing device (called spoofer) indicates time and position coordinates which are predetermined by the spoofer’s operator. Spoofing may be used e.g. in order to disable the terrorist group from obtaining correct navigation...
-
A Device for Measuring Auditory Brainstem Responses to Audio
PublikacjaStandard ABR devices use clicks and tone bursts to assess subjects’ hearing in an objective way. A new device was developed that extends the functionality of a standard ABR audiometer by collecting and analyzing auditory brainstem responses (ABR). The developed accessory allows for the use of complex sounds (e.g., speech or music excerpts) as stimuli. Therefore, it is possible to find out how efficiently different types of sounds...
-
STRUCTURE AND ALGORITHMS OF A DIAGNOSTIC DEVICE IN A WHEELED TRACTOR
PublikacjaDiagnostic device monitors the tractor’s technical condition and identifies the location of damaged components during operation. The diagnostic device detects and identifies the following types of defects: functional defects (uf) which affect performance, exhaust defects (ue) which increase toxic emissions and fuel consumption, defects that jeopardize driving safety (us), defects that affect engine performance (ud). The key component...
-
The novel sterilization device: the prototype testing
PublikacjaCurrently, there are numerous methods that can be used to neutralize pathogens (i.e., devices, tools, or protective clothing), but the sterilizing agent must be selected so that it does not damage or change the properties of the material to which it is applied. Dry sterilization with hydrogen peroxide gas (VHP) in combination with UV-C radiation is well described and effective method of sterilization. This paper presents the design,...
-
Combined environmental testing device for picosatellites
PublikacjaAs access to space conditions becomes more available, both technically and economically, scientists’ interest in launching finer and more sophisticated experiments grows. To be qualified for launch, such experiments need to be carefully tested prior to the event. The tests should represent actual launch conditions as closely and in a detailed manner. Typical tests for payload include: vibration tests, thermal and vacuum tests,...
-
A New Rehabilitation Device for Balance Impaired Individuals
PublikacjaIn the paper authors present a device designed to improve the rehabilitation process of people with balance impairment. The discussed device (JStep) utilizes a commercially available static standing frame (stander) modified in order to fit force sensing units under the feet and in the pillows around the hips of a patient. While executing rehabilitation tasks, the patient may compensate his balance deficiency by leaning on the pillows...
-
Relationship between semi- and fully-device-independent protocols
PublikacjaWe study the relation between semi and fully device independent protocols. As a tool, we use the correspondence between Bell inequalities and dimension witnesses. We present a method for converting the former into the latter and vice versa. This relation provides us with interesting results for both scenarios. First, we find new random number generation protocols with higher bit rates for both the semi and fully device independent...
-
Auto adaptation of mobile device characteristics to various acoustic conditions
PublikacjaThe proposed methodology of auto adaptation of the mobile device characteristics to various acoustic conditions is presented in the paper. The first goal of this study was to determine the parameters of the acoustic path of the mobile device, for both transmitting (speaker) and receiver (microphone). Results of the measurement of characteristics of mobile devices were presented. Information about characteristics of individual parts...
-
Validation of atmospheric aerosols parallel sampling in a multifold device
PublikacjaIn this work, particulate matter was collected using an active sampling system consisting of a PM10 (<10 μm) inlet coupled to a multifold device containing six channels, connected to a vacuum pump. Each channel was equipped with a filter holder fitted with adequately chosen filters. The system was fixed on a metallic structure, which was placed on the roof of the laboratory building, at the Faculty of Sciences, in Lisbon. Sampling...
-
Particle Image Velocimetry Measurements of Airflow in Electrohydrodynamic Device for Dust Particle Collection
PublikacjaIn this paper the electrohydrodynamic (EHD)device for gas pumping and cleaning is presented. To induce an airflow in this EHD device corona discharge was used. The discharge was generated between the one-sided spike electrodes and the plate electrodes. An asymmetric electric field and generated discharge result in unidirectional gas flow through the EHD device. The current-voltage characteristics were measured and the corona discharge...
-
Particle Image Velocimetry Measurements of Airflow in Electrohydrodynamic Device for Dust Particle Collection
PublikacjaIn this paper the pumping effect of air in the electrohydrodynamic (EHD) device for dust particle collection is presented. To induce an airflow in this EHD device corona discharge was used. The discharge was generated between the one-sided spike electrodes and the plate electrodes. The asymmetric electric field and generated discharge resulted in a unidirectional airflow through the EHD device. The current-voltage characteristics...
-
Design of a continuous intra-oral distraction device for mandibular bone
PublikacjaIn this paper we present example of a specific device used for distraction osteogenesis. Distraction osteogenesis (also called callus distraction, collotasis or osteodistraction) is a surgical process for reconstructing bone deformities or lengthening bones.