wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: MICROCONTROLLER INTERFACING IMPEDANCE SENSORS ADCS TIME-DOMAIN MEASUREMENT
-
Time-domain measurement methods for R, L and C sensors based on aversatile direct sensor-to-microcontroller interface circuit
PublikacjatIn the paper new time-domain measurement methods for determining values of resistive (R), inductive(L) and capacitive (C) sensors based on a versatile direct sensor-to-microcontroller interface for microcon-trollers with internal analog-to-digital converters (ADCs) and analog comparators (ACs) are presented.The interface circuit consists of a reference resistor Rrworking as a voltage divider, a given R, L or C sensorand a microcontroller...
-
Kazimierz Darowicki prof. dr hab. inż.
OsobyStudia wyższe ukończyłem w czerwcu 1981 roku po zdaniu egzaminu dyplomowego i obronie pracy magisterskiej. Opiekunem pracy magisterskiej był dr hab. inż. Tadeusz Szauer. W roku 1991, 27 listopada uzyskałem stopień naukowy broniąc pracę doktorską zatytułowaną „Symulacyjna i korelacyjna analiza widm immitancyjnych inhibitowanej reakcji elektrodowej”. Promotorem pracy był prof. dr hab. inż. Józef Kubicki (Wydział Chemiczny...
-
Simple Measurement Method for Resistive Sensors Based on ADCs of Microcontrollers
PublikacjaA new, complete measurement method for resistance measurement of resistive sensors for systems based on microcontrollers equipped with analog-to-digital converters (ADCs) is proposed. The interface circuit consists of only four resistors, including a resistive sensor and a reference resistor, connected directly to the microcontroller pins. It is activated only during measurements, which significantly reduces power consumption....
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublikacjaIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
A measurement method for lossy capacitive relative humidity sensors based on a direct sensor-to-microcontroller interface circuit
PublikacjaA new time-domain measurement method for determining the capacitance and resistance values of lossy relative humidity capacitive sensors is presented. The method is based on a direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators and timers. The interface circuit consists only of four reference resistors (two reference resistors if a microcontroller includes a voltage reference source),...
-
IMPEDANCE MEASUREMENT MODULE FOR GAS SENSORS WITH TEMPERATURE CONDITIONING FEATURE
PublikacjaThe paper presents an impedance measurement module which is aimed for gas sensor. Sensor’s heater temperature conditioning and modulation feature is available in order to allow implementation of different techniques improving selectivity and sensitivity of gas sensors. The measurement module uses three-parameter sine-fitting technique for impedance measurement. To monitor sensor temperature, the resistance of the sensor’s heater...
-
Scalable Measurement System for Multiple Impedance Gas Sensors
PublikacjaAuthor proposes scalable architecture of the measurement system for gas sensor with impedance dependance of the gas concentration. The main part of the system is a single-board impedance analyser. The number of analysers working in parallel can be configured according to specific application. The system is controlled by a single computer which organises the measurement cycle and store the acquired measurement data. The system is...
-
A microcontroller system for measurement of three independent components in impedance sensors using a single square pulse
PublikacjaOpracowano nową metodę pomiaru w dziedzinie czasu i wyznaczania trzech składowych elementów modelu czujnika impedancyjnego oraz zaimplementowano ją w inteligentnym czujniku impedancji sterowanym 8-bitowym mikrokontrolerem. Metoda bazuje na pobudzeniu dzielnika napięciowego składającego się z rezystora pełniącego funkcję konwertera prąd na napięcie i z czujnika impedancji pojedynczym impulsem prostokątnym o czasie trwania T bezpośrednio...
-
Position and velocity measurement using incremental encoder and microcontroller.
PublikacjaThere is presented measurement of position and velocity using Atmel's microcontroller ATTiny2313 with 20 MHz clock and encoder with 1024 pulses per revolution. This configuration allows measuring maximum speed 48800 rpm with 1x accuracy, 20200 rpm with 2x accuracy and 9400 rpm with 4x accuracy (quadrature). Position is measured with resolution of 0.352', 0.176' and 0.088' for 1x, 2x, 4x accuracy respectively. Algorithms of position...
-
Microsystem for measurement of impedance sensors parameters.Optoelectronic and electronic sensors V.
PublikacjaW artykule przedstawiono mikrosystem do pomiaru parametrów impedancyjnych czujników o module impedancji z przedziału 100ohm-1Gohm. Zastosowana w mikrosystemie technika cyfrowego przetwarzania sygnałów, pozwoliła na uzyskanie szerokiego zakresu częstotliwości pomiarowych, zwłaszcza bardzo niskich od 100uHz do 1MHz, przy zachowaniu prostej konstrukcji zapewniającej jego niską cenę. Mikrosystem zrealizowano w formie przyrządu...
-
Using A Particular Sampling Method for Impedance Measurement
PublikacjaThe paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was...
-
Photoplethysmographic Time-Domain Heart Rate Measurement Algorithm for Resource-Constrained Wearable Devices and its Implementation
PublikacjaThis paper presents an algorithm for the measurement of the human heart rate, using photoplethysmography (PPG), i.e., the detection of the light at the skin surface. The signal from the PPG sensor is processed in time-domain; the peaks in the preprocessed and conditioned PPG waveform are detected by using a peak detection algorithm to find the heart rate in real time. Apart from the PPG sensor, the accelerometer is also used to...
-
Measurement method for capacitive sensors for microcontrollers based on a phase shifter
PublikacjaA complete measurement method dedicated to capacitive sensors has been developed. It includes the development of hardware (an analogue interface circuit for microcontrollers with built-in times/counters and analogue comparators) and software (a measurement procedure and a systematic error calibration (correction) algorithm which is based on a calibration dictionary). The interface circuit consists of a low-pass filter and a phase...
-
Measurement: Sensors
Czasopisma -
Uncertainty estimation of loop impedance measurement determined by the vector method
PublikacjaThis article presents a detailed analysis of uncertainty estimation of loop impedance measurement determined by the vector method. The analysis includes the following estimates: resistance variance, voltage variance and time measurement variance. This paper presents a methodology for estimating the combined standard uncertainty of loop impedance by the vector method. The vector method allows to determine loop impedance based on...
-
Implementation of Extended Kalman Filter with Optimized Execution Time for Sensorless Control of a PMSM Using ARM Cortex-M3 Microcontroller
PublikacjaThis paper addresses the implementation and optimization of an Extended Kalman Filter (EKF) for the Permanent Magnet Synchronous Motor (PMSM) sensorless control using an ARM Cortex-M3 microcontroller. A various optimization levels based on arithmetic calculation reduction was implemented in ARM Cortex-M3 microcontroller. The execution time of EKF estimator was reduced from 260.4 μs to 37.7 μs without loss of accuracy. To further...
-
Time-of-flight fiber optic sensors for strain and temperature measurement
PublikacjaW pracy przedstawiono światłowodowy sensor czasu przelotu do pomiaru odkształceń i temperatury mogący pracować zarówno w modzie transmisyjnym, jak i odbiciowym. W pomiarach czasu przelotu wykorzystano krótkie impulsy światłowodowe wprowadzane do jednodomowego światłowodu. Pod wpływem czynników zewnętrznych (temperatura, odkształcenie, siła rozciągająca) zmieniała się droga optyczna w światłowodzie, co powodowało zmiany czasu przelotu...
-
Self-Testing of Analog Parts Terminated by ADCs Based on Multiple Sampling of Time Responses
PublikacjaA new approach for self-testing of analog parts terminated by analog-to-digital converters in mixed-signal electronic microsystems controlled by microcontrollers is presented. It is based upon a new fault diagnosis method using a transformation of the set of voltage samples of the time response of a tested analog part to a square impulse into localization curves placed in a multidimensional measurement space. The method can be used...
-
Grzegorz Lentka dr hab. inż.
OsobyGrzegorz Lentka uzyskał tytuł magistra inżyniera w roku 1996 na Wydziale Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej w zakresie systemów pomiarowych. Stopień doktora nauk technicznych uzyskał w roku 2003, a doktora habilitowanego w 2014. Obecnie zatrudniony jest w Katedrze Metrologii i Optoelektroniki na stanowisku profesora PG. W ramach prowadzonej dydaktyki zajmuje się zagadnieniami związanymi z interfejsami...
-
Swapping Space for Time: An Alternative to Time-Domain Interferometry
PublikacjaYoung's double-slit experiment [1] requires two waves produced simultaneously at two different points in space. In quantum mechanics the waves correspond to a single quantum object, even as complex as a big molecule. An interference is present as long as one cannot tell for sure which slit is chosen by the object. The more we know about the path, the worse the interference. In the paper we show that quantum mechanics allows for...
-
Investigation on accelerated impedance spectrum measurement method with multisine signal stimulation
PublikacjaThe paper presents an investigation on the accelerated impedance spectrum measurement method, oriented at parameter identification of technical objects modelled by a linear equivalent circuit, e.g. anticorrosion coatings.The method is based on multisine signal stimulation of an object and response analysis by triangle window filterbanks.It has several advantages, as compared with conventional point-by-point spectrum measurement....
-
Application of electrochemical sensors and sensor matrixes for measurement of odorous chemical compounds
PublikacjaIn this paper describes the principle of operation of the electrochemical sensors and the sensor matrixes comprised of electrochemical sensors intended for measurement of odorous compounds. Critical comparison of these sensors’ advantages and disadvantages has been made. The fields of economy contributing to release of odours and the potential sources of their emission have been identified. Commercially available electrochemical...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublikacjaThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Time domain diagnosis of anticorrosion coatings via shape designed measurement signals.
PublikacjaW pracy przedstawiono operującą w dziedzinie czasu metodę diagnostyki pokryć przeciwkorozyjnych, na poziomie identyfikacji parametrów obwodu zastępczego. Metoda jest oparta na pobudzeniu obiektu sygnałem niekonwencjonalnym o projektowanym kształcie i pomiarze odpowiedzi obiektu (tzw. obserwabla) po upływie zadanego czasu T. Parametry obwodu zastępczego są obliczane bezpośrednio z obserwabli na podstawie równań wynikających z topologii...
-
Evaluation of the fast impedance spectroscopy method in the laboratory measurement system
PublikacjaIn this paper the method for fast impedancespectroscopy of technical objects with very high impedance(|Zx| ≥ 1 GΩ) is evaluated by means of simulation and practicalexperiment. The method is based on excitation of an object, witha square pulse and measurements of voltage and currentresponses with DAQ card. The object impedance spectrum isobtained with use of continuous Fourier transform. Someimprovements of the method concerned...
-
Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset
PublikacjaThe dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.
-
Study of Metrological Properties of Voltammetric Electrodes in the Time Domain
PublikacjaMetrological properties of voltammetric electrodes, in the situation where on their surface an electrochemical reaction of oxidizing/reduction takes place, were analyzed in this chapter. The properties of electrodes on which a reaction controlled by ion transport process takes place were taken into consideration. Also, it was analyzed how the electrode’s shape and the voltage polarizing the electrode influence this electrode’s...
-
Chirp-rate estimation of FM signals in the time-frequency domain
PublikacjaNovel dynamic representations of a complex signal in the time-frequency domain including: a channelized instantaneous complex frequency (CICF), a complex local group delay (CLGD) and a channelized instantaneous chirp-rate (CICR) are introduced. The proposed approach is based on the use of the gradient of the short-time Fourier transform complex phase. An interpretation of the newly-introduced distributions especially of the CICR...
-
Application of the short time Fourier transformation to the continuous frequency method of measurement of electrode impedance
PublikacjaPrzedstawiona została nowa metoda pomiaru impedancji elektrodowej. Wykorzystuje ona jako pobudzenie niestacjonarny sygnał napięciowy, którego częstotliwość jest liniową funkcją czasu. Zastosowanie transformacji STFT do analizy napięciowego sygnału pobudzenia i odpowiedzi prądowej umożliwia wyznaczenie widma impedancyjnego. Dokładność otrzymywanych wartości impedancji uwarunkowana jest wielkością okna i zastosowanej funkcji analizującej.
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublikacjaIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Flicker Noise in Resistive Gas Sensors—Measurement Setups and Applications for Enhanced Gas Sensing
PublikacjaWe discuss the implementation challenges of gas sensing systems based on low-frequency noise measurements on chemoresistive sensors. Resistance fluctuations in various gas sensing materials, in a frequency range typically up to a few kHz, can enhance gas sensing by considering its intensity and the slope of power spectral density. The issues of low-frequency noise measurements in resistive gas sensors, specifically in two-dimensional...
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublikacjaMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Ellipse-fitting algorithm implementation in the impedance measurement system based on DAQ card with FPGA
PublikacjaThe paper presents an implementation of the ellipse-fitting algorithm in the impedance measurement system based on DAQ card equipped with FPGA chip. The method implementation was tested by simulation means as well as experimentally in the designed and presented measurement system. Finally, the limit values of sampling parameters which assures satisfying accuracy were given.
-
Fixed Pattern Noise Reduction and Linearity Improvement in Time-Mode CMOS Image Sensors
PublikacjaIn the paper, a digital clock stopping technique for gain and offset correction in time-mode analog-to-digital converters (ADCs) has been proposed. The technique is dedicated to imagers with massively parallel image acquisition working in the time mode where compensation of dark signal non-uniformity (DSNU) as well as photo-response non-uniformity (PRNU) is critical. Fixed pattern noise (FPN) reduction has been experimentally validated...
-
TIME- AND FREQUENCY-DOMAIN QUASI-2D SMALL-SIGNAL MOSFET MODELS
PublikacjaA novel approach to small-signal MOSFET modeling is presented in this book. As a result, time- and frequency-domain physics-based quasi-2D NQS four-terminal small-signal MOSFET models are proposed. The time-domain model provides the background to a novel DIBL-included quasi‑2D NQS four-terminal frequency-domain small-signal MOSFET model. Parameters and electrical quantities of the frequency-domain model are described by explicit...
-
Time domain model of the resonance-based electromagnetic pulses emission system
PublikacjaIn the literature, the emission properties of the electromagnetic field pulse systems based on high voltage antennas (HVR) have been widely described. In order to increase the emission efficiency by extending duration and increasing amplitude of the impulse it is possible to use a resonance system tuned to the parameters of the signal shaped in the pulse forming circuit. The synthesis of a time-domain simulation model of a complex...
-
Time-Domain Description of Point-Source Acoustic Wavefields as a Useful Approach in Ultrasonic Techniques
PublikacjaIn traditional acoustics, field problems are usually treated in the frequency domain, broadband fields being reduced to superposition of harmonic spectrum components. However, this approach is inherently acausal and it is known that in case of arbitrary signals, the distribution-based, time-domain description can be more effective. The present paper is an attempt to expand the time-domain linear systems formalism onto space problems...
-
Time-domain description of point-source acoustic wavefields as a useful approach in ultrasonic techniques
PublikacjaIn traditional acoustics, field problems are usually treated in the frequency domain, broadband fields being reduced to superposition of harmonic spectrum components. However, this approach is inherently acausal and it is known that in case of arbitrary signals, the distribution-based, time-domain description can be more effective. The present paper is an attempt to expand the time-domain linear systems formalism onto space problems...
-
Finite-difference time-domain analyses of active cloaking for electrically-large objects
PublikacjaInvisibility cloaking devices constitute a unique and potentially disruptive technology, but only if they can work over broad bandwidths for electrically-large objects. So far, the only known scheme that allows for broadband scattering cancellation from an electrically-large object is based on an active implementation where electric and magnetic sources are deployed over a surface surrounding the object, but whose ‘switching on’...
-
Time evolution of Electrochemical Impedance spectra of cathodically protected steel in artificial seawater
PublikacjaUsability of Electrochemical Impedance Spectroscopy data for better cathodic protection control was investigated. Carbon steel – S235JR2 grade specimen were exposed in artificial seawater environment. Samples were polarized and their potentials corresponded to four different cathodic protection degrees. Time evolution of Electrochemical Impedance spectra was investigated. Goodness of fit function (X2) was analysed in terms of proper...
-
Effect of Time Varying Measurement Conditions on Antenna Pattern in Near Field Measurement and Its Correction Procedure
PublikacjaAuthors present the procedure of taking into account the changes of electrical parameters of setup due to the time drift of temperature during the procedure of near field measurement. It is proposed to make additional measurements in determined positions of probe are next used the results to introduce corrections terms in measured data. Such approach was verified practically in experimental near field measurement system.
-
A novel method of local chirp-rate estimation of LFM chirp signals in the time-frequency domain
PublikacjaIn the paper, novel dynamic representations of a complex signal in the time-frequency domain are introduced. The proposed approach is based on using the gradient of the short-time Fourier transform complex phase. A channelized instantaneous complex frequency (CICF) and a complex local group delay (CLGD) are included in the presented signal representations. An application of the newly-introduced distributions is demonstrated by...
-
Determination of time delay between ventricles contraction using impedance measurements
PublikacjaThe paper presents a novel approach to assessment of ventricular dyssynchrony basing on multichannel electrical impedance measurements. Using a proper placement of electrodes, the sensitivity approach allows estimating time difference between chambers contraction from over determined nonlinear system of equations. The theoretical considerations which include Finite Element Method simulations were verified using measurements on...
-
Hybrid‐mode single‐slope ADC with improved linearity and reduced conversion time for CMOS image sensors
PublikacjaIn the paper, a single‐slope analog‐to‐digital converter (ADC) for integrated CMOS image sensor applications with an improved technique of conversion has been proposed. The proposed hybrid‐mode ADC automatically uses one of the following conversion techniques: time based (i.e. PWM) or voltage based (i.e. single‐slope). During the ADC operation, the clock frequency and reference voltage are modified in order to reduce the conversion...
-
Analytical Expression for the Time-Domain Discrete Green's Function of a Plane Wave Propagating in the 2-D FDTD Grid
PublikacjaIn this letter, a new closed-form expression for the time-domain discrete Green's function (DGF) of a plane wave propagating in the 2-D finite-difference time-domain (FDTD) grid is derived. For the sake of its verification, the time-domain implementation of the analytic field propagator (AFP) technique was developed for the plane wave injection in 2-D total-field/scattered-field (TFSF) FDTD simulations. Such an implementation of...
-
Analytical Expression for the Time-Domain Green's Function of a Discrete Plane Wave Propagating in the 3-D FDTD Grid
PublikacjaIn this paper, a closed-form expression for the time-domain dyadic Green’s function of a discrete plane wave (DPW) propagating in a 3-D finite-difference time-domain (FDTD) grid is derived. In order to verify our findings, the time-domain implementation of the DPW-injection technique is developed with the use of the derived expression for 3-D total-field/scattered-field (TFSF) FDTD simulations. This implementation requires computations...
-
Time window based features extraction from temperature modulated gas sensors for prediction of ammonia concentration
PublikacjaElectronic gas recognition systems, in literature commonly referred as electronic noses, enable the recognition of a type and a concentration of various volatile compounds. Typical electronic gas-analyzing device consists of four main elements, namely, gas delivery subsystem, an array of gas sensors, data acquisition and power supply circuits and data analysis software. The commercially available metal-oxide TGS sensors are widely...
-
Nonlinear Modeling in Time Domain Numerical Analysis of Stringed Instrument Dynamics
PublikacjaMusical instruments are very various in terms of sound quality with their timbre shaped by materials and geometry. Materials' impact is commonly treated as dominant one by musicians, while it is unclear whether it is true or not. The research proposed in the study focuses on determining influence of both these factors on sound quality based on their impact on harmonic composition. Numerical approach has been chosen to allowed independent...
-
Applications of the discrete green's function in the finite-difference time-domain method
PublikacjaIn this paper, applications of the discrete Green's function (DGF) in the three-dimensional (3-D) finite-difference time-domain (FDTD) method are presented. The FDTD method on disjoint domains was developed employing DGF to couple the subdomains as well as to compute the electromagnetic field outside these subdomains. Hence, source and scatterer are simulated in separate subdomains and updating of vacuum cells, being of little...
-
Sinusoidal Alternating-Current Voltammetry and Metrological Properties of a Flat Voltammetric Electrode in the Time Domain
PublikacjaIn this paper there were analyzed metrological properties of a flat electrode used to mark ions with the method of sinusoidal alternating-current voltammetry in the situation where on its surface an electrochemical reversible reaction of oxidizing / reduction takes place. The result of the analysis conducted is that such a voltammetric electrode functions like a converter type I. Metrological properties of such an electrode in...