Filtry
wszystkich: 85
Wyniki wyszukiwania dla: WWTP, TRICKLING FILTERS, FILAMENTOUS BACTERIA, COD, BOD5
-
Effect of organic nitrogen concentration on the efficiency of trickling filters
PublikacjaThe study was conducted in Poland at six selected wastewater treatment plants (WWTP) based on the trickling filters Bioclere® technology. The aim of the study was to find the relationship between the influent organic nitrogen concentration and the purification efficiency expressed as effluent COD concentration. In the tests performed, the COD to BOD5 relationship was close to 2 and the ratio of BOD5 to TN was lower than 4. The...
-
The wastewater flow through trickling filters.
PublikacjaFiltry zraszane projektowane są głównie w oparciu o wytyczne techniczne. W pracy zaproponowano metodę o charakterze strukturalnym. Pokazano sposób określania miarodajnego czasu przebywania cieczy w układzie i powiązania go z kinetyczną charakterystyką procesu oczyszczania ścieków.
-
The application of moving bed biofilm reactor to denitrification process after trickling filters
PublikacjaThe paper presents research of a prototype moving bed biofilm reactor (MBBR). The device was used for the post-denitrification process and was installed at the end of a technological system consisting of a septic tank and two trickling filters. The concentrations of suspended biomass and biomass attached on the EvU Perl moving bed surface were determined. The impact of the external organic carbon concentration on the denitrification...
-
Use of aluminium for controlling the filamentous bacteria growth in the activated sludge systems
PublikacjaPrzedstawiono kilkuletnie doświadczenia technologiczne, dotyczące wykorzystania glinu w celu ograniczania negatywnych skutków masowego rozwoju mikroorganizmów nitkowatych (dominująca bakteria - Microthrix parvicella) w wielofazowym systemie osadu czynnego (MUCT) gdańskiej oczyszczalni ścieków komunalnych. Stosowanie dobowych dawek w zakresie od 2,0 do 2,5 g Al/kg suchej masy osadu czynnego eliminowało pianę biologiczną z bioreaktorów...
-
Sewage gardens - constructed wetlands for single family households
PublikacjaDuring the last 30 years the increase of interest in low-cost decentralized and small wastewater treatment plants (WWTP) is observed in Europe. For this purpose sand filters, stabilization ponds, mini reactors with activated sludge, trickling filters and treatment wetlands are used. Among the listed facilities treatment wetlands (TWs) offer effective and reliable treatment efficiency, being at the same time low-cost and simple...
-
Influence of composition of raw wastewater on removal of nitrogen compounds in multistage treatment wetlands
PublikacjaInfluence of composition of raw wastewater on the efficiency of organic matter and nitrogen removal in multistage treatment wetlands has been examined. Commonly used indicators, like COD/BOD5 and BOD5/TN ratio, determining wastewater susceptibility to biodegradation in conventional treatment technologies were assessed. It was confirmed that multistage treatment wetland may be used for treatment of wastewater with high loads of...
-
Biotrickling filtration of air polluted with hexane and cyclohexane: effects of trickling liquid modification with DES solutions
Dane BadawczeDataset presents selected parameters monitored during processes of biotrickling filtration of air polluted with hexane and cyclohexane.
-
Influence of landfill leachate on municipal wastewater treatment - model plant(WWTP-MP)
PublikacjaAbstract In the current study, wastewater treatment model plant (WWTP-MP) was used to investigate the possibilities of landfill leachate co-treatment together with municipal wastewater. The WWT-MP, designed as an A2O multiphase system, was fed with the raw municipal wastewater (from the WWTP Gdańsk "Wschód'', Qav.=82x103 m3/d) with increasing, from 1 to 5 % (vol.), quantity of landfill leachate (collected from Gdańsk landfill ''Szadółki")....
-
WAYS TO IMPROVE THE EFFICIENCY OF WASTEWATER TREATMENT OF A CARDBOARD AND PAPER MILL
PublikacjaThe results of research on physical and chemical methods for the preliminary treatment of wastewater of a cardboard and paper factory in Khmelnytskyi region of Ukraine are presented. At the cardboard and paper factory, wastewater is treated at a sewage treatment plant, which includes sand traps, primary radial sedimentation tanks, aeration tanks with activated sludge regenerators, secondary radial sedimentation tanks, and bioponds....
-
Sewage sludge pretreatment by low thermal disintegration for better efficacy of sludge digestion process
PublikacjaThe wastewater water treatment plant (WWTP) sector and it is developing technologies strive to be implement circular economy. The methane production from the sludge digestion process constitute promising source of the renewable energy for WWTP and approaching circular economy assumptions. For this reason, the objective of the study was to examine the modification of sludge characteristics due to the low temperature pretreatment....
-
Rain Gardens SW quality dataset
Dane BadawczeThis dataset contains the results of parameters of storm water runoff and storm water quality in rain garden units. Samples were collected from 4 different rain gardens in Gdansk, Poland.
-
STORMWATER AS AN ALTERNATIVE WATER SOURCE: QUALITY CHANGES WITH RAINFALL DURATION AND IMPLICATIONS FOR TREATMENT APPROACHES
PublikacjaThe pressure on the world’s water resources is rapidly increasing due to population growth and climatic changes. Valorisation of stormwater as a water resource for non-potable reuse can reduce high-quality water demands and save it for potable uses. In this context, not only roof runoff but also drained stormwater outflow, representing considerably higher pollution levels, should be considered as a potential resource. We analysed...
-
Study of Different Advanced Oxidation Processes for Wastewater Treatment from Petroleum Bitumen Production at Basic pH
PublikacjaEffluents from production of petroleum bitumens were submitted to treatment by three different AOPs at basic pH (i.e., O3, H2O2 and the combination of O3 and H2O2, a so-called peroxone). The paper presents studies on the identification and monitoring of the volatile organic compounds (VOCs) degradation present in the effluents and formation of byproducts, COD, BOD5, sulfide ions, biotoxicity, and biodegradability changes during...
-
The efficiency and reliability of pollutant removal in a hybrid constructed wetland with giant miscanthus and Jerusalem artichoke in Poland
PublikacjaIn this paper, we analysed the pollutant removal efficiency and reliability of a vertical and horizontal flow hybrid constructed wetland (CW) planted with giant miscanthus and Jerusalem artichoke. The wastewater treatment plant, located in south-eastern Poland, treated domestic sewage at an average flow rate of 1.2m3·d−1. The tests were carried out during. 5-years of operation of the sewage treatment plant (2011–2016). During this...
-
Wpływ ścieków przemysłowych na energochłonność i efektywność procesów technologicznych w komunalnej oczyszczalni ścieków
PublikacjaW artykule skupiono się na przedstawieniu wpływu jakości i ilości ścieków przemysłowych wprowadzanych do sieci kanalizacyjnej PEWIK GDYNIA Sp. z o. o. na stabilność procesów technologicznych. Określono również wpływ ścieków przemysłowych na energochłonność i efektywność oraz na wzrost kosztów oczyszczania ścieków komunalnych w Grupowej Oczyszczalni Ścieków „Dębogórze” w latach 2012-2015.
-
Assessment of the technological reliability of a hybrid constructed wetland for wastewater treatment in a mountain eco-tourist farm in Poland
PublikacjaThe aim of the present study was to assess the technological reliability of a domestic hybrid wastewater treatment installation consisting of a classic three-chambered (volume 6 m3) septic tank, a vertical flow trickling bed filled with granules of a calcinated clay material (KERAMZYT), a special wetland bed constructed on a slope, and a permeable pond used as a receiver. The test treatment plant was located at a mountain eco-tourist...
-
Application of Extreme Doses of Aluminium for Growth Control of Filmentous Bacteria Microthrix Parvicella in an Activated Sludge System - Laboratory Investigations
PublikacjaLaboratory investigations of aluminium (PAX-16) application for control of population of filamentous bacteria Microthrix Parvicella in a three-phase bioreactor in lab-scale were performed. Dosing of small aluminium doses (approximately 0.5 mgAl/gMLSS·d) in the period preceding seasonal growth of M.Parvicella failed to prevent mass growth of this microorganism leading to activated sludge bulking phenomenon (SVI-250 ml/gMLSS)...
-
Synergistic effect of TiO2 photocatalytic advanced oxidation processes in the treatment of refinery effluents
PublikacjaDifferent types of photolytic and photocatalytic advanced oxidation processes (AOPs) were used for treatment of refinery effluents from bitumen production. The treatment efficiency was evaluated by analyzing chemical oxygen demand (COD), biological oxygen demand (BOD5), volatile organic compounds (VOCs) and sulfide ions concentration. The studies revealed a synergistic effect of application of external oxidants (O3, H2O2, O3/H2O2)...
-
Removal of cyclohexane vapors from air in biotrickling filters: Effects of gas mixture composition and circular economy approach
PublikacjaThis work presents results of investigations on biotrickling filtration of air polluted with cyclohexane co-treated in binary, ternary and quaternary volatile organic compounds (VOCs) mixtures, including vapors of hexane, toluene and ethanol. The removal of cyclohexane from a gas mixture depends on the physicochemical properties of the co-treated VOCs and the lower the hydrophobicity of the VOC, the higher the removal efficiency...
-
Effects of liquid phase modification on the values of surface tension of trickling liquid
Dane BadawczeDataset presents the values of surface tension of trickling liquid sampled from three running biotrickling filters.
-
Effects of liquid phase modification on the performance of biotrickling filters
Dane BadawczeDataset presents the effects of liquid phase modification on the biotrickling filtration (BTF) performance of air polluted with toluene, ethylbenzene, xylene and styrene.
-
Application of subsurface vertical flow constructed wetlands to reject water treatment in dairy wastewater treatment plant
PublikacjaThe paper presents the effects of applying subsurface vertical flow constructed wetlands (SS VF) for the treatment of reject water generated in the process of aerobic sewage sludge stabilization in the biggest dairy wastewater treatment plant (WWTP) in Poland. Two SS VF beds were built: bed (A) with 0.65 m depth and bed (B) with 1.0 m depth, planted with reeds. Beds were fed with reject water with hydraulic load of 0.1 m d-1 in...
-
Multistage treatment wetland for treatment of reject waters from digested sludge dewatering
PublikacjaThe paper presents the influence of sewage composition on treatment in pilot-scale facility for reject waters (RW) from sewage sludge centrifugation. The facility consisted of mechanical (two tanks with 10 d retention each) and biological parts composed of three subsurface flow reed beds working in batch. Two years of monitoring of the facility proved high efficiency removal of predominant pollutants: COD 75–80%, BOD 82.2–95.5%...
-
Comparative Study of Balancing SRT by Using Modified ASM2d in Control and Operation Strategy at Full-Scale WWTP
PublikacjaDetailed knowledge on the composition of the influent going into the wastewater treatment system is essential for the development of a reliable computer model. In the context of WWTPs (wastewater treatment plants), the wastewater characteristics are not only important for activated sludge system modelling, but also have an impact on the appropriate control of single unit operations. The aim of this study was to evaluate the concepts...
-
BIOVAC® WASTEWATER TREATMENT PLANTS IN THE MOUNTAIN NATIONAL PARKS.
PublikacjaThis paper presents characteristics of the Biovac® wastewater treatment plants operating in the mountain areas of the Polish national parks (NP): Tatrzanski NP and Babiogórski NP as well as in the West Spitsbergen NP. On the basis of the laboratory tests performed on raw sewage and the final effluent the efficiency of the wastewater treatment plants was evaluated. It was found that high COD values and rather high COD / BOD5 ratios...
-
Insights into the microbial community of treated wastewater, its year-round variability and impact on the receiver, using cultivation, microscopy and amplicon-based methods
PublikacjaApart from chemical constituents, wastewater treatment plant (WWTP) effluents also release microorganisms that can be important to the receiving water bodies either from a sanitary point of view, or taking to the account the biogeochemical potential of the recipients. However, little is known about the treated wastewater microbial community, its composition, seasonal changes, functions and fate in the waters of the receiver. Thus,...
-
Pathways of nitrogen compounds depletion in hybrid constructed wetlands
PublikacjaHybrid Constructed Wetlands are composed of two or more filters with mixed flow direction of sewage. Apparently in the HCWS the benefits of both types of bed are merged, resulting in better effluent quality (organic and nitrogen componds removal). Such heterogeneous environment creates possibilities for different ways of nitrogen "disappearing". The objective of the present study was to compare the removal of nitrogen with accompanying...
-
Pathways of Nitrogen Removal in Hybrid Treatment Wetlands
PublikacjaHybrid Treatment Wetlands (HTWs) are composed of two or more filters with different modes of flow, allowing the benefits of both types of bed to be combined, resulting in better effluent quality (nitrogen and organic compounds removal). Such a heterogeneous environment creates possibilities for different mechanisms of nitrogen removal. The objective of the present study was to investigate the removal of nitrogen versus a range...
-
Reliability and efficiency of pollution removal during long-term operation of a one-stage constructed wetland system with horizontal flow
PublikacjaThe paper presents the results of a study of the reliability and efficiency of pollutant removal during long term operation of a one-stage constructed wetland system with horizontal flow. The flow rate of the wastewater treatment plant was 1.2 m3·d-1 during the research period. Physical and chemical analyses of raw wastewater and treated effluent were carried out in the years 1997–2010 (14 years). During this study period, 56 series...
-
The role of the combined nitrogen-sulfur-carbon cycles for efficient performance of anammox-based systems
PublikacjaThe combined anammox/mixotrophic denitrification process was conducted in two granular sequencing batch reactors (SBRs) during a 200-day operation. Both reactors were fed with synthetic medium, but SBR2 was enriched with additional sulfate (SO4 2 ) which influenced sulfate reduction ammonium oxidation (SRAO) and heterotrophic reduction of SO4 2 by sulfate reducing bacteria. It was hypothesized that the addition of SO4 2 could...
-
Investigation of Microbes in the Stratosphere – Stardust Project
PublikacjaThe stratospheric microbiota has been investigated many times using the methods of classical microbiology. In this research a few modern methods, including NGS sequencing and multiple displacement amplification of DNA, were in use. The analysis of metagenome helped to determine the content of various species of bacteria in the sample collected in the stratosphere by a hydrogen-filled balloon holding...
-
The influence of moderate pressure and subzero temperature on the shelf life of minced cod, salmon, pork and beef meat
PublikacjaThe effect of moderate pressure at subzero temperature on natural microflora of minced cod, salmony, pork and beef meat was studied. Pressure of 193 MPa at –20 °C caused reduction of total bacterial count in pork and beef meat by 1.1 and 0.6 log cycles, respectively, and by about 1.5 log cycles in fish meat. Under these conditions the psychrophilic and psychrotophic bacteria were below the detection limit (<10CFU/g of sample) in...
-
Determination of COD Fractionation as a Key Factor for Appropriate Modelling and Monitoring of Activated Sludge Processes
PublikacjaAn operation of wastewater treatment plant is usually controlled by global parameters such as flow, solids retention time, sludge age, concentration of ammonia and dissolved oxygen, etc. It is considered that, together with the chemical and biological oxygen demand (COD and BOD), those parameters indirectly exhibit the effectiveness of activated sludge processes. Especially the BOD indicate the amount of organic pollution that...
-
The evaluation of COD fractionation and modeling as a key factor for appropriate optimization and monitoring of modern cost-effective activated sludge systems
PublikacjaA study was conducted to characterize the raw wastewater entering a modern cost effective municipal WWTP in Poland using two approaches; 1) a combination of modeling and carbonaceous oxygen demand (COD) fractionation using respirometric test coupled with model estimation (RTME) and 2) flocculation/filtration COD fractionation method combined with BOD measurements (FF-BOD). It was observed that the particulate fractions of COD obtained...
-
Adaptive stochastic and hybrid nonlinear optimization algorithms for improving the effectiveness of the biological processes at WWTP
PublikacjaWastewater treatment plays an important factor in the modern world. Insufficient treatment may result in environmental pollution which can further lead to disasters and diseases. However, processes that take place inside wastewater treatment plants (WWTP) are highly complex in nature, therefore it is difficult to design an efficient, optimal control system. The problem regarding biochemical reactions inside Sequential Batch Reactor...
-
The role of SSVF and SSHF beds in concentrated wastewater treatment, design recommendation
PublikacjaThe return flows of reject water from sewage sludge dewatering alter the activated sludge process ina conventional WWTP and increase TN concentration in the final effluent from WWTP. The objectiveof the investigation carried out was to consider the application of multistage treatment wetland(MTW) for the treatment of reject water from sewage sludge dewatering in a centrifuge (RWC). Thispaper aims to present the design and performance...
-
The effects of different aeration modes on ammonia removal from sludge digester liquors in the nitritation–anammox proces
PublikacjaThe aim of this study was to determine the impact of continuous and intermittent aeration on the rate of ammonia removal in the combined nitritation–anammox process. This process was run in two parallel sequencing batch reactors (SBRs), with a working volume V = 10 L, treating sludge digester liquors from the Gdansk (Poland) wastewater treatment plant (WWTP). The ammonia oxidizing bacteria were cultivated from activated sludge...
-
Packing Incubation and Addition of Rot Fungi Extracts Improve BTEX Elimination from Air in Biotrickling Filters
PublikacjaThe removal of benzene, toluene, ethylbenzene, and xylene (BTEX) from air was investigated in two similar biotrickling filters (BTFs) packed with polyurethane (PU) foam, differing in terms of inoculation procedure (BTF A was packed with pre-incubated PU discs, and BTF B was inoculated via the continuous recirculation of a liquid inoculum). The effects of white rot fungi enzyme extract addition and system responses to variable VOC...
-
Modeling external carbon addition in combined N-P activated sludge systems with an extension of the IWA Activated Sludge Models
PublikacjaThe aim of this study was to expand the IWA Activated Sludge Model No. 2d (ASM2d) to account for a newly defined readily biodegradable substrate that can be consumed by polyphosphate accumulating organisms (PAOs) under anoxic and aerobic conditions, but not under anaerobic conditions. The model change was to add a new substrate component and process terms for its use by PAOs and other heterotrophic bacteria under anoxic and aerobic...
-
Modeling external carbon addition in combined N-P activated sludge systems with an extension of the IWA Activated Sludge Models
PublikacjaThe aim of this study was to expand the IWA Activated Sludge Model No. 2d (ASM2d) to account for a newly defined readily biodegradable substrate that can be consumed by polyphosphate accumulating organisms (PAOs) under anoxic and aerobic conditions, but not under anaerobic conditions. The model change was to add a new substrate component and process terms for its use by PAOs and other heterotrophic bacteria under anoxic and aerobic...
-
The Simulation of Activated Sludge System for Optimization of Predictive Aeration at Large WWTP
PublikacjaEffective use of biodegradable substrates as an internal carbon sources (ICS) for denitrification and EBPR and predicting performance of aeration systems during nitrification in activated sludge bioreactors, may be useful in realization the sustainable development by potentially saving energy consumption at WWTPs. A large number of WWTPs use activated sludge systems with an integrated removal of carbon, nitrogen and phosphorus...
-
Evaluation of Partial Nitritation/Anammox (PN/A) Process Performance and Microorganisms Community Composition under Different C/N Ratio
PublikacjaA one-stage partial nitritation/anammox (PN/A) process with intermittent aeration is possible under sidestream conditions, but implementation in a mainstream is a challenge due to increased Carbon/Nitrogen (C/N) ratios in domestic wastewater. This study investigated the effect of C/N ratios on process efficiency and the effect of narrowing non-aeration time on process improvement at high chemical oxygen demand (COD) load. An increase...
-
Changes of microbiological quality of water in distribution system. Zmiany mikrobiologicznej jakości wody w sieci dystrybucyjnej.
PublikacjaW artykule przedstawiono mikrobiologiczną jakość wody podziemnej uzdatnianej w dwóch stacjach oczyszczania wody (WTP I i WTP II), w sieci dystrybucyjnej. Obie stacje uzdatniania stosują dezynfekcję za pomocą dwutlenku chloru. Badania wykazały wzrost ogólnej liczby bakterii w miarę zwiększania się odległości od stacji uzdatniania.In the paper microbiological quality of water in distribution system produced in two ground water treatment...
-
Badania stabilności biologicznej wody w wybranych systemach wodociągowych
PublikacjaW pracy przedstawiono wyniki badań mikrobiologicznych wody powierzchniowej i wód podziemnych z rejonu Trójmiasta, które zasilają systemy dystrybucji charakteryzujące się nikim stosunkiem powierzchni kontaktu do objętości przesyłanej wody (≈0,65) w aspekcie ich stabilności biologicznej. Dokonano oceny skuteczności zastosowanych procesów uzdatniania w usuwaniu ogólnej liczby bakterii (OLB), a w badaniach laboratoryjnych określono...
-
The use of various species of fungi in biofiltration of air contaminated with odorous volatile organic compounds
PublikacjaAir pollution with odorous compounds is a significant social and environmental problem. This paper presents biological deodorization methods. The attention is focused on the application of biotrickling filters for air deodorization. Principles of their operation are discussed, indicating the key role of the selection of microorganisms responsible for the degradation of odorous compounds. A literature overview of the used fungal...
-
The effect of high pressure on formation of volatile amines in minced meat of cod (Gadus morhua)
PublikacjaThe effects of high pressure at subzero temperature (193 MPa, at −20 °C) on inactivation of natural microflora of cod meat and degradation of trimethylamine oxide (TMAO) to trimethylamine (TMA) during refrigerated storage and to dimethylamine (DMA) and formaldehyde (FA) during frozen storage were investigated. The content of TMA, DMA and FA in cod meat did not change immediately after pressure treatment. During 40 days of frozen...
-
Efficiency of pollutant removal by five multistage constructed wetlands in a temperate climate
PublikacjaIn recent years, an increase in interest in hybrid constructed wetland systems (HCWs) has beenobserved. These systems are composed of two or more filters with different modes of sewage flow.Based on over eight years of monitoring, carried out at five local HCWs located in the PomeraniaRegion of Northern Poland, the effective removal of organic matter (from 74.9 to 95.5% COD) in theloading range 1.5-17.0 g COD·m-2·d-1 was confirmed....
-
Kinetics of pollutants removal in vertical and horizontal flow constructed wetlands in temperate climate
PublikacjaThis paper reports a comparative study on kinetics of organic matter expressed as BOD5 and nitrogen removal in constructed wetlands operated in Poland. Analyzed data were collected at eight wetland systems, composed of subsurface flow beds: horizontal flow (HF) and vertical flow (VF), in different number and sequences. The analysis involved particularly mass removal rates (MRR) and first-order removal rate coefficients of BOD5...
-
BEXUS 30 Stardust – Preliminary Results of Investigation of Microbes in the Stratosphere
PublikacjaThe stratospheric microbiome has been investigated several times using the methods of classical microbiology. In this experiment, we have combined them with some novel approaches.. Diversification of methods has helped better describe the collected microorganisms. The results of the experiment may help better understand the mechanisms of survivability of microorganisms in stratospheric conditions.
-
Treatment of landfill leachate by constructed wetlands: three case studies
PublikacjaThe performance of three CW systems treating landfill leachate, two located in northern Poland (Szadółki near Gdańsk and Gatka near Miastko) and one in southern Sweden (Örebro), is discussed. The CWs differ in size, hydraulic regime, type of hydrophytic plants and type of leachate pre-treatment before discharging to the CW. The CW in Szadółki consists of two parallel beds with sub-surface, horizontal flow of leachate (HSSF) planted...